• Title/Summary/Keyword: usage charge

Search Result 141, Processing Time 0.028 seconds

Improved Prediction of Coreceptor Usage and Phenotype of HIV-1 Based on Combined Features of V3 Loop Sequence Using Random Forest

  • Xu, Shungao;Huang, Xinxiang;Xu, Huaxi;Zhang, Chiyu
    • Journal of Microbiology
    • /
    • v.45 no.5
    • /
    • pp.441-446
    • /
    • 2007
  • HIV-1 coreceptor usage and phenotype mainly determined by V3 loop are associated with the disease progression of AIDS. Predicting HIV-1 coreceptor usage and phenotype facilitates the monitoring of R5-to-X4 switch and treatment decision-making. In this study, we employed random forest to predict HIV-1 biological phenotype, based on 37 random features of V3 loop. In comparison with PSSM method, our RF predictor obtained higher prediction accuracy (95.1% for coreceptor usage and 92.1% for phenotype), especially for non-B non-C HIV-l subtypes (96.6% for coreceptor usage and 95.3% for phenotype). The net charge, polarity of V3 loop and five V3 sites are seven most important features for predicting HIV-1 coreceptor usage or phenotype. Among these features, V3 polarity and four V3 sites (22, 12, 18 and 13) are first reported to have high contribution to HIV-1 biological phenotype prediction.

A Windows-based Software for Education and Training of Transmission Network Charge (송전망 이용요금 산정을 위한 교육용 시뮬레이터 개발)

  • Kim, Hyun-Houng;Cho, Ki-Seon;Jeong, Yun-Won;Park, Jong-Bae;Shin, Joong-Rin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1373-1381
    • /
    • 2007
  • This paper presents a graphical windows-based software for the education and training of transmission network charge. The motivation for the development of the simulator is to provide students with a simple and useable tool for gaining an intuitive feel for transmission network charge. The developed simulator consists of the main module (MMI, GUI), the power flow module (PF), the power flow tracing module (PFT), and usage cost DB module (UCD). Each module has a separate graphical and interactive interfacing window. The developed simulator provides with two power system analysis methods (i.e., DC-PF and Modified DC-PF) and supports the PSS/E input data format to load input data of power system. Also, power flow tracing can be calculate using four methods such as "Felix Wu", "Modified Felix Wu", "DCLF ICRP", and "Reverse MW mile". Results of calculation for transmission usage cost are displayed and compared on the window through the table and/or chart. Therefore, the developed simulator can be utilize as a useful tool for effective education and training of transmission network charge.

A Study on ESS Optimal Operation Strategy Using Two Stage Hybrid Optimization (Two Stage Hybrid Optimization을 사용한 ESS 최적 운전 전략에 대한 연구)

  • Gong, Eun-Kyoung;Sohn, Jin-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.833-839
    • /
    • 2018
  • This paper presents an analysis and the methodology of optimal operation strategy of the ESS(Energy Storage System) for reduce electricity charges. Electricity charges consist of a basic charge based on the contract capacity and energy charge according to the power usage. In order to use electrical energy at minimal charge, these two factors are required to be reduced at the same time. QP(Quadratic Programming) is appropriate for minimization of the basic charge and LP(Linear Programmin) is adequate to minimize the energy charge. However, the integer variable have to be introduced for modelling of different charge and discharge efficiency of ESS PCS(Power Conversion System), where MILP(Mixed Integer Linear Programming) can be used. In this case, the extent to which the peak load savings is accomplished should be assumed before the energy charge is minimized. So, to minimize the electricity charge exactly, optimization is sequentially performed in this paper, so-called the Two Stage Hybird optimization, where the extent to which the peak load savings is firstly accomplished through optimization of basic charge and then the optimization of energy charge is performed with different charge and discharge efficiency of ESS PCS. Finally, the proposed method is analyzed quantitatively with other optimization methods.

An Approach to Allocating Transmission System Reliability Cost (송전계통의 신뢰도 비용 배분 방만에 대한 연구)

  • Jeong, Gu-Hyeong;Sin, Yeong-Gyun;Kim, Bal-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.4
    • /
    • pp.183-187
    • /
    • 2002
  • The efficient and rational transmission tariff structure is one of the crucial factors in creation of fair and competitive electricity markets. Transmission charge can be largely categorized into the line usage charge, system reliability charge, access charge and others. Any transmission tariff should be able to reflect these cost components reasonably. This paper suggests an approach amenable to allocating the transmission reliability costs reasonably with reflection of line sensitivity and line outage rate.

Educational Simulator for Transmission Network Use of System Charge (송전망 이용요금산정을 위한 교육용 시뮬레이터 개발)

  • Kim, H.H.;Song, H.Y.;Lee, C.J.;Park, J.B.;Shin, J.R.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.201-203
    • /
    • 2006
  • This paper presents a graphical windows-based software for the education and training of the transmission network use of system charge. The developed simulator consist of the main module(MMI,GUI), the power flow module(PF), the power flow tracing module(PFT) and management of usage cost DB module(UCD). Each module has a separate graphical and interactive interfacing window. To have effective education for transmission network use of system charge, the developed simulator are provided with two power system analysis methods. Input data of power system can use the format of PSS/E input data. Also calculation of power flow tracing are provided with four methods such as "Felix Wu","Modified Felix Wu", "DCLF ICRP" and "Reverse MW mile". Results of calculation for usage cost are shown on the window through the table or chart. Therefore user can confirm the detailed differences of results from each calculation method.

  • PDF

단결정 태양전지의 시정수

  • Jeong, Yu-Ra;Choe, Yong-Seong;Lee, Gyeong-Seop
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.11-11
    • /
    • 2010
  • Recently, annual usage of energy is dramatically increasing by industrialization is going faster and more electricity is needed due to various electronic devices. This paper present relationships between the Vmax, $V_T$, load and time constant of solar cell charge and discharge curve. Charging and discharging recording where the external resistance will become larger Vmax, $V_T$ is decrease and the time increases and decreases there is a possibility of knowing.

  • PDF

An Analysis on the Charge Distribution on the Spacer Using Dust Figure (Dust Figure를 이용한 스페이서상의 대전전하 분포해석)

  • Choi, Jae-Gu;Seo, Kil-Soo;Kim, Young-Bae;Kim, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1681-1683
    • /
    • 1998
  • Unlike AC, DC dielectric characteristics of the spacer are very influenced by the quantity and the distribution of surface charges. A general impression of the distribution of surface charges is obtained if electrostatic powders are sprinkled over the surface. The distribution of surface charge was investigated with dust figures. Mechanism of charge accumulation on the spacer of $SF_6$ GIS has been studied using various types of model spacers which have different depths. As a result, it was found that charge accumulation was dominantly influenced by the normal component of the electric field and the usage of embedded electrodes was an adequate method to lessen field concentration around the triple junction. The guide of the optimum depth of the spacer was proposed.

  • PDF

An Approach To Alloctating Transmission System Reliabity Cost (송전계통의 신뢰도 비용 산정 방안에 대한 연구)

  • Chung, Koo-Hyung;Shin, Young-Kyun;Kim, Bal-Ho H.;Im, Sung-Hwang
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.515-517
    • /
    • 2001
  • The efficient and rational transmission rate system is one of the crucial factors in creation of fair and competitive electricity market. Transmission charge can be largely categorized into the line usage charge, system reliability maintenance charge, access charge and others. Therefore, transmission rate structure should be able to reflect these cost components reasonably. This Paper suggests an approach that could be used for the reasonable calcuation of transmission reliability costs with reflection of line sensitivity and line outage rate.

  • PDF

A Study on the Use of Rural Community Tourism Information Services via Smartphones -Focused on The Theory of Planned Behavior-

  • Ko, Eun Kyo;Lee, Seung Hyun
    • International Journal of Contents
    • /
    • v.10 no.2
    • /
    • pp.28-36
    • /
    • 2014
  • This study attempted to suggest a strategy for providing rural community tourism information services using smartphones. Study subjects were men and women among 300 who currently use smartphones. Empirical analysis was done on 249 of the 300 subjects. Upon verification of the effect factors of adults' smartphone usage and rural community tourism information services usage, they were both statistically significant based on Ajzen's(1991) Theory of planned behavior. Hence, behavior, subjective norms, perceived behavioral control should be augmented in order to increase smartphone usage behavior to access rural community tourism information services. Especially, behavioral intent and usage behavior was increased proportionately to behavioral control. We suggested that plans to provide applications free of charge and building a social consensus on utilizing rural community tourism information are important in achieving such status.

An Empirical Study on the Flow Experience Affected by Characteristics of Mobile Internet (모바일 인터넷 특성이 플로우 경험에 미치는 영향에 관한 연구)

  • Yoo, Sang-Jin;Choi, Eun-Bin;Kim, Hyo-Jung
    • Information Systems Review
    • /
    • v.8 no.1
    • /
    • pp.125-139
    • /
    • 2006
  • Recently, as mobile internet users grow rapidly, mobile internet companies are experiencing a fierce competition to capture new customers. Under this business environment, they try to identify factors that make people use mobile internet in order to satisfy customers by providing better and diversified services. There has been enormous effort to analyze customers' behavior in choose and use mobile internet services. However, there is no one best methodology to identify factors to attract customers yet. Thus, the study applied the flow construct proposed by Csikszentmihalyi(1977) and expanded by Hoffman and Novak(1996) to identify environmental factors of internet which has impact on users' mobile internet usage. To implement the study, the following activities have been done: literature reviews on service acceptance model and flow structure, questionnaire survey, suggestion of the flow model on mobile internet, and hypothesis test. For the study, 242 out of 307 samples collected were statistically analyzed using SPSS 10.0, AMOS 4.0 statistics package. The findings of this study are as follows: First, mobile internet environment factors influencing on challenge of flow antecedent were media characteristics(use of convenience, transmission quality), contents characteristics(uniqueness, timeliness, simplicity). Second, mobile internet environment factors influencing on skill of flow antecedent were contents(uniqueness, timeliness, simplicity), charge(definiteness and diversity of charge), usage(security, instant connectivity). Third, challenge of flow antecedent had a significant effect on flow of mobile internet usage. But it was not statistically significant that skill has an influence on flow. This study discovered the relationship between mobile internet environment factors(media characteristics, contents characteristics, charge characteristics, usage characteristics) and flow experience of mobile internet users which would be a valuable insight for marketing strategies. Results shows that challenge of flow antecedent have a significant impact on flow experience in mobile internet environment. Additional, media characteristics, contents characteristics of mobile internet environment factors is positively correlated with challenge of flow antecedent. In other words, mobile internet companies should provide customers with diverse service and take a challenging attitude to get customers show aggressive attitude in mobile internet usage.