• Title/Summary/Keyword: vacuum equipment

Search Result 229, Processing Time 0.022 seconds

A Study on the Performance Analysis of Degasser System with Vacuum Pump for Onshore and Offshore Drilling (육상 및 해양 시추용 디개서 시스템의 진공펌프 성능해석)

  • Kwon, Seong-Yong;Park, Sung-Gyu;Shin, Chul-Soon;Kim, Seung-Chan;Lim, Hee-Yeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_2
    • /
    • pp.1063-1069
    • /
    • 2022
  • In modern industry, vacuum has grown into an indispensable industrial field. The performance of the vacuum pump in the degasser system among mud treatment system facilities was verified by a numerical analysis method. The degasser system is an equipment for removing the gas contained in the mud, and it is a work process that requires a vacuum. This study analyzed the vacuum pump performance of the degasser used in drilling for resource development of onshore and offshore plants. The vacuum pump used in the degasser system was designed with a discharge rate of 0.099kg/s. The DM(Design Modeler) program of ansys workbench 17.2 was used to modify the model of the vacuum pump used in the degasser system. And for performance analysis, CFX, which is known to be suitable for rotating system analysis, was used. Finally the performance analysis results of the vacuum pump and the prototype performance test results were compared and analyzed.

A Study on the Development of Expert System for Pneumatic Vacuum Equipment Design (공압 진공장치 설계를 위한 전문가 시스템 개발에 관한 연구)

  • 신흥열;김준식;이재원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.4
    • /
    • pp.15-21
    • /
    • 1997
  • Pneumatics is widly used in the industrial implementation, in the operation of air-powered actuators and the control devices needed in their operation. However, there are many empirical factors in pneumatics design, it might cause excessive design of pneumatic components. For that reason, we developed VDES(Vacuum Design Expert System) for the economic design of pneumatic vacuum equipment. VDES is achieved with CLIPS(C Language Integrated Production System) and knowledge base that contains a number of facts and rules for pneumatic vacuum design. Forward chaining and depth first search technique are used in this system. Appling VDES to the actual field, this system is verified to be a good efficiency and could be applied to the field of pneumatic vacuum equipment design.

  • PDF

A Study on Cooling of Piezoelectric Element of Multifunction Equipment for Vacuum Exhaust and Ultrasonic Joining (진공 배기 및 초음파 접합 복합기 진동자 냉각에 관한 연구)

  • Park, Sang-Jun;Lee, Young-Lim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1511-1517
    • /
    • 2012
  • Vacuum chamber or vacuum tube for the exhaust process of vacuum glazing is presently used, where excessive time and expenses are required to make the whole vacuum chamber or tube vacuum. To solve this problem, multifunction equipment for vacuum exhaust and ultrasonic joining at atmospheric pressure has been developed, in which a piezoelectric vibrator experiences excessive temperature rise resulting in optimizing the cooling of the equipment. Therefore, in this study, cooling effects of natural convection and forced convection methods were identified by numerical analysis and experiments, and cooling performance of the multifunction equipment was optimized.

A Review on the Performance Criteria of Equipment Required for Asbestos Removal (석면 해체.제거 작업에서 사용되는 장비의 성능 기준에 관한 고찰)

  • Lee, Naroo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.212-221
    • /
    • 2013
  • Objectives: Asbestos fibers are accumulated in negative pressure unit (NPU) or vacuum cleaner in asbestos removal. Failure of operation or poor use performance of the NPU or vacuum cleaner causes asbestos fibers to spread in the air. Asbestos contractors should have an NPU fitted with a HEPA , vacuum cleaner, decontamination area, respirators, wetting equipment, and differential pressure manometer to register with the Ministry of Employment and Labor. There should be performance criteria of equipment used in asbestos removal. But there are none such criteria used in asbestos removal. This study was performed to investigate international or national performance criteria of equipment used in asbestos removal. Methods: Regulations, approved code of practice, guidance and national standards of the UK, USA and Korea were reviewed. A survey was done to investigate the requirements for equipment used in asbestos removal in Korea. Results: Air flow of NPUs used in Korea usually covers from$500m^3/h$ to over $3000m^3/h$. Some requirements for NPUs used in Korea were missing compared to the requirements of British standards for NPUs. All NPUs have different missing requirements. The UK also has separate British standard for leak tests for NPUs. Highly hazardous class vacuum cleaners should be used in asbestos removal in the UK. It has national standards on the operation of vacuum cleaners used in asbestos removal. There is only a certification system for less than 2.5kw rated voltage vacuum cleaners for home use in Korea. Powered (-assisted) respirators with mask are recommended in asbestos removal. Type 5 coveralls should be used in asbestos removal in the UK. There are international standards for requirements and leak tests of type 5 coveralls. A manometer for measuring differential pressure is needed in asbestos removal. The manometer's measuring range should cover less than ${\pm}125$ Pa and the gradation of manometer should be less than 2.5 Pa. The definition of decontamination area should be corrected. Installation of airlock and minimum area should be considered in decontamination area. Conclusions: Equipment should be used in asbestos removal proper performance and no leaks. There should be a certification system for equipment used in asbestos removal. This study can help to a certification system for equipment used in asbestos removal in Korea.

Evaluation of Flexural Strength of 3D Printing Resin According to Post-Curing Equipment and Time (후경화기와 경화시간에 따른 3D 프린팅 레진의 굴곡강도 평가)

  • Hae-Bom Kim;Jae-Won Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.629-637
    • /
    • 2023
  • This study aimed to evaluate the effect of post-curing equipment and time on the flexural strength of 3D printing resins produced by a liquid crystal display(LCD) printer. The three 3D printing resins(DENTCA Denture Teeth, DT; C&B 5.0 hybrid, CH; C&B Permanent A2, CP) were divided into four groups according to post-curing time(10 min and 30 min) and equipment with or without vacuum treatment. For the three-point flexural strength test and biaxial strength test were prepared by method according to ISO 10477, ISO 6872, respectively. Flexural strength was measured with universal testing machine. Comparison between post-curing time of each post-curing equipment was analyzed by independent sample t-test and Mann-Whitney U test(α=.05), and comparison between groups according to each 3D printing resin was performed by Kruskal-Wallis test and post-hoc by Bonferroni-Dunn test(α=.05). The flexural strength of the resin post-curing under vacuum was higher than that of the resin post-curing in air. In the comparison according to the post-curing time, in the case of the post-curing equipment without vacuum, the 30 minute curing time showed significantly higher flexural strength than the 10 minute curing time, except for the biaxial flexural strength of CH(P<.05). In the post-curing equipment with vacuum, the three-point flexural strength of all 3D printing resins(DT, CH, and CP) showed a higher value at 30 minute curing time than at 10 minute curing time.

Dynamic Responses Optimization of Vacuum Circuit Breaker Using Taghchi Method (실험 계획법을 이용한 진공 차단기의 동특성 최적화)

  • Jo, Jun Yeon;Ahn, Kil Young;Kim, Sung Tae;Yang, Hong Ik;Kim, Kyu Jung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.2
    • /
    • pp.141-148
    • /
    • 2015
  • In this study, the VCB(Vacuum Circuit Breaker) has been developed using the Recurdyn that is widely used on multibody dynamics analysis. The VCB consists of three main circuits with the VI(Vacuum Interrupter) and the main frame with the operating mechanism. This analytic model is validated by comparing the simulation results and the experimental results. Generally, in order to reliably cut off the breaking current, the opening speed of the VCB after contact separation has to be a 0.9~1.1m/s. Therefore, the study of the design parameters of the VCB is needed. To improve the opening velocity, Taguchi design method is applied to optimize the design parameters of a VCB with a lot of linkages. In addition, to evaluate the improvement of the operating characteristics, the simulation results are compared with the Recurdyn and experimental results with improved prototype sample.

Vacuum Cooling System by the Various Ejectors (각종 이젝터를 이용한 진공냉각장치)

  • 윤석훈;김원녕;전현필
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.4
    • /
    • pp.1-6
    • /
    • 1995
  • Recently, outstanding progresses have been made in food industry, in all the processes involved in the conversion of raw materials into food products. This article describes two kinds of coolers for processing uncooded foor, namely vacuum coolers capable of rapidly cooling decomposing bacteria down to their critical temperature, and also cooling equipment for fresh vegetables based on the same principle as the vacuum cooler.

  • PDF