• Title/Summary/Keyword: verifications

Search Result 269, Processing Time 0.022 seconds

An implementation of automated ECG interpretation algorithm and system(I) - Introduction of YECGA (심전도 자동 진단 알고리즘 및 장치 구현(I) - YECGA 개요)

  • Kweon, H.J.;Jeong, K.S.;Chung, S.J.;Choi, S.J.;Lee, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.175-178
    • /
    • 1996
  • The purpose of this thesis is the propose of various signal processing algorithm for the ECG(electrocardiogram) and the design of realtime automated ECG analyzer feasible with these algorithms. The algorithms are composed of (1)filtering procedure fer the estimation and removal of baseline drift, 60Hz power line interference, and muscle artifacts (2)detection procedure of QRS complex and P wave (3)typification procedure for the pattern classification according to the morphologies (4) selection of representative beat, significant point and wave boundary decision procedure and (5) parameter extraction and diagnosis procedure. All verifications are carried out between the algorithms proposed in this paper and other algorithms already proposed by many researchers, for the objective comparison in each procedure. The efficiency of proposed algorithms are demonstrated with the aid of internationally validated CSE database and the performances of filtering procedure are compared on artificial noise signal as well as actual ECG signals with appropriate noise components. for the comparison on the performance of designed automated ECG analyzer, the diagnosis results were compared with ECG analyzer manufactered by Fukuda denshi in Japan.

  • PDF

An Analysis of the Limit Cycle Oscillation in Digital PID Controlled DC-DC Converters

  • Chang, Changyuan;Hong, Chao;Zhao, Xin;Wu, Cheng'en
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.686-694
    • /
    • 2017
  • Due to the wide use of electronic products, digitally controlled DC-DC converters are attracting more and more attention in recent years. However, digital control strategies may introduce undesirable Limit Cycle Oscillation (LCO) due to quantization effects in the Analog-to-Digital Converter (ADC) and Digital Pulse Width Modulator (DPWM). This results in decreases in the quality of the output voltage and the efficiency of the system. Meanwhile, even if the resolution of the DPWM is finer than that of the ADC, LCO may still exist due to improper parameters of the digital compensator. In order to discover how LCO is generated, the state space averaging model is applied to derive equilibrium equations of a digital PID controlled DC-DC converter in this paper. Furthermore, the influences of the parameters of the digital PID compensator, and the resolutions of the ADC and DPWM on LCO are studied in detail. The amplitude together with the period of LCO as well as the corresponding PID parameters are obtained. Finally, MATLAB/Simulink simulations and FPGA verifications are carried out and no-LCO conditions are obtained.

An Efficient Certificate path Discovery Algorithm Making High a Certificate Path Validity. (인증 경로의 유효성을 높이는 효율적인 인증 경로 설정 알고리즘)

  • Choi Yeon hee;Jun Moon seog
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12C
    • /
    • pp.1722-1728
    • /
    • 2004
  • To discover a certificate path is a very important topic in the PKI with a lot of candidate paths. The certificate path discovery processing is executed via many verifications and as the number of verification times increases, the validity of the discovered path becomes high. The selection of the path with high validity provides high-speed certificate validation by reducing the number of repetition times of path discovery and validation processing. Otherwise, there is a problem that the speed and computation overheads are increased. In this paper, we propose an efficient certificate path discovery algorithm can make high the certificate validity with low overhead.

A Study on the Extraction of Groundwater Potential Area Utilizing the Remotely Sensed Data

  • Chi, Kwang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.10 no.2
    • /
    • pp.109-120
    • /
    • 1994
  • The study is aimed at the extraction of the groundwater potential areas utilizing the remotely sensed data from satellites. The results of the study are summarized as follows. Analyses of the existing operational wells for groundwater supply indicate that 81% of them are related with lineaments and 51% of them are located at the intersections of lineameters. Thus the features of lineaments are considered to be one of the most important parameters to extract a high potertial area of groundwater. Taking into acount features of lineament, high potential points were extracted from Landsat TM data based on the theory developed in this research, then verifications were made through actual drilling. The result of verification indicates that 9 points produces more 200 cubic meter/day which is the amount required from economical point of view for an operational use. Since the actual boring was not made on the recommended points for 4 points due to the difficulty of access to the exact points and of the approval for boring, they did not yield enough output. The result might have been improved if the exact points were bored and if the boring bad been made deeper, since the maximum depth of boring was limited to 62 meters.

Damping and frequency of twin-cables with a cross-link and a viscous damper

  • Zhou, H.J.;Yang, X.;Peng, Y.R.;Zhou, R.;Sun, L.M.;Xing, F.
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.669-682
    • /
    • 2019
  • Vibration mitigation of cables or hangers is one of the crucial problems for cable supported bridges. Previous research focused on the behaviors of cable with dampers or crossties, which could help engineering community apply these mitigation devices more efficiently. However, less studies are available for hybrid applied cross-ties and dampers, especially lack of both analytical and experimental verifications. This paper studied damping and frequency of two parallel identical cables with a connection cross-tie and an attached damper. The characteristic equation of system was derived based on transfer matrix method. The complex characteristic equation was numerically solved to find the solutions. Effects of non-dimensional spring stiffness and location on the maximum cable damping, the corresponding optimum damper constant and the corresponding frequency of lower vibration mode were further addressed. System with twin small-scale cables with a cross-link and a viscous damper were tested. The damping and frequency from the test were very close to the analytical ones. The two branches of solutions: in-phase modes and the out-of-phase modes, were identified; and the two branches of solutions were different for damping and frequency behaviors.

Stress Analysis of Composite Double Lead Spiral in 20mm Universal Ammunition Loading System (20mm 범용탄약적재장비의 복합재 이중리드나선구조 설계)

  • Je, Hyun-Min;Kim, Wie-Dae
    • Composites Research
    • /
    • v.31 no.6
    • /
    • pp.340-346
    • /
    • 2018
  • This paper addresses the stress analysis and design of composite double lead spiral which is boarded in 20mm universal ammunition drum by finite element method. The spiral system is very important to transfer the ammunition in stable and reliable manners for aircraft. Some verifications are done to check the possibility of composite application in spiral system. The design variables, stacking sequence and fiber orientation angles, are investigated for reliable design for practical design. The Tsai-Wu failure theory is applied to see the safety of the spiral structure. The design result is suggested to manufacture the double lead spiral part.

An experimental study on pool sloshing behavior with solid particles

  • Cheng, Songbai;Li, Shuo;Li, Kejia;Zhang, Ting
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.73-83
    • /
    • 2019
  • It is important to clarify the mechanisms of molten-fuel-pool sloshing behavior that might be encountered during a core disruptive accident of sodium-cooled fast reactors. In this study, motivated by acquiring some evidence for understanding the characteristics of this behavior at more realistic conditions, a number of experiments are newly performed by injecting nitrogen gas into a water pool with the accumulation of solid particles. To achieve comprehensive understanding, various parameters including particle bed height, particle size, density, shape, gas pressure along with the gas-injection duration, were employed. It is found that due to the different interaction mechanisms between solid particles and the gas bubble injected, three kinds of regimes, termed respectively as the bubble-impulsion dominant regime, the transitional regime and the bed-inertia dominant regime, could be identified. The performed analyses also suggest that under present conditions, all our experimental parameters employed can have noticeable impact on the regime transition and resultant sloshing intensity (e.g. maximum elevation of water level at pool peripheries). Knowledge and fundamental data from this work will be used for the future verifications of fast reactor severe accident codes in China.

A Study on the Controller Design of the Three-Level Boost Converter for Photovoltaic Power Conditioning System (태양광 발전 시스템용 3-레벨 부스트 컨버터 제어기 설계에 관한 연구)

  • Lee, Kyu-Min;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.227-236
    • /
    • 2021
  • This research proposes a modeling and controller design of a three-level boost (TLB) converter for the implementation of maximum power point tracking (MPPT) in the photovoltaic power conditioning system (PCS). Contrary to the output voltage control of the conventional controller, the Photovoltaic PCS requires an input voltage controller for MPPT operation. A TLB converter has the advantage of decreasing the inductor size and increasing efficiency compared with the existing booster converter. However, an optimal controller is difficult to design due to the complexity of the TLB operations, which have two operational modes on the duty ratio boundary of 0.5. Therefore, the unified linear model equations of the TLB converters, which can be applicable to both operational modes, are derived using linearized solar cell expressions. Furthermore, the transfer functions are obtained for the controller design. The MPPT voltage controller is designed using MATLAB SISOTOOL. In addition, a controller for capacitor voltage unbalancing is described and designed. The simulations and experimental verifications are conducted to verify the effectiveness of the small-signal analysis and control system design.

A Security Analysis of PMAC and TMAC variant (PMAC과 TMAC 변이 알고리즘에 대한 안전성 고찰)

  • 이창훈;김종성;이상진
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.14 no.4
    • /
    • pp.91-96
    • /
    • 2004
  • In this paper, we introduce two forgery attacks on the PMAC. If it has no truncation then the attack requires about $2^{n}$ 2+1/ chosen texts, otherwise, the attack requires about $2^{n}$ 2+1/ chosen texts and $2^{n-}$$\tau$ MAC verifications where $\tau$ is the size of the MAC. We also give a forgery attack on the TMAC variant which requires about $2^{n}$ 2+1/ texts.

An Study on the Improved Modeling and Double Loop Controller Design for Three-Level Boost Converter (Three-Level Boost Converter의 개선된 모델링 및 더블 루프 제어기 설계에 관한 연구)

  • Lee, Kyu-Min;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.442-450
    • /
    • 2020
  • A small-signal modeling approach for a three-level boost (TLB) converter and a design methodology for a double-loop controller are proposed in this study. Conventional modeling of TLB converters involves three state variables. Moreover, TLB converters have two operation modes depending on the duty ratio. Consequently, complex mathematical calculations are required for controller design. This study proposes a simple system modeling method that uses two state variables, unlike previous methods that require three state variables. Analysis shows that the transfer functions of the two operation modes can be expressed as identical equations. This condition means that the linear feedback controller can be applied to all operational ranges, that is, for full duty ratios. The design method for a double-loop controller using a PI controller is presented in step-by-step sequences. Simulation and experimental verifications are conducted to verify the effectiveness of the small-signal analysis and control system design.