• 제목/요약/키워드: validation.

검색결과 8,257건 처리시간 0.034초

CROSS-VALIDATION OF ARTIFICIAL NEURAL NETWORK FOR LANDSLIDE SUSCEPTIBILITY ANALYSIS: A CASE STUDY OF KOREA

  • LEE SARO;LEE MOUNG-JIN;WON JOONG-SUN
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.298-301
    • /
    • 2004
  • The aim of this study is to cross-validate of spatial probability model, artificial neural network at Boun, Korea, using a Geographic Information System (GIS). Landslide locations were identified in the Boun, Janghung and Youngin areas from interpretation of aerial photographs, field surveys, and maps of the topography, soil type, forest cover and land use were constructed to spatial data-sets. The factors that influence landslide occurrence, such as slope, aspect and curvature of topography, were calculated from the topographic database. Topographic type, texture, material, drainage and effective soil thickness were extracted from the soil database, and type, diameter, age and density of forest were extracted from the forest database. Lithology was extracted from the geological database, and land use was classified from the Landsat TM image satellite image. Landslide susceptibility was analyzed using the landslide­occurrence factors by artificial neural network model. For the validation and cross-validation, the result of the analysis was applied to each study areas. The validation and cross-validate results showed satisfactory agreement between the susceptibility map and the existing data on landslide locations.

  • PDF

Automatic RF Input Power Level Control Methodology for SAR Measurement Validation

  • Kim, Ki-Hwea;Choi, Dong-Geun;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • 제15권3호
    • /
    • pp.181-184
    • /
    • 2015
  • Evaluation of radiating radiofrequency fields from hand-held and body-mounted wireless communication devices to human bodies are conducted by measuring the specific absorption rate (SAR). The uncertainty of system validation and probe calibration in SAR measurement depend on the variation of RF power used for the validation and calibration. RF input power for system validation or probe calibration is controlled manually during the test process of the existing systems in the laboratories. Consequently, a long time is required to reach the stable power needed for testing that will cause less uncertainty. The standard uncertainty due to this power drift is typically 2.89%, which can be obtained by applying IEC 62209 in a normal operating condition. The principle of the Automatic Input Power Level Control System (AIPLC), which controls the equipment by a program that maintains a stable input power level, is suggested in this paper. The power drift is reduced to less than ${\pm}1.16dB$ by AIPLC, which reduces the standard uncertainty of power drift to 0.67%.

단순화된 패리티 공간기법을 이용한 원전 다중센서 신호검증 (Redundant Sensor Signal Validation of Nuclear Power Plants Using the Simplified Parity Space Method)

  • 오성헌;김대일;주운표;정윤형;류부형;임장현;김건중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.317-319
    • /
    • 1993
  • The function estimation characteristics of neural networks can be used for sensor signal validation of a system. In case of applying the neural networks to signal validation, it is a important problem that the redundant sensor signals used as a input signal of neural networks should be validated. In this paper, we simplify the conventional parity space method in order to input the validated signal to the neural networks and also propose the sensor signal validation method, which estimates the reliable sensor output combining neural networks with the simplified parity space method. The acceptability of the proposed signal validation method is demonstrated by using the simulation data in safety injection accident of nuclear power plants.

  • PDF

항공기 소음모델의 정합성 평가를 통한 소음지도 작성 (Noise Contour Map Designed from Validation Study of Model for Predicting Aircraft Noise)

  • 임봉빈;김주인;이규성;홍현수;김선태
    • 환경영향평가
    • /
    • 제21권6호
    • /
    • pp.893-901
    • /
    • 2012
  • Aircraft noise model such as FAA Integrated Noise Model(INM) has recently been used for forecasting the impact of noise in a residential area near an airport and quantifying the effect of various options for noise mitigation. The noise modeling should be reliable and precise in order to ensure the quality of the results provided. In this study, the validation of the noise levels simulated by the INM against measurement data recorded continuously at multiple monitoring sites was discussed. As a result of validation, the quality of the input data used as a fixed point profiles for the INM was enhanced. The noise contour maps were designed as a way to evaluate the aircraft noise of the vicinity of the airfield. The results of this study indicate that the validation of aircraft noise model by the measurement data would be required for the accurate assessment of the aircraft noise levels.

연구용 ADS-B/TIS-B Validation Testbed 설계를 위한 항공감시데이터 처리의 예비 결과 (Preliminary Results of Surveillance Data Processing for Design of Prototype ADS-B/TIS-B Validation Testbed)

  • 송재훈;오경륜;김인규;이장연
    • 한국항행학회논문지
    • /
    • 제12권6호
    • /
    • pp.539-547
    • /
    • 2008
  • 본 논문에서는 연구용 ADS-B/TIS-B Validation Testbed(AVT)설계를 위한 기초 결과에 대하여 살펴본다. ADS-B는 GNSS와 디지털 데리터링크를 활용한 새로운 항공감시 개념이다. ADS-B는 종속적인 감시 개념이기 때문에 ADS-B송수신기를 장착하지 않은 항공기에 대한 감시 정보는 획득이 불가능하다. 기존의 이차감시레이더를 사용하여 획득한 감시정보를 제공하는 개념이 AIS-B이다. AVT는 ADS-B 및 ATS-B 개념을 기반으로 한 차세대 위성항행시스템의 감시 플랫폼이라는 의의가 있다.

  • PDF

진단 전문가시스템의 개발 : 연산적 센서검증 (Development of On-Line Diagnostic Expert System Algorithmic Sensor Validation)

  • 김영진
    • 대한기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.323-338
    • /
    • 1994
  • This paper outlines a framework for performing intelligent sensor validation for a diagnostic expert system while reasoning under uncertainty. The emphasis is on the algorithmic preprocess technique. A companion paper focusses on heuristic post-processing. Sensor validation plays a vital role in the ability of the overall system to correctly detemine the state of a plant monitored by imperfect sensors. Especially, several theoretical developments were made in understanding uncertain sensory data in statistical aspect. Uncertain information in sensory values is represented through probability assignments on three discrete states, "high", "normal", and "low", and additional sensor confidence measures in Algorithmic Sv.Upper and lower warning limits are generated from the historical learning sets, which represents the borderlines for heat rate degradation generated in the Algorithmic SV initiates a historic data base for better reference in future use. All the information generated in the Algorithmic SV initiate a session to differentiate the sensor fault from the process fault and to make an inference on the system performance. This framework for a diagnostic expert system with sensor validation and reasonig under uncertainty applies in HEATXPRT$^{TM}$, a data-driven on-line expert system for diagnosing heat rate degradation problems in fossil power plants.

XML 데이타 갱신에 대한 효율적인 유효 검증 기법 (An Efficient Validation Method for XML Data Updates)

  • 이지현;박명제;정진완
    • 한국정보과학회논문지:데이타베이스
    • /
    • 제34권2호
    • /
    • pp.153-165
    • /
    • 2007
  • XML은 웹 데이타 표현 및 교환을 위한 표준으로 많은 응용 분야에서 널리 이용되고 있다. XML Schema는 표준 XML 스키마로, 정의된 XML Schema에 의거하여 작성된 XML 문서를 ‘유효한 XML 문서’라고 하며 이러한 XML 문서는 갱신이 된 후에도 XML Schema에 대해 유효함이 보장되어야 한다. 본 논문은 갱신 이전에 갱신과 관련된 부분에 대한 유효 검증을 수행하여 불필요한 유효 검증을 제거한 XML Schema 유효 검증 메커니즘인 ‘예상 갱신 부분 유효 검증 기법’과 갱신 별 유효 검증 알고리즘을 제안한다. 또한 XML 데이타와 XML Schema 간의 매핑 방법과 XML Schema 유효 검증을 지원하기 위해 효율적인 스키마 정보 추출을 제공하는 XML Schema 저장 방법을 제안한다. 마지막으로 실험을 통해 스키마 저장 방법에 따른 갱신 별 유효 검증 성능을 비교한다.

고차원 (유전자 발현) 자료에 대한 군집 타당성분석 기법의 성능 비교 (Comparison of the Cluster Validation Methods for High-dimensional (Gene Expression) Data)

  • 정윤경;백장선
    • 응용통계연구
    • /
    • 제20권1호
    • /
    • pp.167-181
    • /
    • 2007
  • 유전자 발현 자료(gene expression data)는 전형적인 고차원 자료이며, 이를 분석하기 위한 여러 가지 군집 알고리즘(clustering algorithm)과 군집 결과들을 검증하는 군집타당성분석 기법(cluster validation technique)이 제안되고 있지만, 이들 군집 타당성을 분석하는 기법의 성능에 대한 비교, 평가는 매우 드물다. 본 논문에서는 저차원의 모의실험 자료와 실제 유전자 발현 자료에 대하여 군집 타당성분석 기법들의 성능을 비교하였으며, 그 결과 내적 측도에서는 Dunn 지수, Silhouette 지수 순으로 뛰어났고 외적 측도에서는 Jaccard 지수가 성능이 가장 우수한 것으로 평가되었다.

항-보호항원 항체의 역가 측정을 위한 효소면역측정법 밸리데이션 (ELISA Validation for anti-PA Antibody Titer Measurements)

  • 김유진
    • 한국군사과학기술학회지
    • /
    • 제13권3호
    • /
    • pp.478-485
    • /
    • 2010
  • The vaccine is biological pretreatment that improves immunity to a particular disease. We can get immunity from producing antibody with injection antigen which has ability to defense against the disease. The ELISA is the most widely used method to measure antibody titer. We have developed and performed validation of ELISA according to the guideline of KFDA and ICH. In this paper, we have verified ELISA method is an excellent method to measure the titer of anti-PA antibody. We have constructed recombinant protective antigen among anthrax toxins and used as antigen of ELISA. In this validation, we have evaluated precision (repeatability, interlaboratory precision), specificity, linearity(range) and LOD, which are validation articles suggested by guideline. Inter-person precision was replaced with inter-laboratory precision. From the results, we have confirmed high precision in all experiments with CV under 20%.

HSPF를 이용한 임하호 유역 유사량 모의 (Simulation of Sediment Yield from Imha Watershed Using HSPF)

  • 전지홍
    • 한국농공학회논문집
    • /
    • 제52권6호
    • /
    • pp.39-48
    • /
    • 2010
  • Sediment yields from Imha watershed were simulated during 1993-2008 using Hydrologic Simulation Program-Fortran (HSPF). Using observed daily stream flow for 2004-2008 and hourly suspended solid concentration for three events during 2006, HSPF was calibrated and validated at the sites of Imha and Youngyang for stream flow and Dongchun and Jangpachun for sediment yield. The calibration and validation results represented high model efficiency for simulating daily stream flow and hourly suspended solid. The determination coefficients of calibration and validation were 0.90 and 0.81 for daily stream flow, and 0.91 and 0.86 for monthly stream flow, respectively. Based on model tolerances for calibration and validation of stream flow, HSPF performance for simulating stream flow represented 'very good'. The determination coefficients of calibration and validation were 0.94-0.96 and 0.95 for hourly sediment yields, respectively. The average yearly sediment yield during 1993-2008 was 122,290 ton/year and most of sediment yield (77 % of total yield) were generated from June to August. The calibrated HSPF simulated well the movement of water and eroded soil within Imha watershed.