• Title/Summary/Keyword: validation range

Search Result 723, Processing Time 0.024 seconds

Antenna for EMI Site Validation above 1 GHz (1 GHz 이상의 EMI 시험장 적합성 평가용 안테나)

  • Kong, Sung-Sik;Chung, Sam-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.65-66
    • /
    • 2006
  • In this paper, we designed and fabricated a broadband antenna for EMI site validation above 1 GHz. To develop the antenna which is satisfied omni-directional radiation pattern and broadband characteristics required by CISPR, we designed biconical type with cylindrical load. The developed antenna has good characteristics of the radiation patterns and VSWR<2 the frequency range from 1 GHz to 18 GHz.

  • PDF

Development of the Algorithm for Optimizing Wavelength Selection in Multiple Linear Regression

  • Hoeil Chung
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • A convenient algorithm for optimizing wavelength selection in multiple linear regression (MLR) has been developed. MOP (MLP Optimization Program) has been developed to test all possible MLR calibration models in a given spectral range and finally find an optimal MLR model with external validation capability. MOP generates all calibration models from all possible combinations of wavelength, and simultaneously calculates SEC (Standard Error of Calibration) and SEV (Standard Error of Validation) by predicting samples in a validation data set. Finally, with determined SEC and SEV, it calculates another parameter called SAD (Sum of SEC, SEV, and Absolute Difference between SEC and SEV: sum(SEC+SEV+Abs(SEC-SEV)). SAD is an useful parameter to find an optimal calibration model without over-fitting by simultaneously evaluating SEC, SEV, and difference of error between calibration and validation. The calibration model corresponding to the smallest SAD value is chosen as an optimum because the errors in both calibration and validation are minimal as well as similar in scale. To evaluate the capability of MOP, the determination of benzene content in unleaded gasoline has been examined. MOP successfully found the optimal calibration model and showed the better calibration and independent prediction performance compared to conventional MLR calibration.

ELISA Validation for anti-PA Antibody Titer Measurements (항-보호항원 항체의 역가 측정을 위한 효소면역측정법 밸리데이션)

  • Kim, Yu-Gene
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.478-485
    • /
    • 2010
  • The vaccine is biological pretreatment that improves immunity to a particular disease. We can get immunity from producing antibody with injection antigen which has ability to defense against the disease. The ELISA is the most widely used method to measure antibody titer. We have developed and performed validation of ELISA according to the guideline of KFDA and ICH. In this paper, we have verified ELISA method is an excellent method to measure the titer of anti-PA antibody. We have constructed recombinant protective antigen among anthrax toxins and used as antigen of ELISA. In this validation, we have evaluated precision (repeatability, interlaboratory precision), specificity, linearity(range) and LOD, which are validation articles suggested by guideline. Inter-person precision was replaced with inter-laboratory precision. From the results, we have confirmed high precision in all experiments with CV under 20%.

Prediction of Soluble Solids Content of Chestnut using VIS/NIR Spectroscopy

  • Park, Soo Hyun;Lim, Ki Taek;Lee, Hoyoung;Lee, Soo Hee;Noh, Sang Ha
    • Journal of Biosystems Engineering
    • /
    • v.38 no.3
    • /
    • pp.185-191
    • /
    • 2013
  • Purpose: The present study focused on the estimation of soluble solids content (SSC) of chestnut using reflectance and transmittance spectra in range of VIS/NIR. Methods: Four species intact/peeled chestnuts were used for acquisition of spectral data. Transmittance and reflectance spectra were used to develop the best PLS model to estimate SSC of chestnut. Results: The model developed with the transmitted energy spectra of peeled chestnuts rather than intact chestnuts and with range of NIR rather than VIS performed better. The best $R^2$ and RMSEP of cross validation were represented as 0.54 and $1.85^{\circ}Brix$. The results presented that the reflectance spectra of peeled chestnuts by species showed the best performance to predict SSC of chestnut. $R^2$ and RMSEP were 0.55 and $1.67^{\circ}Brix$. Conclusions: All developed models showed RMSEP around $1.44{\sim}2.54^{\circ}Brix$, which is considered not enough to estimate SSC accurately. It was noted that $R^2$ of cross validation that we found were not high. For all that, grading of the fruits in two or three classes of SSC during postharvest handling seems possible with an inexpensive spectrophotometer. Furthermore, the development of estimation of SSC by each chestnut species could be considered in that SSC distribution is clustering in different range by species.

Deformable image registration in radiation therapy

  • Oh, Seungjong;Kim, Siyong
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.101-111
    • /
    • 2017
  • The number of imaging data sets has significantly increased during radiation treatment after introducing a diverse range of advanced techniques into the field of radiation oncology. As a consequence, there have been many studies proposing meaningful applications of imaging data set use. These applications commonly require a method to align the data sets at a reference. Deformable image registration (DIR) is a process which satisfies this requirement by locally registering image data sets into a reference image set. DIR identifies the spatial correspondence in order to minimize the differences between two or among multiple sets of images. This article describes clinical applications, validation, and algorithms of DIR techniques. Applications of DIR in radiation treatment include dose accumulation, mathematical modeling, automatic segmentation, and functional imaging. Validation methods discussed are based on anatomical landmarks, physical phantoms, digital phantoms, and per application purpose. DIR algorithms are also briefly reviewed with respect to two algorithmic components: similarity index and deformation models.

Development and Validation of Korean Sleep Scale A (수면측정 도구의 개발을 위한 연구)

  • 오진주;송미순;김신미
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.3
    • /
    • pp.563-572
    • /
    • 1998
  • The purpose of study was to develop and validate Korean Sleep Scale A which can be easily administrated by nurses for a wide range of adult subjects. Dimensions of sleep concept were derived by literature review. Previously developed sleep sclaes were also analyzed in order to develop scale items. The Korean sleep scale A was structured as a 15 item, 4 point likert type scale. The Scale was tested an 298 female and male adult subjects after pilottest and content validation. The results showed reliability by internal consistency of Cronbach's α=.75 Construct validity was tested by factor analysis and known group technique. Factor analysis showed 4 factors-sleep pattern, sleep evaluation, sleep result, and cause of sleep disturbance. These four factors explained 55.9% of total variance. Correlations between factors ranged from .15-.32. There was correlation among Korean Sleep ScaleA score, Verran and Snyder-Halpern(VSH) Sleep Scale score, and sleep satisfaction scale score, r=.71(p=.00), r=.51(p=.03), respectively, These study results partially support reliability, construct validity, and criterion related validity of Korean Sleep Scale A. Further validation study is required with other subjects and other settings.

  • PDF

New Method for Measurement and Validation of In-situ Sound Transmission Loss (In-situ 소음투과손실 측정 및 검증을 위한 기법 개발)

  • Lee, Hwa-Soo;Park, Hong-Cheol;Yoon, Seong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.795-800
    • /
    • 2008
  • The sound transmission loss is a key index to evaluate the acoustic performance of a car-body structure at the high frequency range. From this paper, a new validation method for in-situ sound transmission loss is proposed. First, in-situ sound transmission loss is measured by using PU intensity probe on the condition of complete vehicle. Second, validation test, which is consisted of internal, external and total frequency response function test, is performed by using volume acceleration source and microphones. Then, these test results are compared to validate the accuracy of in-situ sound transmission loss. Finally, the test result of in-site method is compared with results of two reverberant room test method and SEA analytical method. The reliability of in-situ method is confirmed by these procedures.

  • PDF

Parity Space and Pattern Recognition Approach for Hardware Redundant System Signal Validation using Artificial Neural Networks (인공신경망을 이용하여 하드웨어 다중 센서 신호 검증을 위한 패리티 공간 및 패턴인식 방법)

  • 윤태섭
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.6
    • /
    • pp.765-771
    • /
    • 1998
  • An artificial neural network(NN) technique is developed for hardware redundant sensor validation. Since the measurement space is a continuous space with many operating regions, it is difficult to train a NN to correctly detect failure in an accurate measurement system. A conventional backpropagation NN is modified to include an additional preprocessing layer that extracts classification features from scalar measurements. This feature extraction means transform the measurement space to parity space. The NN is independent of the state variable being measured, the instrument range, and the signal tolerance. This NN resembles the parity space approach to signal validation, except that analytical parity equations are unneeded and the NN pattern recognition capability is utilized for decision making.

  • PDF

On the use of numerical models for validation of high frequency based damage detection methodologies

  • Aguirre, Diego A.;Montejo, Luis A.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.4
    • /
    • pp.383-397
    • /
    • 2015
  • This article identifies and addresses current limitations on the use of numerical models for validation and/or calibration of damage detection methodologies that are based on the analysis of the high frequency response of the structure to identify the occurrence of abrupt anomalies. Distributed-plasticity non-linear fiber-based models in combination with experimental data from a full-scale reinforced concrete column test are used to point out current modeling techniques limitations. It was found that the numerical model was capable of reproducing the global and local response of the structure at a wide range of inelastic demands, including the occurrences of rebar ruptures. However, when abrupt sudden damage occurs, like rebar fracture, a high frequency pulse is detected in the accelerations recorded in the structure that the numerical model is incapable of reproducing. Since the occurrence of such pulse is fundamental on the detection of damage, it is proposed to add this effect to the simulated response before it is used for validation purposes.

Nondestructive Quantification of Intact Ambroxol Tablet using Near-infrared Spectroscopy (근적외분광분석법을 사용한 암브록솔 정제의 비파괴적 정량분석)

  • 임현량;우영아;김도형;김효진;강신정;최현철;최한곤
    • YAKHAK HOEJI
    • /
    • v.48 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • Near-infrared (NIR) spectroscopy was used to determine rapidly and nondestructively the content of ambroxol in intact ambroxol tablets containing 30 mg (12.5% m/m nominal concentration) by collecting NIR spectra in range 1100-1750 nm. The laboratory-made samples had 10.3∼15.9% m/m nominal ambroxol concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR) with autoscaling. Model validation was performed by randomly splitting the data set into calibration and validation data set (7 samples as a calibration data set and 5 samples as a validation data set). The developed NIR method gave results comparable to the known values of tablets in a laboratorial manufacturing Process, standard error of calibration (SEC) and standard error of prediction (SEP) being 0.49% and 0.49% m/m respectively. The method showed good accuracy and repeatability NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.