• Title/Summary/Keyword: urban apartments

Search Result 185, Processing Time 0.028 seconds

Study on Exterior Color of Apartments in Seoul for the Color Environment (색채 환경을 고려한 서울시 아파트 외관 색채 계획에 관한 연구)

  • Yi, Young-Ran;Chu, Beom
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.2
    • /
    • pp.143-150
    • /
    • 2016
  • Color plan that contains corporate color of Seoul apartment has a great influence on city environment, considering high-rise vertical dispersion and extent. Therefore, it is necessary to view color plan from an integrative viewpoint. Here, this research aimed at deriving guideline factors of esthetic color plan based on city identity, by recognizing the importance of apartment color and color plan characteristic of recently built brand apartments. Exterior color plan characteristic of Seoul brand apartments seen in this research, first, most of dominance colors were in same color similar tone with warm color in bright and warm image, as the psychological function, accessory colors appeared in similar tone of similar color harmonious with the dominance color. Also, accent color was highlighted with its identity through cooperative color. Second, emotional effect diminished size and weight of high-rise apartment. The upper levels showed clear and clean image, middle to lower level showed stability and comfortable image, on the whole, refined and urbane image that aim for natural and modern image. Therefore, apartment color plan requires, first, in respect of dominance color, unity is required proper for urban image by preparing color permission limitation standard. Second, dominance color and accessory color require historicity and differentiation in sociality that urban identity gets. Third, high-rise upper level cooperative color accent color requires compatibility with urban landscape. Lastly, guideline along with rate is required for color, tone, and pattern, etc. by extent contrast. Here, apartment color plan requires consistent research as urban environment color, also, base study should be accelerated as a part of competitive city branding.

A Study on the Microbial Air Pollution of Urban Living and Indoor Environment (생활환경과 실내공기의 미생물학적 오염에 관한연구)

  • 정윤희;홍준배;장윤희
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.1-9
    • /
    • 2001
  • This study was carried out to investigate the microbial characteristics of the urban air pollution in the subway stations, streets, department stores, wholesale markets, underground shopping centers, buildings, parks, houses and apartments in the Seoul and the suburbs area. Total cell count, total mold count and the presence of opportunistic pathogens(Streptococcus pneumoniae, Klebsiella pneumoniae, Aspergillus spp., Penicillium spp.) were evaluated determine the microbial air quality. Total cell count and mold count of indoor air in the houses and apartments were 2.9$\times$10$^2$-6.3$\times$10$^2$cfu/㎥ and 60-1.8$\times$10$^2$cfu/㎥, respectively, and the department stores and wholesale markets had much lower cell count than the houses and apartments. Ground level of commercial stations were 2.6 fold higher than the general subway stations, and Apergillus spp. and Penicillium spp. which could cause the bronchus and lung diseases were detected 17 sampling site out of 45. Dust were collected from the commercial facilities and houses, and total cell and mold count of the dust were 4.3$\times$10$^3$-1.7$\times$10$^{6}$ cfu/g and 2.3$\times$10$^3$-6.5 $\times$10$^4$cfu/g, respectively. Therefore the dust might be one of the main reservoir of microorganims.

  • PDF

Analysis of Heating and Cooling Energy Consumption in Rental and Sales Apartments in Busan (부산시 임대아파트 및 분양아파트의 냉난방에너지 소비량 분석)

  • Lee, Kyung-Hee;Lee, Jun-Gi
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.79-85
    • /
    • 2021
  • This study analyzed the energy consumption differences between rental and owner owned (purchased) apartments in Busan, South Korea during the cooling and heating seasons. Analysis revealed that the average electricity consumed for cooling was 2.5 kWh/m2·yr for rental apartments and 2.3 kWh/m2·yr for purchased apartments, a difference of 0.2 kWh/m2·yr. The average electrical heating energy consumption was 3.3 kWh/m2·yr for rental apartments and 2.2 kWh/m2·yr for purchased apartments, a difference of 1.1 kWh/m2·yr. It was estimated that the use of electric blankets and heaters was higher in rental apartments than purchased apartments resulting in higher electrical heating energy consumption. The average gas heating energy consumption was 7.0 kWh/m2·month for rental apartments and 6.8 kWh/m2·month for purchased apartments. When electricity and gas usage was combined for heating, the average total heating energy consumption was 10.3 kWh/m2·month for rental apartments and 9.0 kWh/m2·month for purchased apartments. This indicates that rental apartments consume 1.3 kWh/m2·month more energy than purchased apartments during heating season. Overall, rental apartments consume more energy than purchased apartments during both the cooling and heating seasons.

A Study of the Living Modes in the Unit Spaces of the Rural Apartment Houses (농촌공동주택 단위공간내 주생활방식에 관한 조사연구)

  • Min, Yang-Kwan;Cho, Il-Howan;Choi, Hyo-Seung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.1 no.2
    • /
    • pp.39-51
    • /
    • 1999
  • This study aims to obtain new design factors in terms of constructing rural apartment houses fit for the actual farm life. To carry out this study, field studies and personal interviews have been made on the living mode and using realities in the unit spaces of the rural apartment houses. The houses surveyed are the rural apartments in Chungbuk Province which were built by the public program to improve old farm houses. The results are as follows. The living modes .in the unit spaces of the rural apartments are very similar to those of the urban apartment houses. But compared with the urban indoor-living modes, the rural life is keeping more of the traditional sitting way-of-living. Accordingly, it is quite necessary to consider the nature of farm life and the sitting way-of-living in designing the rural apartment houses.

  • PDF

A Study on the Life Style and the Interior Preference of Urban Residents in Apartments (도시 아파트거주자의 주생활양식과 실내분위기 선호 연구)

  • 박영순
    • Journal of the Korean housing association
    • /
    • v.5 no.1
    • /
    • pp.17-27
    • /
    • 1994
  • The Purpose of this study is to classify the life styles of urban residents in apartments and to find out possible correlation with their preferences on interior ambience.The selected samples were 3,000 residents from Seoul, Pusan, Kwaungju and Cheonan, and 2,750 of them were analyzed.'The results can be summarized as follows.1.The life style patterns were classified into S types, namely organized type, decoration-oriented type, self expression type, practicality-oriented type and fashion-oriented type. 2. Interior image were classified into 4 types, namely characteristic image, contemporary image, classic image and rich image.3. The interior preference was correlated with the life style patterns, such as organizd type preferred to contemporary image, decoration-oriented type preferred to rich image, self expression type preferred to classic image and practicality-oriented type preferred to characteristic type.4. The patterns of life style and the interior preference differed significantly according to the size of apartment and the age of owner.

  • PDF

A Study on the Vertical Flue Duct for Application of Small Wind Power System in High-Rise Apartments (초고층 공동주택의 소형풍력발전시스템 적용을 위한 수직연도 활용에 관한 연구)

  • Kim, Seong-Yong;Lee, Yong-Ho;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.116-125
    • /
    • 2011
  • This study examined vertical shafts in high-rise apartments of the old high-rise buildings, reviewed the possibility of using flue ducts, and analyzed airflow patterns according to pressure differences between in and out side of flue ducts through computational fluid dynamics(CFD). The resulting conclusions are as follows: 1) The analysis results of airflow according to the stack effect of flue ducts show that smaller-diameter flue ducts(${\phi}1.2m$) would be morefavorable in increasing downward wind velocity than bigger-diameter ones(${\phi}1.6m$) and that the introduction ducts for outside air should be more than 50% of flue duct diameter to obtain a downward wind velocity higher than $3.0^m/s$ that is the minimum blade wind velocity of a small domestic wind generator. 2) The optimal installation location of a bypass introduction duct is the neutral plane of a flue duct or lower. When the diameter of the upper duct is bigger than that of the lower duct, it will generate more effects on the increase of downward wind velocity in flue ducts.

An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment (도심 임대아파트의 에너지 및 상수 소비 특성에 관한 연구)

  • Seo, Youn-Kyu;Kim, Ju-Young;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.20 no.6
    • /
    • pp.39-46
    • /
    • 2009
  • It has been a serious problem to consume the energy of apartment while increasing to use of heating & cooling System because of residence environmental upgrades. Great attention has been shown to the problem of the rental apartment, so there are few reports of energy consumption about the rental apartment in korea. To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072\;m^2$ per year and typical energy consumption unit was $604.2\;MJ/m^2$ on $74.4\;m^2$ of area and $448.8\;MJ/m^2$ on $105.8\;M^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an typical energy consumption unit standard through this research, apartments should use energy more efficiently.

Present Condition and Preferences on Design Factors for Well-Being Apartments (웰빙아파트 계획요소의 도입현황과 선호도)

  • Choi, Yoon-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.49-52
    • /
    • 2006
  • The purposes of this study were to summarize the concept of well-being and well-being apartment, to grasp the present condition of apartments which were introduced with well-being factors, and to find out the consumer preferences of design factors for well-being apartment. Library and internet surveys were performed to summarize the concept of well-being and well-being apartment and to grasp the present condition of apartments which were introduced with well-being factors. Questionnaire survey was carried out from 2nd to 22nd of June 2005, to investigate the preferences of design factors for well-being apartment, and the respondents were 250 residents living in urban area. As major result, the design factors haying the preference were revealed as complex design, sports & health facility, and interior surface materials.

  • PDF

Estimating Door Open Time Distributions for Occupants Escaping from Apartments

  • Hopkin, Charlie;Spearpoint, Michael;Hopkin, Danny;Wang, Yong
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.73-83
    • /
    • 2021
  • The door open time, resulting from occupants evacuating from apartments, is an important parameter when assessing the performance of smoke ventilation systems in high-rise apartment buildings. However, the values recommended in UK design guidance appear to have limited substantiation. Monte Carlo simulations have been carried out considering variabilities in door swing time, flow rate and number of occupants. It has been found that the door open time can be represented by a lognormal distribution with a mean of 6.6, 8.7 and 11.1 s and a standard deviation of 1.7, 3.2 and 4.7 s for one, two and three-bedroom apartments, respectively. For deterministic analyses, it is proposed that the 95th percentile values may be adopted in line with recommended practice for other fire safety design parameters such as fuel load density and soot yield, giving door open times of 10 s to 19 s, depending on the number of bedrooms.

Development and Application of an Evaluation Model for Urban Biotope Appraisal (도시 비오톱의 자연체험 가치 평가모형의 개발과 적용)

  • 나정화;류연수
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.3
    • /
    • pp.1-11
    • /
    • 2002
  • The purpose of this study is to construct an evaluation criteria based on the relative importance and various combinations of each evaluation index and then to appraise urban biotope in terms of nature experience and recreation. After the standard of evaluation had been developed through the review of existing literature, the relative importance of the evaluation index through expert survey was determined, and the evaluation model to assess biotope value was established. The results of this study are as follows; 1) We have constructed the seventeen evaluation criteria through literature reviews, and have provided relative importance to each evaluation index of the natural in biotope, the diversity of landscape patterns, the appearance-existence of water space, the special landscape elements, and the access based on the results of expert survey. and then we have constructed an evaluation system using the relative importance criteria. 2) To evaluate urban biotope using the evaluation system constructed, we selected 14 sites. The final evaluation results of each site is as follows; The first grade areas are the water space with semi-natural style in front of Gangchon Woobang apartments, the forest zone near Page Temple at Mt. Palgong, the edge area of Jisan and Gosan and the tendril yard against Anshim middle school. The second grade areas are Hyomyung elementary school, the farm land behind the third Anshim Jugong apartment, Ehyun put and the swampy land in front of the Kangchon and Anshim construction site. The third grade areas are Seohan and Hwasung high-rise apartments at Beummul-Dong, the Korea Manpower Agency in the Sungseo industrial zone, and the adjacent area of St. Tongil. The only fourth grade area is the commercial zone near Taegu Department Store. 3) It is highly useful to evaluate urban biotope using the evaluation criteria constructed for this research, the evaluation criteria we developed may be difficult to encompass all expert opinion and the period of space-formation is difficult to estimate urban biotopes. In the future, it is necessary to gather the basic data suitable to estimate biotope and it is necessary to develop detailed evaluation criteria applicable to estimate every biotope that has specific property.