The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Equipment Development for Inorganic-Compound Concentration Measurement in a Hydroponic Culture Solution (수경배양액 무기성분농도 측정장치 개발)

  • Heo, Jeong-Wook;Park, Kyeong-Hun;Hong, Seung-Gil;Lee, Jae-Su;Baek, Jeong-Hyun;Park, Jong-Taek;Lee, Seung-Kee
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.4
    • /
    • pp.319-326
    • /
    • 2020
  • BACKGROUND: Measurement equipment was developed for inorganic nutrient concentration inside the hydroponic culture medium with several macro- and micro compositions, and applied for measuring the compositions of conventional medium. METHODS AND RESULTS: Before the equipment development, sonicator and heater were utilized to control temperature around of the module mixing with color reagents and target samples among the inorganic compositions. The measurement module and multi-sampler were also manufactured based on the COMS (Complementary Metal-Oxide Semiconductor) and installed inside the measurement equipment. Concentration of standard solution, value measured by the equipment, standard deviation or measured average value were used for estimating the accuracy and average recall of the equipment. Yamazaki solutions with EC of 0.5, 1.5, and 2.5 dS/m were offered to confirm the equipment accuracy and standard error. CONCLUSION: It was suggested that the developed equipment could be automatically applied for measurement with accuracy of over 96% and standard errors of less than 5% on 12 macro- and micro compositions such as a NO3-N, PO43- or Fe.

Elementary Students' Epistemological Views on the Nature of Scientific Measurement (측정의 본성에 대한 초등학생들의 인식론적 견해)

  • Yang, Chan-Ho;Lee, Ji-Hyeon;Kim, Young-Hoon;Noh, Tae-Hee
    • Journal of Korean Elementary Science Education
    • /
    • v.30 no.4
    • /
    • pp.430-441
    • /
    • 2011
  • We investigated the elementary students' epistemological views on the nature of scientific measurement. The Views About Scientific Measurement (Ibrahim, 2005) was administered to 117 sixth graders. The analyses of the results indicated that there was an inconsistency in their epistemological views depending on the contexts of the measurement. They also had some difficulties in understanding a distribution of the data, which is needed to understand the necessity of repeating measurements, choosing a best representative value, and comparing data sets. They were found to have some naive views on scientific measurement which influenced negatively for fostering modern epistemological views on the nature of scientific measurement. The results suggest that the nature of scientific measurement should be emphasized explicitly in the national curriculum, and an effective method which improves elementary students' epistemological views on the nature of scientific measurement also be developed.

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

A Practical Measurement Method of the Occupied Bandwidth for 8-VSB DTV Signal Using Modified ACPR

  • Kim, Young Soo;Lee, Bong Gyou;Song, Kyeongmin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.7
    • /
    • pp.3550-3565
    • /
    • 2019
  • This paper proposes a new measurement method for the effective measurement of the 99% occupied bandwidth (OBW) at monitoring stations. Although the OBW measurement of radio signal is recommended by the International Telecommunication Union Radio (ITU-R) with several methods, there still does not exist a clear measurement recommendation or standard for terrestrial DTV signal on-air environment. Modified adjacent channel power ratio (MACPR), which can be applied to 8-VSB (Vestigial Side Band) DTV (Digital Television) signal, is herein defined to verify the results of measurements obtained using the proposed measurement method. MACPR is a proper measuring parameter for determining the measuring area of a monitoring station. From measurement results obtained in real field environment, it has been found that the OBW of 8-VSB DTV signal can be effectively measured in areas where the MACPR value is over 35 dB and when the measurements are repeated more than 600 times in the same reception site. It also has been verified that measured results are within an error range of +/-0.1% compared to results directly obtained at a transmission station. It is expected that the proposed method is able to be employed in order to determine the proper location of monitoring station and provide a reliable OBW measurement procedure for 8-VSB DTV signal on-air environment.

A Measurement Algorithm using Gray-level Thresholding in Automatic Refracto-Keratometer (그레이-레벨 한계 기법을 이용한 자동 시각 굴절력 곡률계의 측정 알고리즘)

  • Sung, Won;Park, Jong-Won
    • The KIPS Transactions:PartB
    • /
    • v.9B no.6
    • /
    • pp.727-734
    • /
    • 2002
  • Currently. people become interested in the development of measuring instrument related to eyesight. In this study, we developed software of electronic part in automatic refracto-keratometer. If an automatic system, which uses images from an optical instrument, can inform the in-spector of an accurate eyesight measured value after the internal process, the frequency of mistakenly observed value will be reduced considerably. This software is using morphological filtering and gray-level signal enhancing techniques. The morphological filtering is the first process, from images of the optical instrument, to transform an original image which is hard to process into manageable one. The second process is a signal enhancing technique to the first processed image using gray -level thresholding technique and is used to reduce an error caused by the variety in distribution of the gray value of image. Therefore, this software system in electronic part will make more effective eyesight measurement by reducing the error effectively when applied to the optical image which is difficult to get accurate measurement value.

Development of Software Quality Assessment Tool (소프트웨어 품질평가 도구(ESCORT)의 설계 및 구현)

  • Yang, Hae-Sul;Gwon, Gi-Hyeon;Lee, Ha-Yong;Jo, Yeong-Sik;Lee, Yong-Geun;Park, Jeong-Ho;Heo, Tae-Gyeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.2
    • /
    • pp.185-198
    • /
    • 1995
  • The development of automated quality evaluation tool is desperately needed to decrease the cost of maintenance, to measure quality of source program in developing course for the purpose of developing high quality software. Main goal in this paper is to develop the automated tool for software quality evaluation related with high quality and high reliability of software. In this paper, we proposed the four software quality model to evaluate software quality; functional -size model, understandability model, complexity model and object-oriented model. Also, we made a scanner and a parser to analyze the c and C++ source program and to produce the metrics and function value. The measurement value is statistically analyzed for the distribution of the measurement value. we can extracted the characteristics of measurement value and this one is assisted to make scores of software quality evaluation. Finally, we made a software quality evaluation tool to support software evaluation activities.

  • PDF

The Activity Check of Brachytherapy Isotope (근접치료동위원소의 Activity Check)

  • Kim, Gun-Oh;Lee, Byung-Koo;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.21-27
    • /
    • 2004
  • An isotope Ir-192, which is used in brachytherapy depends on import in whole quantities. There are a few ways for its activity. measurement using Welltype chamber or the way to rely on authentic decay table of manufacturer. In-air dosimetry using Farmer Chamber, etc. In this paper, let me introduce the way using Farmer chamber which is easier and simple. With the Farmer chamber and source calibration jig, take a measurement the activity of an isotope Ir-192 and compare the value with the value from decay table of manufacturer and check the activity of source. The result of measurement, compared the value from decay table, by ${\pm}2.1\%$. (which belongs to recommendable value for AAPM ${\pm}5\%$ as difference of error range) It is possible to use on clinical medicine. With the increase in use of brachytherapy, the increase of import is essential. And an accurate activity check of source is compulsory. For the activity check of source, it was possible to use Farmer chamber and source calibration jig without additional purchase of Well type chamber.

  • PDF

Prolactin Monomeric Polyethylene Glycol Measurement Method and Study of Reference Value Verification

  • Dong Hyuk Ha;Hwa-Jin Ryu;Hyun-Su Cho;Sun-Young Shin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.133-136
    • /
    • 2023
  • Purpose: Prolactin in the blood is separated into three types, and over 90% of prolactin presents as a double monomer (23 KDa). Rarely, it can exist in the size of big prolactin (150 KDa), which is called macroprolactin and is known as an autoantibody complex. When macroprolactin accounts for more than 60% of prolactin in the blood, it is called macroprolactinemia. The presence of such macroprolactin was first reported in a patient with hyperprolactinemia but without typical symptoms. Macroprolactinemia is emerging as an important cause of idiopathic hyperprolactinemia. The polyethylene glycol (PEG) precipitation method using the property of precipitating large-molecular-weight proteins is simple and recently has been widely used as a screening test. The results are in good agreement with the results of gel chromatography. The purpose of this study was to confirm the measurement method and reference value verification of monomeric prolactin in blood prolactin using the PEG precipitation method. Materials and Methods: For 40 examinees who visited the Gangnam Center of Seoul National University Hospital in 2021, the prolactin level was verified using radioimmunoassay (RIA). For macroprolactinemia PEG precipitation method, 25% PEG (molecular weight 6000kDa) solution and serum were mixed in equal amounts in a test tube, then left at room temperature for 20 minutes and centrifuged at 4℃ for 30 minutes (1500g). The prolactin level was measured in the supernatant. Results : After confirming that more than 90% of the 40 tested samples within the reference range <25 ng/mL, the same value as the reference value for prolactin was applied. Since the concentration of monomeric prolactin in serum from which macroprolactin has been removed from blood is diluted 1:1 with PEG, our laboratory is currently reporting the result by multiplying the result by a dilution factor of 2. Conclusion: Radioimmunoassay using PEG precipitation method using the property of precipitating large molecular weight proteins is simple and effective for quantitative measurement of monomeric prolactin in blood prolactin.