• Title/Summary/Keyword: ventilating

Search Result 226, Processing Time 0.022 seconds

An Experimental Study on the Noise Characteristics and Reduction of a Ventilating Fan System (환기팬 시스템의 소음특성과 저감에 관한 실험적 연구)

  • Kim, Deok-Han;Lee, Dong-Hoon;Kwon, Hyuk-Jung;Kim, Dong-Yun;Lee, Jong-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.500-505
    • /
    • 2005
  • This paper introduces an experimental study for the noise characteristics and reduction of a ventilating fan system. For the purpose of noise reduction of it, an absorptive duct silencer filled with a glass fiber has been conventionally utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with their sound absorption performances.

  • PDF

Effect of Air Controlled Fermentation on Kimchi Quality (밀폐용기에서의 김치숙성에 관한 연구)

  • 김미경;김소연;우철주;김순동
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.23 no.2
    • /
    • pp.268-273
    • /
    • 1994
  • The quality of Kimchi was investigated under airtight and ventilating conditions. At 2$0^{\circ}C$ and 4$^{\circ}C$ fermentation, there were no significantly difference in pH, acidity and vitamin C of Kimchi between airtight and ventilating conditions. The contents of $CO_2$ , the number of lactic acid bacteria and the sensory score of carbonated taste under airtight condition were higher than those values under ventilating condition. While , the number of aerobic bacteria under airtight condition was lower than those under ventilating condition.

  • PDF

Clinical Analysis for 120 Cases with Pediatric Airway Foreign Bodies (유소아 기도 이물의 임상 양상과 환기형 기관지 내시경술의 결과 : 서울대 병원의 경험 120례)

  • Cha, Won-Jae;Choi, Hyo-Geun;Moon, Sung-Joong;Hah, J.-Hun;Sung, Myung-Whun;Kim, Kwang-Hyun
    • Korean Journal of Bronchoesophagology
    • /
    • v.12 no.2
    • /
    • pp.26-30
    • /
    • 2006
  • Backgroud and Objectives: Inhalation of foreign bodies in respiratory tract can be fatal to infants and child. After ventilating bronchoscopy technique was widelyused, most of the pediatric airway foreign bodies could be managed effectively. In this study, we aimed to analyze clinicalfeatures and outcomes of ventilating bronchoscopic removal of pediatric airway foreign bodies. Materials and Methods: One hundred twenty cases of ventilating bronchoscopy for pediatric airway foreign bodies at Seoul National University Hospital for the past 15 years were analyzed retrospectively. Results: In 120 cases, sex ratio (male: female) was 2.2:1 and mean age was 27.0 months. Most frequent type of airway foreign was peanut (60.2%). One hundred thirteen patients, in whom a foreign body was confirmed in the airway, were successfully managed by ventilating bronchoscopy. Delayed diagnosis and management made a significantly long postoperative hospital stay. Conclusion: Great care must be given when feeding young children, especially younger than 36 months, with nuts. Early intervention with ventilating bronchoscopy following a clinical suspicion is critical to successful treatment.

  • PDF

Evaluation on Thermal Environment Installed Ventilating Fans in the Rotunda at New National Museum of Korea (기류유인팬을 이용한 새 국립중앙박물관 로튠다에서의 열환경 평가)

  • 이승철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.303-309
    • /
    • 2004
  • In order to improve thermal comfort in the Rotunda, which is high and wide visiting space of the new national museum of Korea, eight ventilating fans were installed near the ceiling of Rotunda. It has been analyzed thermal comfort of Rotunda with/without ventilating fans by numerical simulation. To evaluate thermal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that temperature distribution of the case with fans is closer to target temperature than the case with-out fans at the breathing zone. In the case without fans, thermal stratification with 16$^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse and the PPD values reach up to 50% in the 6th floor connection passage. In the case with fans, however, the vertical temperature difference were reduced to 9$^{\circ}C$ and the PPD values were lower below 20%. Consequently, the ventilating fans adopted on this study are effectively used for improving the thermal comfort in large space structure with thermal stratification.

A Study on Fire ventilation design of road tunnel (도로터널에서의 화재환기 설계에 관한 연구)

  • Kim, Myung-Bae;Choi, Byung-Il;Choi, Jun-Seok;Han, Yong-Shik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.2
    • /
    • pp.129-139
    • /
    • 2004
  • The several assumptions and design parameters to determine the ventilation rate in tunnel ventilation system were examined. In longitudinal ventilating tunnel, the ventilation rate has been determined by the critical velocity above which the smoke propagation to the upstream of ventilating air is prevented. Based upon the examination of assumptions and experimental results, we suggested the improved method to determine the critical velocity. In transverse ventilating tunnel, we found that the ventilation rate has been determined in accordance with the custom rather than fire-smoke dynamics such as the critical velocity in the longitudinal ventilating tunnel. It is because the ventilation rate in the transverse ventilation system has been determined by considering only the ventilation of contaminant by vehicle. To improve the ventilation design parameters based upon the fire-smoke dynamics, we conducted model tunnel fire experiments. From the experimental results, smoke propagating distance and smoke filling were suggested as the design parameter to determine the ventilation rate in transverse ventilating tunnel. And tunnels in Europe designed by the custom is found to have the dangerous nature in view of fire safety.

  • PDF

Thermal Environment Analysis of a Room in Accordance with Ventilation Condition with Multi-Heat Sources (다수의 열원을 가지는 공간에서의 환기 조건에 따른 열환경 해석)

  • Kim, Jae-Jung;Son, Young-Gap;Chang, Seog-Weon;Ryu, Dong-Su
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.199-204
    • /
    • 2000
  • This paper reports a thermal environmental analysis of a room in accommodated with multi-heat sources according to ventilation condition. Two case modification have been investigated to obtain the lower temperature distribution in the room. The temperature distribution of the original room were found about $25{\sim}35^{\circ}C$. As a result, the use of, three ventilating fans and two electric fans are useful for room ventilation respectively, and using two electric fan is more recommendable in side of economical efficiency.

  • PDF

A Study on the Transmitted Noise Characteristics through the Ventilating Duct (환기용 덕트내의 전달소음 특성에 관한 연구)

  • Choi, Han-Lim;Kim, Kyung-Whan;Choi, Ho-Seon;Oh, Sai-Kee;Chung, Baek-Young
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.376-380
    • /
    • 2009
  • The transmission noise characteristics through the ventilating duct was conducted numerically using SYSNOISE. A ventilating system is usually composed of mufflers for preventing noise transmission from the ventilator into indoors through the ducts and distributors for transferring air to or from each room. The transmitted noise characteristics of distributors which have different branch angles and of mufflers having different shapes were analyzed numerically. New duct element combining a muffler and a T-shaped distributor was developed for better noise reduction in this paper. New element's performance was shown numerically.

  • PDF

Effects of Ventilation Condition and Ventilating Hole Sizes to Improve Quality Onion(Allium cepu. L) under Room Temperature (양파 간이저장시 통풍조건 및 통풍구 재료의 크기가 저장에 미치는 영향)

  • 이찬중;김희대;정은호;김우일;서전규
    • Food Science and Preservation
    • /
    • v.8 no.4
    • /
    • pp.356-361
    • /
    • 2001
  • This study was conducted to improve the storability of onion bulbs by assembly simple house storage and the reduce the rotteness caused by field open storage. Allium cepa cv. Changnyungdeago, late strain was used for the test at the storage condition of natural ventilation of levels 2, forced ventilation of levels 2, field open storage and 75mm, 100mm, and 125mm ventilating holes. Mean tamperature and relative humidity were not significantly different by ventilation conditions. Mean temperature was lower in forced ventilation than that of in natural ventilation and non-ventilation, and relative humidity was a little higher in ventilation treatment than those of the others. Weight loss of onion bulbs were 2.5%, 2.9%, 3%, 4.3% in field open storage, non ventilation, natural ventilation of levels 2 and forced ventilation of levels 2 respectively. Rotting rate in natural ventilation of levels 2 and farced ventilation of levels 2 were 27.7% and 25.4% respectively but 34.6% and 37.8% in non ventilation and field open storage. Therefore, the treatment of ventilation reduced the rotteness of storage onion bulbs. The smaller the size of a ventilating hole, the lower mean temperature was maintained. The relative humidity was some high in July, but didn’t showed significantly difference in August and September. With small size of a ventilating hole, the strong wind velocity was obtained, and wind velocity by position was weaker in the middle part than both ends. Rutting rates in 75㎜, 100㎜, and 125㎜ ventilating holes were 17.9%, 15.3% and 14.1% respectively.

  • PDF

Implementation for Automatic Inspection System on Ventilating Electronic Device Based on Reliability Improvement (신뢰성 향상 기반의 송풍전자장치 자동검사 시스템 구현)

  • Do, Nam Soo;Ryu, Kwang Ryol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.6
    • /
    • pp.1155-1160
    • /
    • 2017
  • This paper describes a system implementation for the automatic inspection on the ventilating electronic device based on the reliability improvement. To be enhancement, the inspection error is minimized by the automatic inspection system on the ventilating apparatuses against the manual inspecting system. The system consists of the control system, software structure and monitoring system to be scanning the inspection processing. The inspection system for reliability improvement is evaluated in Gage Repeatability and Reproducibility. The experimental results are improved about 2 times inspecting speed, measured error ${\pm}0.02V$, effectiveness of discriminating performance 15%, missing probability 17% and false alarm probability 12% respectively in comparing with the manual inspection based on the wind pressure sensor. The system will be also improved more by making database and product bar codes for the total quality control system to the effective reliability enhancement in the future.

Foreign bodies in air passage in Children (소아의 기도이물에 관한 통계적 관찰)

  • 유장열;오경균;백만기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.8.5-9
    • /
    • 1977
  • Foreign bodies in food and air passage, especially the latter in infants and children requires emergency treatment. The frequent symptoms are coughing, wheezing, and dyspnea, So may be confused as asthma, pneumonia and acute Laryngitis. The species and incidence of the foregin bodies are variable according to the age, method of life, environment and economic condition. The authors experienced 35 cases of foreign body in air passage during the period of last 3yrs which were treated by ventilating Bronchoscopy, and thoractomy in this hospital. One of them was lead to death. The authors analysed above cases and report with it's literature consideration. Results: 1. The prevalent foreign bodies were peanut, metal, food particles in order of frequency. 2. In frequent symptoms were dyspnea, coughing and wheezing in the order. 3. In the age incidence, 48% of the foreign bodies were 1∼5yrs. 4. In sex distribution, male to female ratio was 2.1: 1 5. In duration of lodgment, 65% of the foreign body were removed within 24hrs. 6. Most prevalent site of the foreign body was Rt. main bronchus Rt. to Lt. ratis was 2 : 1 was 7. Treatment was done; 25 cases were by ventilating bronchoscopy.

  • PDF