• Title/Summary/Keyword: velocity

Search Result 23,138, Processing Time 0.045 seconds

Red Blood Cell Velocity Field in Rat Mesenteric Arterioles Using Micro PIV Technique

  • Sugii, Y;Nishio, S;Okamoto, K;Nakano, A;Minamiyama, M;Niimi, H
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.24-31
    • /
    • 2003
  • As endothelial cells are subject to flow shear stress, it is important to determine the detailed velocity distribution in microvessels in the study of mechanical interactions between blood and endothelium. This paper describes a velocity field of the arteriole in the rat mesentery using an intravital microscope and high-speed digital video system obtained by a highly accurate PIV technique. Red blood cells (RBCs) velocity distributions with spatial resolutions of $0.8{\times}0.8{\mu}m$ were obtained even near the wall in the center plane of the arteriole. By making ensemble-averaged time-series of velocity distributions, velocity profiles over different cross-sections were calculated for comparison. The shear rate at the vascular wall also evaluated on the basis of the ensemble-averaged profiles. It was shown that the velocity profiles were blunt in the center region of the vessel cross-section while they were steep in the near wall region. The wall shear rates were significantly small, compared with those estimated from the Poiseuille profiles.

  • PDF

An Accurate Velocity Estimation using Low Resolution Tachometer of High-Speed Trains (고속열차의 저해상도 타코미터를 이용한 정확한 속도 추정에 관한 연구)

  • Lee, Jae-Ho;Kim, Seong Jin;Park, Sungsoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.131-136
    • /
    • 2018
  • Reliable velocity estimation technology for trains is one of technologies used to operate trains safely and effectively. Various sensors such as tachometers, doppler radars, and global positioning systems are used to estimate velocity of a train. Tachometer is widely used to estimate velocity of a trains due to its simplicity, small volume, cost-effectiveness, continuously measurement at high speed, and robustness against noise. Accuracy in the velocity calculation using a tachometer depends on quantization error, measurement error of wheel radius or diameter, and tachometer's imperfection from manufacturing or installation process. In this paper, we present an accurate velocity estimation method using a low-resolution tachometer, which is commonly installed on a high-speed train. Baseline estimation method is proposed to accurately calculate the velocity of the high-speed train from tachometer's pulses. HEMU-430x test train is used for the experiment and verification of the proposed method. Experimental results with several routes show that the proposed method is more accurate than a conventional method.

Penetration resistance of steel fiber reinforced concrete containment structure to high velocity projectile

  • Teng, Tso-Liang;Chu, Yi-An;Shen, Bor-Cherng
    • Computers and Concrete
    • /
    • v.5 no.6
    • /
    • pp.509-524
    • /
    • 2008
  • Containment structures not only are leak-tight barriers, but also may be subjected to impacts caused by tornado-generated projectiles, aircraft crashes or the fragments of missile warhead. This paper presents the results of an experimental study of the impact resistance of steel fiber-reinforced concrete against 45 g projectiles at velocity around 2500 m/s. An explosively formed projectile (EFP) was designed to generate an equivalent missile fragment. The formation and velocity of EFP are measured by flash x-ray. A switch made of double-layered thin copper sheets controlled the exposure time of each flash x-ray. The influence of the fiber volume fraction on the crater diameter of concrete slab and the residual velocity of the projectile were studied. The residual velocity of the projectile decreased as the fiber volume fractions increased. In this work, the residual velocity of the projectile was to 44% that of plain concrete when the fiber volume fraction exceeded 1.5%. Based on the present finding, steel fiber reinforced concrete with the fiber volume fraction exceeding 1.5% appear to be more efficient in protection against high velocity fragment impact.

A Study on the Maximum Velocity and the Surface Velocity (최대유속과 표면유속에 관한 연구)

  • Choo, Tai Ho;Je, Sung Jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.05a
    • /
    • pp.351-355
    • /
    • 2006
  • The purpose of this study is to develop an efficient and useful equation of discharge measurement which can calculate easily discharge using only the surface velocity in both channels and rivers. The research results show: (1) Natural river have a propensity to establish and maintain an equilibrium state the corresponds to a value of the entropy parameter M; (2) Velocity distribution estimated by the method using surface velocity was compared with that of actual survey. It shows fairly close agreements between the estimated and the observed; (3) Developed equations for calculating the discharge using the surface velocity at the spot of the maximum velocity in a river section were established and show that the method of using fairly acceptable. An entropy based method for determining the discharge using only surface velocity in the rivers has been developed. The method presented is also efficient and applicable in estimating the discharge in high flows during the flood season that are very difficult or impossible to measure before, due to technical or theoretical reasons.

  • PDF

Effect of NOx Removal Efficiency according to Space Velocity and Linear Velocity of SCR Catalyst (SCR 촉매의 공간속도 및 선속도가 NOx 제거 효율에 미치는 영향)

  • Park, Jin-woo;Park, Sam-sik;Ku, Kun Woo;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.21 no.2
    • /
    • pp.71-77
    • /
    • 2016
  • Air pollutants nitrogen oxides are inevitably generated in the combustion reaction. Its amount trend is steadily increasing because the rapid modern industrialization and population growth. For this reason, NOx is controlled to reducing the harmful components in the exhaust gas. So Marine Environment Protection Committee (MEPC) take effect 'Tier I', 'Tier II' of air pollution regulation in 2005 and 2011 respectively. According to NOx emissions are strictly regulated management of the vessel through them. In addition, since 2016 the regulation enter into force in the next step 'Tier III' was confirmed by MEPC 66th committee. It's 80% enhanced emissions limits than the 'Tier I' Alternatively these emission regulation, research is actively being carried out about exhaust gas after-treatment methods through the vessel application of Selective Catalytic Reduction(SCR). Therefore depending on the basic specification of cell density according to the Area velocity, Space velocity, Linear velocity is studied the effects of NOx removal efficiency

Stable Zero-Velocity Detection Method Regardless of Walking Speed for Foot-Mounted PDR

  • Cho, Seong Yun;Lee, Jae Hong;Park, Chan Gook
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.1
    • /
    • pp.33-42
    • /
    • 2020
  • In Integration Approach (IA)-based Pedestrian Dead Reckoning (PDR), it is important to detect the exact zero-velocity of the foot with an Inertial Measurement Unit (IMU). By detecting zero-velocity during the stance phase of the foot touching the ground and executing Zero-velocity UPdaTe (ZUPT) at the exact time, stable navigation information can be provided by the PDR. When the pace is fast, however, it is not easy to accurately detect the zero-velocity because of the small stance phase interval and the large signal variance of the corresponding interval. Incorrect zero-velcity detection greatly causes navigation errors of IA-based PDR. In this paper, we propose a method to detect the zero-velocity stably even at high speed by novel buffering of IMU's output data and signal processing of the buffer. And we design a PDR based on this. By analyzing the performance of the proposed Zero-Velocity Detection (ZVD) algorithm and ZVD-based PDR through experiemnts, we confirm that the proposed method can provide accurate navigation information of pedestrians such as firefighters in the indoor space.

Effect of Water Velocity on Foraging Behavior of Planktivore on Zooplankton in Aquatic Ecosystems (유속조건에 따른 수중 생태계내 소형어류의 동물플랑크톤 포식 행동 변화에 관한 연구)

  • Park, Bae Kyung;Park, Seok Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.79-83
    • /
    • 2005
  • Foraging behaviour of false dace, Pseudorasbora parva, was investigated in water flowing at various velocities with the existence of a cavity for rest. The pursuit comprised three succeeding processes such as, approaching, chasing and attacking. Angles between the fish body and the water flow direction and swimming speeds increased in the latter stages of approaching, chasing and attacking. All pursuit angles, swimming speeds and distances increased with flow velocity and peaked at the flow velocity of 7 cm/sec. At higher velocities, however, the fish avoided the use of much energy against the large drag force. The probability of capture and the feeding rate steadily decreased with increasing flow velocity. Under the fast flow, the fish adjusted their swimming speed to get the optimum velocity relative to the flowing water for the energetic budget. Fish spent more time in the cavity as flow velocity increased to avoid the energy expenditure necessitated by the high velocity.

Velocity and Temperature Profiles of Steam-Air Mixture on the Film Condensation (막응축 열전달에서 공기-수증기 혼합기체의 속도 및 온도분포)

  • 강희찬;김무환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2675-2685
    • /
    • 1994
  • A study has been conducted to provide the experimental information for the velocity and temperature profiles of steam-air mixutre and to investigate their roles on the film condensation with wavy interface. Saturated gas mixture of steam-air was made to flow through the nearly horizontal$(4.1^{\circ})$ square duct of 0.1m width and 1.56m length at atmospheric pressure, and was condensated on the bottom cold plate. The air mass fraction in the gas mixture was changed from zero(W =0, pure steam) to one(W =1, pure air), and the bulk velocity was varied from 2 to 4 m/s. Water film was injected concurrently to investigate the effect of wavy interface on the condensation. The velocity and temperature profiles were measured by LDA system and thermocouples along the three parameters ; air mass fraction, mixture velocity and film flow rate. The profiles moved toward the interface with increasing steam mass fraction, mixture velocity and film flow rate. The Prandtl and Schmidt numbers were near one in the present experimental range, however there was no complete similarity between the velocity and temperature profiles of gas mixture. And the heat transfer characteristics and interfacial structure were coupled with each other.

Axial Direction Velocity and Secondary Flow Distributions of Turbulent Pulsating Flow in a Curved Duct (곡관덕트에서 난류맥동유동의 축방향 속도분포와 2차유동속도분포)

  • 손현철;이홍구;이행남;박길문
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.15-23
    • /
    • 2000
  • In the present study, flow characteristics of turbulent pulsating flow in the square-sectional $180^{\circ}$curved duct are investigated experimentally. In order to measure axial direction velocity and secondary flow distributions, experimental studies for air flow are conducted in the square-sectional $180^{\circ}$curved duct by using the LDV system with the data acquisition and the processing system of the Rotating Machinery Resolver (RMR) and the PHASE software. The experiment is conducted on seven sections form the inlet($\phi=0^{\circ}$) to the outlet($\phi=180^{\circ}$) at $30^{\circ}$intervals of the duct. The results obtained from the experimentation are summarized as follows : In the axial direction velocity distributions of turbulent pulsating flow, when the ratio of velocity amplitude (A1) is less than one, there is hardly any velocity change in the section except near the wall and in axial velocity distribution along the phase. The secondary flow of turbulent pulsating flow has a positive value at the bend angle of $150^{\circ}$regardless of the ratio of velocity amplitude. The dimensionless value of secondary flow becomes gradually weak and approaches zero in the region of bend angle $180^{\circ}$without regard to the ratio of velocity amplitude.

  • PDF

Compare Characteristics of Neck Injuries between Rear Impact Pulse and NCAP Pulse (후방 충돌 펄스와 NCAP 펄스 차이로 인한 목상해 특성 비교)

  • Kim, Jong Kon;Park, Jong Ho
    • Journal of Auto-vehicle Safety Association
    • /
    • v.9 no.3
    • /
    • pp.7-12
    • /
    • 2017
  • The whiplash is the most important issue of low speed rear-impact. So auto makers are committed to developing a seat to improve whiplash injury. Most NCAP tests have been used by same pulse (Mid Velocity 16kph). Only Euro NCAP uses different pulse that consists of Low, Mid, High velocity. But Euro NCAP also uses same pulse in Mid velocity as other NCAP test. That Mid velocity NCAP pulse was made by rear impact that has 90's vehicle structure properties. That pulse was used until now days. However these days, auto maker use more high tensile steel than 90's as customer and society demand more fuel efficiency and light vehicle with good safety structure. So modern vehicles have different pulse patterns of rear impact than NCAP pulse and 90's vehicle crash properties. In this paper, the test was conducted by following condition. Target car was impacted by the rigid barrier with certain velocity. Finally target vehicle gained delta V 16kph which was same velocity as NCAP Mid Velocity pulse. It is critical velocity which occur long period neck injury. It is very different pulse that was gained by real car impact from NCAP pulse. And it has higher peak G with high fluctuation and short duration than NCAP pulse.