• 제목/요약/키워드: valve life-time

검색결과 60건 처리시간 0.03초

파일럿형 공기압 방향제어 밸브의 누설 고장판정 기법에 관한 연구 (Leakage Failure Determination Method of Pilot Pneumatic Directional Control Valve)

  • 강보식;김경수;장무성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권4호
    • /
    • pp.230-235
    • /
    • 2014
  • The failure modes of pneumatic directional control valves include leakage, wear of the spool seal, and sticking of the spool. Among them, the main failure mode of the valve is leakage. The leakage is caused by the wear of the spool seal. However, due to the characteristics of the seal material, the leakage rate is fluctuated a lot rather than constantly increased over time. If life analysis is performed using the first time data of leakage failure, predicted life cycles can be different from the real life cycles. This paper predicts life cycles of the pilot pneumatic directional control valve based on the three point moving average which considers the average of the fluctuating leakage rate.

Development of Life Test Equipment with Real Time Monitoring System for Butterfly Valves

  • Lee, Gi-Chun;Choi, Byung-Oh;Lee, Young-Bum;Park, Jong-Won;Nam, Tae-Yeon;Song, Keun-Won
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권1호
    • /
    • pp.40-46
    • /
    • 2017
  • Small valves including ball valves, gate valves and butterfly valves have been adopted in the fields of steam power generation, petrochemical industry, carriers, and oil tankers. Butterfly valves have normally been applied to fields where in narrow places installing the existing valves such as gate valves and ball valves have proven difficult due to the surrounding area and the heavier of these valves. Butterfly valves are used to control the mass flow of the piping system under low pressure by rotating the circular disk installed inside. The butterfly valve is benefitted by having simpler structure in which the flow is controlled by rotating the disc circular plate along the center axis, whereas the weight of the valve is light compared to the gate valve and ball valve above-mentioned, as there is no additional bracket supporting the valve body. The manufacturing company needs to acquire the performance and life test equipment, in the case of adopting the improving factors to detect leakage and damage on the seat of the valve disc. However, small companies, which are manufacturing the industrial valves, normally sell their products without the life test, which is the reliability test and environment test, because of financial and manpower problems. Furthermore, the failure mode analysis of the products failed in the field is likewise problematic as there is no system collecting the failure data on sites for analyzing the failures of valves. The analyzing and researching process is not arranged systematically because of the financial problem. Therefore this study firstly tried to obtain information about the failure data from the sites, analyzed the failure mode based on the field data collected from the customers, and then obtained field data using measuring equipment. Secondly, we designed and manufactured the performance and life test equipment which also have the real time monitoring system with the naked eye for the butterfly valves. The concept of this equipment can also be adopted by other valves, such as the ball valve, gate valve, and various others. It can be applied to variously sized valves, ranging from 25 mm to large sized valves exceeding 3000 mm. Finally, this study carries out the life test with square wave pressure, using performance and life test equipment. The performance found out that the failures from the real time monitoring system were good. The results of this study can be expanded to the other valves like ball valves, gate valves, and control valves to find out the failure mode using the real time monitoring system for durability and performance tests.

승모판막 이식수술 -5예 보고- (Mitral Valve Replacement -Report of Five Cases-)

  • 송요준
    • Journal of Chest Surgery
    • /
    • 제7권2호
    • /
    • pp.189-200
    • /
    • 1974
  • The mitral valve replacement with Beall prosthetic valve was performed on three patients, and double valve replacement. aortic and mitral valve, was performed in this department.1) The preoperative studies about the first case were compatible with mitral steno-insufficency.The diseased mitral valve was replaced with the medium sized Beall prosthetic valve under the cardiopulmonary hypass using hypothermic hemodilution technique. The total perfusion time was eighty minutes. Immediate postoperative course was smooth, but this patient was died of asphyxia due to tracheomalacia complicated after tracheostomy 3 months after operation. Autopsy on this patient revealed that no thrombus and no ball variance could be found, and endothelization on the valve cuff was satisfactory. 2) The preoperative studies on the second case were compatible with mitral insufficiency. The diseased mitral valve was replaced with the medium sized Beall prosthetic valve under the cardiopulmonary bypass using hypothermic hemodilution technigue. The total perfusion time was 123 minutes. This patient was discharged in good condition and follow-up study after 16 months revealed the patient had enjoyed healthy life. 3) The preoperative studies about the third case were compatible with aortic insufficiency and mitral stenoinsufficiency. The diseased valves were replaced with type 2 sutureless Magovern aortic valve and the medium sized Beall mitral prosthesis under cardiopulmonary bypass using hypothermic hemodilution technIque and coronary artery perfusion. The total perfusion time was 155 minutes. This patient was discharged in good condition, but thromboembolism was developed 2 months after discharge. 4) The preoperative studies about the fourth case were compatible with mitral insufficiency. The diseased mitral valve was replaced with the medium sized Beall prosthetic valve. The total perfusion time was 132 minutes. The atrioventricular block developed just after operation but converted to normal sinus rhythmn on the third postperative day. The preoperative NYHA functional classification IV was converted to Class 1 or 11 at the time of discharge and this patient enjoyed healthy life. Attendum; The fifth case, nineteen years old male with mital insufficiency underwent Beall valve replacement and his course was uneventful 2 weeks after operation.

  • PDF

개폐식 밸브를 사용한 공압 서보 시스템의 효율적 밸브 개폐에 관한 연구 (Study on the Effective Operating Method on-off Valves of Pneumatic Servo System)

  • 황웅태;최서호;이정오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.820-825
    • /
    • 1996
  • This paper is concerned with effective operating method of pneumatic on-off valves for improving position control accuracy, valve life-time and position settling time using modified pulse width modulation with dead-zone. The pneumatic system using on-off valves studied in this paper has advantage of simple construction and low cost compared with a system with servo-valves. The performance of proposed control system is investigated experimentally for the position control of a pneumatic cylinder using on-off valves. Experimental results show that the proposed algorithm for valve operation can be used to obtain fast and accurate position control and to prevent on-off valves from unnecessary switching.

  • PDF

플러그인형 소형 공기압 매니폴드 밸브의 수명 및 성능열화특성에 관한 연구 (Life and Performance Degradation Characteristics for Small-Sized Plug-In Type Pneumatic Manifold Valves)

  • 강보식;이충성;김형의
    • 대한기계학회논문집A
    • /
    • 제35권11호
    • /
    • pp.1445-1451
    • /
    • 2011
  • 공기압 밸브는 자동화 시스템에 공급되는 공기를 제어하는 기능을 지닌 핵심부품으로 널리 사용되고 있다. 하지만 공기압 밸브가 고장이 발생하면 설치되는 시스템의 특성상 전체 시스템에 영향을 미쳐 막대한 손실을 야기 시킬 수 있다. 이로 인하여 최근 신뢰성에 대한 중요성 및 소비자의 요구수준이 날로 증대되고 있어 밸브의 수명을 예측하여 제품의 신뢰성을 확보하기 위한 수명분포, 수명열화 특성 등과 같은 연구가 널리 진행되고 있다. 따라서 본 논문에서는 공기압 밸브의 수명예측을 위한 핵심요소인 모수 도출 및 제안을 위하여, 최근 널리 사용되고 있는 플러그인형 공기압 매니폴드 밸브의 척도모수 및 $B_{10}$ 수명값을 완전데이터 수명관측 방법으로 측정하였으며, 수명분포 특성을 확인하기 위하여 상관계수값을 이용한 분포 적합성 검토와 주요성능 결정항목인 동적응답과 누설이 수명에 따라 열화되는 특성을 분석한 결과를 제시한다.

T-50 항공기 유압조절 밸브 수명연장 방안 (A Study on Life Cycle Extension of T-50 Aircraft Hydraulic Control Valve)

  • 남용석;김태환;백승진;김승현;송석봉
    • 항공우주시스템공학회지
    • /
    • 제4권2호
    • /
    • pp.16-20
    • /
    • 2010
  • In General, the hydraulic system of T-50 Advanced Trainer is applied to flight control system, wheel & Brake system and fuel system for aircraft operation. The hydraulic system is operation with pressure of 3000psi. and many mechanical parts which is operated by hydraulic system has been stressed in incomplete environment same as heat and friction. for example, Oil leakage had occurred in the shutoff valve of FFP used in a certain period of time. After study, The crack progressed by fatigue due to the irregular hydraulic pressure and vibration has been identified as the reason of oil leakage. This paper presents life cycle extension plans of FFP shutoff valve by configuration improvements of shutoff valve and FFP hydraulic motor.

  • PDF

중복판막수술에 대한 임상적 연구 (Clinical study of multiple cardiac valve operation)

  • 김승진
    • Journal of Chest Surgery
    • /
    • 제22권6호
    • /
    • pp.1036-1043
    • /
    • 1989
  • Seventy eight patients underwent operation for combined multiple valve disease, with an overall early mortality of 14.1 % from January, 1983 to September, 1988 in the department of thoracic and cardiovascular surgery of Pusan National University Hospital. All of the above cases had combined multiple valve procedures. There were 33 mitral valve replacements and tricuspid annuloplasties, 33 aortic and mitral valve replacements, 5 aortic and mitral valve replacements with tricuspid annuloplasties, 3 aortic valve replacements and mitral annuloplasties, 1 open mitral commissurotomy and tricuspid annuloplasty and, 1 mitral valve replacement and primary closure of tricuspid valve cleft, 1 mitral valve replacement and aortic commissurotomy, 1 mitral, aortic and tricuspid valve replacement were done. 44 were male and 34 were female and the age distribution was from 14 to 57 with mean 38 year old. According to NYHA[New York Heart Association] classification, 49 patients were class I, 19 patients were class Il and 10 were class IV. Average perfusion time was 205.3 minutes. The live patients perfusion time was 178.7 minutes while that of dead ones was 272.0 minutes. Early deaths within 30 days from operation were 11 cases, 6 of which were due to low cardiac output, 3 were acute renal failure and 2 were cardiac rupture. The 65 patients were followed up from 2 to 30 months for a total 20.6 patient years. 1 patient committed suicide because of postoperative depression 1 year after operation. All of the survivors were enjoying their daily life and their NYHA class was superior to the preoperative ones.

  • PDF

위성추진시스템 솔레노이드 밸브 개발 (A Development of Solenoid Valve for Satellite Propulsion System)

  • 김경식;백기봉;박은주;조승환;김수겸
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.456-459
    • /
    • 2011
  • 위성의 자세제어용 추력시스템에 대한 연료 공급용 솔레노이드 밸브의 국산화를 위해 Dual-Type의 솔레노이드 밸브를 개발하였다. Hydrazine을 연료로 사용하는 위성용 밸브는 반응속도, 유량, 누설 등의 기본성능 외에 수십만 번의 Cycle life, 충격 및 진동, 극저온 등의 환경 요인을 만족해야 한다. 본 논문에서는 설계 및 제작하고 질소 공압 장치를 이용한 성능 시험을 수행하였다.

  • PDF

4사이클 왕복동식 엔진에 있어서 흡배기 변동압 측정치를 이용한 흡기효율 최적화 컴퓨터 시뮬레이션 (Optimization of valve events in a 4 cycle reciprocating engine using measured intake and exhaust port pressures)

  • 오세종;진영욱;정재화
    • 대한기계학회논문집
    • /
    • 제13권3호
    • /
    • pp.500-507
    • /
    • 1989
  • 본 논문에서는 흡배기 변동압을 실측하여 이것을 계산의 입력수치로 사용 하는 전산프로그램을 개발하여 간단하면서도 정확한 사이클 시뮬레이션이 가능하도록 하여 체적효율을 예측하였다.

작동 횟수에 따른 연소기 산화제 개폐밸브 작동 특성 (Operating Characteristics of a Main Oxidizer Shut-off Valve According to Operating Times)

  • 홍문근
    • 한국추진공학회지
    • /
    • 제24권5호
    • /
    • pp.77-83
    • /
    • 2020
  • 본 논문에서 연소기 산화제 개폐밸브의 작동 특성 변화를 확인하기 위해 극저온 및 상온 작동 시험으로 이뤄진 밸브 내구성시험 내용과 함께 시험 결과를 소개하였다. 극저온 및 상온 내구성시험을 통해 밸브 작동 횟수와 상관없이 밸브의 작동 특성이 매우 안정적으로 유지되는 것을 확인하였다. 밸브 작동 특성을 대표하는 주요 압력 측정값과 마찰력 및 스프링 예측값이 밸브 내구성시험 내내 대략 최대 ±3% 이내 수준에서 동일하게 측정되었으며, 연소기 산화제 개폐밸브의 이와 같은 안정적인 밸브 작동 특성은 해당 밸브가 적용되는 엔진의 안정적인 시동 및 종료를 위한 중요한 역할을 할 수 있을 것으로 기대한다.