Experimental Study on Heat Transfer Performance of Plate Type Absorber with Variation of Solution Flow Rate (용액유량에 따른 플레이트 흡수기의 흡수 열전달 특성 실험)

  • Moon, C.G.;Bang, G.S.;Kim, J.D.;Yoon, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1548-1553
    • /
    • 2003
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of development of high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is the most effective to improve the performance of absorber with the largest heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which can increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, horizontal tube bundle type. The size of plate absorbers were made for $0.4m{\times}0.6m$ and the design object of a refrigeration capacity was lRT. In this experiment, three kind plate absorbers which were flat plate, dimple plate and groove plate were used. The results were less than the design object values, that is, the refrigeration capacity was about $0.3{\sim}0.4RT$ and the overall heat transfer coefficient was $500{\sim}600kcal/m^2h^{\circ}C$ at the standard conditions.

  • PDF

The Relationship between Coastal Cold Water and Catch Conditions of Common Squid(Todarodes Pacificus STEENSTRUP) in the East Sea of Korea in Summer (여름철 동해안 연안 냉수와 오징어 어황과의 관계)

  • Park, Jong-Hwa;Park, Kwang-Ho;Lee, Ju-Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.105-116
    • /
    • 1998
  • This paper, examines the relationship between water temperatures and fishing conditions of common squid by the squid angling fishery from June to September in 1993-1995. The condition of the common squid fishing largely depended on the fluctuation of water temperature in the coastal area of Gampo. Monthly mean water temperatures during June m September in 1993 and 1994 were relatively higher than those in 1995 in Gampo area. But the values between July and August in 1995 were about 5$^{\circ}C$ lower than those in 1993 and 1995. Coefficients of variation (CV) of water temperature showed the lowest value during July ~ September in 1993, however, the highest value was observed in July and August in 1994. Catch per unit effort (CPUE ; kg/angling) showed a peak with 73.7kg in 1993 when the CV was low. On the other hand, the lowest CPUE of 39.6kg was observed in 1994 when the CV was high. It was concluded that the high stability of water temperatures and the weak strength of cold water have caused the good fishing conditions of common squid.

  • PDF

Experimental Study on Heat Transfer Performance of Absorber with Variable Plate Types

  • M.A. Sarker;Moon, C.G.;Lee, H.S.;Kim, E.P.;Yoon, J.I.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.201-212
    • /
    • 2004
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of developing high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is important to improve the performance of absorber with the larger heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which could increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, that is, horizontal tube bundle type. The size of plate absorbers were made for 0.4m$\times$0.6m and the design objective of a refrigeration capacity was 1RT. In this experiment, three kinds of plate absorbers namely flat plate, dimple plate and groove plate were used. The obtained results were less than the design objective values, that is, the refrigeration capacity was about 0.3 ~0.4RT and the overall heat transfer coefficient was 500~600 kcal/$m^2$h$^{\circ}C$ at the standard conditions.

  • PDF

A study on Improvement and Invigoration of Cooperation Charge on Conservation Ecosystem Fund (생태계보전협력금 제도 활성화를 위한 부과금 개선 방안 연구)

  • Kim, Gyung-Ho;Lee, Sang-Houck
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.6
    • /
    • pp.97-109
    • /
    • 2011
  • Korea introduced the cooperation charge on conservation of ecosystem for minimizing damage of ecosystem due to development projects and their effects and for preparing resources for natural environment conservation projects. Advanced countries have made efforts by expanding investment in natural environment conservation and restoring projects to promote prevention of global warming and improvement of biological diversity, are establishing nationwide strategies and plans. To examine the reality of projects by returns of the cooperation charge on conservation of ecosystem, microsite projects in schools and public facilities take the largest share while their project budgets are only about 100~300 KRW, relatively small, which might be attributable to budget restrictions in accordance with the calculating method of levying cooperation charge on conservation of ecosystem and problems of project proceeding in the system of returning fund for projects in general. The conclusion which this study suggests on invigoration of cooperation charge on conservation of ecosystem and its operation are as followings. First, although the cooperation charge on conservation of ecosystem has been introduced in 2001, the amount of imposition per unit area remains unchanged. It is desirable to increase the amount into $1,400KRW/m^2$ as of August, 2011 as the price index has been continuously rising for the past 10 years and the upward adjustment of imposition per unit area should be notified by the decree of the Ministry of Environment every January. Second, the ceiling amount of the cooperation charge on conservation of ecosystem should be abolished. Now the ceiling amount is defined as 1 billion KRW but it was found that there was not any ceiling amount specified according to the comparative analysis of similar systems with the Korean environmental improvement fund. The ceiling should be abolished so that medium level businesses are carried out and ecosystem recovering projects in the true sense of the word can be made smoothly. Third, weight should be introduced in calculating amounts in accordance with ecologic and economic values. Harmony between development and environment can be achieved by applying differentiated weights of constant regional coefficient by use zone and ecologic and economic values. Continuous efforts of improving cooperation charge on conservation of ecosystem should be made more than anything else so that projects by returns of cooperation charge on conservation of ecosystem get effectiveness.

Flow resistance of bottom pair trawl nets and scale effect in their model experiments (쌍끌이 기선저인망의 유수저항 특성 및 모형 실험시의 축척비 영향)

  • Kim, Dae-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.2
    • /
    • pp.203-211
    • /
    • 2015
  • The purpose of this study is to identify the flow resistance of the bottom pair trawl nets. The bottom pair trawl nets being used in fishing vessel (100G/T, 550ps) was selected as a full-scale net, and 1/10, 1/25 and 1/50 of the model nets were made. Converted into the full-scale net by Tauti's modeling rule and Kim's modeling rule, when resistance coefficient k of each net was calculated by substituting into above equation for flow resistance R and wall area of nets S values of each net ${\upsilon}$. Because resistant coefficient k decreases exponentially according as flow velocity ${\upsilon}$ increases to make $k=c{\upsilon}^{-m}$, c and m values of each net were compared. As a result, as the model was smaller, c and m values was smaller in the two rule into standard of 1/10 model value, decrease degree of 1/25 model was almost same in the two rule, decrease degree of 1/50 model was very big in Tauti's modeling rule. Therefore, in the result of experiment, because average of c and m values for similarly 1/10 and 1/25 model were given $c=4.9(kgf{\cdot}s^2/m^4)$ and m=0.45, R (kgf) of bottom pair trawl net could show $R=4.9S{\upsilon}^{1.55}$ using these values. As in the order of cod-end, wing and bag part for 1/25 and 1/50 model net were removed in turn, measured flow resistance of each, converted into the full-scale, total resistance of the net and the resistance of each part net were calculated. The resistance ratio of each part for total net was not same in 1/25 and 1/50 model each other, but average of two nets was perfectly same area ratio of each part as the wing, bag and cod-end part was 43%, 45% and 12%. However, the resistance of each part divided area of the part, calculated the resistance of per unit area, wing and bag part were not big difference each other, while the resistance of cod-end part was very large.

Sensitivity Analysis of Runoff-Quality Parameters in the Urban Basin (도시 배수유역의 유출-수질 특성인자의 민감도 분석)

  • Lee, Jong-Tae;Gang, Tae-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.1
    • /
    • pp.83-93
    • /
    • 1997
  • The purpose of the study is to analyze the sensitivity of the parameters that affect the runoff and water quality in the studied drainage basins. SWMM model is applied to the four drainage basins located at Namgazwa and Sanbon in Seoul and Gray Haven and Kings Creek in the USA. first of all, the optimum values of the parameters which have least simulation error to the observed data, are detected by iteration procedure. These are used as the standard values which are compared against the procedure. These are used as the standard values which are compared against the varied parameter values. In order to catch the effectiveness of the parameters to the computing result, the parameters are changed step by setp, and the results are compared to the standard results in flowerate and quality of the sewer. The study indicates that the discharge is greatly affected by the types of runoff surface, i.e., impervious area remarkably affects the peak flow and runoff volume while the surface storage affects the runoff volume at mild sloped basins. In addition, the major parameters affecting the pollution concentrations and loadings are the contaminant accumulation coefficient per unit area per time and the continuous dry weather days. Furthermore, the factors that affect the water quality during the initial rainfall period are the rainfall intensity, transport capacity coefficient and its power coefficient. Consequently, in order to simulate the runoff-water quality, it is needed to evaluate previous data in the research performed for the studied basins. To accurately estimated from the tributary areas and the rational computation methods of the pollutants calculation should be introduced.

  • PDF

An Experimental Study to Establish a System for Vertifying the Insulation Performance of Buildings (건축물의 단열성능 검증 시스템 구축을 위한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.203-211
    • /
    • 2021
  • Recently, the insulaton design standards for reducing the energy use of buildings have been strengthened. Althoug insulation work is the most cost-effective method for reducing the primary energy consumption per unit area of a building, there are no evaluation criteria for insulation performance at the time of construction and completion inspection. The purpose of this study is to provide objective data by establishing a standard for an analysis method and a method for easily experimenting with the exterior wall thermal transmittance of an apartment house using a thermal transmittance measuring device(TESTO 435). For the exterior wall of the test subject, the specific heat per unit area exceeded 20kJ/(m2·K), and the data at the end point suitable for ISO 9869-1 were analyzed by the average method. The measured values of the thermal transmittance for 3 consecutive days converged within +5% of the desing value, and the standard deviation of the thermal transmittance by day decreased in the order of 1-Day > 3-Day > 2-Day. The standard deviation of the thermal transmittance by time period decreased in the order of 00:00~24:00 < 19:00~07:00 < 00:00~07:00. The measured value of the thermal transmittance for the time perion of 00:00 to 07:00 per day almost coincided with an error of -3% to + 2% compare to the desing value.

Predicting Dangerous Traffic Intervals between Ships in Vessel Traffic Service Areas Using a Poisson Distribution (푸아송 분포를 이용한 해상교통관제 구역 내 선박 상호간 교통위험 상황의 발생 간격 분석에 관한 연구)

  • Park, Sang-Won;Park, Young-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.402-409
    • /
    • 2016
  • Vessel traffic servies (VTS) control movements in ports and coastal areas 24 hours a day using VHF. Thus, we were able to check ship movements and the patterns followed by VTS officers in VTS areas using VHF communication analysis. This study is intended to identify control intervals for dangerous situations and provide VTS officers with basic data and guidelines to prevent these occurrences in advance. We listened to Busan port's VHF communication for seven days and obtained risk values using the Park model with reference to controlled ships. The probability of a dangerous situation arising under a controller's watch per unit of time was confirmed to follow a Poisson distribution. As a result, for each 3.50 hours that VTS directly controls an area, (and in daytime for each 2.85 hours) a ship communicates in a VTS area every 3.84 hours, and some of there communications exceed certain risk values in VTS areas.

Mineral Chemistry and Stable Isotope Composition of Sericite from the Sangdong Sericite Mine in the Kimhae Area (김해지역 상동광상산 견운모의 광물화학 및 안전동위원소 조성)

  • Kim, Jong Dae;Moon, Hi-Soo;Jin, Sheng-Jin;Kim, In Joon
    • Economic and Environmental Geology
    • /
    • v.25 no.3
    • /
    • pp.275-282
    • /
    • 1992
  • Mineral chemistry and stable isotope compositions of sericites from the Sangdong mine in the Kimhae area, Kyungsangnamdo, were studied. The Sangdong sericite deposit occurs in rhyolitic tuff of late Cretaceous age and considers to have been fonned by the hydrothennal alteration. The sericites are classified as $2M_1$ polytype and are characterized by less celadonite substitution indicating muscovite-phengite series. Their compositions are very close to that of the ideal muscovite but net layer charge ranges 1.71~1.91 which is less than 2 per formula unit of ideal muscovite. Predominant interlayer cation is K and K/(K+Na) ratio ranges 0.91 and 0.93. ${\delta}^{18}O$ values of sericites and quartz separated from the ore range 7.70~9.07 and 8.20~10.87‰, respectively. The formation temperature of sericite can be estimated as $315{\sim}340^{\circ}C$( based on ${\delta}^{18}O$ value of sericite and ${\delta}D$ value of of Cretaceous meteoric water. Their formation temperature discrepancy between coexisting sericite and quartz indicates that they are in isotopically inequilibrium. Two types of quartz, coarse grained phenocrysts and micrcrystalline aggregates are observed and the former must have been formed during volcanic eruption and remained isotopically unexchanged during hydrothermal alteration period. ${\delta}^{14}S$ values of pyrites range 1.9~4.5‰ which is within a range of volcanogenic sulfur, indicating magmatic source.

  • PDF

Vegetation Classification, Species Diversity, and Structural Characteristics of Coniferous Forest in Baekdudaegan Protected Area, Korea (백두대간 보호지역 침엽수림의 식생분류, 종다양성 및 구조적 특성)

  • Cho, Hyun-Je;Kim, Jun-Soo;Cho, Joon-Hee;Oh, Seung-Hwan
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.4
    • /
    • pp.516-529
    • /
    • 2021
  • Coniferous forests in the Baekdudaegan protected area are gradually losing their landscape diversity and uniqueness along with their ecological stability due to changes in vegetation composition and structures caused by various disturbance factors, such as climate change, vegetation succession, and human interference. This study provides basic data for establishing a comprehensive conservation plan for coniferous forests in the Baekdudaegan protected area. We classified the vegetation unit types using the Zurich-Montpellier School of Phytosociology and two-way indicator species analysis methods and analyzed the species diversity and structural characteristics based on the vegetation information of 755 stands collected in the natural resources change survey of the Baekdudaegan mountains (2016 to 2020) by the Korea Forest Service. Therefore, the vegetation of the coniferous forests of theBaekdudaegan protected area was classified into 15 types under the vegetation unit hierarchy of two community groups, four communities, seven sub-communities, and 14 variants. Furthermore, we compared the total coverage among vegetation types, importance values, constancy classes, life-forms, and diversity indices. Additionally, the average total coverage and number of species per 100 m2 of all coniferous forests were 232% and 21 species, respectively, with the species diversity and dominance indices averaging 1.907 and 0.222, respectively.