• 제목/요약/키워드: unsaturated sandy soil

검색결과 23건 처리시간 0.019초

불포화 사질토의 도로함몰 특성에 관한 실험적 연구 (Experimental Study on Road-Subsidence Characteristics in Unsaturated Sandy Soils)

  • 권기철
    • 한국도로학회논문집
    • /
    • 제20권1호
    • /
    • pp.19-25
    • /
    • 2018
  • PURPOSES : The purpose of this study is to identify the road-subsidence mechanism in unsaturated sandy soils. METHODS : A series of soil chamber tests were conducted under various conditions. RESULTS : The cavity-expansion characteristics in unsaturated sandy soils due to seepage were affected by the outlet size, seepage intensity, relative density, and fine content. CONCLUSIONS : In unsaturated sandy soils, the cavity-expansion speed was affected by the outlet size, relative density, seepage intensity, and clay content; however, the cavity-expansion shape was very similar. As the outlet size and seepage intensity increased, the cavity-expansion speed increased. As the relative density increased, the cavity-expansion speed increased because of a sudden decrease in shear strength, resulting from the increased saturation (reduction of matric suction). The cavity expanded faster with the increasing clay content, up to a certain threshold. It expanded at a slower rate once it passed the threshold. Finally, it reached a stable state where the cavity did not expand due to seepage.

불포화 사질토의 전단특성 (The Shear Characteristics of Unsaturated Sandy Soils)

  • 임성윤
    • 한국지반공학회논문집
    • /
    • 제23권10호
    • /
    • pp.57-64
    • /
    • 2007
  • 현재 불포화토에 대한 많은 연구가 진행되어 왔고 최근 들어 많은 연구자들이 불포화지반의 안정성을 보다 합리적으로 판단하고 해석하기 위해 불포화상태를 고려한 연구의 필요성을 제기하여 왔다. 이를 위해서는 흡인력에 대한 전단강도의 증진효과를 정량화하고 이를 안정해석에 적용하는 것이 요구되고 있는 실정이다. 따라서 본 연구에서는 불포화 사질토의 전단강도 특성을 규명하기 일해서 국내에 널리 분포하는 화강풍화토 7가지를 대상으로 불포화 삼축압축시험을 수행하였으며, 결과치를 분석하여 강도특성을 규명하고자 한다.

Modeling the sensitivity of hydrogeological parameters associated with leaching of uranium transport in an unsaturated porous medium

  • Mohanadhas, Berlin;Govindarajan, Suresh Kumar
    • Environmental Engineering Research
    • /
    • 제23권4호
    • /
    • pp.462-473
    • /
    • 2018
  • The uranium ore residues from the legacies of past uranium mining and milling activities that resulted from the less stringent environmental standards along with the uranium residues from the existing nuclear power plants continue to be a cause of concern as the final uranium residues are not made safe from radiological and general safety point of view. The deposition of uranium in ponds increases the risk of groundwater getting contaminated as these residues essentially leach through the upper unsaturated geological formation. In this context, a numerical model has been developed in order to forecast the $^{238}U$ and its progenies concentration in an unsaturated soil. The developed numerical model is implemented in a hypothetical uranium tailing pond consisting of sandy soil and silty soil types. The numerical results show that the $^{238}U$ and its progenies are migrating up to the depth of 90 m and 800 m after 10 y in silty and sandy soil, respectively. Essentially, silt may reduce the risk of contamination in the groundwater for longer time span and at the deeper depths. In general, a coupled effect of sorption and hydro-geological parameters (soil type, moisture context and hydraulic conductivity) decides the resultant uranium transport in subsurface environment.

화강풍화토(SM soil)의 불포화 전단거동 분석 (Shear Strength-strain Behavior of Unsaturated Weathered Soil (SM))

  • 정상섬;이성철;정승화
    • 한국지반공학회논문집
    • /
    • 제38권2호
    • /
    • pp.5-13
    • /
    • 2022
  • 불포화토의 전단 특성 평가는 사면, 제방, 댐 등의 안정성과 투수 특성 평가에 매우 중요한 요소이다. 본 연구에서는 화강풍화토의 불포화 전단특성을 파악하기 위하여 불포화 삼축실험을 수행하였다. 실험에 사용된 시료는 국내에 분포하는 세립분이 다량함유된 SM계열 화강 풍화토이며, 다짐을 통하여 재성형 하였다. 모관 흡수력 및 시료의 밀도에 따른 불포화 전단 특성을 분석하였으며, 전단 과정에서 일정한 모관 흡수력을 유지 하기 위해 압밀-배수삼축실험(CD-test)을 수행하였다. 본 연구결과 화강풍화토 시료의 겉보기마찰각(ϕb)과 AEV(Air Entry Value)는 상대밀도가 증가함에 따라 증가하는 경향을 나타내었다. 그러나 모관흡수력이 증가함에 따라서는 점착력(c) 역시 증가하였지만 내부마찰각(ϕ')은 크게 변함이 없는 것으로 확인 되었다.

불포화 사질토양을 이용한 도시하수의 3차 처리 (Tertiary Treatment of Municipal Wastewater Using Unsaturated Sandy Soil)

  • 김승현;정종배;하현수
    • 한국환경농학회지
    • /
    • 제22권2호
    • /
    • pp.111-117
    • /
    • 2003
  • 모래층 토양이 도시하수의 3차 처리에 이용될 경우 COD 제거율은 적용유량에 관계없이 약 70%에 이르는 것을 알 수 있었다. 적용유량이 증가함에 따라 COD제거에 필요한 토양 층의 깊이가 증가하여 50 L/day의 유량에서는 약 60 cm에 달하는 것을 알 수 있었다. 질산화는 매우 빨라서 표층토양 $10{\sim}20\;cm$에서 반응이 거의 완료됨을 알 수 있었다. 총 질소의 제거율은 유량에 상관없이 약 20%로 낮은 편이었으며, 이에 대한 보완책이나 추가적인 연구가 필요한 것으로 판단된다. 잔디를 식재할 경우 오염물의 처리효율에는 영향이 거의 없으나 투수능 유지에는 도움이 되는 것을 알 수 있었으며, 토양에 함유된 유기물로부터 상당한 양의 오염물이 용출되는 것을 알 수 있었다. 탈질과정에서는 아산화질소도 발생하므로 본 연구의 결과를 현장에 적용하기 전에 이에 대한 추가적인 연구도 필요할 것으로 판단된다.

생활폐기물 매립장내 토양가스 분포와 지하수수질 특성

  • 고경석;조춘희;김통권;김탁현
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.377-380
    • /
    • 2004
  • To identify the effect of landfill waste for groundwater and unsaturated air environment, soil gas survey and hydrogeochemical study were executed. The geology of the study area is granite and aquifer is mainly composed of sandy soil. The results of spatial distribution from soil gas showed the boundary of buried waste and processes and degree of waste decomposition. Groundwater contamination by leachate from landfill is controlled by groundwater flow attributed by the original topography and liner.

  • PDF

유류오염대수층에서 고온 공기분사공정법을 통한 TPH, VOCs, $CO_2$ 변화에 관한 특성인자 연구

  • 이준호;박갑성
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2005년도 총회 및 춘계학술발표회
    • /
    • pp.232-236
    • /
    • 2005
  • In-situ Air Sparging (IAS, AS) is a groundwater remediation technique, in which organic contaminants are volatilized into air as it rises from saturated to vadose soil zone. The purpose of this study was to investigate the effect of environmental conditions on the degradation of VOCs (Volatile Organic Compounds) and $CO_2$ in the unsaturated zone and TPH (Total Petroleum Hydrocarbons) in saturated zone of sandy loam. In the laboratory, diesel (10,000 mg TPH/kg)-contaminated saturated soil. After heating the soil for 36 days, the equilibrium temperature of soil reached to $34.9{\pm}2.7^{\circ}C$ and TPH concentration was reduced to 78.9% of the initial value, Volatilization loss of VOCs in TPH was about 2%, The reduction gradient of $CO_2$ concentration was 0.018/day in air space and 0.0007/day in unsaturated zone.

  • PDF

Factors affecting hydraulic anisotropy of soil

  • Nurly Gofar;Alfrendo Satyanaga;Gerarldo D. Aventian;Gulnur Pernebekova;Zhanat Argimbayeva;Sung-Woo Moon;Jong Kim
    • Geomechanics and Engineering
    • /
    • 제36권4호
    • /
    • pp.343-353
    • /
    • 2024
  • The hydraulic anisotropic behavior of unsaturated soil has not been fully explored in relation to the grain-size distribution. The present study conducted laboratory assessments to examine the hydraulic anisotropy condition of statically compacted specimens in various initial states. The investigation incorporated the concept of hydraulic anisotropy by employing two discrete forms of soil stratification: horizontal-layering (HL) and vertical-layering (VL). The examined soils comprised sandy silt and silty sand, exhibiting either unimodal or bimodal soil-water characteristic curve (SWCC). This study aimed to investigate the potential correlation between the hydraulic anisotropy ratio and soil properties. The present study established a correlation between the hydraulic anisotropy ratio and several soil parameters, including fine content, dry density, plastic limit, and liquid limit. The study results indicate a non-linear relationship between the percentage of fine and dry density in soils with unimodal and bimodal soil-water characteristic curve (SWCC) and hydraulic anisotropy ratio.

사질토의 함수특성곡선에 대한 균등계수와 공극율의 영향에 관한 연구 (A Study on the Effects of the Coefficient of Uniformity and Porosity on the Soil-Water Characteristic Curves of Sandy Soils)

  • 유건선
    • 한국지반환경공학회 논문집
    • /
    • 제14권5호
    • /
    • pp.41-47
    • /
    • 2013
  • 일반적으로 입도분포가 양호하며 조밀한 흙은 공학적 성질이 우수하다. 불포화토의 공학적 성질, 즉 전단강도, 압축성, 투수성 등의 거동은 흙의 함수특성곡선과 밀접한 관계가 있다. 따라서 사질토의 입도분포 및 다짐상태와 관련있는 균등계수와 공극율이 그 흙의 함수특성곡선에 미치는 영향을 연구하는 것은 중요하다. 본 연구에서는 6개의 사질토 시료에 대하여 템페셀을 사용하여 함수특성곡선시험을 하였다. 시험결과를 Fredlund and Xing 모델식으로 최적화하여 모델식의 매개변수를 구하였고, 시료의 균등계수와 공극율이 매개변수에 미치는 영향을 조사하였다. 시료의 잔류흡수력은 시료의 공극율이 작을수록, 그리고 균등계수가 클수록 증가하였으며, 함수특성곡선의 최대경사는 시료의 균등계수와 상관없이 공극율이 작을수록 완만해짐을 알 수 있었다.

Pressure-Plate Extractor 내(內) 토양수분함량(土壤水分含量) 변화(變化)로부터 불포화수리전도도(不飽和水理傳導度)의 계산(計算) (Calculation of Unsaturated Hydraulic Conductivity from Soil Moisture Changes in Pressure-Plate Extractor)

  • 노희명;유순호
    • 한국토양비료학회지
    • /
    • 제17권1호
    • /
    • pp.7-11
    • /
    • 1984
  • 토양(土壤)의 불포화수리전도도(不飽和水理傳導度)와 수분특성곡선(水分待性曲線)을 동시(同時)에 구(求)할 수 있는 방법(方法)을 제안(提案)하기 위하여 Gardner의 유출양법(流出量法)을 변형(變形)하여 soil moisture pressure-plate extractor를 이용(利用)하여 공시토지(供試土壤)에 대(對)하여 실험(實驗)을 수행(遂行)하였다. Cardner의 pressure-plate 유출방정식(流出方程式)을 이용(利用)하여 상이(相異)한 수분장력(水分張力)에서 pressure-plate extractor내(內) 수분함량변화(水分含量變化)로부터 불포화수리전도도(不飽和水理傳導度)를 계산(計算)하였다. 수분장력(水分張力) 30mbar에서 10bar까지 본량(本良) 사양토(砂壤土), 예산(禮山) 미사질양토(微砂質壤土) 및 포곡(浦谷) 식양토(埴壤土)의 불포화수리전도도(不飽和水理傳導度)는 각각(各各) $3.09{\times}10^{-2}cm/day{\sim}4.06{\times}10^{-6}cm/day$, $1.34{\times}10^{-2}cm/day{\sim}7.30{\times}10^{-6}cm/day$$1.83{\times}10^{-2}cm/day{\sim}8.50{\times}10^{-6}cm/day$로 변(變)하였다. 유출양법(流出量法)과 비교(比較)하여 적당(摘當)한 시간(時間) 간격(間隔)으로 수분정량(水分定量)을 하여야 하고 그때마다 압력(壓力)을 조정(調整)하여야 하는 불편(不便)이 있으나, 동시(同時)에 여러 토양(土壤)의 불포화수리전도도(不飽和水理傳導度)의 계산(計算)이 가능(可能)한 장점(長點)이 있었다. soil moisture pressure-plate extractor내(內) 토양수분함량변화(土壤水分含量變化)로부터 불포화수리전도도(不飽和水理傳導度)의 계산(計算)이 가능(可能)하였다.

  • PDF