• 제목/요약/키워드: vacuum equipment

검색결과 229건 처리시간 0.025초

육상 및 해양 시추용 디개서 시스템의 진공펌프 성능해석 (A Study on the Performance Analysis of Degasser System with Vacuum Pump for Onshore and Offshore Drilling)

  • 권성용;박성규;신철순;김승찬;임희연
    • 한국산업융합학회 논문집
    • /
    • 제25권6_2호
    • /
    • pp.1063-1069
    • /
    • 2022
  • In modern industry, vacuum has grown into an indispensable industrial field. The performance of the vacuum pump in the degasser system among mud treatment system facilities was verified by a numerical analysis method. The degasser system is an equipment for removing the gas contained in the mud, and it is a work process that requires a vacuum. This study analyzed the vacuum pump performance of the degasser used in drilling for resource development of onshore and offshore plants. The vacuum pump used in the degasser system was designed with a discharge rate of 0.099kg/s. The DM(Design Modeler) program of ansys workbench 17.2 was used to modify the model of the vacuum pump used in the degasser system. And for performance analysis, CFX, which is known to be suitable for rotating system analysis, was used. Finally the performance analysis results of the vacuum pump and the prototype performance test results were compared and analyzed.

공압 진공장치 설계를 위한 전문가 시스템 개발에 관한 연구 (A Study on the Development of Expert System for Pneumatic Vacuum Equipment Design)

  • 신흥열;김준식;이재원
    • 한국정밀공학회지
    • /
    • 제14권4호
    • /
    • pp.15-21
    • /
    • 1997
  • Pneumatics is widly used in the industrial implementation, in the operation of air-powered actuators and the control devices needed in their operation. However, there are many empirical factors in pneumatics design, it might cause excessive design of pneumatic components. For that reason, we developed VDES(Vacuum Design Expert System) for the economic design of pneumatic vacuum equipment. VDES is achieved with CLIPS(C Language Integrated Production System) and knowledge base that contains a number of facts and rules for pneumatic vacuum design. Forward chaining and depth first search technique are used in this system. Appling VDES to the actual field, this system is verified to be a good efficiency and could be applied to the field of pneumatic vacuum equipment design.

  • PDF

진공 배기 및 초음파 접합 복합기 진동자 냉각에 관한 연구 (A Study on Cooling of Piezoelectric Element of Multifunction Equipment for Vacuum Exhaust and Ultrasonic Joining)

  • 박상준;이영림
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1511-1517
    • /
    • 2012
  • 진공유리 배기공정을 위해 진공챔버나 진공튜브를 이용하는데 챔버 혹은 튜브 내부 전체를 진공으로 만들기 위한 시간과 경비가 과도하게 요구된다. 이러한 문제점을 해결하기 위해 상압에서 진공배기 및 초음파 접합이 동시에 가능한 복합기를 개발하고자 하였는데, 이 경우 진동자인 피에조 온도가 과도하게 상승하여 복합기의 냉각을 최적화할 필요성이 대두되었다. 따라서, 본 연구에서는 수치해석 및 실험을 통해 자연대류 및 강제대류 냉각방식의 효과를 규명하였고 이를 통해 진공 배기 및 초음파 접합 복합기의 냉각 성능을 최적화하였다.

석면 해체.제거 작업에서 사용되는 장비의 성능 기준에 관한 고찰 (A Review on the Performance Criteria of Equipment Required for Asbestos Removal)

  • 이나루
    • 한국산업보건학회지
    • /
    • 제23권3호
    • /
    • pp.212-221
    • /
    • 2013
  • Objectives: Asbestos fibers are accumulated in negative pressure unit (NPU) or vacuum cleaner in asbestos removal. Failure of operation or poor use performance of the NPU or vacuum cleaner causes asbestos fibers to spread in the air. Asbestos contractors should have an NPU fitted with a HEPA , vacuum cleaner, decontamination area, respirators, wetting equipment, and differential pressure manometer to register with the Ministry of Employment and Labor. There should be performance criteria of equipment used in asbestos removal. But there are none such criteria used in asbestos removal. This study was performed to investigate international or national performance criteria of equipment used in asbestos removal. Methods: Regulations, approved code of practice, guidance and national standards of the UK, USA and Korea were reviewed. A survey was done to investigate the requirements for equipment used in asbestos removal in Korea. Results: Air flow of NPUs used in Korea usually covers from$500m^3/h$ to over $3000m^3/h$. Some requirements for NPUs used in Korea were missing compared to the requirements of British standards for NPUs. All NPUs have different missing requirements. The UK also has separate British standard for leak tests for NPUs. Highly hazardous class vacuum cleaners should be used in asbestos removal in the UK. It has national standards on the operation of vacuum cleaners used in asbestos removal. There is only a certification system for less than 2.5kw rated voltage vacuum cleaners for home use in Korea. Powered (-assisted) respirators with mask are recommended in asbestos removal. Type 5 coveralls should be used in asbestos removal in the UK. There are international standards for requirements and leak tests of type 5 coveralls. A manometer for measuring differential pressure is needed in asbestos removal. The manometer's measuring range should cover less than ${\pm}125$ Pa and the gradation of manometer should be less than 2.5 Pa. The definition of decontamination area should be corrected. Installation of airlock and minimum area should be considered in decontamination area. Conclusions: Equipment should be used in asbestos removal proper performance and no leaks. There should be a certification system for equipment used in asbestos removal. This study can help to a certification system for equipment used in asbestos removal in Korea.

후경화기와 경화시간에 따른 3D 프린팅 레진의 굴곡강도 평가 (Evaluation of Flexural Strength of 3D Printing Resin According to Post-Curing Equipment and Time)

  • 김해봄;최재원
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.629-637
    • /
    • 2023
  • This study aimed to evaluate the effect of post-curing equipment and time on the flexural strength of 3D printing resins produced by a liquid crystal display(LCD) printer. The three 3D printing resins(DENTCA Denture Teeth, DT; C&B 5.0 hybrid, CH; C&B Permanent A2, CP) were divided into four groups according to post-curing time(10 min and 30 min) and equipment with or without vacuum treatment. For the three-point flexural strength test and biaxial strength test were prepared by method according to ISO 10477, ISO 6872, respectively. Flexural strength was measured with universal testing machine. Comparison between post-curing time of each post-curing equipment was analyzed by independent sample t-test and Mann-Whitney U test(α=.05), and comparison between groups according to each 3D printing resin was performed by Kruskal-Wallis test and post-hoc by Bonferroni-Dunn test(α=.05). The flexural strength of the resin post-curing under vacuum was higher than that of the resin post-curing in air. In the comparison according to the post-curing time, in the case of the post-curing equipment without vacuum, the 30 minute curing time showed significantly higher flexural strength than the 10 minute curing time, except for the biaxial flexural strength of CH(P<.05). In the post-curing equipment with vacuum, the three-point flexural strength of all 3D printing resins(DT, CH, and CP) showed a higher value at 30 minute curing time than at 10 minute curing time.

실험 계획법을 이용한 진공 차단기의 동특성 최적화 (Dynamic Responses Optimization of Vacuum Circuit Breaker Using Taghchi Method)

  • 조준연;안길영;김성태;양홍익;김규정
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권2호
    • /
    • pp.141-148
    • /
    • 2015
  • 본 연구에서는 진공 차단기(Vacuum circuit breaker)의 동적 특성을 모사하기 위해 리커다인을 이용한 다물체 동역학 해석 모델이 개발 되었다. 진공 차단기는 VI(Vacuum interrupter)를 포함한 3 개의 주회로 부와, 구동 메커니즘을 포함한 기구부로 구성된다. 이 해석적 모델의 검증을 위해, 해석 결과와 실측을 통한 실험적 결과를 비교 하였다. 일반적으로, 원활한 사고 전류 차단을 위해서는 0.9~1.1m/s 의 차단속도(Opening velocity)가 필요하다. 차단 속도의 향상을 위해, 다구찌 기법을 이용하여 진공 차단기의 설계 변수 최적화를 수행하였다. 또한 향상된 차단기의 동적 특성을 검증하기 위해, 해석 결과와 개선된 샘플의 실험적 결과를 비교 분석 하였다.

각종 이젝터를 이용한 진공냉각장치 (Vacuum Cooling System by the Various Ejectors)

  • 윤석훈;김원녕;전현필
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.1-6
    • /
    • 1995
  • Recently, outstanding progresses have been made in food industry, in all the processes involved in the conversion of raw materials into food products. This article describes two kinds of coolers for processing uncooded foor, namely vacuum coolers capable of rapidly cooling decomposing bacteria down to their critical temperature, and also cooling equipment for fresh vegetables based on the same principle as the vacuum cooler.

  • PDF