• 제목/요약/키워드: vacuum arc

검색결과 323건 처리시간 0.027초

3petal spiral type vacuum interrupter에서 가동접점전극과 고정접점전극간의 마주보는 각도의 변화가 아크구동력에 미치는 영향 (Influence of twisting angle between fixed contact and movable contact on arc driving force in 3petal spiral type vacuum interrupter)

  • 김병철;윤재훈;이승수;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.480-480
    • /
    • 2008
  • Vacuum circuit breaker(VCB) is now emerging as an alternative of gas circuit breaker(GCB) which uses SF6 gas as insulating material whose dielectric strength is outstanding. But we have to reduce SF6 gas because SF6 gas is one of greenhouse gas and efforts to reduce greenhouse gas are now trend of the world. Therefore, we can say VCB is the optimal alternative of GCB because vacuum is environmentally friendly. The vacuum interrupter is the core part of VCB to interrupt arcing current. There are mainly two methods to extinguish arc. One is radial magnetic field (RMF) method and the other is axial magnetic field (AMF) method. We deals with RMF method in this paper. Compared with AMP, RMF arc quenching method has different principle to extinguish arc. In case of RMF method, pinch effect is much larger than AMF method. Because of pinch effect RMF type contact electrodes have the single large spot which is severly damaged and melted while AMF type contact electrodes have small and multiple spots which are slightly damaged and melted. To prevent contact electrode being damaged and melted from high temperature-arc, RMF method uses Lorentz force to move arc. In this paper we calculated and compared the arc driving force of two cases and we analyzed the force acting on each part of arc by means of commercial finite element method software Maxwell 3D. They have 3petals and we considered two cases. One is the case when fixed(upper) and movable(lower) contacts are in mirror arrangement (Case 1). The other is the case when one of two contacts (movable contact) is revolved at maximum angle as possible as it can be (Case 2). And at each case above, we analyzed arc driving force at two positions, position 1 is the closest to the center of contact and position 2 is near the edge of petal on fixed contact. As a result we could find that Case 2 generated stronger arc driving force than Case 1 at position 1. But at position 2 Case 1 generated stronger arc driving force than Case 2. This simulation method can contribute to optimizing spiral-type electrode designs in a view of arc driving force.

  • PDF

진공차단부에서 발생하는 확산형 아크 수치해석 (Numerical Study on a Diffused-mode Arc within a Vacuum Interrupter)

  • 조성훈;황정훈;이종철;최명준;권중록;김윤제
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.479-482
    • /
    • 2008
  • In order to more closely examine the vacuum arc phenomena, it is necessary to predict the magnetohydrodynamic (MHD) characteristics by the multidisciplinary numerical modeling, which is coupled with the electromagnetic and hydrodynamic fields, simultaneously. In this study, the thermal-fluid characteristics of high current vacuum arcs were calculated by a commercial multiphysics package, ANSYS, in order to obtain Joule heat, Lorentz force and the interactions with flow variables. We assumed the diffused-mode arc within an AMF vacuum interrupter. It was found with four different currents that the temperature distributions on the anode surface are diffused uniformly without concentration in 7kA for both types (cup and coil-type). But the arc plasma transition and an increase of thermal flux density for increasing the applied current have caused the change of temperature distributions on the anode surface. We should need further studies on the two-way coupling method and radiation model for arc plasmas in order to accomplish the advanced analysis method for multiphysics.

  • PDF

진공아크 증착법과 다른 공정에 의해 증착된 MgO 박막 특성 비교 (Comparison of characteristics of MgO films deposited by vacuum arc method with other methods.)

  • 이은성;김종국;이성훈;이건환
    • 한국진공학회지
    • /
    • 제12권2호
    • /
    • pp.112-117
    • /
    • 2003
  • MgO 박막은 PDP(plasma display panels)분야에서 널리 사용되어 왔다. 본 연구에서는, 기존에 사용되고 있는 e-beam evaporation, reactive magnetron sputtering법과 arc deposition법으로 MgO 보호막을 증착하여 구조적 · 광학적 특성을 비교하였다. 반응 가스인 산소 가스의 유입량을 변화시켜 Mg metal target을 이용하여 vacuum arc deposition equipment 의해 유리 기판 위에 증착하였다. Ellipsometer를 이용하여 치밀도를 측정하고, MgO보호막의 마모율(erosion rate)를 측정하기 위해 가속 실험 방법을 도입, Ar+ 이온빔에 의한 erosion test를 시행하여 내마모성을 알아보았다. 또한, XPS와 UV test를 사용하여 MgO보호막의 광투과도에 미치는 수분의 영향을 조사한 결과, arc evaporation 법이 광투과도 90%이상을 유지하여 수분의 영향에 둔감한 것을 알 수 있었다. 한편, XRD와 AFM을 이용하여 MgO 박막의 구조와 표면 형상에 대해 조사하였다.

비정질 다이아몬드 코팅을 위한 자장여과 아크소스의 동작 특성에 관한 연구 (Operation Characteristic of Filtered Vacuum Arc Source for Amorphous Diamond Coating)

  • 김종국;이구현
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.147-157
    • /
    • 2000
  • The filtered vacuum arc source (FVAS), which is adopted by magnetic filtering methode to remove the macro-particle in vacuum arc plasma, was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were consisted of one permanent magnet, one magnetic yoke and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Graphite was used as the cathode material to coat the amorphic diamond film and its diameter was 80 mm. The amorphic diamond film attracts much attention due to its excellent mechanical, optical and tribological properties suitable for wide range of applications. The effects of solenoid magnet in plasma extraction were studied by computer simulation and experiment using Taguchi's method. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. Optimum deposition condition was obtained when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, and 5 A, respectively.

  • PDF

아크계측 및 응용연구를 위한 LC공진회로 전류원 구축 (Installation of Current Source Using LC Resonance Circuit for Arcing Experiments)

  • 강종성;박홍태;최원준;이방욱;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2113-2115
    • /
    • 2000
  • It is necessary to install the arc generation facility in order to obtain the important technology for the design of breakers and switches, and for the improvement of their performance and reliability. With this facility, it is possible, to study the characteristics of Arc in air/gas/vacuum insulation environment. The facility briefly consists of capacitor bank which can charge enormous energy, an air-core reactor, experimental arc-chamber, and several measurement equipments. This facility can simulates the arc phenomena in breakers and switches by means of generating high currents. In order to study the arc phenomena in SF6 gas and vacuum and to test the quenching performance of the extinguishing chambers which are developing. we made experimental $SF_6$gas/vacuum chambers and measured several parameter's of chambers. And besides we visualized arc ignition and arc movement by means of high speed camera.

  • PDF

진공 인터럽터의 3차원 유한요소해석 (Three-Dimensional Finite Element Analysis of a Vacuum Interrupter)

  • 최승길;강형부
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권10호
    • /
    • pp.693-698
    • /
    • 1999
  • Vacuum interrupters have a special asymmetric electrode structure to generate an magnetic field and consequently to increase the interrupting ability. Accordingly 2-dimensional analysis has a large analysis error because radial flux can not be considered. In this paper, in order to analyse the electric field distribution of a vacuum interrupter with arc shield more accurately, 3-dimensional finite element method(FEM) is used. The induced electric potentials of floating shield was increased with the gap distance, which is because the relative position of shield is closer to the fixed contact so that the capacitance distribution inside interrupter is varied. The calculated results also show that the induced potential of shield causes electric field distortion so that the maximum value of electric field in a vacuum interrupter with arc shield is higher than that without one.

  • PDF

Prediction of Anode Temperatures of Free Burning Arcs Using a Simplified Unified Model

  • 전홍필;이종철
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.565-565
    • /
    • 2013
  • Free burning arcs where the work piece acts as an anode are frequently used for a number of applications. Our investigation is exclusively concerned with a simplified unified model of arcs and anode under steady state conditions at atmospheric pressure. The model is used to make predictions of arc and anode temperatures and arc voltage for a 200 A arc in argon. The computed temperatures along the axis between the cathode tip and the anode surface compare well the measured data. This knowledge of free burning arcfeatures can play a role in developing the atmospheric plasma systems, however, further investigation should include the modelling of Cu evaporation from anode and non-LTE situation near electrodes for more realistic calculations.

  • PDF

The Magnetic Filtering Vacuum Arc Film Deposition System and Its Applications

  • Wang, G.F.;Zhang, H.X.;Zhang, H.J.;Zhu, H.
    • 한국진공학회지
    • /
    • 제6권S1호
    • /
    • pp.137-140
    • /
    • 1997
  • A cathodic arc with beam filter is employed for the deposition of metallic and hydrogen-free amorphous carbon films. A solenoid filter is used to prevent macropaticles and nonionized atoms from reaching the substrate. The detail transport characters of the filter are presented in the paper. With an optmum filter arrangement we are able to obtain a filter output of 18.4% of the total number of ions produced by the vacuum arc discharge. The deposited amorphous cabon thin film contains no hydrogen and a high fraction of $sp^3$ is determined by XPS. A dense Ti film deposited on H13 steel improves the corrosion resistance of the H13 steel and significant improvements of corrosion resistance were observed by implanting Ti, C in the film.

  • PDF

고청정 Alloy718 잉고트 Cogging (Cogging of premium-quality Alloy 718)

  • 박노광;염종택;임정숙;최상욱
    • 한국군사과학기술학회지
    • /
    • 제6권4호
    • /
    • pp.159-166
    • /
    • 2003
  • Microstructures and mechanical properties of VIM/VAR/VAR-processed Ni-based Alloy718 ingot were investigated. Vacuum arc remelting(VAR) results in chill grain zone, columnar grain zone, and equi-axed grain zone in the ingot due to the difference in local solidification processes. Different grain structures of the remelting ingot result in the different hot workability for the given cogging conditions. Experimental results on microstructural inhomogeniety and material flow behavior under billet cogging conditions were presented, and their potential effects on the billet cogging process are discussed.

설계변수에 따른 진공인터럽터용 종자계방식 전극의 아크특성에 관한 연구 (A Study on the Arc Characteristics of Axial Magnetic Field Type Electrode for Vacuum interrupter by Desing Parameters)

  • 김성일;박흥태;안희일;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.672-674
    • /
    • 2001
  • Axial magnetic field(AMF) type electrode can increase the interrupting capability of vacuum interrupters. But, this interrupting capability vary with design parameters such as shape of electrode, slits of contact, material of contact and so on. In this paper, shown arc characteristics of unipolar axial magnetic field type electrode for vacuum interrupter by design parameters such as shape of contact slits and diameter of contact. And, confirmed vacuum arc configuration by individual design parameter using high speed camera.

  • PDF