• Title/Summary/Keyword: ventricular performance

Search Result 118, Processing Time 0.025 seconds

Left Ventricular Function Changes Under Normothermic Krebs Perfusate in Newborn Piglet (신생 돼지심장에서 상온의 Krebs 용액 관류에 따른 좌심실 기능의 변화)

  • O, Bong-Seok;Na, Guk-Ju;Lee, Dong-Jun
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1067-1073
    • /
    • 1990
  • To clarify the changes of left ventricular function under normothermia, the time interval between the onset of ischemia and the beginning of contracture of left ventricle[TIC] were recorded in newborn piglet. Myocardial performance was assessed using intraventricular balloon to determine compliance and systolic function after 5 to 10 minutes interval per-fusing normothermic substrate free Krebs solution as a perfusate. The time to onset TIC was 29.5\ulcorner1.7 minutes and peak ischemic contracture was 46.7\ulcorner4.0 minutes[p<0.01]. In myocardial performance, systolic function of left ventricle[defined as cardiac contractility] was kept until 25 minutes of perfusion, but was decreased abruptly after 30 minutes of perfusion[p<0.0018] and diastolic function of left ventricle[defined as diastolic compliance] was kept until 15 minutes of perfusion, but was decreased after 20 minutes of perfusion [p=0.00\ulcorner9]. This study demonstrated maximal time of the tolerance to normothermic global ischemia and functional changes of left ventricle using Krebs perfusate under the same condition.

  • PDF

Spontaneous Cerebellar Hemorrhage with the Fourth Ventricular Hemorrhage : Risk Factors Associated with Ventriculoperitoneal Shunt

  • Shin, Donguk;Woo, Hyun-Jin;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.320-324
    • /
    • 2012
  • Objective : The purposes of this study are to investigate the factors that may be related to ventriculoperitoneal (VP) shunt in patients with cerebellar hematoma and the effect of severe fourth ventricular hemorrhage, causing obstructive hydrocephalus on subsequent VP shunt performance. Methods : This study included 31 patients with spontaneous cerebellar hematoma and concomitant fourth ventricular hemorrhage, who did not undergo a surgical evacuation of hematoma. We divided this population into two groups; the VP shunt group, and the non-VP shunt group. The demographic data, radiologic findings, and clinical factors were compared in each group. The location of the hematoma (whether occupying the cerebellar hemisphere or the vermis) and the degree of the fourth ventricular obstruction were graded respectively. The intraventricular hemorrhage (IVH) score was used to assess the IVH severity. Results : Ten out of 31 patients underwent VP shunt operations. The midline location of cerebellar hematoma, the grade of fourth ventricle obstruction, and IVH severity were significantly correlated with that of VP shunt operation (p=0.015, p=0.013, p=0.028). The significant variables into a logistic regression multivariate model resulted in statistical significance for the location of cerebellar hemorrhage [p=0.05; odds ratio (OR), 8.18; 95% confidence interval (CI), 1.00 to 67.0], the grade of fourth ventricle obstruction (p=0.044; OR, 19.26; 95% CI, 1.07 to 346.6). Conclusion : The location of the cerebellar hematoma on CT scans and the degree of fourth ventricle obstruction by IVH were useful signs for the selection of VP shunt operation in patients with spontaneous cerebellar hematoma and concomitant acute hydrocephalus.

Patient Adaptive Pattern Matching Method for Premature Ventricular Contraction(PVC) Classification (조기심실수축(PVC) 분류를 위한 환자 적응형 패턴 매칭 기법)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.2021-2030
    • /
    • 2012
  • Premature ventricular contraction(PVC) is the most common disease among arrhythmia and it may cause serious situations such as ventricular fibrillation and ventricular tachycardia. Particularly, in the healthcare system that must continuously monitor patient's situation, it is necessary to process ECG (Electrocardiography) signal in realtime. In other words, the design of algorithm that exactly detects R wave using minimal computation and classifies PVC by analyzing the persons's physical condition and/or environment is needed. Thus, the patient adaptive pattern matching algorithm for the classification of PVC is presented in this paper. For this purpose, we detected R wave through the preprocessing method, adaptive threshold and window. Also, we applied pattern matching method to classify each patient's normal cardiac behavior through the Hash function. The performance of R wave detection and abnormal beat classification is evaluated by using MIT-BIH arrhythmia database. The achieved scores indicate the average of 99.33% in R wave detection and the rate of 0.32% in abnormal beat classification error.

Support Vector Machine Based Arrhythmia Classification Using Reduced Features

  • Song, Mi-Hye;Lee, Jeon;Cho, Sung-Pil;Lee, Kyoung-Joung;Yoo, Sun-Kook
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.4
    • /
    • pp.571-579
    • /
    • 2005
  • In this paper, we proposed an algorithm for arrhythmia classification, which is associated with the reduction of feature dimensions by linear discriminant analysis (LDA) and a support vector machine (SVM) based classifier. Seventeen original input features were extracted from preprocessed signals by wavelet transform, and attempts were then made to reduce these to 4 features, the linear combination of original features, by LDA. The performance of the SVM classifier with reduced features by LDA showed higher than with that by principal component analysis (PCA) and even with original features. For a cross-validation procedure, this SVM classifier was compared with Multilayer Perceptrons (MLP) and Fuzzy Inference System (FIS) classifiers. When all classifiers used the same reduced features, the overall performance of the SVM classifier was comprehensively superior to all others. Especially, the accuracy of discrimination of normal sinus rhythm (NSR), arterial premature contraction (APC), supraventricular tachycardia (SVT), premature ventricular contraction (PVC), ventricular tachycardia (VT) and ventricular fibrillation (VF) were $99.307\%,\;99.274\%,\;99.854\%,\;98.344\%,\;99.441\%\;and\;99.883\%$, respectively. And, even with smaller learning data, the SVM classifier offered better performance than the MLP classifier.

Impact of Hemodialysis on Left Ventricular Performance: A Doppler Echocardiographic Study (혈액투석 유지요법 환자에서 투석 전후의 좌심실 Doppler 심초음파를 이용한 기능지표의 변화)

  • Kang, Dong-Oh;Lee, Du-Ha;Kim, Hyun-Seo;Kim, Hyun-Su;Kim, Sung-Rok;Park, Jong-Seon
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.309-317
    • /
    • 1999
  • Background: Left ventricular diastolic filling is an important determinant for maintenance of cardiac output during hemodialysis. Few investigators have studied the influence of hemodialysis on diastolic function. To evaluate the change of left ventricular systolic and diastolic function. we performed M-mode and Doppler echocardiographic studies before and after hemodialysis. Methods: The study population consisted of 30 patients(15 patients were male, mean age $45{\pm}10$ years) with CRF on maintenance hemodialysis. They have normal left ventricular systolic function(Fractional shortening>30%) and no evidence of valvular heart disease or regional wall motion abnormalities. The ejection fraction (EF) was measured using M-mode echocardiography and Doppler indices such as peak E velocity, peak A velocity, isovolumetric relaxation time(IVRT), deceleration time(DT). and left ventricular ejection time(LVET) obtained from Doppler echocardiography. The index of myocardial performance (IMP) was calculated from each of the Doppler velocity indices. Results: The weight reduction after hemodialysis was $2.1{\pm}1.0kg$(p<0.0001), After hemodialysis, there was some decrease in blood pressure(p<0.05), but no significant change in heart rate, EF and fractional shortening, mean VCF, peak A velocity, and DT. And significant reduction in peak E velocity, E/A ratio(p<0.0001. p<0.001), and significant increase in IVRT and IMP(p<0.05, p<0.0001) were noted. Conclusion: In conclusion, preload reduction is the main mechanism that accounts for changes in Doppler diastolic indices after hemodialysis. And an increased IMP suggests that diastolic function may be aggravated after hemodialysis, and that implies impaired left ventricular filling and disturbed left ventricular compliance.

  • PDF

An Animal Study on Electrohydraulic Type Ventricular Assist Device (전기 유압식 심실보조장치의 동물실험 연구)

  • 백완기;심상석
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.689-699
    • /
    • 1996
  • An animal experiment was designed for the evaluation of in vivo performance of the newly developed electrohydraulic type ventricular assist device and its influence on the left ventricular function during pal- satile left ventricular assist. Eight adult sheep were incorporated into the study and data were collected from seven sheep. Total as- sist time ranged from 69 minutes to 7 days. The performance of the device was satisfactory both in asyn- chr nous and synchronous mode within the range of given native heart rate. More than 4 liters of device output could be reached within the range of normal left atral pressure without development of negative pressure in the left atrium. Moderate to severe degree of hemolysis was noted as evidenced by significant increase of plasma free hemoglobin level after 3 days of left ventricular support along with the presence of the small amount of thrombi around the floating disc type polymer valve apparatus reflecting that further study and refinement of the device need to be done in regard of biocompatibility and thromboresistance. The hemodynamics showed increase in heart rate (p < 0.05), cardiac output and left ventricular minute work (p < 0.05) after placement of the device at the flow rate of 2.0∼2.5 Llmin. The left atrial pressure, left ventricular pressure and LV dpldt were decreased after the device placement(p < 0.05). The endocardial viability ratio and oxygen contents of the mixed ven us blood and coronary venous blood were all increased (p < 0.05) after the device placement suggesting effective unloading of the left ventricle was accomplished. The myocardial perfusion was thought improved in synchronous counterpulsation as suggested by sig- nificant increase in endocardial viability ratio and coronary venous blood oxygen content in synchronous assist mode comparing with asynchronous mode.

  • PDF

Non-Contrast Cine Cardiac Magnetic Resonance Derived-Radiomics for the Prediction of Left Ventricular Adverse Remodeling in Patients With ST-Segment Elevation Myocardial Infarction

  • Xin A;Mingliang Liu;Tong Chen;Feng Chen;Geng Qian;Ying Zhang;Yundai Chen
    • Korean Journal of Radiology
    • /
    • v.24 no.9
    • /
    • pp.827-837
    • /
    • 2023
  • Objective: To investigate the predictive value of radiomics features based on cardiac magnetic resonance (CMR) cine images for left ventricular adverse remodeling (LVAR) after acute ST-segment elevation myocardial infarction (STEMI). Materials and Methods: We conducted a retrospective, single-center, cohort study involving 244 patients (random-split into 170 and 74 for training and testing, respectively) having an acute STEMI (88.5% males, 57.0 ± 10.3 years of age) who underwent CMR examination at one week and six months after percutaneous coronary intervention. LVAR was defined as a 20% increase in left ventricular end-diastolic volume 6 months after acute STEMI. Radiomics features were extracted from the oneweek CMR cine images using the least absolute shrinkage and selection operator regression (LASSO) analysis. The predictive performance of the selected features was evaluated using receiver operating characteristic curve analysis and the area under the curve (AUC). Results: Nine radiomics features with non-zero coefficients were included in the LASSO regression of the radiomics score (RAD score). Infarct size (odds ratio [OR]: 1.04 (1.00-1.07); P = 0.031) and RAD score (OR: 3.43 (2.34-5.28); P < 0.001) were independent predictors of LVAR. The RAD score predicted LVAR, with an AUC (95% confidence interval [CI]) of 0.82 (0.75-0.89) in the training set and 0.75 (0.62-0.89) in the testing set. Combining the RAD score with infarct size yielded favorable performance in predicting LVAR, with an AUC of 0.84 (0.72-0.95). Moreover, the addition of the RAD score to the left ventricular ejection fraction (LVEF) significantly increased the AUC from 0.68 (0.52-0.84) to 0.82 (0.70-0.93) (P = 0.018), which was also comparable to the prediction provided by the combined microvascular obstruction, infarct size, and LVEF with an AUC of 0.79 (0.65-0.94) (P = 0.727). Conclusion: Radiomics analysis using non-contrast cine CMR can predict LVAR after STEMI independently and incrementally to LVEF and may provide an alternative to traditional CMR parameters.

Development of Nursing Practice Guideline for External Ventricular Drainage by Adaptation Process (수용개작을 통한 뇌실외배액 간호 실무지침 개발)

  • Jung, Won Kyung;Yi, Young Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.22 no.3
    • /
    • pp.294-304
    • /
    • 2016
  • Purpose: This study was done to develop an evidence-based external ventricular drainage (EVD) nursing practice guideline in order to provide standardized nursing and prevent EVD related complications. Methods: We used the standardized methodology for nursing practice guideline adaptation developed by Korean Hospital Nurses Association for the guideline adaptation process in this study. Results: The newly developed EVD nursing practice guideline was adapted to the American Association of Neuroscience Nurses (AANN)'s clinical practice guideline which is 'Care of the patient undergoing intra-cranial pressure monitoring/external ventricular drainage of lumbar drainage.' There were 61 recommendations documented in the preliminary guideline all evaluated by 9 experts based on acceptability and applicability. The final practice guideline was composed of 3 domains with 57 recommendations. The three domains of nursing were the insertion, maintenance, and removal of the EVD. The number of recommendations in each domain was 8 in EVD insertions, 39 in EVD maintenance, and 10 in EVD removals. Of the 57 recommendations 3.5% were level 1, 31.5% were level 2, and 65% were level 3. Conclusion: The standardized practice guideline can improve nurses' performance and accuracy. It can also be used as the foundation for effective communication between all medical staff.

Control Simulation of Left Ventricular Assist Device using Artificial Neural Network (인공신경망을 이용한 좌심실보조장치의 제어 시뮬레이션)

  • Kim, Sang-Hyeon;Jeong, Seong-Taek;Kim, Hun-Mo
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.39-46
    • /
    • 1998
  • In this paper, we present a neural network identification and a control of highly complicated nonlinear left ventricular assist device(LVAD) system with a pneumatically driven mock circulation system. Generally, the LVAD system needs to compensate for nonlinearities. It is necessary to apply high performance control techniques. Fortunately, the neural network can be applied to control of a nonlinear dynamic system by learning capability. In this study, we identify the LVAD system with neural network identification(NNI). Once the NNI has learned the dynamic model of the LVAD system, the other network, called neural network controller(NNC), is designed for a control of the LVAD system. The ability and effectiveness of identifying and controlling the LVAD system using the proposed algorithm will be demonstrated by computer simulation.

  • PDF

Predicting Successful Defibrillation in Ventricular Fibrillation using Wave Analysis and Neuro-fuzzy

  • Shin Jae-Woo;Lee Hyun-Sook;Hwang Sung-Oh;Yoon Young-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.2
    • /
    • pp.47-52
    • /
    • 2006
  • The purpose of this study was to predict successful defibrillation in ventricular fibrillation using parameters extracted by wave analysis method and neuro-fuzzy. Total 15 dogs were tested for predicting successful defibrillation. Feature parameters were extracted for return of spontaneous circulation (ROSC) and non-ROSC by wave analysis method, and these parameters are an irregularity factor, spectral moments, mean power of level-crossing spectrum, and mean of alpha-significant value. Additionally, two parameters by analyzing method of frequency were extracted into a mean of power spectrum and a mean frequency. Then extracted parameters were analyzed in which parameters result to have high performance of discriminating ROSC and non-ROSC by a statistical method of t-test. The average of sensitivity and specificity were 62.5% and 75.0%, respectively. The average of positive predictive factor and negative predictive factor were 61.2% and 75.8%, respectively.