• Title/Summary/Keyword: velocity measurement

Search Result 2,149, Processing Time 0.033 seconds

Development and Feasibility Study for Phase Contrast MR Angiography at Low Tesla Open-MRI System (저자장 자기공명영상 시스템에서의 위상대조도 혈관조영기법의 개발과 그 유용성에 대한 연구)

  • Lee, Dong-Hoon;Hong, Cheol-Pyo;Lee, Man-Woo;Han, Bong-Soo
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.177-187
    • /
    • 2012
  • Magnetic resonance angiography (MRA) techniques are widely used in diagnosis of vascular disorders such as hemadostenosis and aneurism. Especially, phase contrast (PC) MRA technique, which is a typical non contrast-enhanced MRA technique, provides not only the anatomy of blood vessels but also flow velocity. In this study, we developed the 2- and 3-dimensional PC MRA pulse sequences for a low magnetic field MRI system. Vessel images were acquired using 2D and 3D PC MRA and the velocities of the blood flow were measured in the superior sagittal sinus, straight sinus and the confluence of the two. The 2D PC MRA provided the good quality of vascular images for large vessels but the poor quality for small ones. Although 3D PC MRA gave more improved visualization of small vessels than 2D PC MRA, the image quality was not enough to be used for diagnosis of the small vessels due to the low SNR and field homogeneity of the low field MRI system. The measured blood velocities were $25.46{\pm}0.73cm/sec$, $24.02{\pm}0.34cm/sec$ and $26.15{\pm}1.50cm/sec$ in the superior sagittal sinus, straight sinus and the confluence of the two, respectively, which showed good agreement with the previous experimental values. Thus, the developed PC MRA technique for low field MRI system is expected to provide the useful velocity information to diagnose the large brain vessels.

Assessment of Left Ventricular Function with Echocardiography in Patients Treated with Adriamycin : A Load-Independent Index of Myocardial Contractility and Comparisons between Rest and Exercise (Adriamycin을 사용한 환아에서 심초음파를 이용한 좌심실 기능의 평가 : 심근 수축력의 부하 비의존족 지표 및 휴식시와 운동시의 비교)

  • Park, Pyoung Soo;Park, Hye Young;Lee, Hae Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.214-222
    • /
    • 2002
  • Purpose : The aim of this study was to evaluate myocardial injury in children treated with adriamycin by echocardiography, which is non-invasive and safe measurement for children. Methods : Left ventricular dimensions, wall stress, and contractile function were determined by echocardiographic methods in 17 patient recepients with adriamycin chemotherapy at rest(group 1) and during stress(group 2). Twenty age-matched normal subjects were established as control group. Results : End-diastolic dimension was decreased in both groups(group 1; $92{\pm}7%$ of normal, group 2; $87{\pm}8%$ of normal, P<0.05). Left ventricular end diastolic volume and wall mass were also decreased in both groups(group 1; $96{\pm}12mL/m^2$ and $145{\pm}18g/m^2$, group 2; $87{\pm}8mL/m^2$ and $137{\pm}16g/m^2$, respectively, P<0.05 and P<0.05) and group 2 showed lower values than group 1. Meridional end systolic stress(ESSm) was increased in both groups but there was no significant difference between the two groups(group 1; $52.6{\pm}6.2g/cm^2$, group 2; $63.5{\pm}8.5g/cm^2$, P<0.05, normal value $45.7{\pm}3.5g/cm^2$). The load-independent relation of rate-corrected circumferential fiber shortening velocity(Vcfc) to ESSm has a significant abnormal change in 7 out of 17(41%) in group 1 and 12 out of 17(71%) in group 2. Conclusion : The load-dependent systolic index, such as fractional shortening, may fail to show abnormality because of the compensatory changes in preload and afterload which can mask the impaired contractility. Therefore, systolic performance also should be monitored by a load-indepedent contractility index such as slope value of the end-systolic pressure-dimension relation and the position of the left ventricular stress-fiber shortening velocity after exercise.

Diastolic Function in Patients with Hypertrophic Cardiomyopathy: Evaluation Using the Phase-contrast MRI Measurement of Mitral Valve and Pulmonary Vein Flow Velocities (비대성심근증 환자의 이완기능평가: 승모판과 폐정맥 유속을 측정한 위상차 MRI의 이용)

  • Kim, Eun Young;Choe, Yeon Hyeon;Kim, Sung Mok;Lee, Sang-Chol;Chang, Sung-A;Oh, Jae K.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.314-322
    • /
    • 2014
  • Purpose: Diastolic dysfunction is a common problem in patients with hypertrophic cardiomyopathy (HCM). The purpose of this study was to assess the role of MRI in the assessment of diastolic function using mitral valve and pulmonary vein flow velocities in HCM patients. Methods and Results: Phase-contrast MRI (mitral valve and pulmonary vein) and transthoracic echocardiography was successfully performed for 59 HCM patients (44 men and 15 women; mean age, 51 years). Forty-nine patients had a diastolic dysfunction; grade 1 (n = 20), grade 2 (n = 27), and grade 3 (n = 2) using echocardiography, and ten patients had normal diastolic function. The transmitral inflow parameters (E, A, and E/A ratios) obtained by MRI showed positive correlation with the same parameters measured by echocardiography (Pearson's r values were 0.47, 0.60, and 0.75 for E, A, E/A, respectively, all P < 0.001). With the flow information of the pulmonary vein from cardiac MRI, pseudo-normalized pattern (n = 8) could be distinguished from true normal filling pattern (n = 17), and the diastolic function grades by cardiac MRI showed moderate agreement with those of echocardiography (kappa value = 0.45, P < 0.001). Conclusions: Assessment of left ventricle diastolic function is feasible using phase-contrast MRI in HCM patients. Analysis of pulmonary vein flow velocity on MRI is useful for differentiating pseudo-normal from normal diastolic function in HCM patients.

Comparison of Weighted Needle Pinprick Sensory Thresholds and Sensory Nerve Conduction Studies in Diabetic Patients (당뇨병 환자에서의 가중침자 감각역치와 감각신경 전도검사와의 비교)

  • Ryoo, Jae-Kwan
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.1
    • /
    • pp.929-941
    • /
    • 1996
  • This study was conducted to determine the association between weighted needle pinprick sensory threshold(PPT) and sensory nerve conduction studies. The subjects were 53 healthy controls, 31 diabetic patients without peripheral neuropathic symptoms(DM) and 36 diabetic patients with peripheral neuropathic symptoms(DN). PPT was measured on the index and little fingers, bilaterally, as well as under the lateral malleolus, bilaterally. In electrophysiologic assessment the left and right median, ulnar and sural nerves were studied. Mean PPT in DN, DM and controls was high in turn on each sites tested. Age controlled PPT was significantly different among three groups on right little finger(p<0.05) and left malleolus(p<0.05), but on other sites, not statistically significantly different between DN and DM. The results were as follows: Sensory nerve conduction velocity and amplitude on each nerve tested were statistically significantly different among three groups(p<0.05). Correlation of PPT with sensory nerve conduction velocity and amplitude were statistically significant on each site and ranged from -0.4203(left malleolus) to -0.5649(right index finger) and from -0.3897(left index finger) to -0.6200(right index finger), respectively. When electrophysiological study is not feasible, measurement of PPT may be helpful for the assessment of peripheral sensory neurological function.

  • PDF

Geophysical and Geological Investigation for Selecting a Dinosaur Museum Site in the Dinosaur Egg Fossil Area, Gojeong-ri, Hwasung, Gyeonggi Province (경기도 화성 고정리 공룡알 화석지 공룡생태박물관 부지선정을 위한 지구물리 및 지질조사)

  • Kim, Han-Joon;Jeong, Gap-Sik;Yi, Bo-Yeon;Jo, Churl-Hyun;Lee, Kwang-Bae;Lee, Jun-Ho;Jou, Hyeong-Tae;Lee, Gwang-Hoon
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.357-363
    • /
    • 2010
  • In this study, we investigated the geologic structure of the basement and overlying sediments of the construction site of the dinosaur egg fossil museum in Hwasung, Gyeonggi Province through refraction seismology, drilling, and downward seismic velocity measurements in the drill holes. The construction site ($350{\times}750\;m^2$) is located in the reclaimed area south of Sihwa Lake, Gojeong-ri. About 6,950 m of seismic refraction data consisting of 11 lines were acquired using a sledge hammer source. Drilling to the basement was performed at five sites. Sediment samples from drilling were analysed for grain-size distribution and age dating. At two drill holes, seismic velocity was measured with depth using a hammer as a seismic source. The geological structure of the study area consists of, from top to bottom, a tidal flat layer (5 ~ 12 m thick), a weathered soil layer (2 ~ 8 m thick), and the basement. The basement is interpreted as Cretaceous sedimentary rocks that tend to be shallow eastward. The volume of the tidal flat sediments and weathered soil in the study area is estimated as $1.4{\times}10^6\;m^3$, weighing $3.5{\times}10^6$ tons. The rate of sea level rise since 8,000 yrs BP is estimated to be 0.1 ~ 0.15 cm/yr.

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.

Comparison of Weighted Needle Pinprick Sensory Thresholds and Sensory Nerve Conduction Studies in Diabetic Patients (당뇨병(糖尿病) 환자(患者)에서의 가중침자(加重針刺) 감각역치와 감각신경(感覺神經) 전도검사(傳導檢査)와의 비교(比較))

  • Yoo, Jae-Kwan;Kim, Seong-Ah;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.899-910
    • /
    • 1995
  • This study was conducted to determine the correlation between weighted needle pinprick sensory threshold(PPT) and sensory nerve conduction tests. The subjects were 53 healthy controls, 31 diabetic patients without peripheral neuropathic symptoms(DM) and 36 diabetic patients with peripheral neuropathic symptoms(DN). PPT was measured on the index and little fingers, bilaterally, as well as under the lateral malleolus, bilaterally. In electrophysiologic assessment the left and right median, ulnar and sural nerves were studied. Each mean PPTs was high in order of controls, DM and DN. Age adjusted PPT was significantly different among three groups on right little finger(p<0.05) and left malleolus(p<0.05), but not significantly different between DN and DM on other sites. Each sensory nerve conduction velocity and amplitude was statistically significantly different among three groups(p<0.05). Correlations of PPT with sensory nerve conduction velocity and amplitude were statistically significant on each site and ranged from -0.4203(left malleolus) to -0.5649(right index finger) and from -0.3897(left index finger) to -0.6200(right index finger), respectively. When electrophysiological study is not feasible, measurement of PPT may be helpful for the assessment of peripheral sensory neurological function.

  • PDF

A Proposal for Simplified Velocity Estimation for Practical Applicability (실무 적용성이 용이한 간편 유속 산정식 제안)

  • Tai-Ho Choo;Jong-Cheol Seo; Hyeon-Gu Choi;Kun-Hak Chun
    • Journal of Wetlands Research
    • /
    • v.25 no.2
    • /
    • pp.75-82
    • /
    • 2023
  • Data for measuring the flow rate of streams are used as important basic data for the development and maintenance of water resources, and many experts are conducting research to make more accurate measurements. Especially, in Korea, monsoon rains and heavy rains are concentrated in summer due to the nature of the climate, so floods occur frequently. Therefore, it is necessary to measure the flow rate most accurately during a flood to predict and prevent flooding. Thus, the U.S. Geological Survey (USGS) introduces 1, 2, 3 point method using a flow meter as one way to measure the average flow rate. However, it is difficult to calculate the average flow rate with the existing 1, 2, 3 point method alone.This paper proposes a new 1, 2, 3 point method formula, which is more accurate, utilizing one probabilistic entropy concept. This is considered to be a highly empirical study that can supplement the limitations of existing measurement methods. Data and Flume data were used in the number of holesman to demonstrate the utility of the proposed formula. As a result of the analysis, in the case of Flume Data, the existing USGS 1 point method compared to the measured value was 7.6% on average, 8.6% on the 2 point method, and 8.1% on the 3 point method. In the case of Coleman Data, the 1 point method showed an average error rate of 5%, the 2 point method 5.6% and the 3 point method 5.3%. On the other hand, the proposed formula using the concept of entropy reduced the error rate by about 60% compared to the existing method, with the Flume Data averaging 4.7% for the 1 point method, 5.7% for the 2 point method, and 5.2% for the 3 point method. In addition, Coleman Data showed an average error of 2.5% in the 1 point method, 3.1% in the 2 point method, and 2.8% in the 3 point method, reducing the error rate by about 50% compared to the existing method.This study can calculate the average flow rate more accurately than the existing 1, 2, 3 point method, which can be useful in many ways, including future river disaster management, design and administration.

The Development of a Benthic Chamber (BelcI) for Benthic Boundary Layer Studies (저층 경계면 연구용 Benthic chamber(BelcI) 개발)

  • Lee, Jae-Seong;Bahk, Kyung-Soo;Khang, Buem-Joo;Kim, Young-Tae;Bae, Jae-Hyun;Kim, Seong-Soo;Park, Jung-Jun;Choi, Ok-In
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.15 no.1
    • /
    • pp.41-50
    • /
    • 2010
  • We have developed an in-situ benthic chamber (BelcI) for use in coastal studies that can be deployed from a small boat. It is expected that BelcI will be useful in studying the benthic boundary layer because of its flexibility. BelcI is divided into three main areas: 1) frame and body chamber, 2) water sampler, and 3) stirring devices, electric controller, and data acquisition technology. To maximize in-situ use, the frame is constructed from two layers that consist of square cells. All electronic parts (motor controller, pA meter, data acquisition, etc.) are low-power consumers so that the external power supply can be safely removed from the system. The hydrodynamics of BelcI, measured by PIV (particle image velocimetry), show a typical "radial-flow impeller" pattern. Mixing time of water in the chamber is about 30 s, and shear velocity ($u^*$) near the bottom layer was calculated at $0.32\;cm\;s^{-1}$. Measurements of diffusivity boundary layer thickness showed a range of $180-230\;{\mu}m$. Sediment oxygen consumption rate, measured in-situ,was $84\;mmol\;O_2\;m^{-2}\;d_{-1}$, more than two times higher than on-board incubation results. Benthic fluxes assessed from in-situ incubation were estimated as follows: nitrate + nitrite = $0.18\;{\pm}\;0.07\;mmol\;m^{-2}\;d^{-1}$ ammonium $23\;{\pm}\;1\;mmol\;m^{-2}\;d^{-1}$ phosphate = $0.09\;{\pm}\;0.02\;mmol\;m^{-2}\;d^{-1}$ and silicate = $23\;{\pm}\;1\;mmol\;m^{-2}\;d^{-1}$.

Kinematic Effects of Newly Designed Knee-Ankle-Foot Orthosis With Oil Damper Unit on Gait in People With Hemiparesis

  • Park, Hyung-Ki;Kim, Tack-Hoon;Choi, Houng-Sik;Roh, Jung-Suk;Cynn, Heon-Seock;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.64-73
    • /
    • 2013
  • The purposes of this study were to develop a new orthosis controlling ankle and knee joint motion during the gait cycle and to identify the effects of the newly designed orthosis on gait kinematics and tempospatial parameters, including coordination of the extremities in stroke patients. Fifteen individuals who had sustained a stroke, onset was 16 months, participated in this study. Before application of the measurement equipment the subjects were accustomed to walking on the ankle-foot orthosis (AFO) or stance control knee with knee flexion assisted-oil damper ankle-foot orthosis (SCKAFO) for 5 minutes. Fifteen patients were investigated for 45 days with a 3-day interval between sessions. Measurements were walking in fifteen stroke with hemiparesis on the 3D motion analysis system. Comparison of AFO and SCKAFO are gait pattern. The difference between the AFO and SCKAFO conditions was significant in the gait velocity, step length of the right affected side, stance time of both legs, step-length asymmetry ratio, single-support-time asymmetry ratio, ${\phi}$-thigh angle and ${\phi}$-shank angle in the mid swing (p<.001). Using a SCKAFO in stroke patients has shown similar to normal walking speeds can be attained for walking efficiency and is therefore desirable. In this study, the support time of the affected leg with the SCKAFO was longer than with the AFO and the asymmetry ratio of single support time decreased by more than with the AFO. This indicates that the SCKAFO was effective for improving gait symmetry, single-support-time symmetry. This may be due to the decrease of gait asymmetry. Thus, the newly designed SCKAFO may be useful for promoting gait performance by improving the coordination of the extremity and decreasing gait asymmetry in chronic stroke patients.