• 제목/요약/키워드: verification of effectiveness

검색결과 593건 처리시간 0.025초

열선 절단 방식을 적용한 비폭발식 무충격 구속분리장치 EM의 기능검증 (Functional Verification of Engineering Model of Non-explosive Shockless Holding and Release Mechanism Using Heating Wire Cutting Method)

  • 오현웅;전수현
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.401-406
    • /
    • 2013
  • Non-explosive shockless holding and release mechanism for a nano class small satellite application has been proposed and investigated. The great advantages of the mechanism are a much lower shock level and larger constraint force than the conventional mechanism using pyro and the heating wire cutting mechanism which has been generally applied to the cube satellite program. To investigate the effectiveness of the mechanism design, EM mechanism was developed and tested to verify the basic function of the mechanism. The test results indicate that the proposed mechanism is well functioning as the mechanism design intends.

멀티형 냉방시스템의 압축기 제어 (Compressor Control of a Multi-type AIr Conditioning System)

  • 한도영;권형진
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.780-786
    • /
    • 2001
  • For the compressor speed control of a multi-type air conditioning system, a fuzzy control algorithm was developed. The sum of zone temperature errors and its derivative were used as input variables, and the compressor speed was selected as the output variable. To test the effectiveness of the control algorithm, one outdoor environmental chamber and four indoor environmental chambers were used. In the chambers the zone temperature step change test and the indoor unit change over test were performed. Test results showed that, for the control of compressor speed, the fuzzy control algorithm was more effective than the conventional proportional control algorithm for the energy conservation.

  • PDF

사이클 기반 논리시뮬레이션 가속화 기법 연구 (Acceleration Techniques for Cycle-Based Login Simulation)

  • 박영호;박은세
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권1호
    • /
    • pp.45-50
    • /
    • 2001
  • With increasing complexity of digital logic circuits, fast and accurate verification of functional behaviour becomes most critical bottleneck in meeting time-to-market requirement. This paper presents several techniques for accelerating a cycle-based logic simulation. The acceleration techniques include parallel pattern logic evaluation, circuit size reduction, and the partition of feedback loops in sequential circuits. Among all, the circuit size reduction plays a critical role in maximizing logic simulation speedup by reducing 50% of entire circuit nodes on the average. These techniques are incorporated into a levelized table-driven logic simulation system rather than a compiled-code simulation algorithm. Finally, experimental results are given to demonstrate the effectiveness of the proposed acceleration techniques. Experimental results show more than 27 times performance improvement over single pattern levelized logic simulation.

  • PDF

강인 포화 제어기의 안정성에 관한 실험적 검증 (Experimental Verification on Stability of Robust Saturation Controller)

  • 임채욱;문석준;박영진;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.223-226
    • /
    • 2005
  • In previous research, we proposed robust saturation controller which involves both actuator's saturation and structured real parameter uncertainties. This controller can analytically prescribed the upper and lower bounds of parameter uncertainties, and guarantee the closed-loop robust stability of the system in the presence of actuator's saturation. And the availability and the effectiveness of the proposed robust saturation controller were verified through numerical simulations. In this paper, we verify the robust stability of this controller through experimental tests. Especially, we show unstable cases of other controllers in comparison with this controller. Experimental tests are carried out in the laboratory using a two-story test structure with a hydraulic-type active mass damper.

  • PDF

철도조직 구성원의 상사리더십 지각이 조직유효성에 미치는 영향 : 다원적 리더십의 효과검증 (A Study on the Effects of Leadership Perception on the Organizational Effectiveness in Railway Organizations : Verification of Multiple Leadership Effects)

  • 추준섭;신택현
    • 한국철도학회논문집
    • /
    • 제10권6호
    • /
    • pp.792-799
    • /
    • 2007
  • 본 논문은 인식틀 개념에 입각하여 상사의 리더십 인식틀 유형에 대한 부하의 지각이 직무만족, 상사에 대한 신뢰와 존경, 상사의 승진속도 등 일련의 종속변수에 어떤 영향을 주는지 확인해보려는데 목적이 있다. 이를 위해 선행연구를 토대로 관련 가설을 설정하고 철도조직의 구성원을 대상으로 한 설문을 토대로 가설검증을 실시하였다.

ON GLOBAL EXPONENTIAL STABILITY FOR CELLULAR NEURAL NETWORKS WITH TIME-VARYING DELAYS

  • Kwon, O.M.;Park, Ju-H.;Lee, S.M.
    • Journal of applied mathematics & informatics
    • /
    • 제26권5_6호
    • /
    • pp.961-972
    • /
    • 2008
  • In this paper, we consider the global exponential stability of cellular neural networks with time-varying delays. Based on the Lyapunov function method and convex optimization approach, a novel delay-dependent criterion of the system is derived in terms of LMI (linear matrix inequality). In order to solve effectively the LMI convex optimization problem, the interior point algorithm is utilized in this work. Two numerical examples are given to show the effectiveness of our results.

  • PDF

송전계통 선로보호 계전기 동작 진단 시스템 (A Development of Protective Relay Operating-Diagnosis System for Power System)

  • 김국진;이승재;최면송;강상희;김호표;이운희;최홍석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.107-109
    • /
    • 1999
  • In the point of view protective relay, the selectivity and sensitivity is very important in its performance. The correct setting of the relay parameter is required. The verification of accurate setting for the protective relay is very difficult before a actual fault occurs. In this paper, we proposed the diagnosis expert system as a method to verify the correctness of the relay setting. The developed system proved effectiveness through the tests on the real systems.

  • PDF

유한요소법에서의 파진행 문제를 위한 흡수경계 성능에 관한 연구 (A Study on the Performance of Absorbing Boundaries for Wave propagation Using Finite Element Method)

  • 김희석;이종세
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.413-420
    • /
    • 2003
  • In this paper an analytical study is carried out to examine the effectiveness of absorbing boundaries using dashpot. Validity of the absorbing boundary conditions suggested by Lysmer-Kuhlemeyer and White et al. is investigated by adopting the solution of Miller and Pursey. The Miller and Pursey's problem is then numerically simulated using the finite element method. The absorption ratios are calculated by comparing the displacements at the absorbing boundary to those at the free field without the absorbing boundary. The numerical verification is carried out through comparison of displacement at the boundary.

  • PDF

이산사건 모델링 및 시뮬레이션 기반 LYNX-ESM 체계 시뮬레이션에 관한 연구 (A Research on the LYNX-ESM System Operating and Performance Prediction Simulation Based on DEVS)

  • 신동조;윤기천
    • 한국군사과학기술학회지
    • /
    • 제9권4호
    • /
    • pp.61-70
    • /
    • 2006
  • This paper is to describe LYNX-ESM Simulation System to simulate for EW operating environment analysis and system performance verification of LYNX-ESM system using Discrete Event Simulation(DEVS) Methodology. This system consists of 3 PC with TCP/IP network. Each PC is loaded with Modeling & Simulation program based DEVS. Each connected program conducts EW simulation. As a result, we analyze the operating environment of the maritime EW threat, simulate the EW threat discrimination and geolocation capability, and estimate the LYNX-ESM system effectiveness before real LYNX-ESM system development.

A Practical Power System Stabilizer Tuning Method and its Verification in Field Test

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Baek, Seung-Mook;Choy, Young-Do;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.400-406
    • /
    • 2010
  • This paper deals with parameter tuning of the Power System Stabilizer (PSS) for 612 MVA thermal power plants in the KEPCO system and its validation in a field test. In this paper, the selection of parameters, such as lead-lag time constants for phase compensation and system gain, is optimized using linear and eigenvalue analyses. This is then verified through the time-domain transient stability analysis. In the next step, the performance of PSS is finally verified by the generator's on-line field test. After the field test, measured and simulated data are also compared to prove the effectiveness of the models used in the simulations.