• Title/Summary/Keyword: ventilation systems

Search Result 432, Processing Time 0.024 seconds

Performance of Local Exhaust Ventilation Systems of Degreasing and Plating Workplaces (일부 탈지세척 및 도금공정 국소배기장치의 성능점검과 개선방안)

  • Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.178-185
    • /
    • 1998
  • In order to evaluate and improve the performance of local exhaust ventilation systems for two TCE degreasing (A, B) and two electroplating (C, E) and one acid dipping & plating (D) operations located in Kimhae, the performance test was conducted with trace gases and a thermal anemometer (Kanomax 24-6111, Japan). For the inadequately designed systems, the improvement and redesigns in compliance with recommendation by ACGIH was suggested. The results of performance test for each system are as follows; 1. System of Workplace A was generally well-designed. Actual exhaust air flow rate was in excess of 68% above the recommended standard exhaust air flow rate. 2. System of Workplace B was very well-designed and completely enclosed. 3. All systems of Workplace C including hoods were poorly-designed and actual exhaust air flow rates were insufficient for open tanks. All systems should be upgraded according to ACGIH recommendations. 4. Supply and exhaust air flow rate of push-pull exhaust systems in Workplace D should be greatly increased. The width of flange of dipping tank hood should be increased with the value suggested. 5. System of Workplace E was well-designed. Actual exhaust air flow rate was in excess of 54% above the required.

  • PDF

An Experimental Study of Smoke Movement in Tunnel Fire with Natural and Forced Ventilations (자연 및 강제 배기시의 터널 내 연기거동에 관한 실험적 연구)

  • Hwang Cheol-Hong;Yoo Byung-Hun;Kum Sung-Min;Kim Jung-Yup;Shin Hyun-Joon;Lee Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.711-721
    • /
    • 2005
  • In order to design of emergency ventilation systems, the smoke movements in tunnel fire with natural and forced ventilation were investigated. Reduced-scale experiments were carried out under the Froude scaling with novel fire source consisting many wicks. Temperature profiles were measured under the ceiling and vertical direction along the center of the tunnel and poisonous gases were measured at emergency exit point in the natural ventilation case. In forced ventilation, temperature profiles were measured with various flow rate to obtain critical velocity. The results showed that the interval of emergency exit having 225m was estimated reasonably through the measurements of temperature variation and poisonous gas in the natural ventilation. In the case of forced ventilation, the temperature distribution near fire source is remarkably different from that of natural ventilation. Also, the critical velocity to prevent upstream smoke flow has the range of 0.57m/s between 0.64m/s. Finally, it was also identified that although the increase of flow rate can suppress the backward flow of smoke to upstream direction, brings about the increase of flame intensity near stoichiometric fuel/air ratio.

A Study on the Ventilation Method for a Factory with a Sealed Structure

  • Kim, Yeong-Sik;Yi, Chung-Seob;Lee, Dae-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.159-165
    • /
    • 2014
  • On this work, the importance of industrial ventilation was investigated and examined the theoretical point and problems about general ventilation of factory exposed on high temperature during summer. As a case study, the ventilation planning of the printed circuit board (PCB) etching process for an electronic company was carried out and each of those characteristics were compared by installing actual ventilation systems and measuring the changing state of the working environment in accordance with ventilation method during summer. The purpose of the study is to present an efficient ventilation method for a factory with a closed structure under high temperature environment. In summary, for a factory with a sealed structure such as the target PCB manufacturing factory in this study, the forced supply and exhaust method was the most appropriate ventilation method for maintaining a low.

A Study on the Variation of Ventilation Effect for Indoor Air Pollutants by Ventilation Hole Sites (환기구 위치별 실내오염물질의 환기효과 변동에 관한 연구)

  • Lee, Jeong Joo;Lee, Ju Sang;Kim, Shin Do
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.226-240
    • /
    • 1995
  • This research has a purpose to achieve experimental data used for design of ventilation systems necessary for indoor air quality control and their operation and management. For the study, spatial concentration distribution of indoor air quality according to pollutant site in a simplified model chamber. In low flow ventilation, flow pattern of indoor air was mainly influenced by diffusion and additionally, spatial distribution was formed by convection. Distribution of ventilation efficiency according to each pattern of model chamber was evaluated. It was confirmed that diffusion patterns of a pollutant among sites were formed, centering around main stream areas of supply and exhaust outlets.

  • PDF

The Study on Optimum Ventilation System during Long Tunnel Construction (굴착중인 장대터널 내 최적의 환기시스템에 관한 연구)

  • Lim, Han-Uk;Oh, Byung-Hwa
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.3-15
    • /
    • 2006
  • To determine the optimum ventilation systems during long tunnel excavation, the velocity vector profile and the contaminant's distribution at working place are studied using 2-D, 3-D numerical analysis. The main results can be summarized as follow; In case of long tunnels, blower-exhaust-mixture types which enable to use soft blast ducts is most appropriate in terms of ventilation and economical efficiency. Of the same ventilation types, ventilation efficiency has a difference according to blast ducts and the distance between fan and working place. The 3-D numerical result shows that arranging blower and exhaust ducts in the right and left corners of the tunnel respectively is effective to discharge contaminant. The result of the real measurement shows that CO concentration can be reduced to below 50 ppm, which is regulation value, as 16-minutes fan operation goes on.

  • PDF

On the Prediction of Ventilation Characteristics in case Diesel Trains Run in Double Track Subway Tunnels (복선전철 구간 내 디젤차량 운행시 환기특성 예측에 관하여)

  • Hong, S.W.;Kim, H.G.;Kim, N.Y.;Lee, S.B.;Kwon, T.S.
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.270-275
    • /
    • 2007
  • Pollutants emitted by Diesel trains seriously affected on the ventilation characteristics in the subway or railway tunnel network systems. Thus, numerical prediction results and analyses are required to engineers who should design ventilation facilities. So here, this paper presents some numerical results about the ventilation characteristics, such as pollutants distributions and a suitability of the ventilation facilities pre-designed in case that diesel trains use the same railway track with normal passenger trains

  • PDF

Development of Automated Modeling System for Air-Ventilation Holes (열 배출구 형상 모델링 자동화 시스템 개발)

  • Park, Hyun-Pung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.14 no.5
    • /
    • pp.330-337
    • /
    • 2009
  • Nowadays a lot of high-tech electronic products such as TVs, monitors and camcorders are being developed. The more functions the electronic devices have, the more heat problems occur. Therefore, most of electronic products have air-ventilation holes to eliminate heat that is generated inside the products. The shapes of ventilation holes are usually complicated since aesthetic appearance of the products is important these days. In order to create those complicated shapes, designers should do time-consuming jobs because most of commercial CAD systems do not provide the functions that create patterns of lofted parts along freeform surfaces. In this research, an automated air-ventilation hole modeling system was proposed. The system generates patterns of lofted objects on freeform surfaces. Standard process to create air-ventilation holes manually was established, and vent-hole types and pattern types were classified into several categories. Designers can create many kinds of vent-holes by combining vent-hole types and pattern types. Users can also utilize user-defined pattern which can give users more flexibility. Developed system was applied to several design examples and the results are presented.

An Experimental Study on the Ventilation Performance to Enhance Removal Efficiency of Indoor Hamful Gases (실내 유해가스 제거효율 향상을 위한 환기성능에 관한 실험적 연구)

  • Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.117-124
    • /
    • 2009
  • The objective of this research is to analyze the ventilation performance of mechanical ventilation systems to enhance removal efficiency of indoor hamful gases. The ventilation performance is evaluated using a step-down method based on ASTM Standard E741-83. The ventilation performance is evaluated as a function of the ventilation rate and supply/extract locations using a tracer gas ($CO_2$) technique. As a result, the $CO_2$ concentration as a function of time is decayed exponentially and the ventilation performance is found to increase with increased the ventilation rate. The ventilation performance of the second type ventilation system is better than that of the first type or the third type. The ventilation performance without human occupancy increases up to 55% and the ventilation performance with one person increases up to 25% at the supply air of 570Lpm comparing with a natural reduction after one hour in the test chamber. The ventilation performance is better than 15% comparing with natural decay at the supply of 570Lpm in an office room.

Sustainable Tall Buildings: Summary of Energy-Efficient Design

  • Kheir Al-Kodmany;Mir M. Ali;Paul J. Armstrong
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.2
    • /
    • pp.107-120
    • /
    • 2023
  • Tall buildings are frequently decried as unsustainable due to their excessive energy usage. Early skyscrapers used natural light and ventilation to facilitate human comfort and applied organic materials such as stone, glass, wood, concrete, and terra cotta for cladding and finishes. With the advent of fluorescent lighting, modern heating, ventilation, air-conditioning (HVAC) systems, and thermally sealed curtain walls, tall office buildings no longer had to rely on natural light and ventilation to provide comfort. Energy efficiency was not a significant factor when the operational costs of buildings were relatively inexpensive. However, today's skyscrapers must become more energy-efficient and sustainable due to energy crises and climate change. This paper highlights vital energy-efficient design principles and demonstrates with illustrative case studies how they are applied to tall buildings in various parts of the world. It shows how sustainable environmental systems do not act alone but are integrated with advanced curtain wall systems, sky gardens, and atria, among others, to regulate and sustain thermal comfort and conserve energy.

A Study on the Performance Evaluation of the Hybrid Ventilation System for Small Apartment Houses (소형 공동주택의 하이브리드 환기시스템 성능실험 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Lee, Jong-Sung;Kim, Sang-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.696-701
    • /
    • 2008
  • From Feb. 2006, the ventilating systems with air exchange rate of over 0.7times/hour are installed at the apartment houses (over 100 units). Installation cost and maintenance cost are very important factors for ventilating system because consumers have to pay the expenses of that system. Especially small apartment needs more considerations because small apartment is comparatively the economically weak part. The purpose of this study is to the performance evaluation of the hybrid ventilation system for small apartment houses. Hybrid system 1 consists of natural ventilation system and duct type exhaust diffusers. Hybrid system 2 has natural ventilation system and toilet exhaust system with static pressure fan. Infiltration of test apartment houses with ventilation system is under 0.1 times/hour. Mean air age of hybrid system 1 is 1.52 hours and hybrid system 2 is 1.42 hours. Mean ventilation effectiveness of hybrid system 2(93%) is higher than that of hybrid system 1(81%).