• Title/Summary/Keyword: vacA

Search Result 176, Processing Time 0.019 seconds

Helicobacter pylori vacA Mosaicism and New Primers for vacA Signal Sequence Indigenous to Korea (Helicobacter pylori vacA 대립유전자의 Mosaicism과 Signal Sequence의 한국고유 시발체)

  • Ahn, Yeon-Hwa;Kim, Heung-Ryel;Lee, Ji-Eun;Hwang, Tae-Sook;Choe, Yon-Ho
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • Purpose: Helicobacter pylori has been known to have diverse vacA allelic types. The purpose of the study was to identify vacA diversity in Korea and design new primers for signal sequence alleles indigenous to Korea. Methods: Fifty antral biopsy specimens, which had been proven to be H. pylori-positive, were examined for vacA status; signal sequence and mid-region. After PCR amplification and DNA sequencing, vacA alleles of Korean H. pylori strains were compared with those from other countries. Results: Among Korean H. pylori strains vacA alleles with all combinations of signal sequence and mid-region were found, with the exception of s1b or s2. vacA genotype s1c/m1 was predominant in Korea. We found that GGGAGCGTTR in s1a and GGGGYTATTG in s1c were the indigenous sequences to Korea and constructed the new Korean specific primers for the vacA signal sequence; VASK-F, VASK-R, S1AK-F, and S1CK-F. Conclusion: This study showed that s1c/m1 is the predominant type of vacA allele in Korea. We designed new primers for the vacA signal sequence.

  • PDF

Pathogenetic Impact of Vacuolar Degeneration by Accelerated Transport of Helicobacter pylori VacA

  • Choi, Kyung-Min;Park, Jeong-Kyu;Hwang, Se-Young
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.5
    • /
    • pp.666-672
    • /
    • 2003
  • Vacuolar degeneration of the gastric epithelial cells is a characteristic feature of the derangement of mucosa where Helicobacter pylori colonizes, and H. pylori vacuolating cytotoxin (VacA) has been suggested to playa key role in it. To elucidate the VacA-involved degenerative mechanism, VacA was purified, and its impact on degeneration of HeLa cells was determined. In the presence of ammonium chloride, cell vacuolation by VacA was dose-and time-dependent, however, no detectable degeneration of the cells was observed with the VacA concentration tested. A further increase of vacuolation was shown in cells pre-treated with diethyl pyrocarbonate (DEPC) , and this resulted in a change of the cell morphology to become spherical. Similar phenomena were also observed when HeLa cells were co-cultivated with intact H. pylori cells. It was remarkable to note that the degree of growth inhibition was proportional to the increase in vacuole formation, suggesting that the vacuolation rate would be critical for cell degeneration. Surprisingly, although VacA was itself inhibited by DEPC, its uptake was markedly increased by this agent, similar to that found in cells with Nabutyrate. These data indicate that the cell's tolerance of VacA transport may be critical for vacuolar degeneration and may be changeable during H. pylori inhabitation.

A study on Applicability of VacCAD Simulator

  • Kim, Hyung-Taek;Kim, Kang-Won
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.200-206
    • /
    • 2019
  • In this study, we compared the VacCAD and VacSim(Multi), commercial vacuum simulators, to verify the advantages of VacCAD's efficiency. It was emphasized on immediacy and simplicity of simulation modelling, and characteristics of the pump combinations, pumping down curves, and vacuum materials. First, usability of simulation mechanism was estimated through the modeling schematics and obtained simulation results of each employed simulator were compared to evaluate the applicability in practice. Simulation reliability of each simulator was also probed by comparing the pumping characteristics of commercially available high vacuum systems. In addition, the degree of tolerances on VacCAD was also investigated through pumping down analysis considering outgassing effect due to chamber material variations. The higher effectiveness and expediency of VacCAD than VacSim(Multi) has been presented, and it was expected that the utilization of VacCAD in vacuum applications to be increased.

Helicobacter pylori Vacuolating Toxin Exhibits Polar Activity of $Cl^-$ Secretion and Secretory Response to Carbachol in T84 Cells

  • Jin, Nan-Ge;Jin, Yong-Ri;So, In-Suk;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.8 no.5
    • /
    • pp.289-293
    • /
    • 2004
  • To investigate whether VacA (vacuolating toxin) produced by Helicobacter pylori Korean stain 99 induces intestinal secretion, purified VacA was added to T84 cell monolayers mounted in Ussing chambers, and electrical parameters were monitored. Mucosal addition of low pH-pretreated VacA increased short circuit current (Isc). The effect was time- and dose-dependent and saturable. The time-to-peak Isc was concentration-dependent. Chloride channel inhibitors, niflumic acid or 5-nitro-2-(3-phenylpropylamino)-benzoate (NPPB), inhibited VacA-stimulated Isc. Carbachol (CCh)-induced increase of Isc was prolonged by the addition of VacA to the mucosal side only. The effect was unaltered by the addition of niflumic acid. VacA did not show cytopathic effects. These studies indicate that VacA is a nonlethal toxin that acts in a polar manner on T84 monolayers to potentiate $Cl^-$ secretion and the response to CCh secretion without decrease in monolayer resistance. VacA may contribute to diarrhea diseases in human intestinal epithelial cells.

A Comparison of Simulation Characteristics of VacCAD and VacTran as Vacuum Simulator

  • Hyung-Taek Kim
    • International journal of advanced smart convergence
    • /
    • v.12 no.4
    • /
    • pp.217-223
    • /
    • 2023
  • In this study, we compared the VacCAD and VacTran, commercial vacuum simulators, to investigate the simulation applicability and efficiency as vacuum simulation software. It was verified on reliability and simplicity of simulation modelling, and characteristics of the pump combinations, pumping down curves, and employed vacuum materials. First, usability of simulation schematics was estimated through the modeling tools and the overall simulation characteristics of each simulator were compared to evaluate the applicability in practice. Simulation reliability of each simulator was also probed by comparing the pumping performance characteristics of commercial high vacuum system models. In addition, the degree of tolerances on both simulators was also evaluated through pumping down analysis considering outgassing effect due to chamber material variations. The higher effectiveness and expediency of VacCAD than VacTran has been presented, and it was also expected that the utilization of VacTan in vacuum applications to be increased due to the higher availability of modelling variations.

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.

  • PDF

The Use of Vacuum-Assisted-Closure Theraphy for the Treatment of Methicillin-Resistant-Staphylococcus aureus Infected Wounds (메치실린 저항 포도알균에 감염된 창상 치료에 있어 음압요법의 의의)

  • Kim, Joo Hyoung;Park, Myoung Chul;Lee, Il Jae;Park, Dong Ha
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.632-636
    • /
    • 2006
  • Purpose: Methicillin-Resistant-Staphylococcus aureus(MRSA) has been increasingly recognized as a cause of nosocomial infection. MRSA is hardly-controllable organism among the pathogen of nosocomial infection, because it is resistant to most antibiotics except vancomycin, and local treatment with most antiseptics are not effective to eradicate MRSA from the infection. The effectiveness of Vacuum-Assisted-Closure(VAC) was reported widely. we tried to modify original VAC. We tried VAC dressing on MRSA infected wound to evaluate whether or not the VAC is effective to eradicate MRSA which existed in the open wound. Methods: From September 2003 to December 2003, 24 patients admitted to the plastic and reconstructive surgery and orthopedic surgery, were studied. All patients were found to be positive in previous wound. Using clinical randomized study, 24 patients were divided into two groups: VAC dressing group and the $Betadine^{(R)}$ dressing group(control). During treatment, wound culture was done twice a week for evaluation of MRSA infection elimination. Results: The mean period that MRSA become not detected in all case was 17.1 days in VAC dressing group, and 25.8 days in control group, respectively. The p value was 0.013. The result reveals that the VAC dressing group is more effective to MRSA infection control. As a result, the VAC dressing was more effective in MRSA infected wound than conventional dressing. Conclusion: Through this study, we found objective result of VAC dressing. We hope that VAC dressing is more widely applied to fresh and infected wound.

Construction of CpG Motif-enriched DNA Vaccine Plasmids for Enhanced Early Immune Response

  • Park Young Seoub;Hwang Seung Ha;Choi Cha-Yong
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.10 no.1
    • /
    • pp.29-33
    • /
    • 2005
  • A DNA vaccine methodology using eukaryote expression vectors to produce immunizing proteins in the vaccinated hosts is a novel approach to the development of vaccine and immuno-therapeutics, and it has achieved considerable success over several infectious diseases and various cancers. To further enhance its efficiency, attempts were made to develop novel plasmid vectors containing multiple immunostimulatory CpG motifs, for rapid and strong immune response. First, a 2.9 kb compact plasmid vector (pVAC), containing CMV promoter, polycloning site, BGH poly(A) terminator, ampicillin resistance gene and pBR322 origin was constructed. A pVAC-hEPO was also constructed, which contained a human erythropoietin gene, for evaluating the transfection efficiency of naked plasmid DNA both in vitro and in vivo. To examine the adjuvant effect of multi-CpG motifs on naked plasmid DNA, 22 and 44 enriched and unmethylated CpG motifs were introduced into pVAC to generate pVAC-ISS1 and pVAC-ISS2, respectively. $100{\mu}g$ of pSecTagB, pVAC, pVAC-ISS1 or pVAC-ISS2 were each injected intramuscularly into the tibilias anterior muscle of Balb/c mice. The level of interleukin-6 induced in the mice injected with pVAC-ISS1 and pVAC-ISS2 were significantly elevated after 12 hours, which were almost 2 and 2.5 times higher than that in the mice injected with pSecTagB, respectively. These results suggest that DNA vaccine plasmids with enriched CpG motifs can induce rapid secretion of interleukin-6 by lymphocytes. In conclusion, these vectors can contribute to the development of adjuvant-free DNA vaccinations against infectious diseases and various cancers.

The Efficiency of VAC(Vacuum-Assisted Closure) in Non-healing Wound (하지의 난치성 창상치유에 있어 VAC(Vacuum-Assisted Closure)의 유용성)

  • Park, Jung Min;Kwon, Yong Seok;Jung, Ki Hwan;Lee, Keun Cheol;Kim, Seok Kwun;An, Won Suk
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.727-732
    • /
    • 2005
  • The treatment of wounds of the lower extremity caused by diabetes or vascular dysfunction remains a difficult problem for the plastic surgeon. The use of negative pressure in wound healing is a relatively new method to facilitate chronic wound healing by secondary healing. The use of vacuum-assisted closure(VAC) system is purposed to reduce local edema, increase regional blood flow, enhance epithelial migration, preserve a moist wound environment, reduce bacterial colonization, promote granulation tissue formation, and mechanically enhance wound closure. The VAC also can be used as a dressing for anchoring an applied split thickness skin graft. We reviewed the data from 20 consecutive patients with non-healing wound in lower extremity at Dong-A University from March 2002 to December 2004. We used the VAC in 20 patients and compared the results with the control group. In the VAC using group, mean application duration was about 3 weeks and dressing change was done every other day. The follow-up period of patients ranged from 3 months to 30 months with a mean of 17 months. The points of comparison with control group are wound size, granulation tissue proliferation rate, operation method, preoperative time, postoperative healing time, complication, and cost. With those points, we propose to approve the efficiency of the VAC in non-healing wound. As a result, the VAC used in non-healing wound decrease wound size, accelerate granulation tissue formation, do a wound closure with less invasive operation method, make less postoperative complication, can make operation time shorter. Therefore it is cost effect. Our results demonstrate the usefulness of VAC as an adjunct in management of chronic wounds with other extrinsic factors.

Sci-B-Vac의 급성독성에 관한 연구

  • 이영순;강경선;서광원;남기환;조재진
    • Toxicological Research
    • /
    • v.9 no.2
    • /
    • pp.225-232
    • /
    • 1993
  • SCi-B-Vac, the 3rd hepatitis B vaccine , was selected for clinical evaluation on the basis of toxicologic profiles in preclinical studies. These studies were performed to obtain information on its toxic signs, organs which are mainly affected, and to estimate its lethality in mice and rats given Sci-B-Vac through two routes of administratin. In male and female rats given a single intragastrical dose of Sci-B-Vac, we estimated that $LD_{50}$ values were over 2.00 ml/100g B.W. (10ng/ml), respectively.

  • PDF