• Title/Summary/Keyword: varying coefficients

Search Result 361, Processing Time 0.025 seconds

TWO-COLOR CCD PHOTOMETRY OF THE INTERMEDIATE POLAR 1RXS J180340.0+401214

  • Andronov, Ivan L.;Kim, Yong-Gi;Yoon, Joh-Na;Breus, Vitalii V.;Smecker-Hane, Tammy A.;Chinarova, Lidia L.;Han, Won-Yong
    • Journal of The Korean Astronomical Society
    • /
    • v.44 no.3
    • /
    • pp.89-96
    • /
    • 2011
  • We present results of two-color VR photometry of the intermediate polar RXS J1803. The data were aquired using the Korean 1-m telescope located at Mt. Lemmon, USA. Different "high" and "low" luminosity states, similar to other intermediate polars, were discovered. No statistically significant variability of the color index with varying luminosity was detected. The orbital variability was found to be not statistically significant. Spin maxima timings were determined, as well as the photometric ephemeris for the time interval of our observations. The spin period variations, caused by interaction of the accretion structure with the rotating magnetic white dwarf, were also detected. These variations are of complicated character, and their study requires further observations. We determine the color transformation coefficients for our photometric systems, and improve on the secondary photometric standards.

ANALYSIS OF HEAT TRANSFER PERFORMANCE WITH ASPECT AND FILLING RATIOS IN THERMOSYPHON (열사이펀의 형상비와 충전율에 따른 열전달 성능 해석)

  • Kim, Y.C.;Choi, J.W.;Kim, S.C.
    • Journal of computational fluids engineering
    • /
    • v.20 no.1
    • /
    • pp.92-98
    • /
    • 2015
  • Thermal-fluid analysis is performed numerically to figure out the characteristics of heat transfer in a thermosyphon varying with the aspect ratio of geometry and the filling ratio of working fluid. The computational results are reasonable compared with the experimental data and visualized. The thermal resistance and the convective heat transfer coefficients are evaluated with the aspect ratio of thermosyphon and the filling ratio of working fluid, respectively. In conclusion, the thermal resistance decreases as the length of evaporator increases. However, the variation of a condenser length is nearly independent on the thermal resistance. In order to raise the performance of thermosyphon, the working fluid needs to be filled over 75%. In addition, Nusselt numbers in the evaporator and the condenser show 275 and 304, respectively.

Compressional Properties of Fabrics at Low Pressure to Assess Real Fabric Handle (직물의 태 예측에 근접한 직물의 저응력 압축특성 측정)

  • Na, Young-Joo
    • Fashion & Textile Research Journal
    • /
    • v.1 no.4
    • /
    • pp.358-362
    • /
    • 1999
  • Twenty-three fabrics of varying thicknesses and weights were subjected to the maximum pressures of 10, 20, 35, 50 and 70 $gf/cm^2$ to yield pressure-thickness curves. Compression property values were plotted according to the amount of pressure applied to the samples. Pressure increases resulted in decreases in LC (compressional curve linearity), increases in WC (compressional energy) and no change in RC (compressional resilience). The best-fit lines are found separately according to pressures. The thickest fabrics exhibited the highest LC and WC values. The slopes varied different according to the pressure applied, with a pressure 50 $gf/cm^2$ exhibiting the steepest slope at We. The pressure of 20 $gf/cm^2$ correlated most closely with the hand-evaluation test results, yielding Spearmans correlation coefficients of .86 and .82 respectively for the LC and WC.

  • PDF

Bacterial Pattern Formation in Response to the Stiffness of Substrates (접촉 표면의 강성 변화에 따른 박테리아의 군집 패턴)

  • Kim, J.K.;Park, E.J.;Kim, S.R.;Cho, M.Y.;Han, H.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.88-91
    • /
    • 2007
  • Animal cells show different behaviors in response to the mechanical properties of the substrates. We hypothesize that the rigidity of the substrates also affects the bacterial motility and controls the colony dynamics. It is found that the colony size of Escherichia colis and Bacillus subtilis grown on the agar plates is correlated with agarose gel concentrations and thus with the substrate rigidity. High- resolution microscopic imaging reveals that bacteria in single colonies form different aggregation patterns on the agar plates with varying gel concentration. We measured the apparent diffusion coefficients in the agarose gel plates made with different gel concentrations. Mathematical modeling and quantitative imaging of dye dispersion in the agar plates suggest that there is a close connection between the diffusion rate and the colony size. Nanoscale pore structures and kinetic constraints in the porous media may have an effect on bacterial colony dynamics.

  • PDF

Decentralized Robust Adaptive Neural Network Control for Electrically Driven Robot Manipulators with Bounded Input Voltages (제한된 입력 전압을 갖는 전기 구동 로봇 매니퓰레이터에 대한 분산 강인 적응 신경망 제어)

  • Shin, Jin-Ho;Kim, Won-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.11
    • /
    • pp.753-763
    • /
    • 2015
  • This paper proposes a decentralized robust adaptive neural network control scheme using multiple radial basis function neural networks for electrically driven robot manipulators with bounded input voltages in the presence of uncertainties. The proposed controller considers both robot link dynamics and actuator dynamics. Practically, the controller gain coefficients applied at each joint may be nonlinear time-varying and the input voltage at each joint is saturated. The proposed robot controller overcomes the various uncertainties and the input voltage saturation problem. The proposed controller does not require any robot and actuator parameters. The adaptation laws of the proposed controller are derived by using the Lyapunov stability analysis and the stability of the closed-loop control system is guaranteed. The validity and robustness of the proposed control scheme are verified through simulation results.

Experimental Evaluation of Design Parameters for TLCD and LCVA (TLCD와 LCVA의 설계파라미터에 대한 실험적 평가)

  • Lee, Sung-Kyung;Min, Kyung-Won;Park, Ji-Hun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.5
    • /
    • pp.403-410
    • /
    • 2009
  • In this paper, damping coefficients and effective masses of tuned liquid-type column dampers were quantitatively evaluated based on experimental results by using system identification technique. First, shaking table tests were performed for two types of tuned liquid-type column dampers. Then, the dynamic characteristics of dampers used in this study were experimentally grasped from harmonic wave excitation testing results of the dampers with various water level. Finally, damping ratios and effective masses of the dampers with varying water level were quantitatively evaluated from minimizing the errors between numerical and experimental results. It was confirmed from system identification results that damping ratio and effective mass are decreased as the water level of dampers is increased.

Thermo-Mechanical Interaction of Flip Chip Package Constituents (플립칩 패키지 구성 요소의 열-기계적 특성 평가)

  • 박주혁;정재동
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.183-190
    • /
    • 2003
  • Major device failures such as die cracking, interfacial delamination and warpage in flip chip packages are due to excessive heat and thermal gradients- There have been significant researches toward understanding the thermal performance of electronic packages, but the majority of these studies do not take into account the combined effects of thermo-mechanical interactions of the different package constituents. This paper investigates the thermo-mechanical performance of flip chip package constituents based on the finite element method with thermo-mechanically coupled elements. Delaminations with different lengths between the silicon die and underfill resin interfaces were introduced to simulate the defects induced during the assembly processes. The temperature gradient fields and the corresponding stress distributions were analyzed and the results were compared with isothermal case. Parametric studies have been conducted with varying thermal conductivities of the package components, substrate board configurations. Compared with the uniform temperature distribution model, the model considering the temperature gradients provided more accurate stress profiles in the solder interconnections and underfill fillet. The packages with prescribed delaminations resulted in significant changes in stress in the solder. From the parametric study, the coefficients of thermal expansion and the package configurations played significant roles in determining the stress level over the entire package, although they showed little influence on stresses profile within the individual components. These observations have been implemented to the multi-board layer chip scale packages (CSP), and its results are discussed.

Aerodynamic Force Measurement of Counter-Rotating System (동축 반전 시스템의 공력측정)

  • Kim, Su-Yean;Choi, Jong-Wook;Kim, Sung-Cho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.39-42
    • /
    • 2008
  • In the case of the general helicopter among rotorcraft, length of the rotor blade for thrust-generation is longer than that of fuselage and tail rotor is required in order to compensate moment of the fuselage. For those reasons, enough space for take-off and landing should be secured and an accessibility for building is low. Also, the accidents caused by tail rotor occur frequently. However, the case of counter-rotating has merits that tail rotor is unnecessary as well as length of the rotor blade can be shortened but has a weakness that the weight of body is increased. In the present study, aerodynamic force measurement on single rotor system equipped with NACA0012 airfoil, which has aspect ratio of 6 and chord length of 35.5 mm, was carried out. And measurement was conducted with blade which has a half size of the former blade by using single motor counter-rotating. Aerodynamic force measurement was acquired by using 6-component balances and coefficients of thrust and power were derived along the pitch angle varying from 0$^{\circ}$ to 90$^{\circ}$ with the increment of 10$^{\circ}$. Those aerodynamic force data will be utilized for the design and production of brand-new counter-rotating rotor blade system which has same thrust with single blade system and provides a good accessibility to building by reducing its blade length.

  • PDF

Affecting Factors on the Variation of Atmospheric Concentration of Polycyclic Aromatic Hydrocarbons in Central London

  • Baek, Sung-Ok;Roger Perry
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.E
    • /
    • pp.343-356
    • /
    • 1994
  • In this study, a statistical investigation was carried out for the evaluation of any relationship between polycyclic aromatic hydrocarbons (PAHss) associated with ambient aerosols and other air quality parameters under varying meteorological conditions. Daily measurements for PAHs and air quality/meteorological parameters were selected from a data-base constructed by a comprehensive air monitoring in London during 1985-1987. Correlation coefficients were calculated to examine any significant relationship between the PAHs and other individual variables. Statistical analysis was further Performed for the air quality/meteorological data set using a principal component analysis to derive important factors inherent in the interactions among the variables. A total of six components were identified, representing vehicle emission, photochemical activity/volatilization, space heating, atmospheric humidity, atmospheric stability, and wet deposition. It was found from a stepwise multiple regression analysis that the vehicle emission component is overall the most important factor contributing to the variability of PAHs concentrations at the monitoring site. The photochemical activity/volatilzation component appeared to be also an important factor particularly for the lower molecular weight PAHs. In general, the space heating component was found to be next important factor, while the contributions of other three components to the variance of each PAHs did not appear to be as much important as the first three components in most cases. However, a consistency for these components in their negative correlations with PAHs data was found, indicating their roles in the depletion of PAHs concentrations in the urban atmosphere.

  • PDF

Comparison of Cushion Performance on Parameter Changes in High Speed Pneumatic Cylinder Driving System (공기압 실린더 고속 구동시스템에서 파라미터 변화에 따른 쿠션성능 비교)

  • Kim, Do Tae;Jang, Zhong Jie
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.54-59
    • /
    • 2015
  • Due to the tendency to use high speed pneumatic cylinders to improve productivity, cushioning devices are adopted to decelerate the piston motion of pneumatic cylinders to reduce noise, vibration, and impact. This paper presents a comparison of the cushion characteristics of a high speed pneumatic cylinder with a relief valve type cushioning device. The system parameters selected are the damping coefficient, Coulomb friction, heat transfer coefficient, and cracking pressure of the relief valve in the air cushioning device. The integral of the time multiplied square error (ITSE) is used to quantitative measure the cushioning performance to assess the effect of varying these. The cushioning performance achieved good results when the ITSE is a minimum value. In a comparison of the piston displacement and velocity with the variations in system parameters, the heat transfer coefficients are not as significantly affected as the other. Also, the cracking pressure of the relief valve is mainly affected by the pressure and temperature in the cushion chamber.