• Title/Summary/Keyword: value measurement

Search Result 4,742, Processing Time 0.032 seconds

Application of rotating polarizer method for small cellgap measurement (회전평광법을 이용한 낮은 셀갭 측정)

  • 김창선;이기동;윤태훈;김재창
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.158-162
    • /
    • 2000
  • Measurement of low cell gap and retardation by using a rotating polarizer method was proposed. For more precise calculation and measurement, we applied a simple numerical calculation and a retardation film that has large retardation value of 1 ~m to measurement system. From experiments, we proved that cell gap and retardation could be measured even though the values of those are so small. small.

  • PDF

A COMPARATIVE STUDY ON ASSESSMENT OF CONDYLAR POSITION BY THE TMJ RADIOGRAPHY (악관절 방사선 촬영법에 따른 과두위 분석에 관한 비교 연구)

  • Lee Jin Hong;Park Chang Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.16 no.1
    • /
    • pp.81-91
    • /
    • 1986
  • The author obtained the trans cranial radiographs of right and left side and the individualized lateral tomograms of right and left side after the analysis of submental vertex view from 8 young adults of 25-32 years with normal occlusion. The condylar position from 32 radiographs of normal TMJs were assessed with each measurement methods. All datas from these analyses were recorded and statistically processed with CYBER computer system. The results were obtained as follows. 1. In each measurement methods, the area measurements using the midpoint fossa and the midpoint condyle revealed the hightest concordance rate between the radiographic pairs. 2. In the subjective evaluation, the qualitative concordance existed in 44% and the full concordance existed in 25%, so it was found that concordance rates were relatively low between the radiographic pairs. 3. In each measurement methods, the area measurement using the midpoint fossa revealed the strongest correlation between the radiographic pairs. 4. The correlations between the area measurement using the midpoint fossa and subjective valuation revealed relatively strong value which is 0.926 in the trans cranial radiographic series and the lowest value which is 0.743 in the tomographic series.

  • PDF

An Integrated Approach to Measuring Supply Chain Performance

  • Theeranuphattana, Adisak;Tang, John C.S.;Khang, Do Ba
    • Industrial Engineering and Management Systems
    • /
    • v.11 no.1
    • /
    • pp.54-69
    • /
    • 2012
  • Chan and Qi (SCM 8/3 (2003) 209) developed an innovative measurement method that aggregates performance measures in a supply chain into an overall performance index. The method is useful and makes a significant contribution to supply chain management. Nevertheless, it can be cumbersome in computation due to its highly complex algorithmic fuzzy model. In aggregating the performance information, weights used by Chan and Qi-which aim to address the imprecision of human judgments-are incompatible with weights in additive models. Furthermore, the default assumption of linearity of its scoring procedure could lead to an inaccurate assessment of the overall performance. This paper addresses these limitations by developing an alternative measurement that takes care of the above. This research integrates three different approaches to multiple criteria decision analysis (MCDA)-the multiattribute value theory (MAVT), the swing weighting method and the eigenvector procedure-to develop a comprehensive assessment of supply chain performance. One case study is presented to demonstrate the measurement of the proposed method. The performance model used in the case study relies on the Supply Chain Operations Reference (SCOR) model level 1. With this measurement method, supply chain managers can easily benchmark the performance of the whole system, and then analyze the effectiveness and efficiency of the supply chain.

A Study on the Transaction Volume Calculation model for Improving the Measurement Accuracy of Hydrogen Fuelling Station (수소충전소 계량 정확도 향상을 위한 거래량 산출 모델 연구)

  • JINYEONG CHOI;HWAYOUNG LEE;SANGSIK LIM;JAEHUN LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.692-698
    • /
    • 2022
  • With the expansion of domestic hydrogen fuelling station infrastructure, it is necessary to secure reliability among hydrogen traders, and for this, technology to accurately measure hydrogen is important. In this study, 4 types of hydrogen trading volume calculation models (model 1-4) were presented to improve the accuracy of the hydrogen trading volume. In order to obtain the reference value of model 4, and experiment was conducted using a flow rate measurement equipment, and the error rate of the calculated value for each model was compared and analyzed. As a result, model 1 had the lowest metering accuracy, model 2 had the second highest metering accuracy and model 3 had the highest metering accuracy until a certain point. But after the point, model 2 had the highest metering accuracy and model 3 had the second metering accuracy.

Cost-effective Investigation on Contaminated Land and Assessment of Measurement Uncertainty (오염토양의 효율적 조사기법과 측정불확도의 평가방법)

  • 이종천
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.49-59
    • /
    • 2004
  • The concectration and distribution of contaminants obtained from a contaminated land investigation or an environmental geochemistry survey constitutes the basis of a decision-making process on environmental policies or of scientific researches. As the quality of data determines the reliability of the result, the investigation plan should be adjusted according to the purpose of the investigation. In general, the effort to improve the data quality had been focused mainly on the QA/QC procedures in laboratories. The rapid progress of analytical instrument has also contributed toward improving the analytical precision to a sacrificable degree. Nevertheless, in many cases, it is not the analytical precision that needs improvement for the better precision of overall measurement process: it is rather during the sampling process in the field that is responsible for the poor precision. To assess the data quality on a measured value, ISO recommends to provide information on "measurement uncertainty" along with the measured value. The measurement uncertainty in an environmental measurement context can be explained as the statistical number that expresses the degree of the uncertainty stemming from the sampling and analytical procedures. There is a cost involved in order to improve the precision of sampling and analytical methods so as to decrease the degree of measurement uncertainty. The economical point of compromise in an investigation planning can be achieved when the allowable degree of uncertainty has been set before-hand. The investigation can then be planned accordingly not to exceed the uncertainty limit. Furthermore, if the measurement uncertainty estimated from the preliminary investigation can be separated into sampling and analytical uncertainties, it can be used as a criterion where the resources for the investigation should be allotted cost-effectively to reinforce the weakest link of the whole investigation process. This paper aims to present a method of estimating the level of measurement uncertainty of a measured contamination concentration at a site used as an example and to show how the estimated uncertainty can be applied to serve the particular purpose of an investigation.

Oral health and eating habits characteristics relating to maxillary central incisor color of the university students in their twenties (20대 대학생들의 상악중절치 색조와 구강보건 및 식습관 관련 특성)

  • Lee, Ji-Young;Yoon, Young-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.261-273
    • /
    • 2012
  • Objectives : This study aims to prepare the basic data of the teeth color by measuring tooth mode using the color of the maxillary central incisor of the college students in their twenties as the dental colorimeter, and oral health and eating habit characteristics were examined. Methods : The maxillary central incisor(1 teeth) of the subjects of study as 467 students(male 89, female 378) was measured during the period from November 14, December 2 2011, so the color of total 467 teeth were examined, and oral health and eating habit characteristics were researched. Results : 1. As the results of measurement of the shade, value, hue of maxillary central incisor by the general characteristics of the subject, the major(shipbuilding information, special rehabilitation for young children) was higher at 3.3 of the shade, and the grade(1), age($$\geq_-20$$), major(beauty culture & cosmetic, occupational therapy) showed higher at +2 of the value, and the grade(1) and all major showed higher at R3 of the hue. 2. As the results of measurement of the shade, value, hue of maxillary central incisor by the oral health characteristics, the subjective teeth color(yellow) and the education of oral health(no) showed higher at 2.5 of the shade. 3. As the results of measurement of the shade, value, hue of maxillary central incisor by the eating habit characteristics of the subjects, the chocolate showed higher at 3.0 and 2.0 of the shade, and the red pepper paste showed higher at +2 and STD of the value, and the green tea showed higher at $R_3$ of the hue. Conclusions : This study demonstrates that the color of the maxillary central incisor showed differences various tendency according to the oral health and eating habit characteristics.

A Study on the Measurement Methods of Plastic Strain Ratio in Automotive sheet steel (자동차용 강판의 소성변형비 측정 방법 연구)

  • 김인수;김인수
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1996.10a
    • /
    • pp.85-92
    • /
    • 1996
  • The Measurement method of the plastic strain ratio is various in Automotive sheet steel. In this paper, the measurement of the plastic strain are used two different methods, ASTM E 517 method and the automatic strain measurement tensile specimen during the tensile test, and compared the plastic strain ratios from the two methods. The experimental results showed that the measured plastic strain ratios from the automatic strain measurement method are coincide with that from the ASTM E 517 standard measurement in various specimens. Therefore, automatic strain measurement method by two extensometers shows good accuracy. Also, the strain dependance of plastic strain ratios could be recorded by the computer continuously and anisotropy of the strength coefficient, K, and strain hardening exponent, n ,could be compared with each direction automatically through the use of automatic strain measurement system.

  • PDF

Study on the Method of Diagnosing the Individuals Crop Growth Using by Multi-Spectral Images

  • Dongwon Kwon;Jaekyeong Baek;Wangyu Sang;Sungyul Chang;Jung-Il Cho;Ho-young Ban;HyeokJin Bak
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.108-108
    • /
    • 2022
  • In this study, multispectral images of wheat according to soil water state were collected, compared, and analyzed to measure the physiological response of crops to environmental stress at the individual level. CMS-V multi-spectral camera(Silios Technologies) was used for image acquisition. The camera lens consists of eight spectral bands between 550nm and 830nm. Light Reflective information collected in each band sensor and stored in digital values, and it is converted into a reflectance for calculating the vegetation index and used. According to the camera manual, the NDVI(Normalized Difference vegetation index) value was calculated using 628 nm and 752 nm bands. Image measurement was conducted under natural light conditions, and reflectance standards(Labsphere) were captured with plants for reflectance calculation. The wheat variety used Gosomil, and the wheat grown in the field was transplanted into a pot after heading date and measured. Three treatments were performed so that the soil volumetric water content of the pot was 13~17%, 20~23%, and 25%, and the growth response of wheat according to each treatment was compared using the NDVI value. In the first measurement after port transplantation, the difference in NDVI value according to treatment was not significant, but in the subsequent measurement, the NDVI value of the treatment with a water content of 13 to 17% was lowest and was the highest at 20 to 23%. The NDVI values decreased compared to the first measurement in all treatment, and the decrease was the largest at 13-17% water content and the smallest at 20-23%. Although the difference in NDVI values could be confirmed, it would be difficult to directly relate it to the water stress of plants, and further research on the response of crops to environmental stress and the analysis of multi-spectral image will be needed.

  • PDF

Revise the Value of Simulation on Thermal Performance Depending on Air-tightness Performance Classified by Opening Type of Windows (창의 개폐방식별 기밀성능에 따른 단열성능 시뮬레이션 보정치 산출)

  • Lee, Jin-Sung;Cho, Soo;Sohn, Jang-Yeul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.68-75
    • /
    • 2008
  • The purpose of this research is revise the value yield to compensate of measure the difference between computer simulation and the measurement value on the two methods which can calculates thermal performance. The way is need to understand about thermal performance, air tightness, simulations and comparisons of analysis to influence the value of each identified. The opening type of the windows and doors to be used at the analysis are T/T, L/S and SL Different condition of the windows and doors excluded except the opening type. Each of the four samples was selected by the way of opening. Result of the analysis of the difference between measurement and simulation are that T/T approach 5.3%, L/S approach 15.7%, SL approach 21% and the more air-tightness guarantees less difference of the numerical value. Each compensation value calculates by the correlation regression analysis and the air-tightness data. After the compensation of the resulting difference in T/T, L/S, SL indicate 5.4%, 2.5%, 1.0% respectively.

Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals (다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상)

  • Jung, Woon-Mo;Sim, Myeong-Heon;Jung, Sang-O;Kim, Min-Yong;Yoon, Chan-Sol;Jung, In-Chol;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.