• 제목/요약/키워드: unscheduled error

검색결과 2건 처리시간 0.014초

GPS Anomaly Analysis and Pseudorange Accuracy Improvement by Anomalous Satellite Elimination

  • Yoo, Yun-Ja;Cho, Deuk-Jae;Park, Sang-Hyun
    • 한국항해항만학회지
    • /
    • 제34권7호
    • /
    • pp.511-516
    • /
    • 2010
  • GPS anomaly has increased according to the degradation of satellite performance, and many GPS users could be exposed to any kinds of error-included signals without any previous notice when unscheduled error occurred. RSIM (Reference Station Integrity Monitors) is a typical monitoring method to broadcast PRC (Pseudo Range Correction) for users. However, there were some cases that the receiver detected the anomalous satellite's signal even though it was unhealthy set, consequently it occurred a large range error. Then it is important to monitor the integrity of GPS signal and it is needed to devise the correction method of pseudorange by eliminating error-occurred PRN for notification to GPS users when it is monitored that the anomaly occurred. This paper proposes the basic concept of how to correct the pseudorange. The paper also shows the analysis results of PRN10 GPS anomaly occurred on day 39 in 2007 with corrected results by eliminating anomaly satellite (PRN10). The proposed correction method shows decreased pseudorange error range compared to the case when the anomaly satellite were used.

유동층 저회냉각기에서의 입자 혼합특성과 비유동 진단 (Characteristics of particle mixing and detection of poor fluidization in a fluidized bed ash cooler)

  • 김동원;이종민;김재성;김종진
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.231-237
    • /
    • 2005
  • Interruption of good fluidization in a fluidized bed ash cooler(FBAC) for discharging bed materials such as sand or coal ash particles from the CFB combustor is frequently happened because of agglomeration of the particles in the bed. This unstable operation may, in the worst case, result in an unscheduled boiler shut down. In this study, we examined the operation problems of the FBAC of Tonghae CFB boiler and studied and introduced the simple detection and solution techniques with analyzing the mixing property and the occurrence of defluidization in a simulated fluidized bed ash cooler system (0.5m-H x 0.5m-W x 1.0m-L). The bridge of the large particles at the bed surface could be observed, and this caused to form the defluidization area at the entrance of the FBAC. The defluidization was affected not only by airflow rates but also by the particles discharging rates as well as particle size distribution in the FBAC. The local defluidization could be detected by analysis of the accumulated standard deviation error at a given period of time. Also, the regulation of the overall or local airflow rate made clearing up the local defluidization possible.

  • PDF