• Title/Summary/Keyword: varistor

Search Result 372, Processing Time 0.031 seconds

Sintering and Electrical Properties of Cr-doped ZnO-Bi2O3-Sb2O3 (Cr을 첨가한 ZnO-Bi2O3-Sb2O3계의 소결과 전기적 특성)

  • Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jin-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.12
    • /
    • pp.942-948
    • /
    • 2010
  • In this study we aims to examine the effects of 0.5 mol% $Cr_2O_3$ addition on the reaction, microstructure development, resultant electrical properties, and especially the bulk trap and interface state levels of ZnO-$Bi_2O_3-Sb_2O_3$ (Sb/Bi=0.5, 1.0, and 2.0) systems (ZBS). The samples were prepared by conventional ceramic process, and characterized by XRD, density, SEM, I-V, impedance and modulus spectroscopy (IS & MS) measurement. The sintering and electrical properties of Cr-doped ZBS (ZBSCr) systems were controlled by Sb/Bi ratio. Pyrochlore ($Zn_2Bi_3Sb_3O_{14}$) was decomposed more than $100^{\circ}C$ lowered on heating in ZBS (Sb/Bi=1.0) by Cr doping. The densification of ZBSCr (Sb/Bi=0.5) system was retarded to $800^{\circ}C$ by unknown Bi-rich phase produced at $700^{\circ}C$. Pyrochlore on cooling was reproduced in all systems. And $Zn_7Sb_2O_{12}$ spinel ($\alpha$-polymorph) and $\delta-Bi_2O_3$ phase were formed by Cr doping. In ZBSCr, the varistor characteristics were not improved drastically (non-linear coefficient $\alpha$ = 7~12) and independent on microstructure according to Sb/Bi ratio. Doping of $Cr_2O_3$ to ZBS seemed to form $Zn_i^{..}$(0.16 eV) and $V^{\bullet}_o$ (0.33 eV) as dominant defects. From IS & MS, especially the grain boundaries of Sb/Bi=0.5 systems were divided into two types, i.e. sensitive to oxygen and thus electrically active one (1.1 eV) and electrically inactive intergranular one (0.95 eV) with temperature.

Dead Operation Characteristics of Earth Leakage Circuit Breaker for 50[A] Against Surge Voltages (서지전압에 대한 50[A]용 누전차단기의 부동작 특성)

  • 이승칠;장석훈;이복희
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.44-52
    • /
    • 1997
  • Electronic circuits with semiconductor and IC are very weak against the surge voltage and currents. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of the earth leakage circuit breaker(ELB) due to the operation of surge protective devices, and the interruption of AC power lines on account of the malfunction of the ELB brings about several disadvantages such as low operation efficiency and reliability of electronic and informational systems, economical loss, and etc. The aim of the present work is to investigate the dead operation characteristics of the ELB against the surge voltages. The impulse generator of 10[kV) in an 1.2/ 50[~) voltage waveform was fabricated. The dead operation characteristics of the ELB applied by surge voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a consequence, the peak value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not bring about dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELB installed at the AC power lines with the surge protective devices bring about the dead operation.

  • PDF

Electrical and Dielectric Properties of Zn-Pr-Co-Cr-Dy Oxides-based Varistors (Zn-Pr-Co-Cr-Dy 산화물계 바리스터의 전기적, 유전적 특성)

  • 남춘우;박종아;김명준;류정선
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.10
    • /
    • pp.943-948
    • /
    • 2003
  • The microstructure and electrical characteristics of Zn-Pr-Co-Cr-Dy oxides-based varistors were investigated with Dy$_2$ $O_3$ content in the range of 0.0∼2.0 ㏖%. As Dy$_2$ $O_3$ content is increased, the average grain size was decreased in the range of 18.2∼4.6 $\mu\textrm{m}$ and the ceramic density was decreased in the range of 5.49∼4.64 g/㎤. The incorporation of Dy$_2$ $O_3$ markedly enhanced the nonlinear properties of varistors more than 9 times in nonlinear exponent, compared with the varistor without Dy$_2$ $O_3$ The varistor with 0.5∼1.0 ㏖% Dy$_2$ $O_3$ exhibited the high nonlinearity, in which the nonlinear exponent is above 55 and the leakage current is below 1.0 ${\mu}\textrm{A}$. The donor concentration and the density of interface states were decreased in the range of (4.66∼0.25)${\times}$10$\^$18//㎤ and (5.70∼1.39)${\times}$10$\^$12//$\textrm{cm}^2$, respectively, with increasing Dy$_2$ $O_3$ content. The minimum dielectric dissipation factor of 0.0023 was obtained for 0.5 ㏖% Dy$_2$ $O_3$, but further addition of Dy$_2$ $O_3$ increased it.

Microstructure and Electrical Properties of ZPCCYT Varistor Ceramics

  • Nahm, Choon-Woo;Lee, Sun-Kwon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.5
    • /
    • pp.262-265
    • /
    • 2012
  • The Microstructure and nonlinear electrical properties of the ZPCCYT (ZnO-$Pr_6O_{11}$-CoO-$Cr_2O_3$-$Y_2O_3$-$Tb_4O_7$) varistors were investigated for different amounts of $Tb_4O_7$. The addition of $Tb_4O_7$ has a significant effect on microstructure and electrical properties. Analysis of the microstructure indicated that the ceramics consisted of ZnO grain as a main phase and a few secondary phases as a mix of $Pr_6O_{11}$, $Y_2O_3$, and $Tb_4O_7$. As the amount of $Tb_4O_7$ increased, the sintered densities of pellets increased from $\rho$ = 5.70 to $5.78g/cm^3$ and the average grain size decreased from d = 4.8 to $3.6{\mu}m$. The increase in the amount of $Tb_4O_7$ increased from $E_B$ = 7,473 to 10,035 V/cm and from ${\alpha}$ = 39.7 to 52.2. In particular, it was found that the ceramics modified with 1.0 mol% in the amount of $Tb_4O_7$ are suited for the varistors for high voltage in the light of a high sintered density and a high voltage gradient.

Analysis of a.c. Characteristics in $ZnO-Bi_2O_3-Cr_2O_3$ Varistor Using Dielectric Functions (유전함수를 이용한 $ZnO-Bi_2O_3-Cr_2O_3$ 바리스터의 a.c. 특성 분석)

  • Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.14-14
    • /
    • 2009
  • In this study, we investigated the effects of Cr dopant on the bulk trap level and grain boundary characteristics of $Bi_2O_3$-based ZnO (ZB) using dielectric functions such as $Z^*$, $Y^*$, $M^*$, ${\varepsilon}^*$, and $tan{\delta}$. More than two bulk traps of $Zn_i$ and $V_o$ probably in different ionization states could be identified in ZBCr($ZnO-Bi_2O_3-Cr_2O_3$). The grain boundaries of ZBCr could be electrochemically divided into two types: sensitive to ambient oxygen and thus electrically active one and oxygen-insensitive and thus electrically inactive one.

  • PDF

The effect of cooling rate on electrical properties of ZnO varistor for Fire Alarm Circuit

  • Lee, Duck-Chool;Kim, Yong-Hyuk;Chu, Soon-Nam
    • Fire Science and Engineering
    • /
    • v.10 no.4
    • /
    • pp.3-12
    • /
    • 1996
  • The aim of the present study is to find out the effect of cooling rate on the electrical behavior of ZnO varistors. The microstructure, 1-V characteristics and complex impedance spectra were investigated under the change of cooling rates. It is found that at cooling rate $200^{\circ}$/h, nonlinearity and breakdown voltage reached a maximum value which may show that good intergranular layer is formed as a results of proper cooling rate. Complex Impedance spectras were measured as a function of frequency range 100Hz to 13MHz to determine grain and grainboundary resistance. The semicircles were attributed to the dependence of grain and grainboundary resistance on cooling rates.

  • PDF

Analysis of Element distribution and Degradation Characteristics in the grain boundary of ZnO Ceramic Varistors with EPMA (EPMA를 이용한 ZnO 세라믹 바리스터 입계의 원소분포와 열화특성 분석)

  • So, Soon-Jin;Kim, Young-Jin;Park, Young-Soon;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.64-67
    • /
    • 2000
  • Element distribution analysis and degradation characteristics of the ZnO varistors fabricated at the ambient sintering-process is investigated in this study. ZnO varistors made of Matsuoka's composition were fabricated by standard ceramic techniques. The ambient sintering-process is performed at the special electrical-furnace which is equipped with the vacuum system. The Gases of injection at sintering- process were oxygen, air, nitrogen and argon respectively. Element and quantitative analysis in the microstructure of ZnO varistors made use of EPMA equipment. Degradation characteristics were showed by DC degradation tests at $115{\pm}2\;^{\circ}C$ for period up to 13 h. From above analysis, it is found that at the DC degradation test the ZnO varistor sintered in oxygen atmosphere showed the excellent prop properties among them and these results could be explain by element and quantitative analysis in ZnO microstructure.

  • PDF

A thermal stability testing and analysis for a surge protector installed in residential distribution board (주택용 분전반에 설치되는 서지보호기의 열적 안전성 시험 및 분석)

  • Kim, Ju-Chul;Park, Jang-Bum;Ki, Che-Ouk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.339-341
    • /
    • 2009
  • Surge Protective Device(SPD) is installed by increasing information and communication equipments and home network equipments by individual home, and the amount of SPD used is increasing by revision industry regulations and strengthening equipotential grounding system. Parts of SPD installed in residential distribution board has ZnO varistor, voltage constraint type devices, but it is exposed to Temporary Overvoltage Characteristic. This thesis analyzes products through Thermal Stability test for SPD for general house and suggests the better method. As results of analysis, Gas Discharge Tube(GDT) to cut off from a leakage current and more than two kinds of safety devices to protect Thermal Runaway were needed.

  • PDF

Polarity Engineering in Polycrystalline ZnO Varistor Using Inversion Boundary (Inversion boundary를 이용한 ZnO 바리스타 극성 제어)

  • Park, Jong-Lo;Jo, Wook;Park, Chul-Jae;Jeon, Sang-Yun;Lee, Jong-Sook;Park, Chan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1315_1316
    • /
    • 2009
  • ZnO는 비선형 전류전압 특성으로 인해 급작스런 과전류로부터 회로를 보호하는 바리스터로 널리 사용되고 있다. 이러한 바리스터의 전기적 특성 및 미세조직을 제어하기 위하여 다양한 첨가물을 넣은 ZnO 바리스터의 미세구조에는 대부분의 입자에 wurtzite 구조의 결정학적 극성이 바뀌는 inversion boundary (IB)가 존재한다. ZnO의 비선형 전류전압 특성이 반도성의 ZnO 입자간 계면에 형성되는 쇼트키 장벽에 기인함을 감안할 때 계면의 결정화학적 특성에 영향을 주는 IB에 대한 이해는 필수적이다. 본 연구에서 IB가 ZnO 바리스터의 성능에 미치는 영향을 규명하기 위하여 ZnO-$Bi_2O_3$에 각각 $Sb_2O_3$ 또는 $TiO_2$ 를 첨가하여 결정학적 특성이 서로 상반되는 IB를 유도하였고, 첨가량을 조절하여 모든 입자가 IB를 가지도록 하였다. 화학 에칭을 한 시편의 SEM 관찰을 통해 입자의 형상, 크기, 분포 및 IB의 결정학적 특성 등을 분석하였다. 각 시편의 바리스터 특성은 임피던스의 온도 의존성과 상온에서의 전류-전압 특성을 통해 평가하였다. 관찰된 전기적 특성들을 입내 IB의 결정학적 구조와 이로부터 결과되는 입계면의 극성의 차이를 통해 해석하고자 한다.

  • PDF

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.