• Title/Summary/Keyword: vertical and horizontal transmission

Search Result 95, Processing Time 0.025 seconds

Design of Three-stacked Microstrip Patch Array Antenna Having Tx/Rx Feeds For Satellite Communication (위성통신을 위한 송수신 겸용 삼중 적층 마이크로스트립 패치 배열 안테나 설계)

  • Park, Ung-Hee;Noh, Haeng-Sook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.5
    • /
    • pp.853-859
    • /
    • 2007
  • This paper presents a microstrip patch array antenna having transmission feed and reception feed for satellite communication in the Ku band. In this paper, the element of the patch array antenna is a three-stacked structure consisting of one radiation patch and two parasitic patches for high gain and wide bandwidth characteristics. To obtain higher gain, the unit elements are expanded into a $1{\times}8$ may using a mixture of series and parallel feeds. The proposed antenna has horizontal polarization for the Rx band and vertical polarization for the Tx band. To verify the practicality of this antenna, we fabricated a three-stacked patch array antenna and measured its performance. The gain of the array antenna in the Rx and Tx bands exceeds 17 and 18 dBi, respectively. The impedance bandwidth is over 10 % in both bands. The cross-polarization level is below -25 dB, and the sidelobe level is below -9.4 dB.

Development and Clinical Evaluation of Wireless Gyro-mouse for the Upper Extremity Disabled to Use Computer (상지장애인의 컴퓨터 사용을 위한 무선 자이로마우스의 개발 및 임상평가)

  • Han Ha-Na;Song Eun-Beom;Kim Chul-Seung;Heo Ji-Un;Eom Gwang-Moon
    • Science of Emotion and Sensibility
    • /
    • v.9 no.2
    • /
    • pp.93-100
    • /
    • 2006
  • This paper aims at the development and clinical evaluation of the wireless gyro-mouse system. The wireless gyro-mouse system is a computer interface with gyro-sensor and wireless communication, for the patients with upper-extremity disabled from the traffic accident or stroke to use the computer software i.e. internet browser. In the development, we focused on, firstly, to make the system wireless for the patients to manipulate the mouse easily even on the bed or wheelchair, secondly, to insert the gyro-sensor into a headband for easy don-and-doff and aesthetic appearance, thirdly, to devise a click switch in case of $C5{\sim}C6$ patients and a head nodding detection in case of C4 patients for sending click message to computer operating system. We performed evaluation experiment for patients with upper-extremities disabled from spinal cord injury. The results show that the displacement error of the cursor position against the target position during linear (vertical/horizontal) movement manipulation decreased with trial number. The click rate per minute also increased with trial number. This indicates the developed wireless gyro-mouse system would be more useful to the patients with repetitive use.

  • PDF

Monitoring of nervous necrosis virus in fertilized eggs of walleye pollock (Gadus chalcogrammus) (명태(Gadus chalcogrammus) 수정란에서 신경괴사증바이러스(nervous necrosis virus) 모니터링)

  • Nam, U-Hwa;Lee, Jong-Hyuk;Kim, Mi-Ri;Jang, Su-Rim;Yoon, Do-Hyun;Seo, Joo-Young;Kwon, O-Nam;Kim, Jeong-Ho
    • Journal of fish pathology
    • /
    • v.31 no.1
    • /
    • pp.9-13
    • /
    • 2018
  • We previously monitored nervous necrosis virus (NNV) in brain samples of artificially produced walleye Pollock (Gadus chalcogrammus) seedlings, with a low prevalence (1.8%, 1/55) but no clinical symptoms. Given that this virus is considered one of the most serious viral threats for almost all marine aquaculture fish species and characterized by both vertical and horizontal transmission, it would be interesting to monitor NNV in the fertilized eggs as well. We collected fertilized walleye pollock eggs from the farms located in Goseong during January to March, 2017. Approximately 50 mg of eggs were periodically taken from 4 each different batches, and 37 different pooled sample sets in total were made during sampling period. RNA was extracted from the eggs by using Trizol and cDNA was synthesized for RT-PCR for detecting NNV. Primers and PCR conditions are the same as previously described. As a result, NNV was not detected from any of the sample sets by one step PCR (0%, 0/37), suggesting NNV may not be a threat in walleye pollock aquaculture in Korea at present time. However, continuous monitoring for NNV should be conducted because introducing a new species into aquaculture industry involves potentials of disease outbreak and NNV is already known to cause outbreaks in gadoid fishes.

The Site Effect of the Broadband Seismic Stations in Korea (국내 광대역 지진 관측소의 부지효과)

  • Wee, Soung-Hoon;Kim, Sung-Kyun
    • Economic and Environmental Geology
    • /
    • v.41 no.2
    • /
    • pp.225-242
    • /
    • 2008
  • The site effect for 23 broadband seismic stations in the southern Korean Peninsula was estimated by using the spectral ratio of coda waves. In principle, the site effect means the pure amplification below the station excluding effects of seismic source and attenuation in the wave transmission. However, the site effect determined in this study is equivalent with the relative site amplification factor to the mean amplification for all stations. A total of 500 three-component seismograms from 35 earthquakes, of which magnitude ranged from 2.5 to 5.1 occurred from January, 2001 to January, 2007 was used to obtain the site amplification factor. The site amplification factors were estimated for the frequency bands centered at 0.2, 0.5, 1, 2, 5, 10, 15, and 20 Hz. It was found that the factors for two horizontal components of transverse and radial records were concordant with each other in the all frequency bands. However, the factor for the vertical component was found to be systematically lower than those for two horizontal components. The factors obtained in the low frequency band below 2 Hz ranged from 0.5 to 1.5 in all seismic stations except for KMA and KIGAM stations in Bagryeongdo (BRD1 and BRD2) of which factor showed high value above 1.5. Some stations such as SEO, SNU, HKU, NPR, and GKPI showed high value above 1.5 in the high frequency band from 5 to 20 Hz. Especially, the factors of GKP1 station represented extremely high value ranging from 1.8 to 7.8. Also, the factors for stations of KWJ, SND, and ULJ showed low value below 0.5. The spatial distribution for the relative amplification factor represented a tendency of being approximately lower in north-eastern area than south-western area in the southern Korean Peninsula.

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF