• Title/Summary/Keyword: unsaturated permeability coefficient

Search Result 35, Processing Time 0.023 seconds

A Fundamental Study on the Properties of Permeable Polymer Concrete (투수성 폴리머 콘크리트의 성질에 관한 기초적 연구)

  • 박응모;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.363-368
    • /
    • 1997
  • In this study, permeable polymer concretes using unsaturated polyester (UP) resin with binder contents of 6, 7 and 8%, filler-binder ratios of 0, 0.5, 1.0%, and various sand and aggregate contents are prepared, and tested for compressive and flexural strengths, length change and water permeability. The effects of the mix proportioning factors on the strength properties, length change and coefficient of permeability of the permeable polymer concrete are discussed. From the test results, increase in the compressive strength and decrease in the coefficient of permeability of permeable polymer concrete are clearly observed with increasing filler-binder ratio. The permeable polymer concretes having a compressive strength of 9.4~28.3MPa and a coefficient of permeability of 0.12~1.93 cm/s can be produced in the consideration of the mix proportioning factors.

  • PDF

Determination of Soil Water Characteristic Curve and Permeability Equation of Unsaturated Soils Using Modified Triaxial Apparatus (변형된 삼축시험장치를 이용한 불포화토의 함수특성곡선과 투수계수방정식의 결정)

  • Kim Suk-Nam;Park Chi-Won;Mok Young-Jin;Kim Suk-Myung
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.59-64
    • /
    • 2005
  • In studying unsaturated soil mechanics, determination of soil water characteristic curve and permeability equation though not easy, is an essential factor. In this research a new testing apparatus was developed to determine soil water characteristic curve and permeability equation. A test to get saturated permeability coefficients and soil water characteristic curves for two soils was performed by using the developed testing apparatus. First, a saturated permeability test was performed and then the test to get soil water characteristic curve of a drying process was performed. Next, the test to get soil water characteristic curve of a wetting process was performed. Test results showed hysteresis phenomena between soil water characteristic curve of a drying process and soil water characteristic curve of a wetting process. The permeability equations were determined by a theoretical method where a saturated permeability coefficient and a soil water characteristic curve were used.

Fractal Scaling of Permeability in Unsaturated Fractured Tuff: Wavelet-Based Approach

  • Hyun, Yunjung
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.140-143
    • /
    • 2003
  • Air permeabilities in unsaturated fractured tuff at the Apache Leap Research Site (ALRS) near Superior, Arizona, exhibit a self-affine behavior, thus renders a field random fractal. Based up fractal scaling, the observed scale effect has been interpreted [Hyun et al., 2002]. Recently, Frantziskonis and Hansen [2000] presented that fractal scaling can be represented based on wavelets. This study deals with the way of using wavelets for fractal scaling. A numerical study is presented to examine the applicability of wavelet-based approach to determining upscaled air permeability values on various data supports at the site. To characterize the scaling property of self-affine fields generated based upon wavelets, Hurst coefficient, H. was inferred by applying the average wavelet coefficient (AWC) method. The result yielded H = 0.24, which is very close to the result of geostatistical analysis using a power variogram (H = 0.22). The study concludes that wavelet-based scaling is a useful way of determining parameter values on different data supports, which is an essential task for modeling of subsurface flow and mass transport in a numeric grid with different resolutions (grid size).

  • PDF

Chloride-Penetration Analysis in Cracked Early-Age Concrete (균열을 갖는 초기재령 콘크리트의 염화물 침투 해석)

  • 송하원;박상순;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.635-640
    • /
    • 2001
  • In this study, a mathematical model is established for prediction of chloride penetration in unsaturated cracked early-age concrete. The model is combined with models for thermo-hygro dynamic coupling of cement hydration, moisture transport and micro-structure development. Chloride permeability and water permeability at cracked early-age concrete specimens are evaluated using a rapid chloride permeability test and a low-pressure water permeability test, respectively. Then, a homogenization technique is introduced into the model to determine equivalent diffusion coefficient and equivalent Permeation coefficient. Increased chloride transport due to cracks at the specimen could be predicted fairly well by characterizing the cracks using proposed model. Proposed model is verified by comparing diffusion analysis results with test results.

  • PDF

Engineering Properties of Permeable Polymer Concrete for Pavement using Powdered Waste Glass and Recycled Coarse Aggregate (폐유리분말과 재생골재를 사용한 포장용 투수성 폴리머 콘크리트의 공학적 성질)

  • Sung, Chan-Yong;Kim, Tae-Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.59-65
    • /
    • 2011
  • This study was performed to evaluate the compressive and flexural strength, void ratio and permeability coefficient used powdered waste glass, $CaCO_3$, recycled coarse aggregate and unsaturated polyester resin to find optimum mix design of permeable polymer concrete for pavement. The compressive and flexural strength of permeable polymer concrete for pavement using powdered waste glass were in the range of 16.8~19.7 MPa and 4.7~6.1 MPa, respectively. it was satisfied the regulation of permeable concrete for pavement (18 MPa and 4.5 MPa). The void ratio and permeability coefficient were decreased with increasing the powdered waste glass, respectively. The void ratio and permeability coefficient were satisfied national regulation of permeable concrete for pavement (8 % and $1{\times}10^{-2}$ cm/s). In addition, this study found out that required amount of binder was decreased with increasing the powdered waste glass. This fact is expected to have economical effects during the use of powdered waste glass in the manufacture of permeable polymer concrete for pavement. Accodingly, the powdered waste glass can be used for permeable concrete material.

Physical Properties of Permeable Polymer Concrete (투수성 폴리머 콘크리트의 물리적 성질)

  • 최재진;황의환
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.41-48
    • /
    • 2002
  • In this paper, permeable polymer concretes with unsaturated polyester or vinylester resin content from 5 to 8 weight %, resin-filler ratio of 1 : 1, sand content from 0 to 15 weight % and crushed stone of size 2.5∼10 mm were prepared, and tested for compressive strength, flexural strength and water permeability. The effects of the resin and sand contents on the properties of permeable polymer concrete were discussed. It is concluded from the test results that increase in the strength and decrease in the coefficient of permeability of the permeable polymer concrete arc clearly observed with increasing the resin and sand contents. The permeable polymer concrete showed compressive strength in the range of 170 to 350 kgf/$\textrm{cm}^2$ and flexural strength in the range of 40 to 90 kgf/$\textrm{cm}^2$ at coefficient of permeability from 0.1 to 1.0 cm/sec in this experiment.

An Experimental Study on the Engineering Characteristics Analysis of Unsaturated Weathered Granite Soil (불포화된 화강풍화토에 대한 공학적 특성분석을 위한 실험적 연구)

  • Kim, Joon-Seok
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.577-585
    • /
    • 2020
  • Purpose: The presence of the matric suction in unsaturated soil increases the stability of the slope, but the reduction of the matric suction due to precipitation can cause sudden slope failure, resulting in a major disaster. In this paper, engineering characteristics in unsaturated state were analyzed for granite weathering soil, which is the representative mountain soil of Korea. Method: Experiments and analysis were conducted on granulated weathering soil as unsaturated shear strength relationships for moisture characteristic curves, unsaturated injection curves, and matric suction under unsaturated conditions. Result: It was analyzed that a rapid change in the matric suction for volumetric water content occurs compared to the case where the particle size distribution is poor and the particle size distribution is good. A good case for the particle size distribution indicates a relatively small permeability coefficient at the same matric suction capacity compared to a poor case. The greater thematric suction, the greater the shear strength. Conclusion: For Korea's representative soil, granulated weathering soil, the functional characteristic curves, unsaturated permeability coefficients, unsaturated shear strength, etc., which are engineering characteristics in unsaturated state, were tested to secure each correlation.

Soil-Water Characteristics and Hysteretic Behaviors on Unsaturated Pavement Subgrades in Test Roads (시험도로 노상토의 불포화 함수특성 및 이력현상)

  • Park Seong-Wan;Shin Gil-Ho;Kim Byeong-Soo
    • International Journal of Highway Engineering
    • /
    • v.8 no.2 s.28
    • /
    • pp.95-104
    • /
    • 2006
  • Hysteresis is a common feature exhibited in hydraulic properties of an unsaturated soil. This study focuses on hysteresis observed in a compacted weathered granite subgrade soils based on the pressure plate laboratory tests. It was found that the Soil-Water Characteristics Curve of a soil is hysteretic and unique. The results also show that the wetting and drying curves predicted using the Fredlund and Xing model is quite close to the laboratory-measured results. For a specific matric suction, water content or coefficient of permeability on a wetting curve is always lower than those found on a drying curve.

  • PDF

Engineering properties of permeable polymer concrete for pavement using powdered waste glass as filler (폐유리분말을 충전재로 사용한 포장용 투수성 폴리머 콘크리트의 공학적 성질)

  • Sung, Chan-Yong;Kim, Tae-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.145-151
    • /
    • 2011
  • This study was performed to evaluate the void ratio, compressive and flexural strength, and permeability coefficient used powdered waste glass, $CaCO_3$, recycled coarse aggregate and unsaturated polyester resin to find optimum mix design of permeable polymer concrete for pavement. The void ratio and permeability coefficient of permeable concrete for pavement was decreased with increasing the powdered waste glass, respectively. The compressive strength and flexural strength was increased with increasing the powdered waste glass, respectively. In addition, this study found out that required amount of binder was decreased with increasing the powdered waste glass. This fact is expected to have economical effects during the use of powdered waste glass in the manufacture of permeable polymer concrete for pavement. Therefore, powdered waste glass and recycled coarse aggregate can be used for permeable polymer pavement.

Engineering Properties of Permeable Polymer Concrete for Pavement Using Polypropylene Fiber (폴리프로필렌섬유를 혼입한 포장용 투수성 폴리머 콘크리트의 공학적 성질)

  • Sung, Chan-Yong;Lee, Seung-Hoon
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.2
    • /
    • pp.277-283
    • /
    • 2010
  • Research on permeable pavement like asphalt and concrete pavement with porous structure has been increasing due to environmental and functional need such as reduction of run off and flood. This study was performed to evaluate void ratio, permeability coefficient, and compressive strength of permeable polymer concrete (PPC) using crushed and recycled coarse aggregate that is obtained from waste concrete. Also, 6 mm length of polypropylene fiber was used to increase toughness and interlocking between aggregate and aggregate surrounded by binder. Binder and filler used were unsaturated polyester resin and CaCO3, respectively. The mix proportions were determined to satisfy the requirement for the workability and slump according to aggregate sizes 5~10 mm. In the test results, regardless of kinds of aggregates and fiber contents, the void ratio, permeability coefficient and compressive strength of all types of PPC showed the higher than the criterion of porous concrete that is used in permeable pavement in Korea. Also, strengths of PPC with increase polypropylene fiber volume fraction showed slightly increased tendency due to increase binder with increase of fiber volume fraction. Accordingly, polypropylene fiber and recycled coarse aggregate can be used for permeable pavement.