• Title/Summary/Keyword: university lab safety

Search Result 312, Processing Time 0.022 seconds

Status and Prospect of Lactic Acid Bacteria with Antibiotic Resistance (항생제 내성을 가진 유산균의 현황과 전망)

  • Chon, Jung-Whan;Seo, Kun-Ho;Bae, Dongryeoul;Jeong, Dongkwan;Song, Kwang-Young
    • Journal of Dairy Science and Biotechnology
    • /
    • v.38 no.2
    • /
    • pp.70-88
    • /
    • 2020
  • Lactic acid bacteria (LAB) form an essential part of the intestinal microbiota of the human body and possess the ability to stabilize the intestinal microbiota, strengthen immunity, and promote digestion as well as intestinal synthesis of vitamins, amino acids, and proteins. Hence, LAB are currently widely used in various products. However, due to the indiscriminate overuse of antibiotics in humans and livestock, bacterial resistance to antibiotics has been increasing rapidly, which has led to serious problems in the treatment of bacterial infections. Additionally, several reports have revealed that antibiotic-resistant LAB may infect people whose immune systems are not fully developed or whose immune systems are temporarily weakened. Therefore, it is imperative to consider the possibility of antibiotic-resistant LAB causing diseases in humans and animals, investigate the mechanism of action between antibiotics and LAB, and determine the relevant regulations for the safe use of LAB.

Realization of Real-time Scheduler for Nuclear Safety System (원자력 안전계통의 실시간 스케쥴러 구현)

  • Park, Dong-Chul;Kim, Tae-Yeon;Lyou, Joon
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.215-216
    • /
    • 2007
  • This paper presents a real-time scheduler for nuclear safety system. According to constraints and requirements of nuclear safety system, scheduler design analysis is done and algorithms are developed for implementation. Using DSP based hardware, a real-time scheduler is realized. Consequently, this paper shows the performance of periodical software through the monitoring program.

  • PDF

Output Voltage Ripple Analysis and Design Considerations of Intrinsic Safety Flyback Converter Based on Energy Transmission Modes

  • Hu, Wei;Zhang, Fangying;Xu, Yawu;Chen, Xinbing
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.908-917
    • /
    • 2014
  • For the purpose of designing an intrinsic safety Flyback converter with minimal output voltage ripple based on a specified output current, this paper first classified the energy transmission modes of the system into three sorts, namely, the Complete Inductor Supply Mode-CCM (CISM-CCM), the Incomplete Inductor Supply Mode-CCM (IISM-CCM) and the Incomplete Inductor Supply Mode-DCM (IISM-DCM). Then, the critical secondary self-inductance assorting the three modes are deduced and expressions of the output voltage ripples (OVR) are presented. For a Flyback converter with constant loads and switching frequency, it is shown that the output voltage ripple in the CISM-CCM is the smallest and that it has no relationship with the secondary self-inductance. Otherwise, the OVR of the other two modes are bigger than the previously mentioned one. It is concluded that the critical inductance between the CISM-CCM and the IISM-CCM is the minimal secondary self-inductance to ensure the smallest output voltage ripple. At last, a design method to guarantee the minimum OVR within the scales of the input voltage and load are analyzed, and the minimum secondary self-inductance is proposed to minimize the OVR. Simulations and experiments are given to verify the results.

Searching for critical failure surface in slope stability analysis by using hybrid genetic algorithm

  • Li, Shouju;Shangguan, Zichang;Duan, Hongxia;Liu, Yingxi;Luan, Maotian
    • Geomechanics and Engineering
    • /
    • v.1 no.1
    • /
    • pp.85-96
    • /
    • 2009
  • The radius and coordinate of sliding circle are taken as searching variables in slope stability analysis. Genetic algorithm is applied for searching for critical factor of safety. In order to search for critical factor of safety in slope stability analysis efficiently and in a robust manner, some improvements for simple genetic algorithm are proposed. Taking the advantages of efficiency of neighbor-search of the simulated annealing and the robustness of genetic algorithm, a hybrid optimization method is presented. The numerical computation shows that the procedure can determine the minimal factor of safety and be applied to slopes with any geometry, layering, pore pressure and external load distribution. The comparisons demonstrate that the genetic algorithm provides a same solution when compared with elasto-plastic finite element program.

A Study on Safe School Zone System using LabVIEW

  • Kim, Kyung-Hwa;Shim, Joon-Hwan
    • Journal of Engineering Education Research
    • /
    • v.13 no.5
    • /
    • pp.20-24
    • /
    • 2010
  • The total number of deaths by traffic accidents is decreasing every year in our country. However, in 2009, children died in traffic accidents at a rate of 2.3 deaths per 100,000 children, which was higher than the average of OECD countries (1.9 deaths per 100,000 children). In particular, traffic accidents are showing rapid increase in school zone during the past 2 years because of problems in the designation and management of school zone. Traffic safety facilities such as road sign, reflector mirror, speed bump have the ultimate limit of vehicle accidents prevention. Thus, in school zone, children safety is still not guaranteed due to illegal parking and the absence of driver's awareness of safety. Therefore, In order to protect children from traffic accidents within school zones, we have realized a safe school zone system, which enables the drivers to better know the intended school zones and creates pedestrian environment through unmanned monitoring camera, using LabVIEW.

  • PDF

Spoilage Lactic Acid Bacteria in the Brewing Industry

  • Xu, Zhenbo;Luo, Yuting;Mao, Yuzhu;Peng, Ruixin;Chen, Jinxuan;Soteyome, Thanapop;Bai, Caiying;Chen, Ling;Liang, Yi;Su, Jianyu;Wang, Kan;Liu, Junyan;Kjellerup, Birthe V.
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.7
    • /
    • pp.955-961
    • /
    • 2020
  • Lactic acid bacteria (LAB) have caused many microbiological incidents in the brewing industry, resulting in severe economic loss. Meanwhile, traditional culturing method for detecting LAB are time-consuming for brewers. The present review introduces LAB as spoilage microbes in daily life, with focus on LAB in the brewing industry, targeting at the spoilage mechanism of LAB in brewing industry including the special metabolisms, the exist of the viable but nonculturable (VBNC) state and the hop resistance. At the same time, this review compares the traditional and novel rapid detection methods for these microorganisms which may provide innovative control and detection strategies for preventing alcoholic beverage spoilage, such as improvement of microbiological quality control using advanced culture media or different isothermal amplification methods.

A Study on Verification for the Design of Bio Safety Level 3 Laboratory by using Multi-zone Simulation (멀티죤 시뮬레이션을 이용한 생물안전 3등급(BSL3)시설의 설계 검증에 관한 연구)

  • Lee, Hyun-Woo;Choi, Sang-Gon;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.745-750
    • /
    • 2009
  • In Korea, since the implementation of the GMO Law, the intrest of biosafety level 3(BL3) lab. is increasing. In this study, using CONTAM which is applying multizone modelling, the multizone simulation for design verification of BL3 lab. was performed. In BL3 lab., because required air change rate is greater than general estimated air-conditioning load and it is difficult to maintain room pressure difference efficiently, to maintain pressure difference between laboratory rooms is important through sealing condition of doors and proper airflow control of laboratory rooms. In this study, about BL3 lab.(M. tuberculosis research lab.), the multizone simulation for four kind of biohazard scenarios was performed in the case of unexpected spread of contaminants in the laboratory room, anteroom, corridor and inside of BSC. Multizone simulation results show that these approach methods are used as a tool for the design and verification of BL3 lab.

  • PDF

An Analytical Study on the Prediction of Indoor Air Quality and the Reduction of Air Conditioning Load in Bio Safety Level 3 Laboratory (생물안전 3등급시설의 공기환경 예측 및 공조부하 절감에 대한 해석)

  • Hong, Jin Kwan;Park, Hyun Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.813-822
    • /
    • 2012
  • In this study, the multizone simulation for biosafety of BSL3 lab. and energy simulation are carried out simultaneously by using linked model of CONTAM and TRNSYS. In BSL3 lab., annual energy consumption is approximately five to ten times more than the magnitude of the office building. This is because required air change rate is extremely large and it is difficult to maintain room pressure difference efficiently. To maintain pressure difference between laboratory rooms through sealing condition of doors and proper airflow control is significant. In this study, to predict indoor environment of the BSL3 lab.(Influenza A research lab.), the multizone simulation for four kinds of biohazard scenario is also performed as part of risk assessment. Multizone and energy simulation results by using linked model show that these approaches are used as a tool for the energy efficient design and operation method for the safer BSL3 lab. facilities.

Perceptions of Elementary School Students about Science Learning and Lab Safety (초등학생들의 과학 학습과 실험 안전에 대한 인식 분석)

  • Park, Hyoung-Min;Lim, Chae-Seong
    • Journal of Korean Elementary Science Education
    • /
    • v.42 no.1
    • /
    • pp.82-92
    • /
    • 2023
  • In this study, we analyzed the perceptions of elementary school students about science learning and lab safety in the affective, behavioral, and cognitive domains. With respect to science learning, students indicated liking science classes more than average, being good at scientific inquiry more than average, and having more scientific knowledge than average. Compared with before the COVID-19 pandemic, student confidence in retaining scientific knowledge had decreased markedly. Of the eight student types in the students' awareness levels about affective·behavioral·cognitive domain, the HHH type-the most ideal-was also the most distributed. Students' preferred science class methods were experimental (72.7%) and nature inquiry classes (23.2%); science knowledge classes were ranked a distant third (4.1%). Preferred class locations were the science lab (58.1%) and different places from time to time (34.4%); the classroom was ranked last (7.5%). With respect to lab safety, most elementary school students did not have experimental classes, but more than half reported understanding how to use experimental equipment. Most students recognized the need to wear safety equipment in the lab. They were not only well aware of the associated physical protection functions, but also of the affective and psychological effects. Most students also recognized that first aid education is necessary, but only 31.5% reported understanding first aid methods. Based on those results, the implications for science learning and lab safety in school are discussed.

Safety Evaluation of the Adaptive Cruise Control System (감응순항제어장치(ACC)의 안전성 평가)

  • Yong, Boo-Joong;Shim, So-Jung;Yoon, Kyong-Han
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.159-164
    • /
    • 2007
  • The Advanced Safety Vehicle (ASV) allows drivers not only convenience and safety, but also many useful services provided by the Telematics technology. Since ASV is expected to be widely used in the near future, it is necessary to ensure the safety of ASV systems. Among several aspects of ASV, this paper investigates the safety of the Adaptive Cruise Control (ACC) system. Field tests are carried out under the domestic roadway and traffic conditions, according to International Standard Organization (ISO) requirements for ACC. The test data are analyzed whether the requirements are adequate for domestic circumstances, and the suggestions for findings are given.