• Title/Summary/Keyword: venous blood sampling

Search Result 30, Processing Time 0.029 seconds

Comparison of C-reactive Protein between Capillary and Venous Blood in Children (소아에 있어서 C-반응성 단백의 모세혈 및 정맥혈 검사의 비교평가)

  • Jin, Ji Hoon;Jung, Soo Ho;Hong, Young Jin;Son, Byong Kwan;Kim, Soon Ki
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • Purpose : In evaluation of patients, laboratory results are crucial in determination of a treatment plan. Obtaining venous blood from infants and children is a difficult procedure. Substitution of a capillary blood sample for a venous blood sample has been suggested. However, there are few studies showing mutual correlation between C-reactive protein (CRP) results in capillary and venous blood. This study was designed to determine whether the result of the capillary sample is the same as the result of the venous blood sample. Methods : After informed consent, a pair of venous and fingertip capillary blood samples were simultaneously collected from 100 children. The LC-178CRPTM was used for analysis of capillary blood and the Hitachi 7180 automatic hematology analyzer was used for analysis of venous blood. We compared CRP of both venous and capillary blood samples. Results were analyzed by crosstabulation analysis, simple regression analysis and the Bland Altman Plot method. Results : A close correlation (90.63%) was observed between capillary and venous blood analyzed by crosstabulation analysis. CRP results were similar between the two groups and showed a high coefficient correlation ($\beta$=1.3434, $R^2$=0.9888, P<0.0001) when analyzed by a simple regression model. The average value in venous blood was also higher compared to capillary blood. According to Bland Altman Plot analysis, lab results were measured at a 95% confidence interval. Conclusion : CRP results from capillary blood showed close correlation with venous blood sampling. At present, venous blood sampling is the preferred method. However, due to difficulty in venous blood sampling, capillary sampling could be considered as an alternative technique for use with children.

Measurement Accuracy of Blood Glucose Test on the Forearm (전완 부위 혈당검사의 정확도 분석)

  • Park, Kyung-Soon;Song, Yeon-Yi;Park, Mi-Sook;Kim, Kyoung-Oak;Choi, Seong-Su;Kim, Kyung-Ah;Ryu, Jae-Duck;Cha, Eun-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2451-2459
    • /
    • 2009
  • The present study aimed to evaluate the accuracy of the blood glucose test with almost painless vacuum assisted auto-lancing technique. The blood glucose concentration measurements in the capillary blood sampled from the alternative (forearm) site were compared with the standard venous or finger sampling techniques. Capillary blood was sampled from both the left index finger and the forearm, followed by the venous blood sampling in 531 patients who visited the C University Hospital. Blood sugar test was performed for each blood samples for comparative analysis. Mean blood glucose concentration measured on the forearm was closer to the venous glucose level than that of the finger, but the difference was approximately 10 mg/dL small enough to ignore from the clinical point of view. The correlation coefficients of the measured blood glucose levels between finger and vein and between forearm and vein were 0.94 and 0.92, respectively (p<0.001). The blood glucose measurement on the forearm also well correlated with the finger, showing a correlation coefficient of 0.94, and both data were very much close to each other. Therefore, the blood sugar test on the alternative capillary blood sampling site such as forearm was accurate enough for clinical practice. The vacuum assisted auto-lancing technique on the alternative site would be of particular interest for the disease management of the chronic diabetes, since it induces almost no pain when sampling blood from the capillaries.

Accuracy Evaluation of the Alternative Site Blood Glucose Test Using Error Grid (에러그리드를 사용한 대체부위 혈당검사의 유용성 검증)

  • Park, Kyung-Soon;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • Blood glucose information is important for self regulation in daily life, but the frequency of self test remains to be only 17%(9 tests/month) in Korea, mainly due to pain during blood sampling. The present study tried to validate the clinical efficacy of the forearm as an alternative sampling site with minimized pain. Capillary blood was sampled both on the index finger($G_F$) and the forearm($G_A$), immediately followed by glucose measurements in 531 subjects, 25 who visited the Health Enhancement Center of C University Hospital, then venous blood($G_V$) was sampled for glucose test. The blood glucose concentration measured on the forearm was closer to the venous glucose than on the finger. The mean difference between $G_V$and $G_F$ was only 10 mg/dL well within the internationally accepted error limit. Error grid analyses of $G_F-G_V$, $G_A-G_V$ and $G_A-G_F$ revealed that the number of data points in regions A and B took 100%, 99.8%, and 97.9%, respectively. These results demonstrate the forearm blood glucose test is not only accurate but also clinically valid. Therefore, the forearm blood glucose test can be a useful way of self managing the chronic diabetes with minimized sampling pain.

Analysis of Relationship between Mixed Venous PO2 and Status of Cardiac Performance with Hemodynamic Values after Correction of Cyanotic Congenital Heart Disease (청색심기형 교정술후 혼합정맥혈 산소분압과 심근상태 및 혈류역학치와의 상관관계 분석)

  • An, Jae-Ho;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.212-219
    • /
    • 1989
  • We utilized pulmonary artery pressure monitoring system in risky patients for preventing the postoperative pulmonary hypertensive crisis and for sampling the mixed venous blood. And this mixed venous blood oxygen saturation [MVSO2] or partial pressure [MVPO2]tells us many meaningful patients state. We selected 59 cyanotic congenital heart diseased patients, who were operated in our hospital from Nov. 1987 to Oct. 1988, in the Department of Thoracic and Cardiovascular Surgery, Seoul National University Children\ulcorner Hospital, who had pulmonary artery pressure monitoring catheter and who made us know their mixed venous oxygen condition. We found that there was no close relationship between MVPO2 and Cardiac Index [C.I.] during early postoperative period, but on the first and second day after operation the correlation coefficient was increased as r=0.35[p=0.008], r=0.78[p=0.0001]. So we concluded that the correlation between MVPO2 and C.I. was more reliable with time going as hemodynamic stabilization. And we experienced no survivors whose MVPO2 was under 20 torr, but that was not the only factor for death. From these results, we conclude that we can consider the MVPO2 [or MVSO2] representing C.I. after stabilized postoperative condition of the open heart surgery patients, but during early postoperative period, in addition to this MVPO2, we should do also apply other parameter such as urine output, arterial blood pressure, left atrial pressure and pulmonary arterial pressure for exact estimation of the patients status.

  • PDF

Effects of Local Anesthetic Cream on Pain Relief in Newborns During Venipuncture (신생아의 정맥천자시 통증 완화를 위한 국소마취 크림 적용 효과)

  • Kim, Hae-Won;Ahn, Hye-Young
    • Child Health Nursing Research
    • /
    • v.17 no.4
    • /
    • pp.215-221
    • /
    • 2011
  • Purpose: Newborns routinely experience pain associated with invasive procedures such as blood sampling, venipuncture, heelstick, or venous cannulation. This study was done to provide data for a nursing intervention to alleviate newborn pain clinically by investigating the effect of local anesthetic cream during venipuncture. Methods: Participants were 70 newborns hospitalized in the nursery. Informed Consent was obtained from parents of the newborns. Venipuncture for regular blood sampling was carried out for a test on 2 groups; the experimental, placebo group. The neonatal infant pain scale (NIPS), and duration of crying were measured to assess pain reaction. All neonatal behaviors were recorded on videotape. Results: There were significant differences in pain behavior during venipuncture (t=-4.752, p<.001), immediately after sampling (t=-5.591, p<.001), 3 minutes after puncture (t=-2.469, p=.017), and in duration of crying (t=-3.005, p=.004). Conclusion: Results show that local administration of EMLA cream before venipuncture causes a reduction in neonatal pain response, indicating that the EMLA cream has the effect of pain relief.

Advances in the use of dried blood spots on filter paper to monitor kidney disease

  • Carla Nicola;Vandrea de Souza
    • Childhood Kidney Diseases
    • /
    • v.28 no.1
    • /
    • pp.16-26
    • /
    • 2024
  • Patients with kidney disease require frequent blood tests to monitor their kidney function, which is particularly difficult for young children and the elderly. For these people, the standard method is to evaluate serum creatinine or cystatin C or drug levels through venous sampling, but more recently, evaluation using dried blood spots has been used. This narrative review reports information from the literature on the use of dried blood spots to quantify the main markers used to detect kidney diseases. The ScienceDirect and PubMed databases were searched using the keywords: "dried blood on filter paper," "markers of renal function," "renal function," "creatinine," "cystatin C," "urea," "iohexol," and "iotalamate." Studies using animal samples were excluded, and only relevant articles in English or Spanish were considered. Creatinine was the most assessed biomarker in studies using dried blood spots to monitor kidney function, showing good performance in samples whose hematocrit levels were within normal reference values. According to the included studies, dried blood spots are a practical monitoring alternative for kidney disease. Validation parameters, such as sample and card type, volume, storage, internal patterns, and the effects of hematocrit are crucial to improving the reliability of these results.

Hematocrit Determination using a Volumetric Absorptive Microsampling Technique in Patients with Pancreatic Cancer

  • Yeolmae Jung;Seunghyun Yoo;Minseo Kang;Hayun Lim;Myeong Hwan Lee;Ji Kon Ryu;Jangik Lee
    • Korean Journal of Clinical Pharmacy
    • /
    • v.33 no.3
    • /
    • pp.195-201
    • /
    • 2023
  • Background: Hematocrit is usually measured from venous blood collected by invasive venipuncture. This study was performed to determine hematocrit accurately and precisely using minimally invasive volumetric absorptive microsampling (VAMS) technique. Such technique is to be applied to determining hematocrit in various clinical settings for the care, including therapeutic drug monitoring, of neonatal or epileptic patients, or patients with high risk of infection or bleeding. Methods: The study was performed using 31 VAMS samples obtained from 21 pancreatic cancer patients. Hematocrit was determined using the values of potassium concentrations obtained from blood in VAMS tips (HctVAMS). HctVAMS was compared with hematocrit measured from blood collected by venipuncture (HctVP). The accuracy and precision of HctVAMS in comparison to HctVP were evaluated using Bland-Altman plot, Deming regression and mountain plot. Results: Bland-Altman plot displayed a random scattering pattern of the differences between HctVAMS and HctVP with the mean bias of -0.010 and the 95% limit of agreement ranging from -0.063 to 0.044. Deming regression for HctVAMS and HctVP line demonstrated very small proportional and constant biases of 1.04 and -0.003, respectively. Mountain plot exhibited a narrow and symmetrical distribution of the differences with their median of -0.011 and central 95% range from -0.049 to 0.033. Conclusion: Hematocrit was accurately and precisely determined using less invasive VAMS technique. Such technique appears to be applicable to determining hematocrit in situations that venipuncture is not favorable or possible.

Anatomical Variations Encountered during Adrenal Venous Sampling: A Report of Three Case Series and Review of Literature (부신정맥채혈술 중 발견된 해부학적 변이들: 3건의 증례 보고 및 문헌 고찰)

  • Juyoung Pak;Hyoung Nam Lee;Myung Sub Kim;Hyerim Park
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.456-462
    • /
    • 2024
  • Primary aldosteronism is a group of disorders in which the autonomous secretion of aldosterone is associated with hypertension and hypokalemia. It is crucial to determine the laterality of aldosterone hypersecretion because treatment options differ accordingly. Adrenal venous sampling (AVS) is considered the most reliable method for assessing the laterality of primary aldosteronism. This procedure is often technically challenging because of the small size and varied locations of the adrenal veins. A better understanding of anatomical variations and careful review of imaging studies would improve sampling success. This report presents three cases of anatomical variations encountered during AVS.

Actual and Perceived Glove Uses Among Nurses in Intensive Care Unit (중환자실 간호사의 실제 장갑 사용과 인지하는 장갑 사용)

  • Ahn, Bo Ra;Kim, Eun Jung
    • Journal of East-West Nursing Research
    • /
    • v.28 no.2
    • /
    • pp.132-141
    • /
    • 2022
  • Purpose: This study aimed to investigate intensive care unit (ICU) nurses' actual and perceived glove uses for preventing healthcare associated infection. Methods: We observed nurses' donning glove by occasions and adherence to guideline for glove uses in four ICU in a single hospital. Total of 378 cases were observed from August 16 through October 6, 2020. Sixty one nurses of 66 nurses observed responded to a self-reported questionnaire about perceived glove use and knowledge of glove use. Data analysis was performed using descriptive statistics. Results: The number of observed episodes for glove use was 277. Although the highest numbers of occasions of wearing gloves was contact precaution, the compliance rate was 72.1%. The rates of donning gloves were low in the insertion and removal of peripheral venous catheters, blood glucose testing and blood sampling, which were at risk for exposure to blood. We observed misuse of wearing gloves even when they were not required. Results showed that the majority of non-compliance with glove use were a failure of performing hand hygiene before and after glove use and a failure of changing gloves between procedures on the same patient. The participant's knowledge of glove use was high. Conclusion: Based on the results, it is necessary to provide ICU nurses with education and reinforcement of proper glove uses for infection control.

Relationship Among Dietary Intake, Blood Level, and Urinary Excretion of Minerals and Blood Pressure in Korean Rural Adult Men and Women (농촌 성인 남녀의 무기질 섭취량, 혈액수준 및 소변중 배설량과 혈압과의 관계에 대한 연구)

  • 승정자
    • Journal of Nutrition and Health
    • /
    • v.26 no.1
    • /
    • pp.89-97
    • /
    • 1993
  • This study was carried out to estimate the relationship between dietary intake, blood level, and urinary excretion of minerals and blood pressure in 30 healthy adults living in rural area of Korea(12 males and 18 females). Analysis for the nutritional status of the subjects were performed by 3-day dietary intake record, duplicated diet collection, 24-hour urine collection, and venous blood sampling before measuring blood pressure. The mean blood pressure of subjects was 117.50/80.83mmHg in males and 110.00/73.89mmHg in females. The mean daily intakes of Na, K, Ca, P, Mg, Fe, Cu, Zn estimated for 3 days were 199.97mEq, 49.56mEq, 452.50mg, 725.57mg, 240.40mg, 12.48mg, 3.41mg, 8.28mg, respectively. The serum concentration of Na, K, Ca, P, Mg, Fe, Cu, Zn were 139.83mEq/dl, 4.06mEq/dl, 8.86mg/dl, 3.28mg/dl, 2.13mg/dl, 0.12mg/dl, 0.12mg/dl, 0.14mg/dl, respectively. The 24-hour urinary excretions of Na, K, Ca, p, Mg, Fe, Cu, Zn estimated for 169.60mEq, 39.37mEq, 80.40mg, 398.97mg, 64.77mg, 0.21mg, 0.07mg, 0.29mg, respectively. No significant correlation was found between dietary intake, serum concentration, and urinary excretion of minerals and blood pressure. But, the serum Ca/Mg ratio showed negative correlation with the systolic and diastolic blood pressure at the level of significance of 5%. The study verifies the need for more systematic studies on interrelationship among minerals and mineral requirements in normotensive and hypertensive subjects.

  • PDF