• 제목/요약/키워드: uplift performance

검색결과 51건 처리시간 0.029초

Seismic behavior of liquid storage tanks with 2D and 3D base isolation systems

  • Kilic, Samet;Akbas, Bulent;Shen, Jay;Paolacci, Fabrizio
    • Structural Engineering and Mechanics
    • /
    • 제83권5호
    • /
    • pp.627-644
    • /
    • 2022
  • In past major earthquakes (1994 Northridge, 1995 Kobe, Chi-Chi 1999, Kocaeli 1999), significant damages occurred in the liquid storage tanks. The basic failure patterns were observed to be the buckling of the tank wall and uplift of the anchorage system. The damages in the industrial facilities and nuclear power plants have caused the spread of toxic substances to the environment and significant fires. Seismic isolation can be used in liquid storage tanks to decouple the structure and decrease the structural demand in the superstructure in case of ground shaking. Previous studies on the use of seismic isolation systems on liquid storage tanks show that an isolation system reduces the impulsive response but might slightly increase the convective one. There is still a lack of understanding of the seismic response of seismically isolated liquid storage tanks considering the fluid-structure interaction. In this study, one broad tank, one medium tank, and one slender tank are selected and designed. Two- and three-dimensional elastomeric bearings are used as seismic isolation systems. The seismic performance of the tanks is then investigated through nonlinear dynamic time-history analyses. The effectiveness of each seismic isolation system on tanks' performance was investigated. Isolator tension forces, modal analysis results, hydrodynamic stresses, strains, sloshing heights and base shear forces of the tanks are compared. The results show that the total base shear is lower in 3D-isolators compared to 2D-isolators. Even though the tank wall stresses, and strains are slightly higher in 3D-isolators, they are more efficient to prevent the tension problem.

열사이펀의 열성능 산정을 위한 수치해석 연구 (Evaluation on Thermal Performance of Thermosyphon by Numerical Analysis)

  • 장창규;최창호;이장근;이철호
    • 한국지반공학회논문집
    • /
    • 제30권9호
    • /
    • pp.57-66
    • /
    • 2014
  • 동토지역에서는 계절변화에 상관없이 항시 영하상태로 동결되어 있는 영구동토층과, 그 위로 동결융해가 반복되는 활동층으로 구성되어있다. 일반적으로 대기온도 변화에 따라 동결융해가 반복되는 활동층은 얼음과 물의 상변화 작용이 반복되기 때문에 지반의 융기현상과 침하현상, 그리고 영구동토층의 온도상승을 초래할 수 있다. 열사이펀이란 구조체 내부에 충전된 냉매의 자가적인 열순환을 이용하여 지반의 온도를 영하상태로 제어하는 지반 안정화 공법 중 하나이다. 열사이펀은 대기중에 냉매의 열을 방출하는 응축부와 지중에 열을 흡수하는 증발부로 구성되어 있으며 대기의 온도가 영하의 상태일 때 지반의 온도를 영하상태로 제어한다. 본 연구에서는 열사이펀의 지반 열전달성능을 분석하기 위해 모형지반에 단열재를 배치하여 열사이펀을 통한 지반동결실험을 수행하였다. 단열재의 열차단성 및 열사이펀 길이를 고려하여 단열재 및 열사이펀의 성능실험을 수행하였으며, 실험에서 얻어진 물성치를 상용수치해석 프로그램인 TEMP/W에 반영하였다. 본 연구에서 제시된 실내실험과 수치해석 방법을 통해 열사이펀의 열성능을 산정할 수 있었다.

IPA기법을 활용한 기업의 사회공헌활동 비교 평가: 서비스업 및 제조업을 중심으로 (Comparative Assessment of Corporate Philanthropy by the IPA Method: Service and Manufacturing Industries)

  • 고정용;박현숙
    • 유통과학연구
    • /
    • 제13권4호
    • /
    • pp.89-98
    • /
    • 2015
  • Purpose - In today's globalized and modern business environment, corporate social responsibility (CSR) activities are considered to be essential for the sustainable development of enterprises. In addition, the corporate philanthropy that is related to CSR practices, as well as their being capable of reducing the anti-corporate sentiment of people have facilitated a qualitative forward leap into the quantitative growth phase. This study aims to undertake a comparative evaluation of corporate philanthropy through the Importance-Performance Analysis (IPA) method focusing on service and manufacturing industries, and to eventually determine a differentiated approach that is needed for corporate philanthropy. Research design, data, and methodology - The survey responses were collected through online research on specialized companies from consumers nationwide who were aged from 20 to 60 and who are aware of corporate philanthropy. A total of 408 sheets of questionnaire survey were used. Frequency analysis was undertaken in this study. The interviewees had demographic characteristics of gender: 206 males (50.5%) and 202 females (49.5%). They also had demographic characteristics of age: 82 people were over 20 (20.1%), 96 over 30 (23.5%), 105 over 40 (25.7%), and 125 over 50 (30.7%) years of age. The distribution of interviewees' residences is as follows: 154 persons (37.7%) in the Special City, 102 persons (25.0%) in the Metropolitan City, and 152 persons (37.3%) in the Provincial Region. The interviewees have been working for the following companies: 34 persons (8.3%) in LG Display, 80 (19.6%) in KT&G, 49 (12.0%) in Amore Pacific, 42 (10.3%) in KIA Motors, 47 (11.5%) in SBS, 52 (12.8%) in Shinhan Bank, 86 (21.1%) in Asiana Airlines, and 18 (4.4%) in Hyundai Department Store. We applied the paired t-test for the IPA analysis. PASW Statistics 18 was used for statistical analysis. Results - The results of IPA analysis indicated that the importance and performance degrees in both manufacturing and service industries were significantly different. Major empirical results showed that, in consumer, social, economic, philanthropic, and environmental dimensions, in the sub-factors of philanthropy activities in both manufacturing and service industries, the importance degree was found to be higher than performance degree. Further, the average difference between importance degree and performance degree by the sub-factors of philanthropy activities. On the other hand, the average difference of environmental dimension was found to be highest in both service and manufacturing industries. Thus, while consumers consider the philanthropy activities of the environmental dimension as most important, actual companies treat performance of philanthropy activities of the environmental dimension insufficiently or negligibly to some degree. Conclusions - The differentiated approach method that is required for corporate philanthropy may be proposed to uplift corporate accomplishments by analyzing the IPA of the attributes of the sub-factors of corporate philanthropy. This is, to an extent, insufficient in the existing studies related to the use of the IPA technique, and it shows the items that are to be conducted intensively.

Evaluation of seismic performance of mid-rise reinforced concrete frames subjected to far-field and near-field ground motions

  • Ansari, Mokhtar;Ansari, Masoud;Safiey, Amir
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.453-462
    • /
    • 2018
  • Damages to buildings affected by a near-fault strong ground motion are largely attributed to the vertical component of the earthquake resulting in column failures, which could lead to disproportionate building catastrophic collapse in a progressive fashion. Recently, considerable interests are awakening to study effects of earthquake vertical components on structural responses. In this study, detailed modeling and time-history analyses of a 12-story code-conforming reinforced concrete moment frame building carrying the gravity loads, and exposed to once only the horizontal component of, and second time simultaneously the horizontal and vertical components of an ensemble of far-field and near-field earthquakes are conducted. Structural responses inclusive of tension, compression and its fluctuations in columns, the ratio of shear demand to capacity in columns and peak mid-span moment demand in beams are compared with and without the presence of the vertical component of earthquake records. The influences of the existence of earthquake vertical component in both exterior and interior spans are separately studied. Thereafter, the correlation between the increase of demands induced by the vertical component of the earthquake and the ratio of a set of earthquake record characteristic parameters is investigated. It is shown that uplift initiation and the magnitude of tensile forces developed in corner columns are relatively more critical. Presence of vertical component of earthquake leads to a drop in minimum compressive force and initiation of tension in columns. The magnitude of this reduction in the most critical case is recorded on average 84% under near-fault ground motions. Besides, the presence of earthquake vertical components increases the shear capacity required in columns, which is at most 31%. In the best case, a direct correlation of 95% between the increase of the maximum compressive force and the ratio of vertical to horizontal 'effective peak acceleration (EPA)' is observed.

경골목구조에서 구조재와 오에스비로 구성된 못 접합부의 인발 및 전단성능 (Withdrawal and Lateral Resistance of Nail Joints Composed of Dimension Lumber and OSB in Light-Frame Wood Construction)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권3호
    • /
    • pp.211-220
    • /
    • 2013
  • 경골목조건축에서 못 접합부는 수평하중을 지지하고 전달하도록 설계되지만, 바람으로 인한 상향력처럼 인발하중에 직면하기도 한다. 본 연구에서는 경골목조건축에서 일반적으로 사용되는 구조재와 덮개로 구성된 못 접합부에 대하여 인발성능과 2면 전단시험을 통해 인발 및 측방하중에 대한 내력성능을 시험하고 설계기준에 부합되는 가를 평가하였다. 인발하중에 대한 내력성능은 부재의 비중에 의해 크게 좌우되었으며 I형장선의 경우 낮은 밀도에도 불구하고 높은 인발성능을 나타내었다. 최대 인발하중은 기준허용 최대 인발하중보다 매우 높게 나타났다. 전단성능도 비중이 큰 낙엽송과 오에스비로 구성된 접합부가 비중이 작은 SPF와 오에스비로 구성된 접합부보다 높은 성능을 나타내었으며 모두 기준설계치보다 높은 성능을 나타내었다. 접합부의 변형은 주로 못의 휨 변형에 의한 것으로 나타났으며 SPF와 오에스비로 구성된 접합부에서의 못의 휨 변형이 현저하게 나타났다.

Experimental study and FE analysis of tile roofs under simulated strong wind impact

  • Huang, Peng;Lin, Huatan;Hu, Feng;Gu, Ming
    • Wind and Structures
    • /
    • 제26권2호
    • /
    • pp.75-87
    • /
    • 2018
  • A large number of low-rise buildings experienced serious roof covering failures under strong wind while few suffered structural damage. Clay and concrete tiles are two main kinds of roof covering. For the tile roof system, few researches were carried out based on Finite Element (FE) analysis due to the difficulty in the simulation of the interface between the tiles and the roof sheathing (the bonding materials, foam or mortar). In this paper, the FE analysis of a single clay or concrete tile with foam-set or mortar-set were built with the interface simulated by the equivalent nonlinear springs based on the mechanical uplift and displacement tests, and they were expanded into the whole roof. A detailed wind tunnel test was carried out at Tongji University to acquire the wind loads on these two kinds of roof tiles, and then the test data were fed into the FE analysis. For the purpose of validation and calibration, the results of FE analysis were compared with the full-scale performance ofthe tile roofs under simulated strong wind impact through one-of-a-kind Wall of Wind (WoW) apparatus at Florida International University. The results are consistent with the WoW test that the roof of concrete tiles with mortar-set provided the highest resistance, and the material defects or improper construction practices are the key factors to induce the roof tiles' failure. Meanwhile, the staggered setting of concrete tiles would help develop an interlocking mechanism between the tiles and increase their resistance.

부력저항 영구앵커의 장기거동 특성에 관한 연구 (A Study on the Long-Term Behavior Characteristics of Buoyancy-Resistant Permanent Anchor)

  • 허병주;김찬기;정용건;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제11권12호
    • /
    • pp.27-35
    • /
    • 2010
  • 지하공간에 설치되는 구조물 중 지하수위 아래에 위치하는 부분은 상향으로 정수압인 부력이 작용하게 된다. 최근 큰 규모의 중요구조물 즉, 부력이 크게 발생하는 구조물은 공사비가 고가이나 안전율을 확실하게 증가시키는 방법인 부력저항 영구앵커를 많이 적용하고 있는 실정이다. 그러나, 부력저항 영구앵커의 저항 메커니즘 규명은 미흡한 실정이다. 특히, 시공 후 앵커의 장기거동에 대한 규명은 계측 관리의 어려움으로 이루어지지 않고 있는 것이 현실이다. 본 연구에서는 부력 저항 영구앵커의 설계 시 합리적인 구조물 거동 평가를 위하여 앵커두부에 하중계를 설치하여 앵커축력을 자동화계측 및 수동계측을 통해 시공초기부터 10년간 계측 분석하였으며, 이를 토대로 건물의 자중증가에 따른 앵커의 시공단계별 거동과 시간 경과에 따른 앵커의 장기거동(시공 후 10년 이내의 거동)을 분석하였다.

농업용 저수지 제방에서 토목섬유 블랭킷의 길이에 따른 감압정의 성능 평가 (Evaluation on the Performance of Relief Wells Using Geosynthetics Blanket Length as a Parameter in an Agricultural Reservoir Embankment)

  • 유전용;김승욱;장용채
    • 한국지반환경공학회 논문집
    • /
    • 제23권6호
    • /
    • pp.5-17
    • /
    • 2022
  • 저수지 제방의 침투제어를 목적으로 설치하는 감압정의 성능은 감압정의 직경, 간격, 관통율, 지반의 투수계수, 기초지반 지층의 두께 등 다양한 변수에 의해 영향을 받는다. 따라서 침투수압 경감을 목적으로 감압정을 채택하는 경우 이러한 매개변수를 충분히 검토하여 감압정의 설치제원을 결정해야 한다. 본 연구에서는 저수지 제방의 침투제어를 위한 대책공법으로 제방의 하류부에 감압정과 제방의 상·하류부에 토목섬유 블랭킷(이하 블랭킷)을 병행하여 설치하는 경우 블랭킷의 길이가 감압정의 성능에 미치는 영향을 평가하였다. 상·하류 블랭킷 길이-유량 관계에서 상류 블랭킷의 길이가 증가할수록 감압정에서 배출되는 유량은 감소하며, 하류 블랭킷의 길이가 증가할수록 감압정의 배출 유량은 증가하는 것으로 나타났다. 상·하류 블랭킷 길이-간격 관계에서 상류 블랭킷의 길이가 증가할수록 감압정의 간격은 증가하며, 하류 블랭킷의 길이가 증가할수록 감압정의 간격은 감소하는 것으로 나타났다. 따라서 블랭킷과 감압정을 병행하여 설치함으로써 댐제방의 침투안정성을 확보하고자 하는 경우 침투유량의 배출을 최소화하고 감압정의 간격 확대를 통한 경제성 확보를 위해서는 상류의 블랭킷 길이 증가가 하류의 블랭킷 길이 증가보다 더 효율적인 것으로 나타났다.

화강풍화토 지반에 설치된 압력재주입 그라우팅 보강재의 인발특성 (Pullout Characteristics of Pressure Reinjection-Grouted Reinforcements in Decomposed Granite Soil)

  • 심용진;이종규;이봉직
    • 한국지반환경공학회 논문집
    • /
    • 제13권11호
    • /
    • pp.61-68
    • /
    • 2012
  • 지반보강을 위해 국내에서 널리 사용되고 있는 공법으로 앵커공법, 소일네일 공법 및 소구경말뚝 공법 등을 들 수 있다. 상기 공법의 경우 보강재의 시공은 용도에 따라 구분되지만 공통적으로 보강재를 삽입한 후에 그라우팅 작업을 실시하는 공정이 포함되어 있다. 지금까지는 국내 대부분의 경우 중력식 그라우팅으로 시공되고 있지만 중력에 의해 그라우팅을 실시하기 때문에 천공 시 발생하는 지반이완영역에 대한 복원이 명확지 않아 보강재의 구조적 결함을 유발할 우려가 있다. 반면에 압력재주입 그라우팅은 먼저 그라우트를 채운 후 소정의 시간이 지나고 미리 설치한 튜브를 통하여 추가적으로 재주입하는 방식으로 기존의 그라우팅 방식에서 발생할 수 있는 문제를 상당부분 해결할 수 있어 그라우팅의 품질을 향상할 수 있다. 본 연구에서는 그라우팅 방식에 따른 인발특성을 평가하기 위하여 화강풍화토 지반을 대상으로 모형실험을 실시하였으며, 그라우팅방법에 따른 인발력 변화와 압력 재주입그라우팅의 재주입시기와 재주입압에 따른 보강재 지지력 증대 특성을 평가하고자 하였다. 연구결과 압력재주입식 그라우팅이 중력식그라우팅에 비해 최소 1.1배에서 1.3배까지 인발력이 크게 발휘되는 것을 확인하였으며, 압력재주입식 그라우팅의 적정 물시멘트비, 주입압력 및 재주입시기에 대한 고찰결과를 제시하였다.

장기계측을 통한 인장형 앵커의 인장력 손실 평가 (Evaluation of Loss of Prestress Force of Tensile Anchor by Long Term Measurement)

  • 이봉직;이종규
    • 한국지반환경공학회 논문집
    • /
    • 제16권10호
    • /
    • pp.15-22
    • /
    • 2015
  • 본 연구에서는 앵커의 장기 거동특성과 인장력 손실을 평가하기 위하여 실제 시공된 인장형 앵커를 대상으로 장기 계측을 실시하고 이를 기존 예측결과와 비교 분석하였다. 영구앵커는 비탈면 안정 혹은 구조물의 부상방지 등을 목적으로 사용되는 보강재로써 가설 앵커와 달리 구조물의 공용기간 동안 기능을 유지해야 한다. 그러나 시간 경과에 따라 앵커의 릴렉세이션 및 크리프가 지속적으로 발생되기 때문에 안정적인 기능발휘를 위해서는 인장력 손실에 대한 관리가 필수적이다. 지금까지 인장력 손실은 탄성론을 이용한 프리스트레스 감소와 인장재 종류에 따른 릴렉세이션을 값을 이용하여 산정하여 왔으며 장기적인 계측결과를 이용한 검증은 제한적인 실정이다. 이에 본 연구에서는 실제 시공된 인장형 앵커를 대상으로 현장조건과 상세 지반조사를 실시하였으며 하중계, 경사계 및 지하수위계를 설치하여 최대 500일 이상의 장기 계측결과를 분석하였다. 또한 측정된 벽체의 변위 및 앵커의 인장력 손실을 기존 해석결과와 비교함으로써 앵커의 장기 거동특성을 평가하였다. 평가결과 대부분의 앵커력 손실은 90일 이내에 발생되며, 앵커력 손실은 예측된 값보다 작게 측정되는 것으로 나타났다.