• 제목/요약/키워드: utility line

검색결과 308건 처리시간 0.023초

Smoothing Output Power Variations of Isolated Utility Connected Multiple PV Systems by Coordinated Control

  • Datta, Manoj;Senjyu, Tomonobu;Yona, Atsushi;Sekine, Hideomi;Funabashi, Toshihisa
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.320-333
    • /
    • 2009
  • A Photovoltaic (PV) system's power output varies with the change of climate. Frequency deviations, tie line voltage swings are caused by the varying PV power when large PV power from several PV systems is fed in the utility. In this paper, to overcome these problems, a simple coordinated control method for smoothing the variations of combined PV power from multiple PV systems is proposed. Here, output power command is formed in two steps: central and local. Fuzzy control is used to produce the central smoothing output power command considering insolation, variance of insolation and absolute average of frequency deviation. In local step, a simple coordination is kept between the central power command and the local power commands by producing a common tuning factor. Power converters are used to achieve the same output power as local command power employing PI control law for each of the PV generation systems. The proposed method is compared with the method where conventional Maximum Power Point Tracking (MPPT) control is used for each of the PV systems. Simulation results show that the proposed method is effective for smoothing the output power variations and feasible to reduce the frequency deviations of the power utility.

CAD 수단을 이용한 벡터형 공간자료의 위상 검출과 격자도면화를 위한 유틸리티 개발 (Development of a CAD-based Utility for Topological Identification and Rasterized Mapping from Polygonal Vector Data)

  • 조동범;임재현
    • 한국조경학회지
    • /
    • 제27권4호
    • /
    • pp.137-142
    • /
    • 1999
  • The purpose of this study is to develope a CAD-based tool for rasterization of polygonal vector map in AutoCAD. To identity the layer property of polygonal entity with user-defined coordinates as topology, algorithm in processing entity data of selection set that intersected with scan line was used, and the layers were extracted sequentially by sorted intersecting points in data-list. In addition to the functions for querying and modifying topology, two options for mapping were set up to construct plan projection type and to change meshes' properties in existing DTM data. In case of plan projection type, user-defined cell size of 3DFACE mesh is available for more detailed edge, and topological draping on landform can be executed in case of referring DTM data as an AutoCAD's drawing. The concept of algorithm was simple and clear, but some unexpectable errors were found in detecting intersected coordinates that were AutoCAD's error, not the utility's. Also, the routines to check these errors were included in algorithmic processing. Developed utility named MESHMAP was written in entity data control functions of AutoLISP language and dialog control language(DCL) for the purpose of user-oriented interactive usage. MESHMAP was proved to be more effective in data handling and time comparing with GRIDMAP module in LANDCADD which has similar function.

  • PDF

향상된 고조파 검출 능력을 갖는 계통연계 인버터의 하이브리드 단독운전 방지기법 (A Hybrid Anti-islanding Detection Scheme for Utility Interactive Inverter with Enhanced Harmonic Extraction Capability)

  • 강성욱;김경화
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.312-319
    • /
    • 2014
  • When distributed generation such as a wind power system is connected to the grid, it should meet grid requirements like IEEE Std. 1547, which regulates the anti-islanding method. Since the islanding may cause damage on electrical equipments or safety hazards for utility line worker, a distributed generation should detect it as soon as possible. This paper proposes a hybrid anti-islanding method coupled with the active and passive detection methods. To enhance the harmonic extraction capability for an active harmonic injection method, cascaded second-order band-pass filter and signal processing scheme are employed. Simulation and experiments are carried out under the islanding test condition specified in IEEE Std. 1547. Passive over/under voltage and over/under frequency methods are combined with the active method to improve the detection speed under certain condition. The simulation and experimental results are presented to verify that the proposed hybrid anti-islanding method can effectively detect the islanding.

다중 채널 EPD제어기의 개발 (Development of multiple channel EPD controller)

  • 최순혁;차상엽;이종민;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1500-1503
    • /
    • 1997
  • In this paper a multiple channel EPD controller is developed which enables us to detect endpoints simultaneously in the plasma etching process operated in multiple etching chambers and its performance characteristic are investigated. for the accurate detectiion of endpoint the developed EDP controller was able to implement endpoint detectiions by integrating the existing EPD controllers with the techiques of artificial intellignet, to enhance its performance. The performance of the developed EPD controller was carried out by repeated experiments of endpoint detection in the acrual production line of semiconductor manufacturing. It's utility for endpoint detectiion was accurately evaluated in various etching process. The control capability of multiple etching chambers enhances its application compared with the existing one, and also increases the user utility os that the efficiency of operation was improved.

  • PDF

반복제어기를 적용한 단상 계통연계형 인버터의 전력품질 개선 (Improvement of Power Quality of Single-phase Utility Interactive Inverter using Repetitive Controller)

  • 김재한;목형수;최규하;이진우;정교범;이정민;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.11-14
    • /
    • 2007
  • In recent years, installation of the new and renewable energy system is rapidly increasing. Because the new and renewable energy system is a practical distributed generation system to save energy resources and to keep environments clean. Conventional single-phase utility interactive inverter controls output current by using PI current controller. However, this method is insufficient to suppress harmonic current resulted from nonlinear loads in grid line. In this paper, in order to suppress periodic waveform distortion and improve THD(Total Harmonic Distortion), new type current controller added a parallel repetitive controller is proposed and then performance of the proposed controller was verified with computer simulation.

  • PDF

독립운전기능을 갖는 계통연계형 태양광 발전시스템의 설계 (Design of Grid Connected Photovoltaic System with Stand-alone Operation)

  • 김말수;이상훈;홍종석;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.969-972
    • /
    • 2003
  • This paper deal with a necessary factors for design grid connected photovoltaic system with stand-alone operation, and show simulation results of individual functions and multi- operation according to utility condition. Generally, photovoltaic system have only one operation of either stand-alone or line interactive, and have a isolation transformer for electrical isolation from utility therefore it is bulky, weighty, and a high price system as compared with usefulness. In this paper, A topology and algorithm adequate for lightweight, high efficiency, low price, multi function is selected and inquired into the validity using simulation of variable conditions.

  • PDF

전력설비에 의한 자계 측정및 컴퓨터 시뮬레이션 (Magnetic Field Measurement and Computer Simulation for Electrical Utility Facilities)

  • 전형태;사재원;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.22-24
    • /
    • 1996
  • For two decades and more, a lot of research work on the biological effects of EMF(Electromagnetic Fields) on Human hearth have been reported. Power-frequency magnetic fields are a natural consequence of the flow of electricity. This paper deals with the modeling of electric utility facilities taking into account the line geometries. The magnetic fields profiles obtained from the computer simulation arc compared to those from measurements.

  • PDF

초전도 사고전류제한기를 설치한 독립배전계통의 고장상태해석 (Fault simulation of distributed power system with superconducting fault current limiter)

  • 이상진;오윤상;배준한;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.122-124
    • /
    • 1995
  • Electrical transmission and distribution networks must withstand an occasionally abnormal condition such as a fault, with prejudicial consequences for the line, transformers or generators. And the improvement of reliability and quality of the delivered power from an electric utility motivates the development of new technologies in power applications. As a part of these studies, the usefulness and utility of a superconduction fault current limiter(SFCL) are shown. The SFCL is applied to 22.9KV three-phase power system and performed short circuit studies. The verified quench characteristic of SFCL is adopted for fault simulation and the results are compared with those of system which have not SFCL.

  • PDF

낙뢰로부터 전력설비 보호를 위한 한전의 절연설계 기준 (Insulation Design Standards for Protection of Power System against Lightning in Korea Electric Power Corporation)

  • 우정욱;문재덕
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.555-560
    • /
    • 2006
  • As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages account for 33.7 percent of total lightning faults from 1996 to 2004. Even though transmission fault might be cleared shortly by protective system, it could deteriorate the power quality accompanied with sag or flicker. Moreover, double circuit fault may lead to more aggravated situation, for instance, blackout. To Protect transmission lines from lightning stroke, reduction of tower footing resistance, multiple ground wires and unbalanced insulation in double circuit lines have been adopted. In this paper, we would like to introduce insulation design standards for lightning protection of Korea Electric Power Corporation.

DC전철구간의 회생인버터시스템 개발 (Development of Regeneration Invertor System for DC Electric Railway System)

  • 김용기;김주락;한문섭;김준구;양영철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.505-511
    • /
    • 2008
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The purpose of this study was the development of the regenerative inverter system which suppress extra DC-line voltage and regenerate the energy instead of using a resister. That is Developed regenerative inverter system returns the regenerative energy from the DC line voltage to the utility. In addition, the inverter can be compensate the harmonics caused by the power conversion devices used in the DC traction system.

  • PDF