• Title/Summary/Keyword: unloading performance

Search Result 133, Processing Time 0.026 seconds

Design and Analysis of Disk Bump to Improve the Unloading Performance in HDD (HDD 의 언로딩 성능 개선을 위한 디스크 범프의 설계 및 해석)

  • Lee, Yong-Eun;Lee, Yong-Hyun;Lee, Hyung-Jun;Park, No-Cheol;Park, Kyoung-Su;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.4
    • /
    • pp.183-190
    • /
    • 2007
  • In most hard disk drives that apply the ramp load/unload technology, the head is unloaded at the outer edge of the disk while the disk is rotating. During the unloading process, slider-disk contacts may occur by lift-off force and rebound of the slider. The main issue of this paper is to prevent the slider-disk contact by rebound, and we apply a disk bump to the unloading process. To do so, first, the ranges of bump dimension are determined. Second, the stability of each bump is checked by dynamic simulation. Finally, unload simulations are performed for stable bump designs. As a result of these steps, the effect of the bump design and the position for the unloading performance were investigated. As a consequence, we propose the optimal bump design to improve the unloading performance. Furthermore, we can identify to remove rebound contact by applying a bump on disk during the unloading process.

  • PDF

Optimal Dimple Point of SFF HDD Suspension for Improving the Unloading Performance (언로드 성능 향상을 위한 딤플 포인트의 최적설계)

  • Kim, Ki-Hoon;Lee, Young-Hyun;Lee, Hyung-Jun;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.609-612
    • /
    • 2007
  • The HDD (hard disk drive) using Load/Unload (L/UL) technology includes the benefits which are increased areal density, reduced power consumption and improved shock resistance than those of contact-start-stop (CSS). Dynamic L/UL has been widely used in portable hard disk drive and will become the key technology for developing the small form factor hard disk drive. The main design objectives of the L/UL mechanisms are no slider-disk contact or no media damage even with contact during L/UL, and a smooth and short unloading process. In this paper, we focus on lift-off force, pitch static attitude (PSA), roll static attitude (RSA) and dimple point. The "lift-off" force, defined as the minimum air bearing force, is another very important indicator of unloading performance. A large amplitude of lift-off force increases the ramp force, the unloading time, the slider oscillation and contact-possibility. PSA and RSA are also very important parameters in L/UL system and stability of slider is mainly determined by PSA and RSA. Dimple point by PSA and RSA is also important indicator. Therefore we find the optimal dimple point of SFF HDD suspension for improving the unloading performance.

  • PDF

Development and Application of a Loading/Unloading Device for Effective Material Handling (효율적 인력물자 운반용 적.하화대의 개발 및 활용)

  • 황춘수;장통일;임현교
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.125-131
    • /
    • 2003
  • In recent years, the Korean Army made use of fork-lifters or conveyors when loading and/or unloading military material in order to prevent accidents and to promote efficiency of military material handling activities. However, in troops smaller thin battalions, manual material handling activities are still committed for many reasons. In this thesis, a brand new loading/unloading device for efficient military material handling or manual workers was developed, and its validation study was conducted through objective assessment based on electromyography, subjective assessment based on Body-Map technique developed by Corlett and Bishop, and finally work performance comparison. The results of EMG analysis showed that muscular workload improved by 24% when using the device compared to manual work without the device, and complain of each body part was remarkably reduced. In addition, remarkable effectiveness enhancement was observed in the work performance. Consequently, it could be concluded that ergonomic devices like one developed in this research should be studied further in the ergonomic sense as well as in the economical sense.

Development of Automation System for Press Line (대형 프레스용 자동화 시스템 개발)

  • 김순철;권용수;한상동;노태정;안병규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.806-809
    • /
    • 1996
  • The present development relates to an apparatus for loading or unloading a workpiece, and more particularly, to an apparatus for loading or unloading a workpiece from a press die or supplier An apparatus for loading or unloading a workpiece has been installed in a press in order to load or unload a workpiece from a press die. There has been known such a loading or unloading apparatus as the apparatus can feed a workpiece in not only the horizontal direction but also in the vortical direction. Press working system in automotive factories are now switching over to a transfer press work ing system. The current problem to be sieved immediately is to automate the existing manual press lines for the manpower saving and speedy production. “Automation system for press line”has just been developed to meet the above trend. The loader and unloader are development under the design concept for high performance, easy control and operational safety to meet the more extensive.

  • PDF

Experimental Study on Various Ramp Profiles during Unloading Process (초소형 HDD의 언로딩 과정에서 램프 형상에 대한 실험 연구)

  • Lee, Young-Hyun;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.314-317
    • /
    • 2005
  • There are many benefits such as increased areal density, reduced power consumption, applied smaller size and improved shock resistance in Load/Unload(L/UL) mechanism. It has been the key technology of developing small form factor hard disk drive used in portable digital devices. The main objectives of L/UL are no slider-disk contact and faster L/UL process. For realizing those, we must consider many design parameters in L/UL systems. In this paper, we focus on the effects of ramp profile. We can investigate dynamic characteristics of suspension tap and slider on ramp during unloading process experimentally. In special, we examine the effects of vortical velocities, ramp slopes and disk vibrations. As the result of these experiments, we propose design criteria of advanced ramp profile for good unloading performance.

  • PDF

A new reconfigurable liquid-metal-antenna-based sensor

  • Zhou, Xiaoping;Fu, Yihui;Zhu, Hantao;Yu, Zihao;Wang, Shanyong
    • Smart Structures and Systems
    • /
    • v.30 no.4
    • /
    • pp.353-369
    • /
    • 2022
  • In this paper, a new sensor chip with frequency reconstruction range of 2.252 GHz ~ 2.450 GHz is designed and fabricated. On this basis, a self-designed "T-shaped" shell is added to overcome the disadvantage of uneven deformation of the traditional steel shell, and the range of the sensor chip is expanded to 0 kN ~ 96 kN. The liquid metal antenna is used to carry out a step-by-step loading test, and the relationship between the antenna resonance frequency and the pressure load is analyzed. The results show that there is a good linear relationship between the pressure load and the resonant frequency. Therefore, the liquid metal antenna can be regarded as a pressure sensor. The cyclic loading and unloading experiments of the sensor are carried out, and different loading rates are used to explore the influence on the performance of the sensor. The loading and unloading characteristic curves and the influence characteristic curves of loading rate are plotted. The experimental results show that the sensor has no residual deformation during the cycle of loading and unloading. Moreover, the influence of temperature on the performance of the sensor is studied, and the temperature correction formula is derived.

A Experimental Study on the Fire Resistant Performance of the High Strength Concrete with Loading and Unloading test (재하 및 비재하 내화 실험을 통한 고강도콘크리트의 내화성능에 관한 실험적 연구)

  • Kim, Woo-Jae;Kim, Hyun-Bae;Kim, Kyu-Yong;Kim, Young-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.61-64
    • /
    • 2009
  • Recently, the higher buildings are, the stronger concrete are used. Ultra high strength concrete have the possibility of spalling when a fire breaks out. so the fire-resistance performance is necessary to use the ultra high strength concrete on the high-rise building. On this study, the heating test for the concrete with loading/unloading is performed for ultra high strength concrete using nylon fiber. The heating test followed by ISO-834 heating curve on the real-size specimen and the strength of concrete are 60, 80, 100, 200 MPa.

  • PDF

Estimation of Curving Performance and Running Safety of Gwangju Electric Multiple Unit for City Subway (광주도시철도 전동차의 곡선추종성 및 주행안전성 평가)

  • Ham, Young-Sam;Oh, Taek-Yul
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.745-750
    • /
    • 2004
  • For the safety of railway, it should be evaluated for the running safety by measuring the derailment coefficient. Although railway has run the fixed and maintained rail, some of railway is derailed. This report shows the results that performed the static load test, wheelset manufacturing for test, main line running test on the basis of the derailment theory and experience. It is executed main line test into more than 80km/h for estimating the curving performance and running safety of Gwangju EMU. As the test results, could confirm the curving performance and running safety of Gwangju EMU from the results of the wheel unloading, lateral force, derailment coefficient etc. Derailment coefficient was less than 0.8, and lateral force allowance limit and wheel load reduction ratio were enough safe.

  • PDF

Evaluating the Performance of Freight Railway Stations Using Data Envelopment Analysis (자료포락분석을 활용한 철도화물취급역의 성과평가)

  • Kim, Seong-Ho;Oh, Suk-Moon
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.2
    • /
    • pp.315-320
    • /
    • 2009
  • In this paper we presents an approach to evaluating the performance of freight railway stations based on several performance indicators as an alternative to the evaluation based on single indicator. Such evaluation needs a way to weight the importance of the individual performance indicator. Data envelopment analysis (DEA) suggested by Charnes, Cooper, and Rhodes (1978) can be used to determine the weights. Using DEA we evaluate 353 freight railway stations based on four performance indicators: loading volume, unloading volume, loading revenue, unloading revenue. The evaluation results facilitates the organization's decision making by providing valuable information.

Evaluation of Curving Performance and Running Safety of New High-Power Electric Locomotive (신형 고출력 전기기관차의 곡선추종성 및 주행안전성 평가)

  • Ham, Young Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.6
    • /
    • pp.827-832
    • /
    • 2013
  • In this study, curve responsiveness was assessed based on the lateral force and running safety was evaluated based on the wheel unloading ratio and derailment coefficient, which is the ratio of the wheel load and the lateral force. The evaluation of the curving performance and running safety of the new high-power electric locomotive showed that the derailment coefficient appeared higher when the wheel-set was set to the front of the train instead of being placed backward, and the maximum value of the derailment coefficient was recorded as 0.572 on the Gyeongbu line. Furthermore, the lateral force increased in curved sections, and it appeared to be proportional to the curve radius. Meanwhile, a maximum axis lateral force of 77.6 kN was recorded on the Taebaek line, and the wheel unloading ratio was 47.6% on the Yeongdong line. Finally, the running safety at the maximum speed as well as the through-curve performance of the curve radius satisfied the required standards.