• 제목/요약/키워드: ventilation house

검색결과 302건 처리시간 0.024초

대학교 신축 기숙사의 휘발성유기화합물 농도 및 새집증후군 반응 (The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory)

  • 최윤정;오예슬;장윤정;김정재
    • 한국주거학회논문집
    • /
    • 제20권6호
    • /
    • pp.135-143
    • /
    • 2009
  • The purposes of this study were to determine the actual state of the indoor air quality by measuring TVOC Concentration and surveying residents' responses in a newly built university dormitory and to analyze the influencing factors of IAQ. Field measurements on the concentrations of TVOC and HCHO were carried out three times at 4 week intervals in 3 rooms of a dormitory. A questionnaire survey was conducted on residents which inquired into the resident's lifestyle, their consciousness of IAQ, and the responses to SHS. According to the results, TVOC concentrations were 0.14~18.5 ppm and HCHO concentrations were 0.23~6.89 ppm during the 3 months following the completion of construction, showing a serious state in which standard levels are exceeded, though these levels seemed to decrease over time. The factors influencing the differences in the levels of TVOC and HCHO were the ventilation volume including infiltration, the heating temperature, relative humidity, or the use of living matter that include chemical ingredients. However, the residents rarely felt the symptoms of SHS and were not conscious of the importance of ventilation.

육성$\cdot$비육돈사 내에서 환기형태별 환경조사 연구 (Effects of Ventilation Systems on Interior Environment of the Growing-finishing Pig House in Korea)

  • 송준익;유용희;정종원;김태일;최희철;강희설;양창범;이영윤
    • 한국축산시설환경학회지
    • /
    • 제10권2호
    • /
    • pp.93-100
    • /
    • 2004
  • 본 연구는 우리나라에 건축되어져 있는 개방식 육성$\cdot$비육돈사나 무창식 육성$\cdot$비육돈사에 대한 효율 비교분석 연구가 없는 실정으로 개방식 육성$\cdot$비육돈사와 무창식 육성$\cdot$비육돈사의 환경효율을 검증하고자 하였다. 겨울철과 여름철로 나누어 실시한 실험결과는 다음과 같다. 1. 무창식 육성 비육돈사는 외부의 기온 변화가 심하더라도 돈사내부의 온도는 외부기온의 영향을 받지 않고 여름철 $31.8\~33.8^{\circ}C$, 겨울철 $17.9\~19.5^{\circ}C$를 유지하였으나 개방식 육성$\cdot$비육돈사는 여름철 32.1$\~$32.9, 겨울철 $15.8\~16.7^{\circ}C$를 유지하여 온도효율이 낮았다. 2. G2, G4 육성$\cdot$비육돈사는 돼지생활 공간(하부) 지점에서의 공기유속은 겨울철 최소환기($5\%$) 수준으로 하였을 때 0.2$\~$0.3 m/s 였으며, 여름철 최대환기($95\%$) 수준에서는 0.5$\~$0.6 m/s로 분포되어 여름철 및 겨울철의 육성$\cdot$비육돈사내 공기유속이 G1, G3 육성$\cdot$비육돈사보다 양호하였다. 3. 암모니아 농도를 측정한 바 G2, G4 육성$\cdot$비육돈사는 여름철 13.3$\~$16.6 ppm, 겨울철14.0$\~$~14.6 ppm으로 측정되었으며, G1, G3 육성$\cdot$비육돈사는 여름철 14.6$\~$20.3 ppm, 겨울철 20.3$\~$25 ppm을 유지하여 G1, G3 육성$\cdot$비육 돈사보다는 낮게 나타났다.

  • PDF

공동주택 리모델링을 위한 수익모델의 기능성 평가 연구 (A Study on Functionality Evaluation of Profit Model for Remodeling of Apartment House)

  • 안민재;표지명;김의식
    • 한국건축시공학회지
    • /
    • 제5권2호
    • /
    • pp.107-113
    • /
    • 2005
  • This study analyzes remaining repair rate and applied repair rate with the presentation of profit model for the purpose of pursuing maximization of added value through remodeling of apartment house. Objects of remodeling and item applying the whole replacement of functionality evaluation items include exterior of building (3 items maintaining the current conditions, 8 items requiring the whole replacement), water supply/sanitary/gas/ventilation facilities (6 items maintaining the current conditions, 6 items requiring the whole replacement, electric/fire fighting/elevator facilities (8 items maintaining the current conditions, 20 items requiring the whole replacement) and heating/water heater facilities (2 items requiring the whole replacement).

都市 超高層 住居建築의 室內空氣環境의 評價에 관한 硏究 (A Study on the Evaluation of Indoor Air Environment in Super High-Rise Dwelling House)

  • 박미진
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.119-125
    • /
    • 2002
  • The concept of dwelling space is tend to be changed not only to have reasonable mobility but also to have high quality of indoor air with psychologicaa satisfaction and comfortable. Moreover, recent constructed buildings have a big problem because of exhausted pollution gas and particles from building materials. More serious problem occurs from its high air tightness reducing the ventilation for saving the energy and superior adiabatic insulators to have high heat efficiency. Indoor air quality in super high-rise dwelling house was investigated by measuring pollutants such as $CO_2,=;CO,\;MO_2,\;R_n,\;TSP,\;PM_{10}$, HCHO, Offensive ordor. Subjective evaluation of residential environment is processed for the inhabitants who live in research space by testing environmental load in accordance with environment morphology, exterior environmental factor and post occupancy correlation and influence of attention.

계절적 라돈농도 변화 및 토양기원 실내라돈과 토양내 라돈농도의 상관성 분석 -단독주택 사례연구- (Seasonal Radon Concentration and Correlation Analysis of Indoor Radon Originated from Soil and Soil Radon at Detached House)

  • 조주현;김영희
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권5호
    • /
    • pp.105-111
    • /
    • 2017
  • In this study, the variation of indoor and soil radon concentrations were measured at a test bed (detached house), and correlation analysis was performed using linear regression. The results showed that the average concentration of indoor radon was increased by about 20% when the heater was operated in the house, but it was decreased by 15% when the ventilation system was on. In the changes of seasonal radon concentrations, soil and indoor radon concentrations in winter were higher than in summer. Statistical analysis showed a weak correlation between the soil radon and indoor radon, but the correlation (R=0.852, $R^2=0.726$) was relatively high at exhaust condition in the winter. It is difficult to extrapolate the results of the study to the general cases because radon distribution is highly site-specific, but the result of this study could be used as a reference for radon management and reduction of detached house in the future investigations.

패시브 디자인을 적용한 ICF공법 주택의 난방에너지 성능 분석 (An Analysis of Heating Energy Performance in Housings of ICF Method with Passive Design Applied)

  • 김준희;이태구
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.33-40
    • /
    • 2013
  • The world population is consuming more than 1/3 of the total energy for heating housings. Particularly in our country, 21% of the consumption energy is occupied by building section. Therefore, it is necessary to increase the energy efficiency in buildings, thus promoting a comfortable residential environment while minimizing energy consumption. Accordingly, this study presents considerations for implementing high-insulated and airtight passive houses. This study selected four houses with passive house design applied, performed building energy performance through PHPP2007, a German passive house design simulation program, and compared the building-specific heat loss and heat gain. As a result, the most vulnerable part to heat loss was turned out to be a window and the heat loss was caused by outer wall, roof, and ventilation. Accordingly, for the implementation of passive house, it is necessary to make a careful plan and airtight construction that are complementary to various parts through the energy performance analysis started from the design phase.

버어리종 건조시 급건엽발생방지에 관한 연구 III. 환기조건이 급건엽발생에 미치는 영향 (Studies on the Prevention of Excessive Drying Leaves during Burley Tobacco Curing III. Effect of the Ventilating Conditions on the Occurrence of Excessive Curing Leaves)

  • 배성국
    • 한국작물학회지
    • /
    • 제32권2호
    • /
    • pp.130-136
    • /
    • 1987
  • 공시품종인 Burley 21을 수확한 후 건조하고 무더운 시기에 처리하여 건조하우스의 환기시기, 환기량 및 달줄간격 등의 건조실관리에 따른 급건조방지 방법을 밝히고자 시험한 결과 요약하면 다음과 같다. 1. 건기에는 건조시 시종환기구에서 온도가 낮았고 급건엽발생도 제일 적었다. 2. 급건엽발생시기는 황변말부터 갈변말까지로 이 시기에 탈수를 지연시키는 것이 가장 중요하다. 3. 급건엽발생이 적을수록 품질 및 물리성이 양호하였다. 4. 측면을 1.5m로 충분히 환기시킨 구에서 급건엽발생이 가장 적었다. 5. 달줄간격을 좁힐수록 온도에는 크게 영향을 미치지 않았으나 온도는 높게 유지하여 급건엽발생을 크게 감소시켰다. 6. 급건엽의 내용성분은 충분히 분해가 일어나지 않았다.

  • PDF

Indoor air quality and ventilation requirement in residential buildings: A case study of Tehran, Iran

  • Ataei, Abtin;Nowrouzi, Ali;Choi, Jun-Ki
    • Advances in environmental research
    • /
    • 제4권3호
    • /
    • pp.143-153
    • /
    • 2015
  • The ventilation system is a key device to ensure both healthful indoor air quality (IAQ) and thermal comfort in buildings. The ventilation system should make the IAQ meet the standards such as ASHRAE 62. This study deals with a new approach to modeling the ventilation and IAQ requirement in residential buildings. In that approach, Elite software is used to calculate the air supply volume, and CONTAM model as a multi-zone and contaminant dispersal model is employed to estimate the contaminants' concentrations. Amongst various contaminants existing in the residential buildings, two main contaminates of carbon dioxide ($CO_2$) and carbon monoxide (CO) were considered. CO and $CO_2$ are generated mainly from combustion sources such as gas cooking and heating oven. In addition to the mentioned sources, $CO_2$ is generated from occupants' respirations. To show how that approach works, a sample house with the area of $80m^2$ located in Tehran was considered as an illustrative case study. The results showed that $CO_2$ concentration in the winter was higher than the acceptable level. Therefore, the air change rate (ACH) of 4.2 was required to lower the $CO_2$ concentration below the air quality threshold in the living room, and in the bedrooms, the rate of ventilation volume should be 11.2 ACH.

인도 중정형 주택의 공간 구조와 기후의 연관성에 관한 연구 - 고온 건조 지역과 고온 다습 지역의 중정형 주택을 중심으로 - (A Study on the Relationship between the Climate and Space Organization of India Courtyard Housing - Focused on the Courtyard housings in Hot-dry Region and Hot-humid Region -)

  • 최시인;이윤희
    • 한국실내디자인학회논문집
    • /
    • 제23권6호
    • /
    • pp.3-13
    • /
    • 2014
  • The purpose of this study is to compare and analyse the difference between courtyard housings of hot-humid region and hot-dry region in India, in order to identify the affection of climate on the space arrangement of housing. The study starts from the curiosity about similar space structure of Indian housings at different climate area. Indian housings usually have courtyard at the center of its plan, though the 'Courtyard housing' is typical form of dry region's house type. Research method is comparative analysis of traditional houses of India, and the samples are selected from hot-dry city, Ahmedabad and hot-humid city, Bangalore. The conclusion is drawn through comparing main houses with traditional houses of other dry city - Jaipur - and humid cities - Trivandrum and Nilambur. It shows that both dry and humid region's housings has courtyard in common, but their spatial structures are not same at all. Houses of dry region shows organically connected spatial form, in order to maximize the cooling effect of ventilation. In contrast, the plan of houses in humid region shows opened, but can be closed in any time to prevent the penetration of moisture. Both Parekh house(Ahmedabad) and Koramangala house(Bangalore) left inconvenience of its arrangement, though the ventilation of air is the most important point of sustainability in hot region. The study could be the practical reference data for advanced sustainable housings of India which may built in the future.

비육돈사 작업 종사자의 호흡기 관련 공기 중 분진 농도 측정 및 분석 (Measurement and Analysis of Dust Concentration in a Fattening Pig House Considering Respiratory Welfare of Pig Farmers)

  • 권경석;이인복;황현섭;하태환;하정수;박세준;조예슬
    • 한국농공학회논문집
    • /
    • 제55권5호
    • /
    • pp.25-35
    • /
    • 2013
  • In swine house, dust generation comes from various sources and is known to be harmful both for the animals and the farmers because the dust contains biological and gaseous matters. When farmers are constantly exposed to the dusts, they can suffer chronic or acute respiratory symptoms and have high probability of manifesting various diseases. To address this problem, understanding of the mechanism of dust generation is very important. In this paper, the dust concentration of inhalable, respirable, TSP and $PM_{10}$ were monitored and analyzed according to the pig-activity level, ventilation quantity and feeding method in fattening pig house. From the measured results, in case of the concentration of TSP, an inverse-linear relation with ventilation rate ($R^2=0.88$) and linear relation with the installation height of feed supply pipe ($R^2=0.73$) were determined. However in case of the concentration of $PM_{10}$, no particular relationship with the variables was observed. Using the concentration of inhalable and respirable dust based on the pig-activity level, multi-variate regression analysis was conducted and results have shown that the movement of pigs can contribute to the dust generation (p<0.05, $R^2=0.71$, 0.61). The relationship determined between dust generation and environmental variables investigated in this study is very significant and useful in conducting dust-reduction researches.