• 제목/요약/키워드: vernier

검색결과 114건 처리시간 0.03초

개인 트레이의 설계와 인상채득방법이 의치 변연의 형태에 미치는 영향에 관한 연구 (THE EFFECT OF INDIVIDUAL TRAY DESIGN AND IMPRESSION METHOD ON THE BORDER EXTENSION AND CONTOUR OF DENTURE)

  • 이정우;오상천;진태호
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.13-23
    • /
    • 1995
  • The purpose of this study is to inquire about the effects of individual tray design and impression method on the border extension and contour of denture. 10 students at the dentistry college who have normal occlusion and symmetric facial form and normal facial muscle activity were selected. The tray was designed three types (large, medium, small tray). After border molding was done by dentist and operator, final impression was taken. The length of impression body and width of border were measured by a vernier caliper on the cast. The obtained results were as follows : 1. As the tray border was shortened, the length of impression body and width of border was short (P<0.01). 2. When the impression was taken with the small tray, the length of impression body was short in passive border molding than active border molding. 3. When the medium tray was used, the width of impression body was short in passive border molding than active border molding.

  • PDF

전동차용 접지브러쉬 편중마모에 대한 해석 (Analsis of Preponderant Wear of Earth Brush for an Electrical Multiple Units(EMUs))

  • 박병섭;구정서;김길동
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.356-361
    • /
    • 2005
  • Earth brush for electrical multiple units(EMUs) is a device through which the current of the EMU load's consumed power fed from the DC 1,500V overhead line (or from the AC 25.000V catenary) flows via axle to the rail(ground) and which prevents the electric corrosion of the axle bearings by preventing the current flow to the axle bearings caused by electric potential from the magnetic field when the bearings rotate together with the earthing function when a thunderbolt falls or a surge comes. The earth brush wear rates among cars, however, shows quite differences when the earth brushes after being separated from the holders are measured with vernier callipers every 6 months of maintenance period. Main causes of the earth brush wear are divided as mechanical, electric arc and electrical one, and the factors can be running speed, current, harmonics, connection state. spring tension, earth brush material, lubricant and so on. but only the earth brushes of the motor(M1) car show the highest wear rate and moreover maintenance difficulty occurs because of the wear rate differences among e earth brushes in one holder. The reason for these preponderant wear comes from the design concept of making preponderant current flow to some particular earth brushes and moreover the heat generated by the harmonics when the inverter starts to operate accelerate the wear. By defining these causes through experiments. I hope that the found results would be helpful for the future EMU design, safety, economy and maintenance.

  • PDF

광섬유 피드 리트로마운트형 분광계 (AN OPTICAL FIBER FEED LITTROW-MOUNTED SPECTROMETER)

  • 배지훈;송재원;윤태석
    • 천문학논총
    • /
    • 제27권3호
    • /
    • pp.87-93
    • /
    • 2012
  • A low-dispersion fiber feed Littrow-mounted grating spectrometer for education was designed and fabricated. The dispersion element is a reflective type blazed grating Edmundoptics NT 46-075 (spatial frequency 600 lines/mm, dimension $30mm{\times}30mm$, blazed angle 8.6 degree). The optical fiber coupler module for optical guiding from telescope to spectrometer is composed of a multi-mode FC connector - FC connector optical fiber patch cord (core/cladding diameter $50{\mu}m/125{\mu}m$) and two 1.25" throw-tube couplers. The lens for collimating and imaging is a general purpose focal length 50 mm camera lens (f/1.8). The device for optical path control is a rectangular prism (size $25mm{\times}25mm$). The imaging camera sensor is a Meade DSI Pro 2 CCD sensor (black and white, $752{\times}582$ pixels and pixel size $8.3{\mu}m{\times}8.6{\mu}m$). Softwares for data logging and analysis consist of Meade Autostar Suite, NIH imagej and Vernier Logger Pro 3. The wavelength coverage range of the spectrometer is 205 nm at central wavelength 550 nm. The wavelength resolution is 1.7 nm.

Anatomical variations and developmental anomalies of the thyroid gland in Ethiopian population: a cadaveric study

  • Dessie, Meselech Ambaw
    • Anatomy and Cell Biology
    • /
    • 제51권4호
    • /
    • pp.243-250
    • /
    • 2018
  • Because of its embryonic origin, the thyroid gland is predisposed to multiple anatomical variations and developmental anomalies. These include the pyramidal lobe, the origin of levator glandular thyroidae, the absence of the isthmus, ectopic thyroid, accessory thyroid tissues, etc. These anatomical variations are clinically significant to surgeons, anatomists, and researchers. The present study was designed to report anatomical variations and developmental anomalies of the thyroid gland in Ethiopian population. The study was conducted on 40 cadavers used for routine dissection classes. The thyroid gland was exposed and observed for any variations and developmental anomalies. The length, width, and thickness of the lobes were measured using a vernier caliper. Differences in the incidence of pyramidal lobe and absence of the isthmus between sexes were tested using a Pearson chi-square test. The mean length, width, and thickness of the right lobe were 4.24 cm, 1.8 cm, and 1.6 cm, respectively, whereas it was 4.08 cm, 1.8 cm, and 1.6 cm, respectively for that of the left lobe. The pyramidal lobe was noted in 52.5% of the cadavers. The levator glandulae thyroidae were prevalent in 40% of the cadavers. The isthmus mainly overlies the 2nd to 4th tracheal rings and was absent in 7.5% of the cadavers. Accessory thyroid tissue and double pyramidal lobes were noted in 2.5% of the cadavers. Most of the variations of the thyroid gland were seen frequently in female but it was not statically significant. Different clinically important and rare variations of the thyroid gland were found.

전완부의 골도분촌법에 관한 연구 (A Study on Bone Proportional Measurement of the Forearm)

  • 민원홍;양제윤;양기영;채한;이병렬
    • Korean Journal of Acupuncture
    • /
    • 제35권4호
    • /
    • pp.226-233
    • /
    • 2018
  • Objectives : The purpose of this study was to establish an accurate and effective method of locating acupoints of the forearm by studying bone proportional measurement. Methods : A total of 60 volunteers, 30 men and 30 women, participated in this study. 7 parts of the body were measured by a soft ruler or digital vernier calipers. The cun of the upper limb was calculated and analyzed. And the results were compared with the standard cun. Results : The bone proportional cun of the forearm based on height and femur was close to 11. It was different from the standard 12.5, 12 or 10. The cun of the forearm by thumb or finger width measurement was different from the standard too. Conclusions : We suggest that locating acupoints of the forearm needs to be done based on 11 cun. The confusion on locating acupoints of the forearm will be reduced by reflecting the result of the actual measurement.

Effects of a Complex Exercise Program on the Distance between Knees and Balance in Individuals in their 20s with Genu Varum

  • Jeong, Beomcheol;Yoo, Kyungtae
    • 국제물리치료학회지
    • /
    • 제11권4호
    • /
    • pp.2244-2252
    • /
    • 2020
  • Background: Thera-Band, Narrow squats, Kinesiology taping helps in the reduction of loading on the knee joints. Despite the fact that the varus knee negatively affects the alignment of the lower extremities, most of the studies have analyzed each independently. Objectives: To investigate the effects of a complex exercise program consisting of elastic band exercises and squat exercises on the distance between the inner knees and balance in young adults with genu varum. Design: A cluster randomized controlled trial. Methods: The complex exercise group performed resistance exercises using an elastic band. The taping group used kinesiology tape on the vastus lateralis and biceps femoris. To select those to be included in the study, we measured the distance between the knees using digital Vernier calipers and to measure the balance ability, we used a balance training system. The data were analyzed with the independent t-test and paired t-test. Results: The study indicated a significant difference in the distance between the knees between the two groups, but no significant differences in the dynamic balance between the groups. Also, the static balance comparison between the groups according to the intervention method included the trace length, C90 area, C90 angle and velocity. There were no significant differences in the static balance between the groups. In addition, the complex exercise program was more effective than taping. Conclusion: The results of this study demonstrate that the complex exercise program and taping decrease the between both the knee and increase the balance.

Morphometrical Study of Uncinate Processes and Vertebral Body of Cervical Spine

  • Lee, Tae-Hoon;Kim, Sang-Jin;Chung, In-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권5호
    • /
    • pp.247-252
    • /
    • 2012
  • Objective : The anatomical knowledge is the most important and has a direct link with success of operation in cervical spine surgery. The authors measured various cervical parameters in cadaveric dry bones and compared with previous reported results. Methods : We made 255 dry bones age from 19 to 72 years (mean, 42.3 years) that were obtained from 51 subjects in 100 subjects who donated their bodies. All measurements from C3-C7 levels were made using digital vernier calipers, standard goniometer, and self-made fix tool for two different cervical axes (canal and disc setting). We classified into 4 groups (uncinate process, vertebral body, lamina, and pedicle) and measured independently by two neurosurgeons for 28 parameters. Results : We analyzed 23970 measurements by mean value and standard deviations. In comparing with previous literatures, there are some different results. The mean values for uncinate process (UP) width ranged from 5.5 mm at C4 and 5 to 6.3 mm at C3 and C7 in men. Also, in women, the mean values for UP width ranged from 5.5 mm at C5 to 6.3 mm at C7. C7 was widest and C5 was most narrow than other levels. The antero-posterior length of UP tended to increase gradually from C3 to C6. The tip way, tip distance, and base distance of UP also showed increasing pattern from C3 to C7. Conclusion : These measurements can provide the spinal surgeons with a starting point to address bony architectures surrounding targeted soft tissues for safeguard against unintended damages during cervical operation.

미세전류전기자극이 흰쥐의 창상치유에 미치는 영향 (The Effect of Microcurrent Stimulation on Wound Healing in Rat)

  • 오혜진;김정우;박장성
    • 대한임상전기생리학회지
    • /
    • 제6권1호
    • /
    • pp.43-55
    • /
    • 2008
  • The purpose of this study was to investigate the effect of microcurrent stimulation intensity($50{\mu}A,\;100{\mu}A,\;300{\mu}A$ - 5 pps pulse frequency was same) on wound healing in rat. Sixty male Korean rats were randomly divided into 4 groups of 15 for 4 different treatment protocols(none-control group, $50{\mu}A,\;100{\mu}A,\;300{\mu}A$ experimental groups). Experimental 20 mm linear wound were made and all animals in the experimental groups were received microcurrent stimulation once a day for 20 minutes until sacrifice days(1st day, 3rd day, 6th day). A vernier caliper was used to measure a wound healing length and an optical microscope was used to determine any histological changes. The repeated measures two-way ANOVA was used for statistical differences in wound healing length. Experimental results were as follows: 1. In the examination with the naked eye, all groups showed similar changes until 1st day. But from 3rd day, a little intercellular fluid soaked through wound region in control group. In experimental groups, little intercellular fluid soaked through wound region, and swelling and redness did not appear. 2. Wound length of experimental $50{\mu}A$ group was significantly decreased than control group(p<0.001). And in the aspect of application period, wound length was significantly decreased in 3th, 6th day than 1st day and 6th day than 3th day (p<0.001). In conclusion, it has been found that the microcurrent stimulation had a positive effect on wound healing. And $50{\mu}A$ stimulation intensity was more effective than other intensities($100{\mu}A,\;300{\mu}A$) in wound healing. Also, low-intensity microcurrent stimulation was more effective on the purpose of wound healing.

  • PDF

Localization of the Mental and Infraorbital Foramen with related to the Soft-tissue Landmarks

  • Lee, Yun-Ho;Lee, Myoung-Hwa;Yu, Sun-Kyoung;Jeong, Goo-Soo;Kim, Do-Kyung;Kim, Heung-Joong
    • International Journal of Oral Biology
    • /
    • 제37권1호
    • /
    • pp.25-29
    • /
    • 2012
  • During maxillofacial surgery, the infraorbital and mental nerves are blocked at eac foramen to induce local anesthesia. This study examined the relative locations of the infraorbital foramen (IOF) and mental foramen (MF) based on softtissue landmarks. Twenty-eight hemifacial cadavers were dissected to expose the IOF and MF. The distances between the bilateral IOFs, the bilateral MFs, the alae of the nose (alares), and the corners of the mouth (cheilions) were measured directly on cadavers by using a digital vernier caliper. The vertical and horizontal distances of the IOF and MF relative to the alare and cheilion were measured indirectly on digital photographs using Adobe Photoshop (Adobe, CA, USA). The distance between the bilateral IOFs ($58.09{\pm}4.04mm$) was longer than the distance between the bilateral MFs ($50.32{\pm}1.93mm$). The distances between the bilateral alares and cheilions were $41.22{\pm}3.44mm$ and $58.43{\pm}6.62mm$, respectively. The IOF was located $12.92{\pm}3.75mm$ superior and $7.88{\pm}2.56mm$ lateral to the alare, and the vertical angle (Angle 1) between these structures was $31.67{\pm}13.36^{\circ}$ superolaterally. The MF was located $21.83{\pm}3.26mm$ inferior and $5.56{\pm}3.37mm$ medial to the cheilion, and the vertical angle (Angle 2) between these structures was $14.05{\pm}10.12^{\circ}$ inferomedially. In conclusion, these results provide more detailed information about the locations of the IOF and MF relative to soft-tissue landmarks.

디지털 이미지 처리 기법을 이용한 골재입자의 형상 분류 (Particle Shape Evaluation of Aggregate using Digital Image Process)

  • 황택진;조재윤;이관호;송용선
    • 한국방재학회 논문집
    • /
    • 제9권4호
    • /
    • pp.53-59
    • /
    • 2009
  • 본 논문에서는 체분석이 불가능한 일반토사 및 조립토 입자의 입도분포 특성을 디지털 이미지 처리기법을 적용하여 분석하는 방법을 제안하였다. 디지털 이미지 처리 기법은 골재의 표면거칠기 및 형상계수 등의 정량적인 분석에 적합한 것이다. 연구에 사용된 골재입자는 주문진 표준사, 해양골재 2종, 쇄석골재 2종 등이 이용되었다. 해변자갈 I, II의 형상계수는 $0.35{\sim}0.54$, 쇄석 I은 0.74의 범위로 박편 형태의 편평상으로 나타나는데 비해 주문진 표준사의 입자의 모양은 세장형으로 나타났다. 특히 해변자갈 II는 해변자갈 I과 달리 모든 시료보다 세장비가 작으므로 장축과 중축의 차이가 크고, 긴 입자의 형상특성을 보여주고 있다. 체가름 시험 및 실측을 통해 결정된 골재의 세장비 및 편평비와 디지털 이미지 처리 기법을 이용해 결정된 골재의 세장비 편평비는 거의 차이가 없는 것으로 나타났다. 이는 실측시 발생할 수 있는 오차를 최소화할 수 있는 방법으로 골재의 입도곡선 작성등에 유용하게 이용할 수 있을 것으로 기대한다.