• Title/Summary/Keyword: vAm

Search Result 303, Processing Time 0.026 seconds

Electrodeposition of some Alpha-Emitting Nuclides and its Isotope Determination by Alpha Spectrometry (몇가지 알파입자 방출 핵종의 전해석출 및 알파 스펙트럼 측정에 의한 그의 동위원소 정량)

  • Key-Suck Jung;In-Suck Suh
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.279-286
    • /
    • 1983
  • An apparatus was made for the electrodeposition of alpha emitting actinide nuclides, $^{207}Bi$ and $^{210}Po$. The electrodeposition was made on a polished stainless steel plate cathode. The anode was made of platinum wire and to stir the solution. With the ammonium chloride as electrolyte initial pH = 4, chloride concentration = 0.6M and solution volume = 15ml, a current of 1.5 ampere(current density = 0.59A/$cm^2$) was flowed for 100 minutes for the quantitative recovery of electrodeposition and on average recovery of 98.3% was obtained within ${\pm}$0.7% uncertainty. Alpha spectrometry of the electrodeposited sample showed alpha peaks from $^{210}Po, ^{234}U$ and $^{239}Pu$ having energy resolution (FWHM) of 18.3, 21.8 and 36.0 keV respectively. The electrodeposition and alpha spectrometry for a natural uranium sample of domestic origin gave $^{238}U : ^{234}U = 1 : 6.1{\times}10^{-5}$ and for a neutron-irradiated uranium sample did $^{238}U : ^{239}Pu : ^{241}Am = 100 : 0.0263 : 5.20{times}10^{-5}$. The result of $^{238}U$ determination in the irradiated sample by electrodeposition-alpha spectrometry was in accord within ${\pm}1.6%$ of relative error with the results of solid fluorimetry and mass spectrometry. For $^{239}Pu$ the result of electrodeposition-alpha spectrometry was in accord within ${\pm}$4.0% of relative error with the results of anion exchange separation and the thenoyltrifluoroacetone(TTA) extraction both followed by alpha spectrometries.

  • PDF

Quality characteristics of detoxified Rhus verniciflua vinegar fermented using different acetic acid bacteria (초산균 종류에 따른 무독화 옻식초의 품질 특성)

  • Baek, Seong Yeol;Kim, Ji-Seon;Mun, Ji-Young;Lee, Choong Hwan;Park, Yoo Kyoung;Yeo, Soo-Hwan
    • Food Science and Preservation
    • /
    • v.23 no.3
    • /
    • pp.347-354
    • /
    • 2016
  • To investigate the effect of different acetic acid bacteria on qualities of detoxified Rhus verniciflua vinegar (DRV), different DRVs were produced by using three acetic acid bacterial strains including Acetobacter pasteurianus KACC16934 (AP), Acetobacter malorum V5-7 (AM), and Gluconoacetobacter entanii RDAF-S (GE). Little difference in pH (2.87~2.90) or titratable acidity (5.33~5.68%) was observed among different DRVs. Acetic acid yields of the AP, AM, and GE strains were 78.6%, 85.3%, and 85.9%, respectively. Organic acid content in different DRVs was in the range of 69.84~73.83 mg/mL. Oxalic acid, malic acid, succinic acid, acetic acid, and fumaric acid were detected in all DRVs. And glutamic acid, alanine, valine, leucine, tyrosine, lysine, anserine, and arginine were detected in all DRVs. Arginine and alanine were the predominant amino acids in all DRVs. PCA plots of electronic nose analysis data showed a significant differentiation of DRVs from different acetic acid bacterial strains. A sensory evaluation of all DRVs indicated that DRV fermented using AM was superior in the aspect of flavor, tasted and overall preference.

Synthesis and Photovoltaic Properties of Copolymers with Fluorinated Quinoxaline and Fluorene Moiety (Fluorine이 도입된 Quinoxaline과 Fluorene 골격을 가진 고분자의 합성 및 특성분석)

  • Song, Suhee;Choi, Hyo Il;Shin, In Soo;Park, Seong Soo;Lee, Gun Dae;Park, Sung Heum;Jin, Youngeup
    • Applied Chemistry for Engineering
    • /
    • v.27 no.5
    • /
    • pp.467-471
    • /
    • 2016
  • New electron deficient moiety, 6,7-difluoro-2,3-dihexylquinoxaline, was developed for the push-pull type copolymer for organic photovoltaics (OPVs). The PFDTQxF with lower HOMO energy level was synthesized using fluorene and 6,7-difluoro- 2,3-dihexylquinoxaline by Suzuki polymerization. The PFDTQxF thin film shows two absorption peaks at 368 and 493 nm. The HOMO and LUMO energy levels of PFDTQxF are calculated -5.55 and -3.91 eV, respectively. The device comprising PFDTQxF showed a $V_{OC}$ value of 0.47 V, a $J_{SC}$ value of $4.48mA/cm^2$, and a FF of 0.32, which yielded PCE of 0.78%, under the illumination of AM 1.5.

A novel approach in voltage transient technique for the measurement of electron mobility and mobility-lifetime product in CdZnTe detectors

  • Yucel, H.;Birgul, O.;Uyar, E.;Cubukcu, S.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.731-737
    • /
    • 2019
  • In this study, a new measurement method based on voltage transients in CdZnTe detectors response to low energy photon irradiations is applied to measure the electron mobility (${\mu}_e$) and electron mobility-lifetime product $({\mu}{\tau})_e$ in a CdZnTe detector. In the proposed method, the pulse rise times are derived from low energy photon response to 59.5 keV($^{241}Am$), 88 keV($^{109}Cd$) and 122 keV($^{57}Co$) ${\gamma}-rays$ for the irradiation of the cathode surface at each detector for different bias voltages. The electron $({\mu}{\tau})_e$ product was then determined by measuring the variation in the photopeak amplitude as a function of bias voltage at a given photon energy using a pulse-height analyzer. The $({\mu}{\tau})_e$ values were found to be $(9.6{\pm}1.4){\times}10^{-3}cm^2V^{-1}$ for $1000mm^3$, $(8.4{\pm}1.6){\times}10^{-3}cm^2V^{-1}$ for $1687.5mm^3$ and $(7.6{\pm}1.1){\times}10^{-3}cm^2V^{-1}$ for $2250mm^3$ CdZnTe detectors. Those results were then compared with the literature $({\mu}{\tau})_e$ values for CdZnTe detectors. The present results indicate that, the electron mobility ${\mu}_e$ and electron $({\mu}{\tau})_e$ values in CdZnTe detectors can be measured easily by applying voltage transients response to low energy photons, utilizing a fast signal acquisition and data reduction and evaluation.

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Electrochemical Characteristics of Ion-Exchange Membrane and Charged Mosaic Membrane (복합 하전 모자이크 막과 이온교환 막의 전기적화학적 특성)

  • Yang, Wong-Kang;Song, Myung-Kwan;Cho, Young-Suk
    • Membrane Journal
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • The effect of anionic and cationic exchange polymer layer on the chronopotentiometry (CP) and current voltage curves (I-V) of charged composite membrane are investigated. Also, the ion transport near the interface between electrolyte and ionic exchange polymer membranes (anionic and cationic ones) and charged mosaic polymer composite membrane is studied. The results show that both anionic and cationic polymer exchange membranes exhibit lower voltage drop over range of applied current density and possess favorable industrial application potentials, especially at low KCl concentration. While the charged mosaic polymer composite membrane didn't show any current-voltage change, irrespective to the type and the concentration of used electrolyte. CP and I-V measurements are effectively used to give some fundamental understanding for ion transport behavior of ion exchange polymer membrane near the interlace.

Variation of Axial Tension-Compression Fatigue Characteristics by UNSM on Ti-6Al-4V (Ti-6Al-4V재의 UNSM처리에 의한 축인장압축피로특성변화)

  • Suh, Chang-Min;Cho, Sung-Am;Pyoun, Young-Sik;Suh, Min-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.42-48
    • /
    • 2011
  • The present study makes three original contributions to nanoskinned Ti-6Al-4V materials. The nanoskins were fabricated on Ti-6Al-4V material using various surface treatments: deep rolling (DR), laser shot peening (LSP), and ultrasonic nanocrystal surface modification (UNSM). These surface treatments are newly developed techniques and are becoming more popular in industrial fields. A fatigue strength comparison at up to 106 cycles was conducted on these nanoskinned Ti-6Al-4V materials. Fatigue tests were carried out using MTS under axial loading tension-compression fatigue (R = -1, RT, 5 Hz, sinusoidal wave). The analysis of the crack initiation patterns in the nanoskinned Ti-6Al-4V materials found an interior originating crack pattern and surface originating crack type. Microscopic observation was mainly used to investigate the fatigue fractured sites. These surface modification techniques have been widely adopted, primarily because of the robust grade of their mechanical properties. These are mainly the result of the formation of a large-scale, deep, and useful compressive residual stress, the formation of nanocrystals by the severe plastic deformation (SPD) at the subsurface layer, and the increase in surface hardness.

Fabrication and Characteristics of High Efficiency Silicon PERL (passivated emitter and rear locally-diffused cell) Solar Cells (PERL (passivated emitter and rear locally-diffused cell) 방식을 이용한 고효율 Si 태양전지의 제작 및 특성)

  • Kwon, Oh-Joon;Jeoung, Hun;Nam, Ki-Hong;Kim, Yeung-Woo;Bae, Seung-Chun;Park, Sung-Keoun;Kwon, Sung-Yeol;Kim, Woo-Hyun;Kim, Ki-Wan
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.283-290
    • /
    • 1999
  • The $n^+/p/p^+$ junction PERL solar cell of $0.1{\sim}2{\Omega}{\cdot}cm$ (100) p type silicon wafer was fabricated through the following steps; that is, wafer cutting, inverted pyramidally textured surfaces etching by KOH, phosphorus and boron diffusion, anti-reflection coating, grid formation and contact annealing. At this time, the optical characteristics of device surface and the efficiency of doping concentration for resistivity were investigated. And diffusion depth and doping concentration for n+ doping were simulated by silvaco program. Then their results were compared with measured results. Under the illumination of AM (air mass)1.5, $100\;mW/cm^2$ $I_{sc}$, $V_{oc}$, fill factor and the conversion efficiency were 43mA, 0.6 V, 0.62. and 16% respectively.

  • PDF

Electronic Properties of MIM Structure Organic Thin-films that Manufacture by LB method (LB법으로 제작한 MIM 구조 유기 박막의 전자특성)

  • Choi, Young-Il;Lee, Kyung-Sup;Lim, Jung-Yeol;Song, Jin-Won
    • 전자공학회논문지 IE
    • /
    • v.43 no.4
    • /
    • pp.99-104
    • /
    • 2006
  • The Langmuir-Blodgett(LB) technique has attracted considerable interest in the fabrication of electrical and electronic devices. Maxwell displacement current (MDC) measurement has been employed to study the dielectric property of Langmuir-films. MDC flowing across monolayers is analyzed using a rod-like molecular model. A linear relationship between the monolayer compression speed u and the molecular area Am. Compression speed a was about 30, 40, 50mm/min. Langmuir-Blodgett(LB)layers of Arachidic acid deposited by LB method were deposited onto slide glass as Y-type film. The structure of manufactured device is Au/Arachidic acid/Al, the number of accumulated layers are 9$\sim$21. Also, we then examined of the Metal-Insulator-Metal(MIM) device by means of I-V. The I-V characteristics of the device are measured from -3 to +3[V]. The insulation property of a thin film is better as the distance between electrodes is larger.

Electrical Characteristic of a Suspended Porcelain Insulator with a 154 kV Transmission Line (154 kV 송전선로 자기재 현수 애자의 전기적 특성 규명에 관한 연구)

  • Jeon, Seongho;Choi, In-Hyuk;Kim, Taeyong;Lee, Youn-Jung;Koo, Ja-Bin;Son, Ju-Am;Yi, Junsin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.1
    • /
    • pp.56-59
    • /
    • 2020
  • Porcelain insulators are typically exposed to surface discharge and lightning impulse in service. This study investigates the insulation characteristics of the external and internal discharges of a porcelain insulator with respect to its flashover for a 154 kV transmission line. The experiments are also conducted using a wet flashover test and an impulse test based on the external discharge and the internal penetration, to classify the flashover voltage-time curve of the porcelain insulator. When an impulse with a strength of 2,500 kV/㎲ was applied three times to 6.5 mm ceramic samples, electrical penetration of approximately 70% occurred. The impulse experiment confirmed that the electrical penetration inside the porcelain insulator coincided with the area where the electric field was concentrated. The wet flashover voltage test revealed that the flashover threshold voltage increases by approximately 7% after cleaning of the surface.