• Title/Summary/Keyword: vacuum tube

Search Result 236, Processing Time 0.031 seconds

The Characteristics of Ozone Generation Synergy Effect for 3 Electrode-1 Discharge Gap Silent Discharge Type Ozonizer using Frequency-Vacuum (주파수-진공도를 이용한 3전극-1방전간극 무성방전형 오존발생기의 오존생성 상승 효과 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.94-101
    • /
    • 2005
  • The silent discharge type ozonizer with three electrodes(central electrode, internal electrode, and external electrode) and one discharge gap(discharge gap between internal electrode and external electrode) has been designed and manufactured. It is a silent discharge type ozonizer for which the AC high frequency voltages applied to the central electrode within vacuum discharge tube and the internal electrode for which the external electrode is a ground Ozone is generated by silent discharge in discharge gap. At the moment, discharge characteristics and ozone generation characteristics were investigated in accordance with vacuum of discharge tube, frequency of AC power source, discharge power of ozonizer, and quantity of supplied oxygen gas. In consequence, ozone characteristics proportional to vacuum of discharge tube and frequency of AC power source. The maximum value of ozone can be obtained 7,700[ppm], 460[mg/h] and 70[g/kwh].

Discharge Phenomena of Glass Tube Vacuum under AC Applied Voltage (AC 전압하에서 유리진공관의 방전현상)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.371-372
    • /
    • 2008
  • In this paper, we experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and $SF_6$. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We also revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF

Compact Anode Design with the Heat Capacity Performance in Rotating Anode X-ray Tube for Digital Radiography

  • Lee, Seok Moon
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2015
  • We studied the compact anode design to develop 100 kW rotating anode X-ray tube with large focal spot 1.2 mm, small focal spot 0.6 mm and tube voltage 150 kV for large hospital digital radiography using computer thermal simulation. The larger thermal radiation effect in a high vacuum can reduce the temperature of anode so the method to increase the surface area of anode is investigated. The anode has the multi-tier shape at the back side of TZM body of anode and also bigger diameter of anode. The number of multi-tiers was varied from 6 to 15 and the diameter of anode was also varied from ${\Phi}74$ to ${\Phi}82$. From ANSYS transient thermal simulation result, we could obtain $1056.4^{\circ}C$ anode maximum temperature when applying 100 kW input power at 0.1 second on target focal track which is less than $1091^{\circ}C$ of the conventional 75 kW X-ray tube with reduced anode weight by 15.5% than the conventional anode. The compact anode of reduced anode weight is able to improve the unwanted noise when the rotor is rotating at high-speed and also reduce the rotational torque which the cost effective stator-coil is possible. It is believed that the anode with 15 ea multi-tiers using ${\Phi}82$ can satisfy with the specification of the anode heat capacity. From the results of this paper, it has been confirmed that the proposed compact anode can be used as the anode of 100 kW rotating anode X-ray tube for digital radiography.

Magnetic Interference on the Infrastructure for a Super-speed Tube Train

  • Lee, Hyung-Woo;Jang, Seung-Yup;Kang, Bu-Byoung;Cho, Su-Yeon;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.364-368
    • /
    • 2011
  • The super-speed tube train was introduced to increase the speed of ground transportation. It levitates magnetically and runs in a partial vacuum tube, which significantly reduces air resistance. However, strong magnetic force sufficient to propel the massive train can affect the infrastructure. The induced eddy current produces joule heat, and raises the inside temperature of the girder, which might lead to electrochemical corrosion on the girder, thereby weakening its durability. In this paper, the authors analyzed the magnetic flux and induced eddy current in the reinforced concrete girder by using three-dimensional FEM, particularly by varying the number of reinforcing steels of the upper flange of the girder to the condition of almost the same flexural strength and reinforcing steel amount.

Characteristics of Superposed Discharge type Ozonizer by Variation of Inner Dielectric Vacuum

  • Chun, Byung-Joon;Lee, Kwang-Sik;Song, Hyun-Jig
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.230-235
    • /
    • 2003
  • In this paper, a superposed discharge type ozonizer with an internal dielectric that can be made into a vacuum tube has been designed and fabricated. Ozone generation and discharge characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of inside internal dielectric. Pure oxygen was used as the supply gas of the ozonizer. Ozone concentration and ozone generation are gradually increased when discharge power is increased at the same flow-rate and they are both proportional to the vacuum level. As such, the maximum ozone concentration of 8840 ppm was obtained at vacuum 0.1 Torr and flow-rate 0.5 $\ell$/min.

Analysis of a Spun-CNT Based X-ray Source

  • Kim, Hyun Suk;Castro, Edward Joseph D.;Hun, Choong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.639-639
    • /
    • 2013
  • In this research we report the significant contribution of the as-spun multi-walled carbon nanotube (MWCNT) on the x-ray images formation using a low tube voltage x-ray source. The MWCNT, which was used for the fabrication of the spun CNT, was grown using a microwave plasma-enhanced chemical vapor deposition machine. Electrical-optics simulation software was utilized to determine the electron field emission trajectory of the triode-structure-as-spun CNT-based x-ray source. It was shown that a significant amount of converging electrons hit the target anode producing a clear x-ray image. These x-ray images where produced at a small amount of anode current of 0.67 mA at a tube voltage of 5 kV with the gate voltage of 0 V. Also, comparisons of the radiographs at various exposure times of the sample where analyzed with and without an x-ray dose filter. Results showed that spatially-resolved images were formed using the as-spun CNT at a low tube voltage with a $54-{\mu}m$ Al x-ray filter. This study can be used for low-voltage medical applications.

  • PDF

Gas flow pattern through a long round tube of a gas fueling system (I) (기체연료주입계의 긴 원형도관에서 기체 흐름의 유형)

  • IN, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.465-474
    • /
    • 2006
  • A gas fueling system composed of a gas reservoir, an on-off valve, and a gas transferring tube, which is the simplest construction for the pre-programmed gas puffing, was simulated by numerically solving the time-dependent one-dimensional gas flow equation. The purpose of the simulation is to establish the relationship between the gas flow pattern (the elapsed time to the maximum flow, the maximum flow rate, the gas pulse duration) and the system parameters (the filling pressure and the volume of the gas reservoir, and the length and the diameter of the gas transferring tube).

Manufacturing Technique and Material Properties for 1/5-Scale Reinforced Concrete Frame Model (1/5 축소 3층 철근콘크리트 골조 모델의 제작기법 및 재료특성 연구)

  • 이한선;우성우;고동우;허윤섭;강귀용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.575-580
    • /
    • 1997
  • This study presents the techniques to manufacture the model concrete and model reinforcement for the 1/5-scale 3-story reinforced concrete frame. The used model concrete has sufficient workability but shows a little lower strength than expected model steel was made of commercial $\phi$3.2mm and $\phi$2.0mm wire by using deforming device and vacuum tube electric furnace. The yield strength can be simulated but it was difficult to simulate the other properties. The load cell was specially manufactured to measure the shear force in the columns of the first story. The carrying frame and the hinge adapter of artificial mass are explained. The special problems in the process of construction of model are also dressed.

  • PDF

Gas Flow Pattern Through a Long Round Tube of a Gas Fueling System (II) (기체연료주입계의 긴 원형도관에서 기체 흐름의 유형 (2))

  • In, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.594-604
    • /
    • 2006
  • Gas fueling systems operated in the mode of a fixed valve opening at a constant line pressure, and the mode of a constant inlet flow are simulated to establish the relationships between the gas flow pattern and the tube dimensions under various system conditions.