• 제목/요약/키워드: vertical axis wind turbine

검색결과 105건 처리시간 0.04초

Influence of Reynolds Number and Scale on Performance Evaluation of Lift-type Vertical Axis Wind Turbine by Scale-model Wind Tunnel Tests

  • Tanino, Tadakazu;Nakao, Shinichiro;Miyaguni, Takeshi;Takahashi, Kazunobu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권2호
    • /
    • pp.229-234
    • /
    • 2011
  • For Lift-type Vertical Axis Wind Turbine (VAWT), it is difficult to evaluate the performance through the scale-model wind tunnel tests, because of the scale effect relating to Reynolds number. However, it is beneficial to figure out the critical value of Reynolds number or minimum size of the Lift-type VAWT, when designing this type of micro wind turbine. Therefore, in this study, the performance of several scale-models of Lift-type VAWT (Reynolds number : $1.5{\times}10^4$ to $4.6{\times}10^4$) was investigated. As a result, the Reynolds number effect depends on the blade chord rather than the inlet velocity. In addition, there was a transition point of the Reynolds number to change the dominant driving force from Drag to Lift.

수직형 풍력터빈 익형의 동특성 분석 (Study for Dynamic Stall Characteristics of Vertical Axis Wind Turbine Airfoil)

  • 김철완;조태환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.478-481
    • /
    • 2009
  • As a first step for aerodynamic analysis of vertical axis wind turbine, dynamic stall characteristics of airfoil was investigated. Dynamic stall of wind turbine airfoil is caused by severe variation of angle of attack and relative velocity of flow around airfoil. Angle of attack and relative velocity can be expressed with tip speed ratio. Variation of angle of attack is strongly dependent on the tip speed ratio. For tip speed ratio, 1.4 and free stream velocity, 15m/s, dynamic stall characteristics of wind turbine airfoil is compared with those of oscillating airfoil having same angle of attack variation.

  • PDF

Numerical optimization of a vertical axis wind turbine: case study at TMU campus

  • Mirfazli, Seyed Kourosh;Giahi, Mohammad Hossein;Dehkordi, Ali Jafarian
    • Wind and Structures
    • /
    • 제28권3호
    • /
    • pp.191-201
    • /
    • 2019
  • In this paper, the aerodynamic analysis of a vertical axis wind turbine was carried out by CFD approach to optimize the turbine performance. To perform numerical simulation, SST-Transition turbulence model was used, which demonstrated more precise results compared to non-transition models. A parametric study was conducted to optimize the VAWT performance based on the selected model. The investigation of pitch angle changes showed that the highest power produced by the turbine occurs at $2^{\circ}$ angle. Considering the effect of the rotor's arm junction to the airfoil showed that by increasing the distance of the junction from the edge of the airfoil from 25 cm to 40 cm, the power of the turbine increases by 60%. However, further increase in this distance results in power decrease. Based on the proposed numerical model, a case study was conducted to consider the installation of four VAWTs in the southwest corner of the medical science building at TMU campus with a height of 42m. The results of the simulation showed that 8.27 MWh energy is obtainable annually.

300W급 Savonius 형 수직축 풍력발전기의 유동소음특성에 관한 수치적 연구 (Numerical analysis on the flow noise characteristics of 300W Savonius-type vertical-axis wind turbines)

  • 김상현;이광세;정철웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.725-730
    • /
    • 2012
  • In this paper, flow noise characteristics of Savonius-type vertical-axis wind turbines are numerically investigated using hybrid CAA techniques. High frequency harmonics as well as BPF components are identified in the predicted noise spectra from a Savonius wind turbine. As the BPF components belong to infrasound, the higher harmonic components affects human response dominantly. Further analysis is performed to investigate the reason causing the higher frequency harmonic noise by changing operational conditions of a Savonius wind turbine. Based on this result, it is revealed that the frequency of higher harmonic components is determined by the radius of blades and angular velocity of Savonius wind turbine.

  • PDF

도로 중앙분리대용 후드장식형 수직축풍력발전기 연구 (A Study of Hood-Type Vertical Axis Wind Turbine Embedded to Highway Median Strip)

  • 이종조;임재규
    • 조명전기설비학회논문지
    • /
    • 제27권1호
    • /
    • pp.24-34
    • /
    • 2013
  • This paper introduces the study of hood-type wind turbine embedded on highway median strip. Recently, many studies are being made to apply to small wind turbine in city. This study is wind turbine producing electricity generated from the wind by running cars. In order to analyze wind generated by running cars, we measured experiments using running cars and buses. Also, using CFD and interpreter program, we analysis wind turbines performance and applied to the twist-sabonius blade. This wind turbine attached to safety lamp on the road is produced to use electricity generated through the wind tunnel experiment. In this paper results, this wind turbine system is expected to produce the power source installed the heat ray and safety lamps on the road.

Aerodynamic analysis and control mechanism design of cycloidal wind turbine adopting active control of blade motion

  • Hwang, In-Seong;Lee, Yun-Han;Kim, Seung-Jo
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제8권2호
    • /
    • pp.11-16
    • /
    • 2007
  • This paper describes the cycloidal wind turbine, which is a straight blade vertical axis wind turbine using the cycloidal blade system. Cycloidal blade system consists of several blades rotating about an axis in parallel direction. Each blade changes its pitch angle periodically. Cycloidal wind turbine is different from the previous turbines. The wind turbine operates with optimum rotating forces through active control of the blade to change pitch angle and phase angle according to the changes of wind direction and wind speed. Various numerical experiments were conducted to develop a small vertical axis wind turbine of 1 kW class. For this numerical analysis, the rotor system equips four blades consisting of a symmetric airfoil NACA0018 of 1.0m in span, 0.22m in chord and 1.0m in radius. A general purpose commercial CFD program, STAR-CD, was used for numerical analysis. PCL of MSC/PATRAN was used for efficient parametric auto mesh generation. Variables of wind speed, pitch angle, phase angle and rotating speed were set in the numerical experiments. The generated power was obtained according to the various combinations of these variables. Optimal pitch angle and phase angle of cycloidal blade system were obtained according to the change of the wind direction and the wind speed. Based on data obtained from the above analysis, control device was designed. The wind direction and the wind speed were sensed by a wind indicator and an anemometer. Each blades were actuated to optimal performance values by servo motors.

소형 수직축 풍력발전기 풍동실험시 폐쇄율의 영향 (Effect of Blockage Ratio on Wind Tunnel Testing of Small Vertical-Axis Wind Turbines)

  • 정회갑;이승호;권순덕
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.98-106
    • /
    • 2014
  • The effect of blockage ratio on wind tunnel testing of small vertical-axis wind turbine has been investigated in this study. Height and rotor diameter of the three blades Darrieus vertical axis wind turbine used in present test were 0.4m and 0.35m respectively. We measured the wind speeds and power coefficient at three different wind tunnels where blockage ratio were 3.5%, 13.4% and 24.7% respectively. The test results show that the measured powers have been strongly influenced by blockage ratio, generally increased as the blockage ratio increases. The maximum power at higher blockage ratio has been obtained at relatively high tip speed ratio compared with that at low blockage ratio. The measured power coefficients under high blockage ratio can be improved from proper correction using the simple correction equation based on blockage factor. In present study, the correction error for power coefficient can be less than 5%, however correction effectiveness reveals relatively poor at high blockage ratio and low wind speed.

200 W급 자이로밀형 수직축 풍력터빈 로터 블레이드 형상설계 및 유동해석 (Shape design and flow analysis on a 200W-class gyromill type vertical axis wind turbine rotor blade)

  • 조우석;김현수;최영도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권2호
    • /
    • pp.170-177
    • /
    • 2013
  • 본 연구는 200 W급 자이로밀형 소형 수직축 풍력터빈 로터 블레이드의 형상설계 및 유동해석에 의한 성능 검토에 관한 내용을 정리한 것이다. 2차원 형상의 로터 블레이드에 대하여 단일유관이론을 적용하여 설계하였으며, 설계 결과에 대해서 2차원 수치유동해석을 수행하여 해석결과의 검토로부터 3차원 로터 블레이드 기본 형상을 결정하고, 3차원 수치유동해석을 통하여 풍력터빈 로터 블레이드의 형상 결정 및 성능 검토를 하였다. 본 연구의 결과로부터 상대적 저풍속에서 200 W급 자이로밀형 수직축 풍력터빈 로터 블레이드의 형상을 도출하였고, 수치유동해석으로부터 정격출력 200 W를 확보할 수 있음을 확인하여, 본 연구에서 적용한 설계법의 타당성을 확보하였다.

수직축 풍력터빈 성능개선에 관한 실험적 연구 (An Experimental Study on the Performance of the Vertical-Axis Wind Turbine)

  • 김병국;김영호;송우석;이승배;남상규;김사만
    • 한국유체기계학회 논문집
    • /
    • 제10권3호
    • /
    • pp.17-24
    • /
    • 2007
  • This paper presents the design procedure of a vertical wind turbine named jet-wheel-turbo turbine and the numerical and experimental verifications. The design parameters such as the rotor inlet angle, the diameter-to-hub ratio, the inlet guide outlet angle and the solidity were optimized to maximize the energy transfer, and to further increase the turbine efficiency by applying the side guide vane and the side opening to the rotor. The maximum power coefficient of 0.59, which is much higher than the ever-designed three-bladed horizontal turbines, was experimentally obtained when the optimal inlet- and side-guide vanes were installed and both sides of the rotor were 80% opened. The maximum power coefficients occur at the tip speed ratio ranging between 0.6 and 0.7. This vertical-axis turbine model can be applied to the large-scale power generation system with the speed and torque control algorithm for the specified wind characteristics.