• Title/Summary/Keyword: vertical characteristic

Search Result 533, Processing Time 0.024 seconds

Structural Characteristic Analysis on the Hydrostatic Guide Way and Feeding System of a High-Precision Centerless Grinder for Machining Ferrules (페룰 가공용 초정밀 무심 연삭기의 유정압 안내면 및 이송계에 대한 구조 특성 해석)

  • Kim, Seok-Il;Park, Chun-Hong;Cho, Soon-Joo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.896-903
    • /
    • 2004
  • This paper proposes the structural characteristic analysis and evaluation on the hydrostatic guide way and feeding system of a high-precision centerless grinder for machining ferrules. In order to realize the required accuracy of ferrules with sub-micron order, the axial stiffness and motion accuracy of feeding system have to become higher level than those of existing centerless grinders. Under these points of view, the physical prototype of feeding system composed of steel bed, hydrostatic guide way and ballscrew feeding mechanism is designed and manufactured for trial. Experimental results show that the axial and vertical stiffnesses of the physical prototype are very low as compared with those design values. In this paper, to reveal the cause of these stiffness difference, the structural deformations on the virtual prototype of feeding system are analyzed based on the finite element method under experimental conditions. The simulated results illustrate that the deformation of front ballscrew support-bearing bracket is the main cause of reduction in the axial stiffness of feeding system, and the deflection of bed structure and the bending deformation of hydrostatic guide rails are the main causes of reduction in the vertical stiffness of feeding system.

Study on electro optic characteristic of pattern free vertical alignment (PFVA) mode using the uv curable reactive mesogen (RM) (광경화성 단분자를 이용한 pattern free vertical alignment 모드의 전기 광학 특성 연구)

  • Cho, In-Young;Hwang, Seong-Jin;Kim, Sung-Min;Hwang, Ji-Hye;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04a
    • /
    • pp.45-46
    • /
    • 2008
  • The conventional biased vertical alignment (BVA) mode has several advantages such as rubbing- and protrusion-free, wide-viewing angle and stable LC dynamics against external pressure. However manufacturing process of BVA mode is difficult task because the pixel and bias electrode signal are different in each frame. To solve this problem, we investigated the pattern free vertical alignment (PFVA) by using the UV-curable reactive mesogen (RM), in which the LC molecules were made to be pre-tilted. Eventually transmittance and response time in PFVA mode were found to be improved as compared to BVA mode.

  • PDF

A Study on the Effect of Consolidation according to the depth of Vertical Drains (Drain 타설심도에 따른 압밀효과에 관한 연구)

  • Son, Dae-San;Jang, Jeong-Wook;Park, Sik-Choon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1187-1194
    • /
    • 2006
  • This study analyzed characteristics of soft ground consolidation according to depths of vertical drain. As the result, when the depth ratio of vertical drains (L/D) were 0.5, 0.7, and 1.0, consolidation characteristics were similar up to 70% in consolidation degree under one-dimensional drain condition. However, above this degree, consolidation speed became slower as L/D became smaller. Two-dimensional drain condition also showed a similar tendency, but when L/D was 1.0, the consolidation speed was relatively higher.

  • PDF

Characteristic Analysis of The Vertical Trench Hall Sensor using SOI Structure (SOI 구조를 이용한 수직 Hall 센서에 대한 특성 연구)

  • 이지연;박병휘
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.4
    • /
    • pp.25-29
    • /
    • 2002
  • We have fabricated a vertical trench Hall device which is sensitive to the magnetic field parallel to the sensor surface. The vertical trench Hall device has been built on SOI wafer which is produced by silicon direct bonding technology using bulk micromachining, where buried $SiO_2$ layer and surround trench define active device volume. Sensitivity up to 150 V/AT has been measured.

  • PDF

A analysis on the output characteristic of the horizontal and vertical wind turbine related to wind velocity (풍속에 따른 수평형과 수직형 풍력발전기의 출력특성에 관한 분석)

  • Choi Jang-Kyun;Cha In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.191-193
    • /
    • 2006
  • The various wind turbines have been designed and developed for the century. The precision design of the blade and turbine system considering the wind circumstance is required for the high efficiency. In this paper, we investigated the output characteristics of the horizontal and vertical wind turbine related to the wind velocity. Furthermore we will intend to design the wind turbine blade adapted the urban wind circumstance.

  • PDF

Evaluation of seismic performance of mid-rise reinforced concrete frames subjected to far-field and near-field ground motions

  • Ansari, Mokhtar;Ansari, Masoud;Safiey, Amir
    • Earthquakes and Structures
    • /
    • v.15 no.5
    • /
    • pp.453-462
    • /
    • 2018
  • Damages to buildings affected by a near-fault strong ground motion are largely attributed to the vertical component of the earthquake resulting in column failures, which could lead to disproportionate building catastrophic collapse in a progressive fashion. Recently, considerable interests are awakening to study effects of earthquake vertical components on structural responses. In this study, detailed modeling and time-history analyses of a 12-story code-conforming reinforced concrete moment frame building carrying the gravity loads, and exposed to once only the horizontal component of, and second time simultaneously the horizontal and vertical components of an ensemble of far-field and near-field earthquakes are conducted. Structural responses inclusive of tension, compression and its fluctuations in columns, the ratio of shear demand to capacity in columns and peak mid-span moment demand in beams are compared with and without the presence of the vertical component of earthquake records. The influences of the existence of earthquake vertical component in both exterior and interior spans are separately studied. Thereafter, the correlation between the increase of demands induced by the vertical component of the earthquake and the ratio of a set of earthquake record characteristic parameters is investigated. It is shown that uplift initiation and the magnitude of tensile forces developed in corner columns are relatively more critical. Presence of vertical component of earthquake leads to a drop in minimum compressive force and initiation of tension in columns. The magnitude of this reduction in the most critical case is recorded on average 84% under near-fault ground motions. Besides, the presence of earthquake vertical components increases the shear capacity required in columns, which is at most 31%. In the best case, a direct correlation of 95% between the increase of the maximum compressive force and the ratio of vertical to horizontal 'effective peak acceleration (EPA)' is observed.

Analysis of Permeability Characteristic for Z type Steel Sheet Pile by Field Test (현장시험 시공을 통한 Z형 강널말뚝의 현장차수특성 분석)

  • 이용수;정하익;홍승서;이광범;김상진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.325-330
    • /
    • 2000
  • In general steel sheet pile use the containment system, vertical barrier systems for waste disposal and landfill purposes, roads in excavation which have a more permanent character or temporary structure. The sheet pile joints between section of the wall are sealed with a filter material arid the resistance to seepage is a function of the type of material employed. The aim of this paper is to review a characteristic of permeability for Z type sheet pile by field test in various condition.

  • PDF

Infiltration Characteristics for Unsaturated Residual Soil (화강풍화토의 불포화 침투특성에 관한 연구)

  • 김영욱;김도형;성상규;이인모
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.147-152
    • /
    • 2001
  • This study investigated one-dimensional vertical infiltration to an unsaturated residual soil by numerical solutions, FDM. In order to estimate the parameters needed for numerical analysis, tire soil-water characteristic curve(SWCC) of Shinnae-dong soil, one of the most typical residual soils in Korea, were experimentally obtained. Then, the statistical analysis for obtaining the SWCC was performed. The numerical solution to the linearized governing equation for unsaturated groundwater flow provides the infiltration characteristics for the unsaturated residual soil represented by transient pressure profiles and water contents profiles.

  • PDF

Teaching-Learning Methods articulated with mathematics in middle school (중학 수학의 연계적인 교수 학습 방법에 관한 연구 - 함수 영역을 중심으로)

  • 장이채;김태균;정인철;송주현
    • Journal of the Korean School Mathematics Society
    • /
    • v.6 no.2
    • /
    • pp.21-37
    • /
    • 2003
  • In this paper, we improved, compared and analyzed the articulation of school mathematics. We also tried to form the theoretical basis of school mathematics by classifying and considering the articulation into vertical articulation and horizontal articulation depending on the meaning, and give an actual help. The articulation of school mathematics until now has been focused on a study of vertical articulation according to the macroscopic characteristic of mathematics, but now a study of the horizontal articulation as well as the vertical articulation should be done in consideration of the micro characteristics of mathematics and various realities of life by modifying a syllabus of the function unit and by using internet homepage. Thus, we structurally divided the articulation into vertical articulation and horizontal articulation, analyzed mathematical activities and presented actual models of each representative learning activity for smooth teaching in schools through the function unit.

  • PDF