• 제목/요약/키워드: ventilation equipment

검색결과 202건 처리시간 0.031초

A Study on Ways to Improve the Smell of Pig Barn

  • Min-Jae JUNG;Su-Hye KIM;Young-Do KIM
    • 웰빙융합연구
    • /
    • 제6권2호
    • /
    • pp.9-13
    • /
    • 2023
  • Purpose: In this study, we would like to make a technical proposal to solve the odor problem in pig houses. Through this, we would like to suggest an effective way to reduce the odor generated in the pig house as a solution to civil complaints. Research design, data and methodology: Conduct direct visits to pig farms where many civil complaints about bad odor occur, and identify the problems of each farm. Identify elements related to odor control, such as structure, facility, equipment, odor management method, and ventilation type. Through this, the technology to be applied to reduce odor and the solution to the odor problem are presented. Results: The results of major improvements are as follows: 1. Improvement of the structure of the barn or composting shed to an airtight type 2. Improvement of the pig manure treatment structure using the slope inside the barn 3. Establishment of ventilation and cooling systems 4. Automation of the mist spray system. Conclusions: As a result, as practical measures, sealing of facilities using winch curtains, construction of air conditioning systems using negative pressure ventilation, and management systems using AIoT systems were presented. It is judged that this study can be helpful in determining the grievances caused by civil complaints of tenant livestock farms and the direction of facility improvement in the future.

울산광역시 학교급식 조리 환경에 대한 조리사의 인지도 조사 (On the Cooks' Recognition of Culinary Environment of School Feeding in Ul-san)

  • 김해정;유경민
    • 한국조리학회지
    • /
    • 제14권1호
    • /
    • pp.94-106
    • /
    • 2008
  • This study is conducted to explore the cooks' recognition of culinary environment of school feeding among the cooks working for elementary schools, middle schools, and high schools in the Ulsan district. A total of 200 samples were distributed and 185 samples were collected; among them, 182 valid samples were selected for research. Answers were processed by SPSS 12.0. after data coding. As for factor analysis of culinary environment, three factors were extracted, which are general environment, human environment, and facilities equipment environment. It was found that general environment included ventilation(31.5%), temperature (29.0%), humidity(22.1%) in the order of importance; human environment covered cooperation among cooks (28.1%), the number of cooks(25.7%), and professionalism of cooks in the order of importance; facility equipment environment contained the design and layout of facilities and equipment(29.3%), various safety facilities, and safety device(23.3%) in the order of importance. However, a measure for improving work environment, number of cooks, deterioration of equipment, etc. should be considered.

  • PDF

시분할 CNN-LSTM 기반의 시계열 진동 데이터를 이용한 회전체 기계 설비의 이상 진단 (Anomaly Diagnosis of Rotational Machinery Using Time-Series Vibration Data Based on Time-Distributed CNN-LSTM)

  • 김민기
    • 한국멀티미디어학회논문지
    • /
    • 제25권11호
    • /
    • pp.1547-1556
    • /
    • 2022
  • As mechanical facilities are interacting with each other, the failure of some equipment can affect the entire system, so it is necessary to quickly detect and diagnose the abnormality of mechanical equipment. This study proposes a deep learning model that can effectively diagnose abnormalities in rotating machinery and equipment. CNN is widely used for feature extraction and LSTMs are known to be effective in learning sequential information. In LSTM, the number of parameters and learning time increase as the length of input data increases. In this study, we propose a method of segmenting an input segment signal into shorter-length sub-segment signals, sequentially inputting them to CNN through a time-distributed method for extracting features, and inputting them into LSTM. A failure diagnosis test was performed using the vibration data collected from the motor for ventilation equipment installed at the urban railway station. The experiment showed an accuracy of 99.784% in fault diagnosis. It shows that the proposed method is effective in the fault diagnosis of rotating machinery and equipment.

멀티존 시뮬레이션에 의한 공동주택의 미생물 오염원 확산과 제거에 관한 연구 (A Study on the Diffusion and Removal of Airborne Microorganism Pollution in Multistoried Apartment by the Multi-Zone Simulation)

  • 홍진관;최상곤
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.291-298
    • /
    • 2007
  • The purpose of this study is to evaluate the efficacy of multizone simulation that enables to grasp of details about microbial contaminant problem in an multistoried apartment. We used actual indoor test data to figure up microbial contaminant level as initial value for the multizone simulation and estimated the various effects of indoor occupant infected with germs such as bacteria and fungus and the performance of air sterilization by using multizone simulation in substitute for infeasible experimental approach. The results show that natural ventilation make ourselves generally useful for removing indoor microbial contaminants. The results also show that the performance of air sterilization reach the maximum in the case of using mechanical ventilation and UVGI air sterilizer. The conclusion is that this multizone simulation is useful tool for actual design method for immune building systems.

작업장 환기장치 최적화 유동 연구 (A Numerical Optimization Study on the Ventilation Flows in a Workshop)

  • 엄태인;장동순
    • 한국안전학회지
    • /
    • 제10권1호
    • /
    • pp.64-73
    • /
    • 1995
  • A preliminary study is performed in order to design an effective ventilation equipment for the control of possible pollutants in a workshop. To this end, the Patankar's SIMPLE methodology is used to investigate the flow characteristics of the contaminated thermal deflected jet which is encounted often in practical hood system. SIMPLE-Consistent algorithm is employed for the pressure-velocity coupling appeared in momentum equations. A two equation, k-$\varepsilon$ model is used for Reynolds stresses. The prediction data is compared well against the experimental results by Chang(1989). Considering the control of the wake due to its high turbulence together with the stagnant feature has been investigated in term of major parameters such as temperature and magnitude of the discharge velocity. Detailed discussions are made to reduce the size of the wake region which give rise to pollutant concentration stratification.

  • PDF

크랭크실 환기장치의 오일 분리효율에 관한 연구 (A Study on Oil Separation Performance of Crank-Case Ventilation System)

  • 서준호;나병철;김진용;박승욱;임대순
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.144-150
    • /
    • 2008
  • This research aims to develop parts for advanced fuel/oil filtering re-circulation applicable to this kind of regulation proof engines. These parts can playa role of converting traditional air emission type crankcase into recovery type crankcase so that the engine can deal with environmental regulations, which do not allow minimal amount of toxic gas discharge. For the experiment, test method and specially made testing equipment are prepared. The results showed that oil separation efficiency of the cone type CCV(Crank Case Ventilation) system was higher than one of cylinder type both in bench test and in engine.

전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구 (An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger)

  • 장영근
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

도시철도 역사개선에 관한연구 (A study on the subway-station improvement of metropolitan subway)

  • 김동원;박수중;이희성;문대섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1641-1646
    • /
    • 2007
  • Subway station is installed with equipment of deficient ventilation and air purification in need of routine activity for users because projectors didn't have recognition of the importance of prevention equipment on disasters in subway stations. So if the accident in Deagu is occurred again, we can't prevent it. And it is urgently necessary to improve antique subway station for the safety and service to citizens because users were increased far more. Improvement of subway station has to be modernized the backward and antique subway station and maintained and developed by the center of traffic to give the social contribution with management of social facilities. And subway station has to be made conveniently so that everyone may use the station with one-stop system including sales, business, service equipment. This study will show the improvement plan of problem in underground space and situation of metropolitan-train history to improve metropolitan-train station .we will study a traffic line and equipment relocation of underground space considering safety by choosing the improved station and problems of the underground station in seoul. And then we will study the improvement plan of air purification and sound isolation to upgrade service in citizens.

  • PDF

도로터널 화재시 차량의 항력계수가 제연용 제연팬에 미치는 영향에 대한 해석적 연구 (A numerical study on effects of drag coefficient of vehicle on jet fans in case of fire in road tunnels)

  • 유용호;유지오;김효규
    • 한국터널지하공간학회 논문집
    • /
    • 제16권6호
    • /
    • pp.553-560
    • /
    • 2014
  • 도로터널에서는 환기 및 제연을 목적으로 제연펜을 설치하고 있다. 제연펜 용량(제트팬 댓수)은 환기저항 및 승압력이 평형이 되는 상태에서 결정되게 된다. 터널에 운행중이거나 정지된 차량에 의한 승압력 및 저항력은 차량의 항력계수에 영향을 받게 된다. 터널에서의 항력계수는 슬립스트림 효과(또는 shadow effect)와 폐색효과에 영향을 받게 되며, 환기팬 및 제연팬 산정시 이와 같은 효과를 적절히 고려하지 못하고 있는 실정으로 교통 환기력를 과대평가하고 있다. 이에 본 연구에서는 화재시 차량의 차간간격을 반영한 항력계수와 등가저항면적을 산정하기 위해서 터널에 실제로 차량이 정차하는 조건으로 모델링하여 수치해석을 통해 항력계수를 검토하였다. 본 연구 결과, 항력계수에 대형차량 혼입률이 미치는 영향은 명확하지 않으며, 등가저항면적은 현행 도로설계편람기준에 대비 약 86%, 또 구 기준인 한국도로공사 환기설계기준 대비 62.2%수준으로 감소하는 것으로 분석되었다.