• Title/Summary/Keyword: vertical earth pressure

Search Result 186, Processing Time 0.032 seconds

An Experimental Study on the Earth Pressure Effect of Vertical Reinforcements (연직보강재의 토압경감 효과)

  • 문경선;이상덕
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.457-464
    • /
    • 1999
  • The active earth pressure on the retaining wall is reduced by 3-Dimensional effects of the ground. Therefore, the test was focused on reducing the earth pressure on the retaining wall by inserting the vertical reinforcement in the backfill ground to develope the 3-Dimensional effects. Model tests in sand were peformed to measure the 3-Dimensional effects of the vertical reinforcement on the active earth pressure and its distribution and results were compared with the theories. The size of the vertical reinforcement, the geometry of the backfill space, and the wall friction of vertical reinforcement were varied. It was observed that the active earth pressure and its distribution on the underground structure were affected by the size of the vertical reforcements and wall friction.

  • PDF

Investigation of Earth Pressure on Vertical Shaft by Field Monitoring (현장계측을 통한 원형 수직구 작용하중 분석)

  • Shin, Youngwan;Moon, Kyoungsun;Kang, Hyutaek;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.4
    • /
    • pp.63-76
    • /
    • 2008
  • This research was carried in order to improve design technique for the vertical shaft of which design guide has not been proposed clearly. The deformation tendency of vertical shaft and distribution of the earth pressure around shaft were reviewed with both of theoretical earth pressure distribution suggested in design criteria and measured data which had been gained from 2 constructing shaft. The distribution of earth pressure applied on the vertical shaft was similar with the result of previous theory for the earth pressure proposed by Shin (2007). Moreover it was observed that asymmetric deformation and earth pressure around vertical shaft were caused by inhomogeneity and anisotropy of the ground. The asymmetric earth pressure ratio ($R_p$) in soil and weathered rock were divergent according to the shape ratio. In addition, it is more reasonable that the value of asymmetric earth pressure ratio ($R_p$) is considered less than 0.35 in the case of constructing shaft under rock.

  • PDF

Earth pressure on a vertical shaft considering the arching effect in c-𝜙 soil

  • Lee, In-Mo;Kim, Do-Hoon;Kim, Kyoung-Yul;Lee, Seok-Won
    • Geomechanics and Engineering
    • /
    • v.11 no.6
    • /
    • pp.879-896
    • /
    • 2016
  • A new earth pressure equation considering the arching effect in $c-{\phi}$ soils was proposed for the accurate calculation of earth pressure on circular vertical shafts. The arching effect and the subsequent load recovery phenomenon occurring due to multi-step excavation were quantitatively investigated through laboratory tests. The new earth pressure equation was verified by comparing the test results with the earth pressures predicted by new equation in various soil conditions. Resulting from testing by using multi-step excavation, the arching effect and load recovery were clearly observed. The test results in $c-{\phi}$ soil showed that even a small amount of cohesion can cause the earth pressure to decrease significantly. Therefore, predicting earth pressure without considering such cohesion can lead to overestimation of earth pressure. The test results in various ground conditions demonstrated that the newly proposed equation, which enables consideration of cohesion as appropriate, is the most reliable equation for predicting earth pressure in both ${\phi}$ soil and $c-{\phi}$ soil. The comparison of the theoretical equations with the field data measured on a real construction site also highlighted the best-fitness of the theoretical equation in predicting earth pressure.

A Simulation of Arching Earth Pressure Exerted on Vertical Shafts through Centrifuge Tests (원심모형실험에 의한 수직구 아칭토압 모사)

  • Lee, Dae-Soo;Kim, Kyoung-Yul;Hong, Sung-Yun;Kim, Yoo-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1073-1080
    • /
    • 2010
  • In this paper, the centrifuge model tests were conducted for the sake of measuring three dimensional arching earth pressure while two step excavation of the vertical shaft. The results of the centrifuge model tests were compared to newly suggested arching earth pressure equation proposed by Kim et al(2009) and two dimension earth pressure(Rankine). As the results, Measured arching earth pressure revealed about 35 percentages of two dimension earth pressure(Rankine) and almost same as that of newly suggested arching earth pressure equation.

  • PDF

Earth pressures acting on vertical circular shafts considering arching effects in c-${\phi}$ soils: I. Theory (c-${\phi}$ 지반에서의 아칭현상을 고려한 원형수직터널 토압: I. 이론)

  • Kim, Do-Hoon;Lee, Dea-Su;Kim, Kyung-Ryeol;Lee, Yong-Hee;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.2
    • /
    • pp.117-129
    • /
    • 2009
  • Several researches have been done to estimate the earth pressure on a vertical circular shaft considering three dimensional arching effect and verified them by conducting model tests. However, any equation suggested so far is not applicable in case of multi-layered soils and/or C-${\phi}$ soils. In this study, new equation for estimating the earth pressure acting on the vertical shaft in c-${\phi}$ soils is proposed. A parametric study is performed to investigate the significance of the cohesion when estimating the coefficient of earth pressure in C-${\phi}$ soils and estimating earth pressures in vertical shafts. A method which can estimate the earth pressure on vertical shafts in layered soils is also proposed by assuming a failure surface in layered soils and using the modified equation. This paper is Part I of companion papers focusing on the theoretical aspect of model developments; the experimental verification will be made in Part II.

Seismic lateral earth pressure analysis of retaining walls

  • Ismeik, Muhannad;Shaqour, Fathi
    • Geomechanics and Engineering
    • /
    • v.8 no.4
    • /
    • pp.523-540
    • /
    • 2015
  • Based on limit equilibrium principles, this study presents a theoretical derivation of a new analytical formulation for estimating magnitude and lateral earth pressure distribution on a retaining wall subjected to seismic loads. The proposed solution accounts for failure wedge inclination, unit weight and friction angle of backfill soil, wall roughness, and horizontal and vertical seismic ground accelerations. The current analysis predicts a nonlinear lateral earth pressure variation along the wall with and without seismic loads. A parametric study is conducted to examine the influence of various parameters on lateral earth pressure distribution. Findings reveal that lateral earth pressure increases with the increase of horizontal ground acceleration while it decreases with the increase of vertical ground acceleration. Compared to classical theory, the position of resultant lateral earth force is located at a higher distance from wall base which in turn has a direct impact on wall stability and economy. A numerical example is presented to illustrate the computations of lateral earth pressure distribution based on the suggested analytical method.

A study on the Vertical Earth Pressure in rigid buried pipe by numerical approach (강성매설관에 작용하는 연직토압에 관한 수치적 연구)

  • Park Sang-Won;Han Myung-Sik
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.661-666
    • /
    • 2005
  • In this Paper, to calculate vertical earth pressure affected from several factors in case of rigid buried pipe with cohesionless backfill soil. The result from PENTAGON 3D is compared with several equation's result such as the Janssen, Marston, Spangler, Handy's equation. Result of study shows that vertical earth pressure of each equation is affected by backfill width, backfill depth and wall friction. And vertical earth pressure is linearly increased with backfill depth and backfill width. Marston's equation and Handy's equation are overestimated and FEM(Finite Element method) analysis and Janssen's Silo equation are affected by more backfill depth than backfill width.

  • PDF

Earth Pressure on a Rigid wall due to Loads Condition and Distance (상재하중의 크기와 이격거리에 따른 강성벽체의 토압분포)

  • Oh, Bun-Jin;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.12
    • /
    • pp.51-60
    • /
    • 2010
  • Earth pressure due to gravity generally increases linearly with the depth, but the distribution of earth pressure due to surface load depends on the loading condition, the ground condition, and the boundary condition. In this study, the earth pressure on a rigid wall due to the vertical surface load was measured in experiments. Rigid wall was built in the model test box, and it was filled with homogeneous sandy ground (width 30 cm, height 88 cm, length 110 cm). Rigid wall was composed of 8 segments, which were tested on the two load cells. In the tests, we observed the distribution of the earth pressure on the rigid wall depending on the vertical surface load and it's location. According to the test results, the lateral earth pressure due to the vertical surface load showed its maximum value at a constant depth and decreased with the depth, to the negligible value at the critical depth. The critical depth and the depth at which lateral earth pressure reaches its maximum were not decided by the magnitude of the vertical surface load. They were dependant on the distance from the rigid wall.

Estimation of Earth Pressures Acting on Box Structures Buried in Ground (지중에 매설된 박스구조물에 작용하는 토압 산정)

  • Hong, Won-Pyo;Yun, Jung-Mann;Song, Young-Suk
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.2
    • /
    • pp.23-33
    • /
    • 2015
  • The earth pressure acting on underground structure was measured by application of the instrumentation system in the subway construction site constructed by the method of cut-and-cover tunnel. The measured earth pressure was compared with the earth pressure obtained from the existed theoretical equation, and the actual earth pressure diagram acting on the underground structure was investigated. As a result of investigation, the vertical earth pressure is mainly affected by the embankment height, and the lateral earth pressure is significantly affected by whether the existence of earth retaining structures or not. The measured vertical earth pressure is very similar to the theoretical earth pressure proposed by Bierbaumer. The measured lateral earth pressure is closed to the active earth pressure proposed by Rankine rather than the earth pressure at rest. The coefficient of earth pressure in soil deposit layer is about 0.35, and the coefficient in soft rock deposit layer is about 0.21. For design and construction the underground structures, therefore, it is reasonable estimation that the lateral earth pressure acting on structures installed in soil deposit layers is an average value between active earth pressure and earth pressure at rest. In rock deposit layers, the lateral earth pressure acting on structure is an active earth pressure only.

Vertical Earth Pressure on Buried Pipes in Ditches due to Fills (강설매설관에 작용하는 되메움토 연직토압)

  • Park, Sangwon;Do, Jongnam;Jung, Jongju;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • In this paper, vertical earth pressure by CANDE program is compared with that by some equations such as the equation by Janssen, Marston, Spangler, and Handy to calculate vertical earth pressure with respect to several factors acting on a rigid buried-pipe filled cohesionless soil. As a result of comparative analysis of vertical earth pressure with each equation, primary factors are affected by backfill width, backfill depth and wall friction. Moreover, vertical earth pressure is linearly increased with backfill depth and width from results of the finite element method. Handy's Equation is reasonable for finite element method while Marston equation is overestimated in case of the design of buried-pipe and box.

  • PDF