• Title/Summary/Keyword: ventilation threshold

Search Result 34, Processing Time 0.027 seconds

Evaluation of Air Contaminants Concentrations and Ventilation Systems in Governmental Agency and University Laboratories (국내 정부출연연구기관 및 대학교 실험실 공기 오염물질 농도 및 환기시스템 평가)

  • Ha, Ju-Hyun;Shin, Yong-Chul;Lee, Hyun-Seok;Paik, Samuel Y.;Yi, Gwang-Yong;Lee, Byeong-Ku
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • This study was conducted to compare the concentration of various air contaminants in nine different laboratories during routine activities. Volatile organic compounds (VOC) were sampled and analyzed using NIOSH Method 1500 and asbestos fibers were sampled and analyzed using NIOSH Method 9002 and 7400. Detectable levels of acetone, toluene and ethanol were found in all the laboratories and xylene and n-hexane were detected in eight of the nine laboratories. All the VOC concentrations were well below the Korean Ministry of Labor's Exposure Limit and American Conference of Governmental Industrial Hygienists' (ACGIH) Threshold Limit Values (TLVs). Total VOC concentrations at the university laboratories were significantly higher than those at governmental agency laboratories. Airborne fiber concentrations were below 0.01 fibers/cc, while the concentration of chrysotile was 2% in insulation materials sprayed on the ceiling of one laboratory. While all the governmental agency laboratories (n=4) had fume hoods, two out of the five university laboratories did not have fume hoods. The capture velocity of half of the fume hoods were below the maintenance standard(0.4 m/sec). In conclusion, the study suggests that the current controls in place at both university and government agency laboratories are not sufficient in limiting exposure to harmful chemicals to non-detectable levels, though they appear to be adequate in protecting workers to levels below applicable occupational exposure limits. The study also suggests that researchers working in university laboratories may be exposed to greater levels of contaminant than those working in government agency laboratories.

A Follow up Study on the Mercury Concentration in Air and in Urine of Workers after Implementing Controls of Work Environment in Mercury Vapor Exposed Industry (모 수은폭로 사업장의 작업환경개선에 의한 근로자의 요중 수은 및 공기중 수은 농도의 추적조사 연구)

  • Bang, Shin Ho;Kim, Kwang Jong;Park, Jong Tae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.198-207
    • /
    • 1994
  • In order to evaluate the effectiveness of environmental intervention of work place, metal mercury concentration in air and in urine of the total 43 workers for 3years from December 1991 to October 1993 in a fluorescent lamp manufacturing industry exposed to mercury, was measured before and after implementation of controls such as establishing exhaust ventilation at the department of exhaustion, coating the floor of work place with epostane, cleaning of the floor, improved housekeeping, and etc. The results were as follows. 1. Before the intervention(December 1991) 39.0% exceeded metal mercury Threshold Limit Value(TLV, $0.05mg/m^3$). After the intervention(October 1993) 10.0% exceeded TLV and geometric mean of mercury in air was $0.1mg/m^3$, and showed effectiveness rate of intervention to be 74.4% 2. After the intervention, geometric means of mercury concentrations in air were 0.013, $0.019mg/m^3$ and showed effectiveness rate of intervention to be 76.6%, 65.5% in A factory(right tube lamp)and at exhaustion department, respectively, A follow up survey fround statistically significant reductions in mercury concetration in air three years later. 3. Mercury concentration in urine of 11 workers(29.7%) exceeded warning level of $100{\mu}l/l$ before the intervention. After the intervention, of 3workers(8.8%) exceeded warning level and geometric mean of mercury concentration($26.5{\mu}l/l$) in urine was 2.4 times than that of before the intervention. Geometric means of mercury concentrations in urine of workers at exhaustion department, at sealing and aging department were 44.0, $77.7{\mu}l/l$, respectively and they decreased 2.3, 3.2 times than that of before the intervention.

  • PDF

Effect of Seizure on Prognosis in Acute Endosulfan Intoxication (급성 endosulfan 중독환자에서 경련이 예후에 미치는 영향)

  • Han, Byung-Gon;Lee, Jun-Ho;Lee, Kyung-Woo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.7 no.2
    • /
    • pp.77-82
    • /
    • 2009
  • Purpose: In highly doses, endosulfan lowers the seizure threshold and elicits central nervous system stimulation, which can result in seizures, respiratory failure, and death. Management of seizure control is essential for survival and prognosis of intoxicated patients. This study assessed whether seizure time was an independent predictor mortality in patients with endosulfan poisoning. Methods: This retrospective study enrolled patients with endosulfan poisoning presenting to Masan Samsung Hospital and Gyeongsang National University Hospital from January 2003 to December 2008. The data were collected from clinical records and laboratory files. Using a multivariate logistic analysis, data on the total population was retrospectively analyzed for association with mortality. Results: Of the 24 patients with endosulfan poisoning, nineteen (79.1%) experienced seizure. The patients in the seizure group showed significantly lower Glasgow coma scale score, base excess, bicarbonate, and significant existence of mechanical ventilation, as compared to the non seizure group (n=5). Seizure, Glasgow coma scale score, systolic blood pressure, bicarbonate level, need for respiratory support, pulse rate, respiratory rate, pH, base excess, and seizure time were associated with mortality. The fatality rate of endosulfan poisoning was 54.1% with higher mortality among patients experiencing. Longer seizure time was associated with higher mortality. Conclusion: Seizure time can be a significant independent predictor of mortality in patients with acute endosulfan poisoning. Physicians should aggressively treat for seizure control in patients with acute endosulfan poisoning.

  • PDF

The Changes of External Ear Resonance after Surgery for Repair of the Postauricular Meato-Mastoid Cutaneous Fistula (외이도-유양동-귀뒤바퀴피부 누공환자에서 수술 전, 후의 외이도 공명의 변화)

  • Kim, Sangjun;Kang, Myung Koo;Jeong, Sung Wook;Lee, Dong Kun
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • v.29 no.2
    • /
    • pp.235-239
    • /
    • 2018
  • Due to the structure with one end closed, the external ear resonance effect in which the high frequency is amplified can be generated, and the sound can be perceived well. The external ear resonance normally has a first peak and a second peak. On average, the first peak has a gain of 18.6 dB at 2620 Hz and the second peak has a gain of 18.2 dB at 4210 Hz. The resonance of the external auditory canal changes with the state of the tympanic membrane, the presence of the ventilation tube, and the structure (length, diameter, shape) of the external auditory canal. A patient with a postauricular meatomastoid cutaneous fistula was admitted to the hospital with a foreign body which is the molding of the hearing aid. After removal of the foreign body, the resonance of the external auditory canal was lost and the subjective sound cognitive ability decreased. In the case of postauricular meatomastoid cutaneous fistula, we confirmed the improvement of sound cognitive ability, the change of pure tone hearing threshold, and the change of the external ear resonance after reconstruction of the ear canal without middle ear reconstruction.

Effects of Sports Drink Including the Extract from Prunus mume on the Changes of Respiratory Variables, Heart Rate, and Blood Lactate Concentration in Submaximal Exercise (매실함유 음료섭취가 장시간 운동시 심박수, 호흡가스 변인 및 혈중 젖산농도 변화에 미치는 영향)

  • 김기진;배지현
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.9 no.2
    • /
    • pp.177-187
    • /
    • 1999
  • This study was designed to investigate the effects of sports drink including the extract from Prunus mume on the changes of oxygen uptake, minute ventilaton, heart rate, and blood lactate concentration during 1 hour treadmill running exercise corresponding to 75%VO$_2$max. Subjects were 16 male athletes(long distance runners and tennis players). The changing patterns of oxygen uptake and minute ventilation showed no significnat difference among all types of sports drink, but the minute vetilation of the placebo group showed a higher value than type I group during submaximal exercise. Although the changing patterns of heart rate and blood lactate concentration showed no significnat difference among all types of sports drink, but type E group showed a lower heart rate compared to Placebo group. And blood lactate concentration of placebo group showed a higher value compared to the value corresponding to lactate threshold during submaimal exercise. but the other types of sports drink showed a lower value of blood lactate concentration. Especially blood lactate threshold of type D and E groups showed a lower value (range from 1.44 to 2.00mM) during submaximal exercise. In these results, the sports drink including the extract from Prunus mume showed no significant effects to the changes of oxygen uptake, minute ventilaton, heart rate, and blood lactate concentration during 1 hour treadmill runnuing exercise corresponding to 75%VO$_2$max. But it could be suggested the positive effects of the intake of sports drink including the extract from Prunus mume on the inhibition of exercise-induced fatigue during submaximal exercise, because of the lower changing Patterns of heart rate, blood lactate concentration, and ventilation efficiency in this results.

  • PDF

A Studs on Exposure to Organic Dust and Ammonia in Poultry Confinement Buildings (일부 육용 양계 농업인의 유기먼지와 암모니아 노출에 관한 연구)

  • Shin, Cheol-Lim;Lee, Kyung-Suk;Kim, Kyung-Ran;Kang, Tae-Sun;Paik, Nam-Won
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.2
    • /
    • pp.303-314
    • /
    • 2004
  • Objectives: This study was carried out to assess exposure levels of organic dusts and ammonia in poultry farms in Korea. Methods: A total of six poultry farms were investigated. The farms were located in Namwon, Chonlabuk-do and in Kae-San, Chungchongbuk-do. This study consisted of a questionnaire and measuring organic dusts and ammonia. The questionnaire included the characteristics of the farms, work patterns and the tasks of the poultry farms. Results and Conclusions: The farmers raised the chickens 45 times a year and the average number of years in the poultry farm were eight years ranging from 2 to 12 years. They worked for seven days per week and the average hours spent caring the chickens are 6.3 hours per day. The duration of staying in the confinement buildings was 3.3 hours per day. The work time in summer was longest. The feed and the water supply systems were automatic and the control of ventilation windows used "winch curtain" was semiautomatic. They used mechanical ventilation system in winter and used dilution ventilation system in the other seasons. The geometric mean concentration of total and respirable dust sampled in the poultry confinement buildings was 4.0 mg/$m^3$and 0.9 mg/$m^3$ respectively. The ratio of respirable to total dusts range from 9 to 49 percent. There was no sample exceeding the criteria 10 mg/$m^3$ for total dust and 3 mg/$m^3$ for respirable dust in farms. The criteria have been recommended by Korean Ministry of Labor and American Conference of Governmental Industrial Hygienist. The personal respirable dusts measured during a circle work averaged geometric mean concentration 1.4 mg/$m^3$ Two personal samples were exceeded the threshold 3 mg/$m^3$. There was a positive relation between an index and the personal samples of respirable dusts($R^2$=0.98). The index is calculated by multipling the total number of chickens in the farm by the age of the chickens and then dividing by the volume of the confinement building. The geometric mean concentration of area and personal ammonia samples was 23.3 ppm and 22.2 ppm, respectively. Some of the ammonia samples, both area and personal samples, exceeded the short term exposure limit value 35 ppm.

  • PDF

The Effect of External PEEP on Work of Breathing in Patients with Auto-PEEP (Auto-PEEP이 존재하는 환자에서 호흡 일에 대한 External PEEP의 효과)

  • Chin, Jae-Yong;Lim, Chae-Man;Koh, Youn-Suck;Park, Pyung-Whan;Choi, Jong-Moo;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.201-209
    • /
    • 1996
  • Background : Auto-PEEP which develops when expiratory lung emptying is not finished until the beginning of next inspiration is frequently found in patients on mechanical ventilation. Its presence imposes increased risk of barotrauma and hypotension, as well as increased work of breathing (WOB) by adding inspiratory threshold load and/or adversely affecting to inspiratory trigger sensitivity. The aim of this study is to evaluate the relationship of auto-PEEP with WOB and to evaluate the effect of PEEP applied by ventilator (external PEEP) on WOB in patients with auto-PEEP. Method : 15 patients, who required mechanical ventilation for management of acute respiratory failure, were studied. First, the differences in WOB and other indices of respiratory mechanics were examined between 7 patients with auto-PEEP and 8 patients without auto-PEEP. Then, we applied the 3 cm $H_2O$ of external PEEP to patients with auto-PEEP and evaluated its effects on lung mechanics as well as WOB. Indices of respiratory mechanics including tidal volume ($V_T$), repiratory rate, minute ventilation ($V_E$), peak inspiratory flow rate (PIFR), peak expiratory flow rate (PEFR), peak inspiratory pressure (PIP), $T_I/T_{TOT}$, auto-PEEP, dynamic compliance of lung (Cdyn), expiratory airway resistance (RAWe), mean airway resistance (RAWm), $p_{0.1}$, work of breathing performed by patient (WOB), and pressure-time product (PTP) were obtained by CP-100 Pulmonary Monitor (Bicore, USA). The values were expressed as mean $\pm$ SEM (standard error of mean). Results : 1) Comparison of WOB and other indices of respiratory mechanics in patients with and without auto-PEEP : There was significant increase in WOB ($l.71{\pm}0.24$ vs $0.50{\pm}0.19\;J/L$, p=0.007), PTP ($317{\pm}70$ vs $98{\pm}36\;cm$ $H_2O{\cdot}sec/min$, p=0.023), RAWe ($35.6{\pm}5.7$ vs $18.2{\pm}2.3\;cm$ H2O/L/sec, p=0.023), RAWm ($28.8{\pm}2.5$ vs $11.9{\pm}2.0cm$ H2O/L/sec, p=0.001) and $P_{0.1}$ ($6.2{\pm}1.0$ vs 2.9+0.6 cm H2O, p=0.021) in patients with auto-PEEP compared to patients without auto-PEEP. The differences of other indices including $V_T$, PEFR, $V_E$ and $T_I/T_{TOT}$ showed no significance. 2) Effect of 3 cm $H_2O$ external PEEP on respiratory mechanics in patients with auto-PEEP : When 3 cm $H_2O$ of external PEEP was applied, there were significant decrease in WOB ($1.71{\pm}0.24$ vs $1.20{\pm}0.21\;J/L$, p=0.021) and PTP ($317{\pm}70$ vs $231{\pm}55\;cm$ $H_2O{\cdot}sec/min$, p=0.038). RAWm showed a tendency to decrease ($28.8{\pm}2.5$ vs $23.9{\pm}2.1\;cm$ $H_2O$, p=0.051). But PIP was increased with application of 3 cm $H_2O$ of external PEEP ($16{\pm}2$ vs $22{\pm}3\;cm$ $H_2O$, p=0.008). $V_T$, $V_E$, PEFR, $T_I/T_{TOT}$ and Cdyn did not change significantly. Conclusion : The presence of auto-PEEP in mechanically ventilated patients was accompanied with increased WOB performed by patient, and this WOB was decreased by 3 cm $H_2O$ of externally applied PEEP. But, with 3 cm $H_2O$ of external PEEP, increased PIP was noted, implying the importance of close monitoring of the airway pressure during application of external PEEP.

  • PDF

Breathing Reserve Index at Anaerobic Threshold of Cardiopulmonary Exercise Test in Chronic Obstructive Pulmonary Disease (만성폐쇄성 폐질환의 운동부하 심폐기능검사에서 무산소역치 예비호흡지수의 의의)

  • Lee, Byoung-Hoon;Kang, Soon-Bock;Park, Sung-Jin;Jee, Hyun-Suk;Choi, Jae-Chol;Park, Yong-Bum;Ahn, Chang-Hyuk;Kim, Jae-Yeol;Park, In-Won;Choi, Byung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.795-802
    • /
    • 1999
  • Objective : Cardiopulmonary exercise test is a useful tool to evaluate the operative risk and to plan exercise treatment for the patients with chronic obstructive pulmonary disease(COPD). In cardiopulmonary exercise test, most of the measured parameters are recorded at the time of peak exercise, which are hard to attain in COPD patients. So we evaluated the usefulness of the parameter, breathing reserve index(BRI=minute ventilation [$V_E$]/maximal voluntary ventilation[MVV]) at the time of anaerobic threshold($BRI_{AT}$) for the differentiation of COPD patients with normal controls. Methods : Thirty-six COPD patients and forty-two healthy subjects underwent progressive, incremental exercise test with bicycle ergometer upto possible maximal exercise. All the parameters was measured by breath by breath method. Results : The maximal oxygen uptake in COPD patients (mean$\pm$SE) was $1061.2{\pm}65.6ml/min$ which was significantly lower than $2137.6{\pm}91.4ml/min$ of normal subjects(p<0.01). Percent predicted maximal oxygen uptake was 54.3% in COPD patients and 86.0% in normal subjects(p<0.01). Maximal exercise(respiratory quotient; $VCO_2/VO_2{\geq}1.09$) was accomplished in 7 of 36 COPD patients(19.4%) and in 18 of 42 normal subjects(42.9%). The $BRI_{AT}$ of COPD patients was higher($0.50{\pm}0.03$) than that of control subject($028{\pm}0.02$, p<0.01), reflecting early hyperventilation in COPD patient during exercise. The correlation between $BRI_{AT}$ and BRI at maximal exercise in COPD patients was good(r=0.9687, p<0.01). Conclusion : The $BRI_{AT}$ could be a useful parameter for the differentiation of COPD patients with normal controls in the submaximal cardiopulmonary exercise test.

  • PDF

Exposure status of welding fumes for operators of overhead traveling crane in a shipyard (대형조선소 천장크레인 운전원의 용접흄 노출 실태)

  • Lee, Kyeongmin;Kim, Boowook;Kwak, Hyunseok;Ha, Hyunchul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.301-311
    • /
    • 2015
  • Objectives: Operators of overhead traveling crane in a ship assembly factory perform work to transmit large vessel blocks to an appropriate working process. Hazardous matters such as metal dusts, carbon monoxide, carbon dioxide, ozone, loud noise and fine particles are generated by variable working activities in the factory. The operators could be exposed to the hazardous matters during the work. In particular, welding fumes comprised of ultra fine particles and heavy metals is extremely hazardous for humans when exposing a pulmonary through respiratory pathway. Occupational lung diseases related to welding fumes are increasingly on an upward tendency. Therefore, the objective of this study is to assess properly unknown occupational exposure to the welding fumes among the operators. Methods: This study intended to clearly determine an equivalence check whether or not chemical constituents and composition of the dusts, which existed in the driver's cab, matched up with generally known welding fumes. Furthermore, computational fluid dynamics program(CFD) was used to identify a ventilation assessment in respect of a contamination distribution of welding fumes in the air. The operators were investigated to assess personal exposure levels of welding fumes and respirable particulate. Results: The dust in an operation room were the same constituents and composition as welding fumes. Welding fumes, which caused by the welding in a floor of the factory, arose with an ascending air current up to a roof and then stayed for a long time. They were considered to be exposed to the welding fumes in the operation room. The personal exposure levels of welding fumes and respirable particulate were 0.159(n=8, range=0.073-0.410) $mg/m^3$ and 0.138(n=8, range=0.087-0.178) $mg/m^3$, respectively. They were lower than a threshold limit value level($5mg/m^3$) of welding fumes. Conclusions: These findings indicate that an occupational exposure to welding fumes can exist among the operators. Consequently, we need to be keeping the operators under a constant assessment in the operator process of overhead traveling crane.

Exposure to Volatile Organic Compounds and Possibility of Exposure to By-product Volatile Organic Compounds in Photolithography Processes in Semiconductor Manufacturing Factories

  • Park, Seung-Hyun;Shin, Jung-Ah;Park, Hyun-Hee;Yi, Gwang-Yong;Chung, Kwang-Jae;Park, Hae-Dong;Kim, Kab-Bae;Lee, In-Seop
    • Safety and Health at Work
    • /
    • v.2 no.3
    • /
    • pp.210-217
    • /
    • 2011
  • Objectives: The purpose of this study was to measure the concentration of volatile organic compound (VOC)s originated from the chemicals used and/or derived from the original parental chemicals in the photolithography processes of semiconductor manufacturing factories. Methods: A total of four photolithography processes in 4 Fabs at three different semiconductor manufacturing factories in Korea were selected for this study. This study investigated the types of chemicals used and generated during the photolithography process of each Fab, and the concentration levels of VOCs for each Fab. Results: A variety of organic compounds such as ketone, alcohol, and acetate compounds as well as aromatic compounds were used as solvents and developing agents in the processes. Also, the generation of by-products, such as toluene and phenol, was identified through a thermal decomposition experiment performed on a photoresist. The VOC concentration levels in the processes were lower than 5% of the threshold limit value (TLV)s. However, the air contaminated with chemical substances generated during the processes was re-circulated through the ventilation system, thereby affecting the airborne VOC concentrations in the photolithography processes. Conclusion: Tens of organic compounds were being used in the photolithography processes, though the types of chemical used varied with the factory. Also, by-products, such as aromatic compounds, could be generated during photoresist patterning by exposure to light. Although the airborne VOC concentrations resulting from the processes were lower than 5% of the TLVs, employees still could be exposed directly or indirectly to various types of VOCs.