• 제목/요약/키워드: urodynamic monitoring system

검색결과 4건 처리시간 0.04초

요역동학 측정시스템을 위한 새로운 복압측정 기법 (A New Approach Method of Measuring Abdominal Pressure for Urodynamic Monitoring System)

  • 서정환;김거식;안양수;김경섭;송철규
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1170-1176
    • /
    • 2007
  • The conventional urodynamic monitoring is fulfilled by artificially filling a bladder with saline. Generally. it is difficult to evaluate the physiological functions of the storage and voiding of a bladder. With this aim, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method estimating abdominal pressure by measuring bio-impedance variations. Our system was clinically evaluated for 10 patients. It turned out to be that as the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased more as compared to those who observed during the rest mode. Also, we determined the optimum electrode pair for estimating the abdominal pressure using bio-impedance method and consequently compared with the conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified in terms of impedance change, correlation coefficient and SNR Our results showed the optimum electrode pair (1,9) which could detect impedance changes due to the increase of the intensity in the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. Thus, our system demonstrated that the abdominal pressure could be measured noninvasively and conveniently by simply estimating bio-impedance values. We propose that this optimum electrode configuration would be useful for the future studies involving the handy measurements of abdominal pressure with our suggested ambulatory urodynamics monitoring system.

휴대용 하부요로기능 검사 장치의 설계 (Design of ambulatory urodynamics monitoring system)

  • 이상옥;김거식;윤대영;서정환;송철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.48-50
    • /
    • 2005
  • Urodynamics describes a collection of tests designed to evaluate lower urinary tract function and can be performed using retrograde filling of the bladder within a room. In this study, we designed and calibrated the potable urodynamics monitoring system using DSP chip (TMS320VC33, Texas Instrument$^{TM}$, U.S.) and collected pressure and EMG using calibration kit (DPT9022K0122, Medtronics$^{TM}$, U.S.). This system can make patients more comportable and monitor spontaneous urination during daily life.

  • PDF

배뇨력 측정을 통한 하부요로계의 보상성기능항진 평가 (Estimation of compensatory hypertrophy in lower urinary system using void force measurement)

  • 정도운;전계록
    • 센서학회지
    • /
    • 제15권6호
    • /
    • pp.449-456
    • /
    • 2006
  • The purpose of urodynamic investigation is to obtain the information on the function of the urinary system. The aim of this study is to acquire the useful information of lower urinary tract symptom (LUTS) diagnosis through void force signal as noninvasive method. The system which could evaluate the function of compensatory hypertrophy with noninvasive and comfortable method was implemented to measure uroflow and void force during urination. The implemented system composes of the sensor parts, signal conditioning parts and PC monitoring program. For the evaluation of the implemented system, the simulation of control part of the system was performed and the model system for the lower urinary system was designed. The superiority of a measuring characteristic of the implemented system was verified using the model system. From the evaluation of the model system, we have found out that the void force was dependent on the occlusion degree and compensatory hypertrophy significantly.

FPGA를 이용한 LUTS 진단 시스템 구현 및 평가 (Implementation and Evaluation of the LUTS Diagnosis System Using FPGA)

  • 정도운;정완영;전계록
    • 융합신호처리학회논문지
    • /
    • 제8권1호
    • /
    • pp.6-14
    • /
    • 2007
  • 요역동학검사는 하부요로계의 이상증상을 진단하기위하여 수행된다. 일반적으로 임상에서 행해지는 요역동학검사에서는 침습적인 방법으로 방광을 채운 후 배뇨하는 절차를 거친다. 하지만 이러한 방법은 카테터를 삽입해야하므로 환자에게 고통을 수반하게 한다. 본 연구에서는 비침습적이고 보다 편리한 방법으로 하부요로계의 기능을 평가할 수 있는 시스템을 구현하고자 하였다. 비침습적인 방법으로 하부요로증상(lower urinary tract symptoms, LUTS)의 진단을 위하여 배뇨시 요속, 요류음, 비침습적 방광내압을 측정할 수 있는 시스템을 구현하였다. 구현된 시스템은 센서부, 신호처리부, FPGA를 이용한 시스템 제어부 그리고 PC모니터링 프로그램으로 구성하였다. 그리고 구현된 계측시스템의 평가를 위하여 FPGA 시스템 제이부의 시뮬레이션을 수행하였고 인체의 하부요로계를 모식화한 실험장치를 구현하였다. 실험장치를 이용한 측정부의 평가결과 요속측정부의 평균에러율이 1.08%, 계수변화율이 1.48로 평가되었다. 그리고 비침습적 방광내압부는 평균에러율이 2.41%, 계수변화율이 2.81로 나타났다. 요류음신호의 시간영역과 주파수영역에서의 분석위해 평균실효치전력(average RMS power)과 주파수영역에서의 중심주파수(median frequency, MF)를 분석하였으며, 그 결과 $60{\sim}160Hz$의 중심주파수대에서 폐색을 가장 잘 반영하였다.

  • PDF