• Title/Summary/Keyword: vaporizer

Search Result 90, Processing Time 0.03 seconds

Study of Nano-scale Fullerene (C60) Clusters Formed in Micro-sized Droplet by UV Irradiation

  • Yeo, Seung-Jun;Ahn, Jeung-Sun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.571-571
    • /
    • 2012
  • We discovered the formation of C60 aggregates in solution by means of photoluminescence spectroscopic study on C60 in solutions. From the in-depth investigation of temperature dependence of the luminescence of C60 in toluene, benzene and CS2 solutions, we reported that the C60 aggregates are formed during cooling at the freezing temperature of these solvents. Furthermore, the C60 aggregates can be changed to stable structures by irradiating with UV pulse-laser (Nd:YAG laser, 355nm). As a consequence, we could obtain nano-scale photo-polymerized C60 clusters, which appear as round-shaped nano- scale particles in high resolution transmission electron-microscopy (HRTEM) images. However, the yield of the nano-scale C60 clusters obtained by this method is too small. So we designed and developed a system to obtain C60 cluster of macroscopic quantity by using ultrasonic nebulizer. In this system, C60 solution was vaporized to several micro-sized droplets in vacuum, resulting in the formation of C60 aggregates by evaporating solvent (toluene). The system was invented to produce nano-scale carbon clusters by the irradiation of UV light upon C60 aggregates in vacuum. We have characterized the products, C60 cluster, obtained from the system by using UV absorption spectra and HPLC spectra. Although the products have a possibility of inclusion various forms of C60 cluster, results support that the product formed from the system by using vaporizer method establishes a new method to obtain C60 cluster in macroscopic quantity. In the presentation, the details of the system and the results of characterization are reported.

  • PDF

Hydrogen Peroxide Gas Generator with Dual Catalyst Beds (이원 촉매를 이용한 과산화수소 가스발생기)

  • Rang, Seong-Min;An, Seong-Yong;Gwon, Se-Jin;Gwon, Hyeok-Mo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.3
    • /
    • pp.87-92
    • /
    • 2006
  • The rocket grade hydrogen peroxide has been widely used as a monopropellant in propulsion systems. In the present paper, we described an experimental study of a catalytic reactor that employs two stage catalyst beds to enhance the low temperature performance of the reactor inlet. $K_2MnO_4$ was chosen as the catalyst for the initial stage of the reactor bed for its superior behavior in the low temperature regime. Alumina sol-gel method was successfully applied for coating $K_2MnO_4$ on a reactor bed of cordierite monolith. LSC was used for the catalyst of the second stage of the reactor. The reactor with combined catalyst beds was built and tested to exhibit superior performance in low temperature regime and high decomposition efficiency.

Procedure of Seismic Performance Evaluation of LNG Receiving Terminal Facilities (천연가스 생산기지 시설물의 내진성능평가 절차)

  • Lee, Tae-Hyung;Lee, Eunsuk;Park, Taekyu;Hong, Seong Kyeong;Kim, Joonho
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.110-115
    • /
    • 2014
  • It is crucial for important facilities to withstand strong earthquakes because their damage may cause undesirable socio-economic effect. A liquefied natural gas (LNG) receiving terminal is one of the lifeline facilities whose seismic safety needs to be guaranteed. Even though all operating LNG receiving terminals in Korea were seismically designed, old design codes do not guarantee to comply with the current seismic design codes. In addition, if the constructional materials have been deteriorated, the seismic capacity of facilities may be also deteriorated. Therefore, it is necessary that the seismic performance of LNG receiving terminals is evaluated and the facilities that lack of seismic capacity have to be rehabilitated. In this paper, a procedure of seismic performance evaluation of such facilities is developed such that the procedure consists of three phases, namely pre-analysis, analysis, and evaluation phases. In the pre-analysis phase, design documents are reviewed and walk-on inspection is performed to determine the current state of the material properties. In the analysis phase, a structural analysis under a given earthquake or a seismic effect is performed to determine the seismic response of the structure. In the evaluation phase, seismic performance of the structure is evaluated based on limit states. Two of the important facilities, i.e. the submerged combustion vaporizer (SMV) and pipe racks of one of the Korean LNG receiving terminals are selected and evaluated according to the developed procedure. Both of the facilities are safe under the design level earthquake.

Development of Controlling and Analyzing Software for Portable Atomic Emission Spectrometry (휴대용 원자 방출 분광계를 위한 제어 및 분석용 소프트웨어 개발)

  • Lee, Sang Chun;Lee, Chang-Soo;Jung, Min-Soo;Ryu, Dong-Hang
    • Analytical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • This study focuses on developing a controlling and analyzing software for the portable atomic emission spectrometer equipped with an electrothermal vaporizer(ETV) that can perform the in-situ trace analysis of heavy metal ions dissolved in water. The software works well for a notebook PC and it is exclusively developed for the real time analysis with a line filter and a photomultiplier light detector. The program is designed to operate under Windows 95 environment and either Korean or English can be used as a main language. The Delphi 2.0 language software is mainly used for programing. The program is designed to make a calibration curve and the system users can get the analytical data in a short time. And a final report can be generated without having difficulties. This software can be easily modified for other analytical atomic spectrometers.

  • PDF

Analysis of 236 Pesticides in Apple for Validation of Multiresidue Method using QuEChERS Sample Preparation and PTV-GC/TOFMS Analysis (QuEChERS법과 PTV-GC/TOFMS 이용 잔류농약 분석법 개발을 위한 사과시료 중 236종 농약의 동시분석)

  • Ju, Ok-Jung;Kwon, Hye-Young;Park, Byeong-Jun;Kim, Chan-Seob;Jin, Yong-Duk;Lee, Je-Bong;Yun, Seo-Hee;Son, Kyung-Ae;Hong, Su-Myeong;Im, Geon-Jae
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.401-416
    • /
    • 2011
  • The recent trend for pesticide residue analysis in food involves fast cleanup and use of mass spectrometry to achieve quantitative and qualitative analysis at the same time. Recently, the QuEChERS (quick, easy, cheap, effective, rugged and safe) multi-reside method has received much attention as a fast extraction and cleanup method of pesticide residue analysis. Therefore, multi-residue analysis of 236 pesticides was tested with the QuEChERS method by concurrent use of PTV-GC/TOFMS (gas chromatography/ time-of-flight mass spectrometry with programmable temperature vaporizer). PTV condition was optimized and when the method was applied to apples, pesticide recovery rates (spiked at 400 ng/g) ranged from 80% to 120%, and RSD values were under 10% for most compounds. The results showed that the QuEChERS sample preparation and PTV-GC/TOFMS analysis can be applied to multi-residue analysis of pesticides in fruits and vegetables.

The Component and Compositional Analysis of Trace Materials in LPG (LPG 잔류물질의 성분 및 조성 분석)

  • Kim, Yeong-Gu
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.4
    • /
    • pp.317-323
    • /
    • 2002
  • The composition of trace materials in domestic circulated LPG are determined. The sampling points are two cylinders of LPG cylinder re-inspection center, six vaporizer of LPG-supplying group facilities, and the compressed oil from one LPG station. In the trace materials from cylinder of LPG cylinder-reinspection center, alkene and diene derivative (No. of carbon ${\leq}9),$ aromatic compounds, and tarry chemicals(No. of carbon ${\geq}10)$ are 1.5~39.9%, 0.7%, 57.8~96.0%, respectively. While in the trace materials from LPG-supplying group facilities and in the oil from LPG station, tarry chemicals(No. of carbon>10) exceed 96.6%. Nine samples are classified into three clusters. One cluster is the sample of SE company cylinder-reinspection center(Euclidian distance between S company LPG cylinder-reinspection center and SE company cylinder-reinspection center=2.11), the other is the sample of SE company LPG cylinder-reinspection center(Euclidian distance between from samples of LPG-supplying group facilities including compressed oil from LPG station=0.110) the third is the samples of LPG-supplying group facilities(Euclidian distances among them<0.075). The compositions of samples from LPG-supplying group facilities are similar to those of oil from LPG station. Furthermore densities of samples from LPG-supplying group facilities and compressed oil in LPG station are 0.873, 0.873 [0.00798 (99% confidence limits) respectively. It was presumed that tarry chemicals had been leached from the compressed oil of LPG supplying facilities.

A Study of Thermo-Mechanical Analysis for the Design of High Pressure Piping System for Natural Gas Fuel Vessel (천연가스 연료선박의 고압 이중 배관 설계를 위한 열-구조 해석에 관한 연구)

  • Park, Seong-Bo;Sim, Myung-Ji;Kim, Myung-Soo;Kim, Jeong-Hyeon;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.425-431
    • /
    • 2015
  • LNG (liquefied natural gas) is considered the best alternative eco-fuel, and many studies on the LNG fuel system have been performed to use LNG as the fuel for ships. For the LNG fuel supply system, natural gas transfers from the vaporizer to the engine in the gaseous state with a temperature of $50^{\circ}C$ and a pressure of 35MPa. Therefore, a structural safety evaluation of the double-walled pipelines considering thermal load is essential. In this article, an uniaxial tensile test for super duplex stainless steel, material for double-walled pipe, according to the annealing time was carried out to analyze the thermal effect. In addition, thermo-structural analysis of the high temperature-high pressure double-walled pipe with fixed supports that are now used widely was carried out to evaluate the structural safety. To minimize stress concentration of the connection point between the support and inner pipe, the shapes of the new type support that can slip through inner pipe were proposed, and the supports which has best structural performance was selected using the results from the thermo-structural analyses of new supports and an analysis of the whole double-walled pipeline was performed to ensure structural safety. These results can be used as a database for the design of double-walled pipelines and sliding support.

Metalorganic Chemical Vapor Deposition of Copper Films on TiN Substrates Using Direct Liquid Injection of (hfac)Cu(vtmos) Precursor ((hfac)Cu(vtmos)의 액체분사법에 의한 TiN 기판상 구리박막의 유기금속 화학증착 특성)

  • Jun, Chi-Hoon;Kim, Youn-Tae;Kim, Dai-Ryong
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1196-1204
    • /
    • 1999
  • We have carried out copper MOCVD(metalorganic chemical vapor deposition) onto the reactive sputtered PVD-TiN and rapid thermal converted RTP-TiN substrates using direct liquid injection for effective delivery of the (hfac)Cu(vtmos) [$C_{10}H_{13}O_{5}CuF_{6}$Si: 1,1,1,5,5,5-hexafluoro-2,4- pentadionato (vinyltrimethoxysilane) copper (I)] precursor. Especially, the influences of deposition conditions and the substrate type on growth rate, crystal structure, microstructure, and electrical resistivity of copper deposits have been discussed. It is found that the film growth with 0.2ccm precursor flow rate become mass-transfer controlled up to Ar flow rate of 200sccm and pick-up rate controlled at a vaporizer above 1.0Torr reactor pressure. The surface-reaction controlled region from 155 to 225$^{\circ}C$ at 0.6Torr reactor pressure results in the apparent activation energies of 12.7~14.1kcal/mol, and above 224$^{\circ}C$ the growth rate with $H_2$ addition could be improved compared to the pure Ar carrier. The Cu/RTP-TiN structures which have high copper nucleation density in initial stage of growth show more pronounced (111) preferred orientations and lower electrical resistivities than those on PVD-TiN. The variation of electrical resistivity with substrate temperature reflects the three types of film microstructure changes, showing the lowest value for the deposit at 165$^{\circ}C$ with small grains of good contacts.

  • PDF

Reduction Effect of Aromatherapy on Stress and Insomnia (아로마요법의 스트레스 및 수면장애 감소효과)

  • Park, Sang-Ock;Kim, Seok-Beom;Lee, Kyeong-Soo;Kang, Pock-Soo
    • Journal of agricultural medicine and community health
    • /
    • v.27 no.2
    • /
    • pp.17-26
    • /
    • 2002
  • Reducing the level of stress and insomnia by aromatherapy is proposed as a method of self-care and health promotion in the future. Of the people who received aromatherapy from July, 1999 to February, 2000 at the Complementary and Alternative Medicine Center at the Gyeongu City Health Center, 48 people agreed to participate in a questionnaire survey, presented before and after their aromatherapy, and the data were analyzed. When the people received aromatherapy at the Complementary and Alternative Medicine Center, they inhaled the aroma from a vaporizer and when at home, they inhaled from a tissue, gauze or washbowl. Two sessions per week (2 hrs./session) were provided at the Center in the total 1-month duration of the therapy. The oil made from a blend of clarysage, geranium, rose at a ratio of 3:2:1 was used for relieving stress, and the oil made from a blend of clarysage, lavender, and lemon at 2:2:1 ratio was used for relieving insomnia. The scores of stress of 92.5 17.5 points before aromatherapy significantly reduced to $87.4{\pm}4.2$ points after therapy(p<0.01), and the scores of insomnia of $2.5{\pm}1.2$ points before aromatherapy significantly reduced to $1.0{\pm}1.1$ points after therapy(p<0.01). The reduction in stress and insomnia from aromatherapy was more significant in those who were experiencing high levels of stress and insomnia. Therefore, stress and its related insomnia can be effectively relieved with proper application of aromatherapy. With benefits such as little side-effects, convenient and simple education, low cost, and the do-it-yourself feature. aromatherapy can be expanded into a self-management program for promoting health of the community people.

  • PDF

Lung Clearance of Inhaled $^{99m}Tc$-DTPA by Urine Excretion Ratio (소변내 방사능배설량비를 이용한 $^{99m}Tc$-DTPA 폐청소율에 관한 연구)

  • Suh, G.Y.;Park, K.Y.;Jung, M.P.;Yoo, C.G.;Lee, D.S.;Kim, Y.W.;Han, S.K.;Jung, J.K.;Lee, M.C.;Shim, Y.S.;Kim, K.Y.;Han, Y.C.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.357-366
    • /
    • 1993
  • Background: Lung clearance of inhaled $^{99m}Tc$-DTPA reflects alveolar epithelial permeability and it had been reported as more sensitive than conventional pulmonary function tests in detecting lung epithelial damage. However, measuring lung clearance of inhaled $^{99m}Tc$-DTPA by gamma camera may not always reflect alveolar epithelial permeability exactly because it is influenced by mucociliary clearance depending on the site of particle deposition. Moreover, this method takes much time and patient's effort because he has to sit or lie still in front of the camera for a prolonged period. Most of the absorbed DTPA is excreted in urine within 24 hours and the amount of excreted DTPA in urine during the first few hours after inhalation is influenced by absorption rate which is correlated with the alveolar-epithelial permeability suggesting that the urinary excretion, especially in first few hours, may be an alternate index for lung clearance. The purpose of this study was to evaluate the usefulness of ratio of excreted $^{99m}Tc$-DTPA in 2 hour and 24 hour urine as an index of alveolar-epithelial damage. Methods: Pulmonary function tests including diffusing capacity and lung clearance of $^{99m}Tc$-DTPA measured by gama camera ($T_{1/2}$) and 2hr/24hr urine excretion ratio (Ratio) of inhaled $^{99m}Tc$-DTPA in 8 normal subjects and 14 patients with diffuse interstitial lung disease were compared. Results: 1) In the normal control, there was significant negative correlation between the $T_{1/2}$ and the Ratio (r=-0.77, p<0.05). In patients with diffuse interstitial lung disease, there also was significant negative correlation between $T_{1/2}$ and Ratio(r=-0.63, p<0.05). 2) In diffuse interstitial lung disease patients, the $T_{1/2}$ was $38.65{\pm}11.63$ min which was significantly lower than that of normal control, $55.53{\pm}11.15$ min and the Ratio was $52.15{\pm}10.07%$ also signifantly higher than that of the normal control, $40.43{\pm}5.53%$ (p<0.05). 3) There was no significant correlations between $T_{1/2}$ or Ratio and diffusing capactiy of lung in both patients and controls (p>0.05). Conclusion: These results suggests that 2hr/24hr urine excretion ratio of inhaled $^{99m}Tc$-DTPA is a useful simple bedside test in assessing alveolar epithelial permeability and that it may be used as an additive follow-up test in patients with diffuse interstitial lung disease complementing conventional pulmonary function tests.

  • PDF