• Title/Summary/Keyword: validation range

Search Result 723, Processing Time 0.03 seconds

Validation of Simultaneous Analysis Method of Standard Compounds in Fermented Kalopanax pictus Nakai by Bioconversion (생물전환을 통한 음나무발효물의 지표성분 설정 및 동시분석법 검증)

  • Jang, Won Hui;Lee, Wha Young;Lee, Bong Jin;Kim, Jean Man;Park, Seon Ju
    • The Korean Journal of Food And Nutrition
    • /
    • v.32 no.2
    • /
    • pp.148-154
    • /
    • 2019
  • The aim of this study was to select compounds for the standardization of fermented Kalopanax pictus Nakai (KP-F), to develop the analysis method using HPLC-PDA and to perform method validation. KP-F is a fermented powder developed to improve the original physiological activities and create a new functionality. Eleutheroside E, Acanthoside B, and Syringaresinol were selected as the standard compounds and developed our own method for simultaneous analysis. The analyte was isolated using C18 column with a gradient elution of 0.05 M phosphoric acid in water and methanol as the mobile phase at a flow rate of 1 mL/min and detected at 210 nm. As a result, all standard compounds showed good linearity with an $R^2$ (coefficient of correlation) of 1.000 and for the limit of detection range of $0.710{\sim}0.831{\mu}g/mL$, and the limit of quantification as $2.150{\sim}2.520{\mu}g/mL$. The precision was RSD (%) of less than 4.80%, while the accuracy was 4.70%>RSD (%) for the range 102.44~110.48%. In conclusion, the developed analysis method is suitable for the detection of Eleutheroside E, Acanthoside B, and Syringaresinol in KP-F.

The effect of noise and doppler for range measurement of low orbit satellite using tone method (톤 방식을 사용한 저궤도 위성 거리 측정에서의 잡음과 도플러 영향 분석)

  • 김영완;박동철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.641-650
    • /
    • 2000
  • The effects of noise and doppler for low orbit satellite range measurement using tone method are represented in this paper. Also the optimal noise bandwidth of range signal detection circuit which is used for range measurement system of KOMPSAT is proposed. Based on the effects of satellite orbit parameters via the deduction of dynamic motion characteristics of low orbit satellite and signal to noise spectral density of range measurement signal, the effects of noise and doppler for range measurement system are analyzed. The effect of satellite link noise is decreased, but the effect for doppler is increased as the PLL noise bandwidth of range signal detection circuit is increased. The validation of analyzed effect is verified via comparison of measurement results of KOMPSAT's range measurement system and simulation results in environments of low orbit satellite.

  • PDF

Stellar Source Selections for Image Validation of Earth Observation Satellite

  • Yu, Ji-Woong;Park, Sang-Young;Lim, Dong-Wook;Lee, Dong-Han;Sohn, Young-Jong
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.4
    • /
    • pp.273-284
    • /
    • 2011
  • A method of stellar source selection for validating the quality of image is investigated for a low Earth orbit optical remote sensing satellite. Image performance of the optical payload needs to be validated after its launch into orbit. The stellar sources are ideal source points that can be used to validate the quality of optical images. For the image validation, stellar sources should be the brightest as possible in the charge-coupled device dynamic range. The time delayed and integration technique, which is used to observe the ground, is also performed to observe the selected stars. The relations between the incident radiance at aperture and V magnitude of a star are established using Gunn & Stryker's star catalogue of spectrum. Applying this result, an appropriate image performance index is determined, and suitable stars and areas of the sky scene are selected for the optical payload on a remote sensing satellite to observe. The result of this research can be utilized to validate the quality of optical payload of a satellite in orbit.

IRF-k kriging of electrical resistivity data for estimating the extent of saltwater intrusion in a coastal aquifer system

  • Shim B. O.;Chung S. Y.;Kim H. J.;Sung I. H.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.352-361
    • /
    • 2003
  • We have evaluated the extent of saltwater intrusion from electrical resistivity distribution in a coastal aquifer system in the southeastern part of Busan, Korea. This aquifer system is divided into four layers according to the hydrogeologic characteristics and the horizontal extent of intruded saltwater is determined at each layer through the geostatistical interpretation of electrical resistivity data. In order to define the statistical structure of electrical resistivity data, variogram analysis is carried out to obtain best generalized covariance models. IRF-k (intrinsic random function of order k) kriging is performed with covariance models to produce the plane of spatial mean resistivities. The kriged estimates are evaluated by cross validation to show a good agreement with the true values and the statistics of cross validation represented low errors for the estimates. In the resistivity contour maps more than 5 m below the surface, we can see a dominant direction of saltwater intrusion beginning from the east side. The area of saltwater intrusion increases with depth. The northeast side has low resistivities less than 5 ohm-m due to the presence of saline water in the depth range of 20 m through 70 m. These results show that the application of geostatistical technique to electrical resistivity data is useful for assessing saltwater intrusion in a coastal aquifer system.

  • PDF

Studies on 5 Protein Fractions Prediction of Forage Legume Mixture by NIRS

  • Lee, Hyo-Won;Jang, Sungkwon;Lee, Hyo-Jin;Park, Hyung-Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.34 no.3
    • /
    • pp.214-218
    • /
    • 2014
  • This study was conducted to assess the feasibility of near-infrared reflectance spectroscopy (NIRS) as a rapid and reliable method for the estimation of crude protein (CP) fractions in forage legume mixtures (sudangrass and pea mixture, and kidney bean and potato mixture). A total of 178 samples were collected and their spectral reflectance obtained in the range of 400~2,500 nm. Of these, 50 samples were selected for calibration and validation, and 35 samples were used for calibration of the data set, and the modified partial least square regression (MPLSR) analysis was performed. The correlation coefficient ($r^2$) and the standard error of cross-validation (SECV) of the calibration models in the CP fractions, A, B1, B2, B3, and C, were 0.94 (1.05), 0.92 (0.74), 0.96 (0.95), 0.91 (0.42), and 0.83 (0.38), respectively. Fifteen samples were used for equation validation, and the $r^2$ and the standard error of prediction (SEP) were 0.87 (1.45), 0.91 (0.49), 0.94 (1.13), 0.36 (0.96), and 0.74 (0.67), respectively. This study showed that NIRS could be an effective tool for the rapid and precise estimation of CP fractions in forage legume mixtures.

Quantification of Naproxen in Pharmaceutical Formulation using Near-Infrared Spectrometry (근적외 분광분석법을 이용한 나프록센 정제의 정량분석)

  • Kim Do Hyung;Woo Young Ah;Kim Hyo Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • Near-infrared (NIR) spectroscopy has been widely applied in various field, since it is nondestructive and no sample preparation is required. In this paper, NIR spectroscopy was used for the determination of naproxen in a commercial pharmaceutical preparation. NIR spectroscopy was used to determine the content of naproxen in intact naproxen tablets containing 250 mg ($65.8\%$ nominal concentration) by collecting NIR spectra in the range of $1100{\sim}1750nm$. The laboratory-made samples had $46.1{\sim}85.5\%$ nominal naproxen concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR). Model validation was performed by randomly splitting the data set into calibration and validation data set (63 samples as a calibration data set and 42 samples as a validation data set). The developed NIR calibration gave results comparable to the known values of tablets in a laboratorial manufacturing process with standard error of calibration (SEC) and standard error of prediction (SEP) of $1.06\%\;and\;1.04\%$, respectively. The NIR method showed good accuracy and repeatability. NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Determination of Seed Lipid and Protein Contents in Perilla and Peanut by Near-Infrared Reflectance Spectroscopy

  • Oh, Ki-Won;Choung, Myoung-Gyun;Pae, Suk-Bok;Jung, Chan-Sik;Kim, Byung-Joo;Kwon, Yil-Chan;Kim, Jung-Tae;Kwack, Yong-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.45 no.5
    • /
    • pp.339-342
    • /
    • 2000
  • Near-infrared reflectance spectroscopy (NIRS) was used to estimate the lipid and protein contents in ground seed samples of perilla (Perilla frutescens Brit.) and peanut (Arachis hypogaea L.). A total of 46 perilla and 80 peanut calibration samples and 23 perilla and 46 pea. nut NIRS validation samples were used for NIRS equation development and validation, respectively. Validation of these NIRS equations showed a range of very low bias (-0.05 to 0.13 %) and standard error of prediction corrected for bias (0.224 to 0.803%) and very high coefficient of determination ($R^2$) (0.962 to 0.985). It was concluded that NIRS could be adapted as a mass screening method for lipid and protein contents in perilla and peanut seed.

  • PDF

Automatic Creation of SHACL Schemas for Validation of RDF Knowledge Graph Structures Based on RML Mappings

  • Choi, Ji-Woong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.9
    • /
    • pp.77-89
    • /
    • 2022
  • In this paper, we propose a system which automatically generates SHACL schemas to describe and validate RDF knowledge graphs constructed by RML mappings. Unlike existing studies, the proposed system generates the schemas based on not only RML mapping rules but also metadata extracted from RML mapping input data in various formats such as CSV, JSON, XML or databases. Therefore, our schemas include the constraints on data type, string length, value range and cardinality, which were not present in the existing schemas. And we solves the problem with "repeated properties" which overlooked in existing studies. Through a conformance test consisting of 297 cases, we show that the proposed system generates correct constraints for the graphs. The proposed system can contribute to automation of the tedious and error-prone existing manual validation processes.

Validation, Measurement Uncertainty, and Determination of Bixin and Norbixin in Processed Foods of Animal Resources Distributed in Korea

  • Ga-Yeong Lee;Choong-In Yun;Juhee Cho;Young-Jun Kim
    • Food Science of Animal Resources
    • /
    • v.43 no.6
    • /
    • pp.949-960
    • /
    • 2023
  • This research aimed to validate a high-performance liquid chromatography method for the quantitative determination of bixin and norbixin in various foods. The Diode Array Detector (495 nm) technique was used. Method was validated for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. The calibration curve showed excellent linearity (r2≥0.9999) over the tested concentration range of 0.2-25 mg/L. The LOD and LOQ were 0.03-0.11 and 0.02-0.05 mg/L for bixin and norbixin, respectively. The intra-and inter-day accuracies and precisions were 88.0±1.3-97.0±0.5% and 0.2%-2.6% relative SD (RSD) for bixin and 88.2±0.8-105.8±0.8% and 0.3%-2.7% RSD for norbixin, respectively. Inter-laboratory validation for accuracy and precision was conducted in three laboratories, and these results all met the AOAC guidelines. In addition, the relative expanded uncertainty (<22%) satisfied the CODEX recommendation. Furthermore, products distributed in Korea were monitored for annatto extracts using the proposed method to demonstrate its application. The developed analytical method is reliable for quantifying bixin and norbixin in various foods.

Validation Experiments for a Holographic Particle Velocimetry System (펄스 홀로그래프를 이용한 입자 속도 측정 시스템의 검증 실험)

  • Oh, Dai-Jin;Choo, Yeon-Jun;Kang, Bo-Seon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.714-719
    • /
    • 2001
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this research, the optical system for double pulse holographic recording and reconstruction of particle images was developed. Validation experiments for the developed system were conducted measuring the velocities of glass beads on a rotating disk. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitude. The measurement results of distance between glass beads, size, and velocities of them using holographic method compared reasonalbly well with the known values within acceptable range of errors.

  • PDF