• Title/Summary/Keyword: vacuum cleaner

Search Result 156, Processing Time 0.031 seconds

Occurrence of Phthalates in Indoor Dust from Children's Facilities and Apartments in Seoul

  • Kim, Ho-Hyun;Lim, Young-Wook;Yang, Ji-Yeon;Shin, Dong-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.382-391
    • /
    • 2009
  • The aim of the study was to assess the levels in typical central borough of phthalate exposure by monitoring children's facilities (19 kindergartens and 21 elementary schools) and households (17 old apartments and 22 new apartments) via sampling indoor floor dust. A vacuum cleaner specifically prepared for sampling dust was attached to a filter of a vacuum cleaner dust collecting container. During the sample preparation process, containers made of glass were used and analysis was performed using GC-MSD. The mean concentration of DEHP was $412{\mu}g/g$, DnBP was $24{\mu}g/g$, and BBzP was $10{\mu}g/g$ dust. The indoor characteristics including floor, wall materials, years after construction, water leakage history for the past three years, and ventilation were also examined to categorize phthalate esters from the dust samples. From the flooring and wallpaper materials of kindergartens and elementary schools, DEHP in the dust sample appeared at a statistically significant level (p<0.05) when PVC materials were present. DEHP in the indoor dust also increased significantly (p<0.01) during the construction period. The daily intake of DEHP measured from indoor dust was 0.08~$19.7{\mu}g/kg/day$ for children and 0.02~$1.1{\mu}g/kg/day$ for adults (women). The results clearly revealed that phthalate exposure is greater in children than in adults (women) due to the indoor dust.

The Amount of House Mite Allergens & Dusts According to Environmental Factors of Patients With Allergic Rhinitis (알레르기성비염 환자 침실의 환경적 특성에 따른 집먼지 진드기 항원량과 먼지량)

  • Moon Jung Soon;Choi Soon Ock
    • Journal of Korean Public Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.51-60
    • /
    • 1996
  • This study was conducted to provide basic knowledges of effective environmental control of patients with allergic rhinitis. From July to October 1995, 58 dust samples Were drawn from the bedrooms of patients with allergic rhinitis who were registerd at an allergy clinic of a hospital. Those samples were examined for the amount of house mite allergens & dusts. The data were analysed by using ANOVA and Pearson correiation coefficients. The results were as follows : 1. As for the amount of house mite allergens in terms of environmental factors, the amount of house mite allergens of using washing water temperature of bedding above than $55^{\circ}C$ was significantly lower than that of below $54^{\circ}C$. Other environmental factors such as type of house, area of bed room floor, bed in bedroom, bedroom cleaning by vacuum cleaner, days after bedding washing, relative humidity of bedroom were relate to the amount of house mite allergens. 2. As for the amount of dusts in terms of environmental factors, the amount of dusts of days of days after bedding washing more than 15 days was significantly lower than thant of less than 15days. Other environmental factors such as type of house, area of bedroom floor, bed in bedroom, bedroom cleaning by vacuum cleaner, was hing water taemperature of bedding, relative humidity of bedroom were not relate to the amount of dusts. 3. There was a significant positive correlation between the amount of house mite allergens and the amount of dusts. It may be conclusively said. the amount of dusts and house mite allergens were closely associated with the washing temperature and days after washing of bedding. Hence. intensive instruction for the methods of bedding washing was needs of the patients with allergic rhinitis.

  • PDF

A Numerical Analysis of the Abatement of VOC with Different Photocatalytic Honeycomb Filters (광촉매 필터형상에 따른 휘발성 유기화합물의 제거에 관한 수치해석적 연구)

  • 류무성;김창녕
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • This study has been numerically conducted to investigate the removal efficiency of Volatile Organic Compound (VOC) for different photocatalytic honeycomb filters. Recently, the photocatalysis is being applied to air-cleaner, air-conditioner and vacuum-cleaner with the capability of air-purification, sterilization and antibiosis. However, photocatalysis is less efficient than other methods for removing VOC except in the case of low concentration. So far most of studies have focused on an improvement of the photocatalytic materials, but this study have placed emphasis on the improvements of shape of photocatalytic honeycomb filter. UV irradiation, concentration profile and pressure drop have been investigated for different cross sections of filters and for different filter lengths. Light intensity is dropped sharply with increasing distance from the UV-lamp, and becomes very low in the middle of the filters. Since photocatalytic reaction rate is a function of light intensity, VOC concentration gradient might be small in the middle of long filters. Thus, most of reaction have risen within only three times of dimensionless axial distance. These results can be used effectively for the design of advanced photocatalytic honeycomb filters.

The Effect of Contamination of Ion Source on Ionic Current of Quadrupole Mass Spectrometer (사중극 질량 분석기의 이온소스 오염이 이온전류에 미치는 영향)

  • Lee, K.C.;Park, C.J.;Kim, J.T.;Oh, E.S.;Hong, K.S.;Hong, S.S.;Lim, I.T.;Yun, J.Y.;Kang, S.W.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.197-202
    • /
    • 2009
  • The long term stability of ion current of QMS has been one of key parameters for monitoring gas process in vacuum. The time dependence of ionic current was monitored while the pressure of nitrogen gas was kept at a fixed pressure by introducing the gas into vacuum chamber. The chamber was evacuated to ${\sim}3{\times}10^{-9}\;Torr$ to reduce background signals before the measurement. Two ion sources were tested; one had brownish or black color due to gas contamination and the other one was new, i.e. cleaner. At a nitrogen pressure of $1{\times}10^{-5}\;Torr$, the ionic currents measured by the contaminated ion source decreased faster with time. The decrease rate was respectively ${\sim}46%$ for cleaner one and ${\sim}84%$ for contaminated one after ${\sim}5.5%$ hours. In order to test the effect of filament material on the ion current decrease, we fabricated a tungsten(W) filament which consisted of two parts; one half was made of W and the other was coated with yttria. The similar decrease of ionic currents were shown for the two types of filaments, indicating that slight change of temperature of filament due to material difference i.e. baking effect could not improve the origin of ionic current decrease. Overall the decreasing rate of ionic current is more closely associated with contaminated ion source of QMS rather than its filament materials.

A Comparative Analysis of Dust Particles Collected by Cleaning Equipments in Subway Tunnel (도시철도 터널 내 청소장치별 집진먼지 비교 분석)

  • Lee, Young-Kwon;Kim, Il-Hong;Jo, Byung-Ki;Kim, Man-Hwa;Park, Jong-Heon
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1388-1398
    • /
    • 2011
  • Air pollution in subway tunnel is primarily caused from the wear of metallic materials. As undesirable substance, PM(Particulate Matter) can especially harm the health of passengers and workers as well as clog the main parts of rolling stock such as inverters. To improve the air quality in subway tunnel, SMRT(Seoul Metropolitan Rapid Transit Corporation) has developed anti-pollution devices such as Magnetic Dust Collector, Vacuum Cleaner For Rail Road and Particulate Removing Sprinkler Vehicle. Introducing these mechanical devices, this paper is mainly devoted to explaining the characteristics of collected dust according to the result of particle-size analysis and componential analysis.

  • PDF

A Study on the Correlation between Frequency Components and Sound Quality of a Vacuum Cleaner using the Orthogonal Array (직교배열표를 이용한 진공 청소기의 음질과 주파수 특성의 상관 관계에 관한 연구)

  • Lim Do-Hyeong;Jeong Hyuk;Ih Jeong-Guon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.295-298
    • /
    • 2000
  • 제품의 음질 특성과 관련된 주요 주파수 대역을 파악하기 위해 본 연구에서는 청소기 소리의 주파수 대역을 음성인식에 중요한 주파수 대역인 4개의 대역으로 나누고, 각 대역 성분을 직교배열표에 따라 가감한 16개의 소리를 만들었다 만들어진 소리에 대해 10명을 대상으로 4가지의 표현어로 Semantic Differential Method(SDM)로 주관적 평가를 하여, 청소기음의 주파수 특성과의 상관관계를 살펴보았다. 불쾌한 느낌과 관련이 깊은 주파수 대역은 고주파수 대역이었으며, 성능이 좋은 느낌을 주기 위해서는 저주파수 대역을 증가시키는 것 이 효과적이었다.

  • PDF

Development of SRM Drive System for Built-in Car Vacuum Cleaner (차량용 Built-in 청소기용 SRM 드라이브 시스템 개발)

  • Lee, Young-Soo;Noh, Jeongmin;Kim, Jaehyuck
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.533-534
    • /
    • 2016
  • 본 논문은 차량용 Built-in 청소기용 SRM(Switched Reluctance Motor) 드라이브 시스템 개발에 대하여 설명한다. 기존의 청소기용 모터는 대부분 영구자석을 사용하는 PMSM 또는 BLDCM이다. 그러나 영구자석의 주 원료인 희토류 광물가격의 상승으로 인해 영구자석형 모터를 대체할 비 희토류 모터(SRM)에 대한 관심이 커지고 있다. 본 논문에서는 제작된 차량용 Built-in 청소기용 SRM의 유한요소해석 데이터를 바탕으로 한 Matlab/Simulink 시뮬레이션 및 실제 실험을 통하여 가능성을 검증하였다.

  • PDF

Analysis of Series Arc-Fault Signals Using Wavelet Transform (웨이블렛 변환을 이용한 직렬 아크고장 신호 분석)

  • Bang, Sun-Bae;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.494-500
    • /
    • 2008
  • This paper presents the analyzed result of the series arc fault current by using the discrete wavelet transform. The series arcing is caused by a loose connection in series with the load circuit. The series arc current is limited to a moderate value by the resistance of the device connected to the circuit, such as an appliance or a lighting system. The amount of energy in the sparks from the series arcing is less than in the case of parallel arcing but only a few amps are enough to be a fire hazard. Therefore, it is hard to detect the distinctive difference between a normal current and a intermittent arc current. This paper, presents the variation of the ratio of peak values and RMS values of the series arc fault current, and proposes the novel series arc fault detecting method by using the discrete wavelet transform. Loads such as a CFL lamp, a vacuum cleaner, a personal computer, and a television, which has the very similar normal current with the arc current, were selected to confirm the novel method.

A Study on Perceptual Evaluation of Noise Sources in Living Environment (생활소음의 감성적 평가에 관한 연구)

  • 전진용;구민우;조문재
    • Journal of KSNVE
    • /
    • v.11 no.3
    • /
    • pp.443-448
    • /
    • 2001
  • The subjective unwantedness felt from the noise sources in living environment has been evaluated by investigating the limit of perceptual loudness of the noise. The noise limits were selected by the subjects. And the noises were analyzed to find out whether there is any correlation with Zwicker parameters and ACF/IACF factors. It seemed that the loudness of noise from vacuum cleaner does not affect its perceives noisiness. Traffic noise also seems to be less influential in annoyance rating. It was resealed that floor impact noise generated by bang machine is the most irritating noise that can be heard in residential buildings.

  • PDF

Full-Coverage algorithm with local obstacle avoidance algorithm (지역적 회피 알고리즘을 갖는 Full-Coverage 알고리즘)

  • Park G-M.;Son Y-D.;Kim Y.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1468-1471
    • /
    • 2005
  • This Paper is to find out a solution for the full-coverage algorithm requiring the real-time processing such as mobile home service robots and vacuum cleaner robots. Previous methods are used by adopting based grid approach method. They used lots of sensors, a high speed CPU, expensive ranger sensors and huge memory. Besides, most full-coverage algorithms should have a map before obstacle avoidance. However, if a robot able to recognize the tangent vector of obstacles, it is able to bring the same result with less sensors and simplified hardware. Therefore, this study suggests a topological based approach and a local obstacle voidance method using a few of PSD sensors and ultra sonic sensors. The simulation results are presented to prove its applicability.

  • PDF