• 제목/요약/키워드: variable wind speed turbine system

검색결과 105건 처리시간 0.025초

Semi-active control of vibrations of spar type floating offshore wind turbines

  • Van-Nguyen, Dinh;Basu, Biswajit;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • 제18권4호
    • /
    • pp.683-705
    • /
    • 2016
  • A semi-active algorithm for edgewise vibration control of the spar-type floating offshore wind turbine (SFOWT) blades, nacelle and spar platform is developed in this paper. A tuned mass damper (TMD) is placed in each blade, in the nacelle and on the spar to control the vibrations for these components. A Short Time Fourier Transform algorithm is used for semi-active control of the TMDs. The mathematical formulation of the integrated SFOWT-TMDs system is derived by using Euler-Lagrangian equations. The theoretical model derived is a time-varying system considering the aerodynamic properties of the blade, variable mass and stiffness per unit length, gravity, the interactions among the blades, nacelle, spar, mooring system and the TMDs, the hydrodynamic effects, the restoring moment and the buoyancy force. The aerodynamic loads on the nacelle and the spar due to their coupling with the blades are also considered. The effectiveness of the semi-active TMDs is investigated in the numerical examples where the mooring cable tension, rotor speed and the blade stiffness are varying over time. Except for excessively large strokes of the nacelle TMD, the semi-active algorithm is considerably more effective than the passive one in all cases and its effectiveness is restricted by the low-frequency nature of the nacelle and the spar responses.

Design, analysis, and control of a variable electromotive-force generator with an adjustable overlap between the rotor and the stator

  • Zhu, W.D.;Goudarzi, N.;Wang, X.F.;Kendrick, P.
    • Smart Structures and Systems
    • /
    • 제22권2호
    • /
    • pp.139-150
    • /
    • 2018
  • A variable electromotive-force generator (VEG), which is a modified generator with an adjustable overlap between the rotor and the stator, is proposed to expand the operational range of a regular generator through a simple and robust active control strategy. It has a broad range of applications in hybrid vehicles, wind turbines, water turbines, and similar technologies. A mathematical model of the VEG is developed, and a novel prototype is designed and fabricated. The performance of the VEG with an active control system, which adjusts the overlap ratio based on the desired output power at different rotor speeds for a specific application, is theoretically and experimentally studied. The results show that reducing the overlap between the rotor and the stator of the generator results in reduced torque loss of the generator and an increased rotational speed of the generator rotor. A VEG can improve the fuel efficiency of hybrid vehicles; it can also expand operational ranges of wind turbines and water turbines and harness more power.

매트릭스컨버터와 이중여자유도발전기를 사용한 풍력발전시스템 (Wind Power System using Doubly-Fed Induction Generator and Matrix Converter)

  • 이동근;권기현;한병문;리위룽;최남섭;최영도
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.985-993
    • /
    • 2008
  • This paper proposes a new DFIG(Doubly-Fed Induction Generator) system using matrix converter, which is very effectively used for interconnecting the wind power system to the power grid. The operation of proposed system was verified by computer simulations with PSCAD/EMTDC software. The feasibility of hardware implementation was conformed by experimental works with a laboratory scaled-model of wind power system. The laboratory scaled-model was built using a motor-generator set with vector drive system, and a matrix converter with DSP(Digital Signal Processor). The operation of scaled-model was tested by modeling the specific variable-speed wind turbine using the real wind data in order to make the scaled-model simulate the real wind power system as close as possible. The simulation and experimental results confirm that matrix converter can be applied for the DFIG system.

Control and Operation of Hybrid Microsource System Using Advanced Fuzzy- Robust Controller

  • Hong, Won-Pyo;Ko, Hee-Sang
    • 조명전기설비학회논문지
    • /
    • 제23권7호
    • /
    • pp.29-40
    • /
    • 2009
  • This paper proposes a modeling and controller design approach for a hybrid wind power generation system that considers a fixed wind-turbine and a dump load. Since operating conditions are kept changing, it is challenge to design a control for reliable operation of the overall system To consider variable operating conditions, Takagi-Sugeno (TS) fuzzy model is taken into account to represent time-varying system by expressing the local dynamics of a nonlinear system through sub-systems, partitioned by linguistic rules. Also, each fuzzy model has uncertainty. Thus, in this paper, a modem nonlinear control design technique, the sliding mode nonlinear control design, is utilized for robust control mechanism In the simulation study, the proposed controller is compared with a proportional-integral (PI) controller. Simulation results show that the proposed controller is more effective against disturbances caused by wind speed and load variation than the PI controller, and thus it contributes to a better quality wind-hybrid power generation system.

선로제약을 고려한 복수개의 마이크로그리드 최적운영 기법에 관한 연구 (A Study on Optimal Operation Method of Multiple Microgrid System Considering Line Flow Limits)

  • 박시나;안정열
    • 한국산학기술학회논문지
    • /
    • 제19권7호
    • /
    • pp.258-264
    • /
    • 2018
  • 본 논문은 마이크로 그리드 최적 운영을 위해 Differential Search (DS) 알고리즘을 적용하였다. DS 알고리즘은 이주하는 생물의 유사 브라운 운동 형태의 임의보행 (random-walk)을 모의하여 개발된 알고리즘이다. DS 알고리즘은 다른 최적화 알고리즘과 달리 한 개 이상의 개체를 동시에 사용 할 수 있고, 유사 최적해중에서 전역 최적 해를 선별하는 직진성 특성으로 multi-modal 함수들의 해법을 위한 성공적인 탐색 전력을 지니고 있으며, 높은 비선형성과 불연속성을 갖는 전력계통의 다른 분야에도 효율적으로 적용될 수 있다. 마이크로 그리드 시스템은 풍력 발전기, 디젤발전기, 연로전지 및 태양광 발전기로 구성된다. 풍력 발전기는 가변 출력특성을 이용하여 모델링 하였다. 연료비용과 연료가 전력으로 변환되는 경우의 효율을 포함시켜 시스템의 비용을 최소화 하였으며, 마이크로 그리드 단독 운용에 관해서만 분석하였다. 본 연구는 신재생 에너지원 기반의 마이크로 그리드의 최적 운영에 대해 코딩의 단순성, 빠른 수렴 속도, 정확성 및 효율성을 갖춘 DS 알고리즘을 적용하여 다른 알고리즘의 최적 값과 비교하였다.

Comparative Study between Two Protection Schemes for DFIG-based Wind Generator Fault Ride Through

  • Okedu, K.E.;Muyeen, S.M.;Takahashi, R.;Tamura, J.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권1호
    • /
    • pp.8-16
    • /
    • 2012
  • Fixed speed wind turbine generators system that uses induction generator as a wind generator has the stability problem similar to a synchronous generator. On the other hand, doubly fed induction generator (DFIG) has the flexibility to control its real and reactive powers independently while being operated in variable speed mode. This paper focuses on a scheme where IG is stabilized by using DFIG during grid fault. In that case, DFIG will be heavily stressed and a remedy should be found out to protect the frequency converter as well as to allow the independent control of real and reactive powers without loosing the synchronism. For that purpose, a crowbar protection switch or DC-link protecting device can be considered. This paper presents a comparative study between two protective schemes, a crowbar circuit connected across the rotor of the DFIG and a protective device connected in the DC-link circuit of the frequency converter. Simulation analysis by using PSCAD/EMTDC shows that both schemes could effectively protect the DFIG, but the latter scheme is superior to the former, because of less circuitry involved.

Wind Power Grid Integration of an IPMSG using a Diode Rectifier and a Simple MPPT Control for Grid-Side Inverters

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제10권5호
    • /
    • pp.548-554
    • /
    • 2010
  • In this paper, a 1.5 kW Interior Permanent Magnet Synchronous Generator (IPMSG) with a power conditioner for the grid integration of a variable-speed wind turbine is developed. The power-conditioning system consists of a series-type 12-pulse diode rectifier powered by a phase shifting transformer and then cascaded to a PWM voltage source inverter. The PWM inverter is utilized to supply sinusoidal currents to the utility line by controlling the active and reactive current components in the q-d rotating reference frame. While the q-axis active current of the PWM inverter is regulated to follow an optimized active current reference so as to track the maximum power of the wind turbine. The d-axis reactive current can be adjusted to control the reactive power and voltage. In order to track the maximum power of the wind turbine, the optimal active current reference is determined by using a simple MPPT algorithm which requires only three sensors. Moreover, the phase angle of the utility voltage is detected using a simple electronic circuit consisting of both a zero-crossing voltage detecting circuit and a counter circuit employed with a crystal oscillator. At the generator terminals, a passive filter is designed not only to decrease the harmonic voltages and currents observed at the terminals of the IPMSG but also to improve the generator efficiency. The laboratory results indicate that the losses in the IPMSG can be effectively reduced by setting a passive filter at the generator terminals.

블레이드 형태에 따른 소형 수직축 풍력발전기의 실험적 연구 (Experimental Study of Small Vertical Axis Wind Turbine according to Type of Blades)

  • 이민구;오훈;박왈서
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.88-92
    • /
    • 2017
  • 풍력은 자원이 풍부하고, 끊임없이 재생되며, 공해물질 배출이 없어서 친환경적인 점에서 화석에너지 고갈 시에 대비한 유망한 대체 에너지원으로서 각광받는 에너지이다. 풍력발전기는 회전축의 방향에 따라 수평축 풍력발전기와 수직축 풍력발전기로 구분되며, 수직축은 발전효율이 낮은 단점이 있는 반면에 바람의 방향에 영향을 받지 않아 요잉 시스템이 필요가 없어 구조가 간단하고, 저 풍속에서도 풍력발전이 가능한 장점이 있어 현재 소형 수직축 풍력발전기가 주목받고 있다. 본 연구에서는 저 풍속에서도 발전 가능한 자이로밀형, 힌지형, 양문형의 블레이드 형태에 따른 소형 수직형 풍력발전기를 이용하여 1m/s~11m/s의 가변풍속에 따른 발전기의 출력전압 및 출력전류를 분석하였다. 연구결과 최대풍속 11m/s일 때 발전기 출력전압은 양문형 블레이드를 적용 시 자이로밀형 블레이드보다 67%, 힌지형 블레이드보다 9%가 증가되었으며, 발전기 출력전류는 양문형 블레이드를 적용 시 자이로밀형 블레이드보다 93%, 힌지형 블레이드보다 5%가 증가되었다. 본 연구를 통해 저풍속 및 고풍속에서의 발전이 용이한 양문형 블레이드의 우수한 출력특성과 실용화 가능성을 확인하였다.

Wind Energy Interface to Grid with Load Compensation by Diode Clamped Multilevel Inverters

  • Samuel, Paulson;Naik, M. Kishore;Gupta, Rajesh;Chandra, Dinesh
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.271-281
    • /
    • 2014
  • Fluctuating wind conditions necessitate the use of a variable speed wind turbine (VSWT) with a AC/DC/AC converter scheme in order to harvest the maximum power from the wind and to decouple the synchronous generator voltage and frequency from the grid voltage and frequency. In this paper, a combination of a three phase diode bridge rectifier (DBR) and a modified topology of the diode clamped multilevel inverter (DCMLI) has been considered as an AC/DC/AC converter. A control strategy has been proposed for the DCMLI to achieve the objective of grid interface of a wind power system together with local load compensation. A novel fixed frequency current control method is proposed for the DCMLI based on the level shifted multi carrier PWM for achieving the required control objectives with equal and uniform switching frequency operation for better control and thermal management with the modified DCMLI. The condition of the controller gain is derived to ensure the operation of the DCMLI at the fixed frequency of the carrier. The converter current injected into the distribution grid is controlled in accordance with the wind power availability. In addition, load compensation is performed as an added facility in order to free the source currents being fed from the grid of harmonic distortion, unbalance and a low power factor even though the load may be unbalanced, non-linear and of a poor power factor. The results are validated using PSCAD/EMTDC simulation studies.

Comparison of Various Methods to Mitigate the Flicker Level of DFIG in Considering the Effect of Grid Conditions

  • Kim, Yun-Seong;Marathe, Aditya;Won, Dong-Jun
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.612-622
    • /
    • 2009
  • The short circuit ratio (SCR) of a given grid is able to show the stability of the system in the case of unwanted elements, such as wind turbulence. This paper presents the simulation of a model of the doubly fed induction generator in the simulation software PSCAD/EMTDC. This model has been used to study flicker during continuous operation and the effect of SCR and grid impedance angle on flicker emission. Simulation results show that compensation of the stator reactive power is an effective method to considerably reduce the flicker levels, irrespective of the grid conditions.