• 제목/요약/키워드: unit work

검색결과 1,501건 처리시간 0.027초

C-arm의 Tube 위치에 따른 거리 및 방향별 피폭선량 비교 (A Comparision of the Radiation dose by Distance and the Direction according to a Tube Position of the C-arm Unit)

  • 김진수;우봉철;김성진;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.21-26
    • /
    • 2009
  • In operation room, the use of the C-arm unit is increasing. So, the radiation dose of the person who work in operation room was even more increased than before. Thus, this study is shown the measurement of expose dose and the way for decrease of the radiation dose by using the C-arm unit. The experiment was performed with the C-arm unit and used a phantom which is similar to tissue of the human body and fluoro-glass dosimeter for dose measurement. The expose dose were measured by the tube position(over tube, under tube) of the C-arm unit, distance(50, 100$\sim$200cm), direction(I, II, III, IV), runtime(1min, 3min), wearing of the apron. The radiation dose was decreased twice and three times at under tube rather than over tube. The I direction was measured 20$\sim$30% more than the others. The biggest expose dose is 50cm from center on distance. The expose dose is decreased to far from center. In case of Wearing of the apron, the radiation dose was decreased 60$\sim$90% by the distance. But there weren't change of the radiation dose by C-arm tube position. In present, by increasing the usage of the C-arm unit, the radiation dose is inevitable. So, this study recommends us to use the under tube of the C-arm unit. Also, Wearing of the apron is required for minimum of the radiation exposure.

  • PDF

환자중심의료를 위한 병동디자인이 환자가족 및 의료진에 미치는 효과에 대한 연구 - 미국의 환자중심의료를 위한 중환자병동 사례를 중심으로 (A Study on the Effect of Unit Design for Patient-Centered Care on Family Members and Caregivers - A Case Study of the Intensive Care Unit (ICU) for Patient-Centered Care in the United States)

  • 최영선
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제21권3호
    • /
    • pp.37-45
    • /
    • 2015
  • Purpose: The main objective of this paper is, to evaluate the unit design for patient-centered care and to draw lessons-learned for further improvement. Methods: This study conducted a case study of the intensive care unit, designed to fulfill patient-centered care in the US. It evaluated the effectiveness of the unit by incorporating several study methods such as plan analyses, direct observations through nursing tracking and behavior mapping, and focus group interviews. Results: The major design decision made in this patient-centered unit was the use of patient rooms with designated family areas and distributed nursing stations. Both design features appeared to be a success on a variety of research metrics and outcomes. The study identified that the patient rooms ultimately help family members to spent more time with their loved ones, which leads to increased satisfaction of family members and nurses also report that they generally enjoy the distributed nurses' stations, which provide a comfortable environment to complete their regular lines of work such as charting, monitoring patients, and collaborating with their colleagues. Implications: Certain design features in intensive care units such as patient rooms with designated family areas and distributed nursing stations could appropriately support hospitals to fulfill patient-centered care.

화재 시 일체형 방화셔터 작동유무에 따른 초등학생의 피난특성 (The Evacuation Characteristics of Elementary School Student According to Working of Single Unit Fireproof Shutter for Fires)

  • 이승철;홍이표;김상일
    • 한국화재소방학회논문지
    • /
    • 제27권4호
    • /
    • pp.35-40
    • /
    • 2013
  • 본 연구는 일체형 방화셔터가 설치된 초등학교 학생의 피난특성에 관한 연구이다. 구체적인 방법으로 일체형 방화셔터를 포함한 방화셔터 전반에 대한 기초 자료를 수집 검토하였으며, 초등학교에 설치된 일체형 방화셔터 작동 유무에 따른 재실자 피난특성을 비교 분석하였다. 화재 모의실험 결과, 일체형 방화셔터 미작동시 최종 대피완료 시간은 130초이며, 일체형 방화셔터 작동 시에는 190초가 소요되었다. 그리고 일체형 방화셔터 작동 시 피난대피 상황에서 초등학생들이 셔터내의 출입문을 열지 못하는 상황이 발생되었다. 이러한 상황을 고려한다면 일체형 방화셔터 작동 시 최종피난 완료시간은 상당히 지연될 수 있고, 많은 학생들이 화재위험에 노출될 수 있다. 따라서 향후 일체형 방화셔터 출입문 개폐력에 대한 연구가 반드시 진행되어야 할 것으로 생각된다.

Passive earth pressure for retaining structure considering unsaturation and change of effective unit weight of backfill

  • Zheng, Li;Li, Lin;Li, Jingpei;Sun, De'an
    • Geomechanics and Engineering
    • /
    • 제23권3호
    • /
    • pp.207-215
    • /
    • 2020
  • This paper presents a kinematic limit analysis for passive earth pressure of rigid retaining structures considering the unsaturation of the backfill. Particular emphasis in the current work is focused on the effects of the spatial change in the degree of saturation on the passive earth pressure under different steady-infiltration/evaporation conditions. The incorporation of change of effective unit weight with degree of saturation is the main contribution of this study. The problem is formulated based on the log-spiral failure model rather than the linear wedge failure model, in which both the spatial variations of suction and soil effective unit weight are taken into account. Parametric studies, which cover a wide range of flow conditions, soil types and properties, wall batter, back slope angle as well as the interface friction angle, are performed to investigate the effects of these factors on the passive pressure and the corresponding shape of potential failure surfaces in the backfill. The results reveal that the flow conditions have significant effects on the suction and unit weight of the clayey backfill, and hence greatly impact the passive earth pressure of retaining structures. It is expected that present study could provide an insight into evaluation of the passive earth pressure of retaining structures with unsaturated backfills.

A Simple and Reliable Molecular Detection Method for Tomato yellow leaf curl virus in Solanum lycopersicum without DNA Extraction

  • Yoon, Ju-Yeon;Kim, Su;Choi, Gug-Seoun;Choi, Seung-Kook
    • 식물병연구
    • /
    • 제21권3호
    • /
    • pp.180-185
    • /
    • 2015
  • In the present work, a pair of primers specific to Tomato yellow leaf curl virus (TYLCV) was designed to allow specific amplification of DNA fragments from any TYLCV isolates using an extensive alignment of the complete genome sequences of TYLCV isolates deposited in the GenBank database. A pair of primers which allows the specific amplification of tomato ${\beta}$-tubulin gene was also analyzed as an internal PCR control. A duplex PCR method with the developed primer sets showed that TYLCV could be directly detected from the leaf crude sap of infected tomato plants. In addition, our developed duplex PCR method could determine PCR errors for TYLCV diagnosis, suggesting that this duplex PCR method with the primer sets is a good tool for specific and sensitive TYLCV diagnosis. The developed duplex PCR method was further verified from tomato samples collected from some farms in Korea, suggesting that this developed PCR method is a simple and reliable tool for rapid and large-scale TYLCV detections in tomato plants.

초전도 Pipelined Multi-Bit ALU에 대한 연구 (Study of the Superconductive Pipelined Multi-Bit ALU)

  • 김진영;고지훈;강준희
    • Progress in Superconductivity
    • /
    • 제7권2호
    • /
    • pp.109-113
    • /
    • 2006
  • The Arithmetic Logic Unit (ALU) is a core element of a computer processor that performs arithmetic and logic operations on the operands in computer instruction words. We have developed and tested an RSFQ multi-bit ALU constructed with half adder unit cells. To reduce the complexity of the ALU, We used half adder unit cells. The unit cells were constructed of one half adder and three de switches. The timing problem in the complex circuits has been a very important issue. We have calculated the delay time of all components in the circuit by using Josephson circuit simulation tools of XIC, $WRspice^{TM}$, and Julia. To make the circuit work faster, we used a forward clocking scheme. This required a careful design of timing between clock and data pulses in ALU. The designed ALU had limited operation functions of OR, AND, XOR, and ADD. It had a pipeline structure. The fabricated 1-bit, 2-bit, and 4-bit ALU circuits were tested at a few kilo-hertz clock frequency as well as a few tens giga-hertz clock frequency, respectively. For high-speed tests, we used an eye-diagram technique. Our 4-bit ALU operated correctly at up to 5 GHz clock frequency.

  • PDF

연구용원자로 해체비용 산정을 위한 단위비용인자 산출 (Calculating the Unit Cost Factors for Decommissioning Cost Estimation of the Nuclear Research Reactor)

  • 정관성;이동규;정종헌;이근우
    • 방사성폐기물학회지
    • /
    • 제4권4호
    • /
    • pp.385-391
    • /
    • 2006
  • 연구용원자로 해체비용은 해체대상물에 대한 특성 및 제원에 맞게 해체작업을 분류하고 구성요소를 설정하여 단위비용인자를 바탕으로 한 공학적 비용 산정 방법으로 해체비용을 산정한다. 연구용원자로에 대한 해체비용은 크게 인건비, 장비 및 재료비로 구성이 되는데 해체작업에 소요되는 인건비는 해체대상물에 소요되는 작업시간을 바탕으로 계산을 한다. 본 논문에서는 연구용원자로 해체비용 산정 시 인건비 계산에 필요한 단위비용인자 및 작업 난이도 인자를 산출하였다.

  • PDF

Boron removal from model water by RO and NF membranes characterized using S-K model

  • Kheriji, Jamel;Tabassi, Dorra;Bejaoui, Imen;Hamrouni, Bechir
    • Membrane and Water Treatment
    • /
    • 제7권3호
    • /
    • pp.193-207
    • /
    • 2016
  • Boron is one of the most problematic inorganic pollutants and is difficult to remove in water. Strict standards have been imposed for boron content in water because of their high toxicity at high concentrations. Technologies using membrane processes such as reverse osmosis (RO) and nanofiltration (NF) have increasingly been employed in many industrial sectors. In this work, removal of boron from model water solutions was investigated using polyamide reverse osmosis and nanofiltration membranes. RO-AG, RO-SG, NF-90 and NF-HL membranes were used to reduce the boron from model water at different operational conditions. To understand the boron separation properties a characterization of the four membranes was performed by determining the pure water permeability, surface charge and molecular weight cut-off. Thereafter, the effect of feed pressure, concentration, ionic strength, nature of ions in solution and pH on the rejection of boron were studied. The rejection of boron can reach up to 90% for the three membranes AG, SG and NF-90 at pH = 11. The Spiegler-Kedem model was applied to experimental results to determine the reflection coefficient of the membrane ${\sigma}$ and the solute permeability $P_s$.

A MICROSTRUCTURAL MODEL OF THE THERMAL CONDUCTIVITY OF DISPERSION TYPE FUELS WITH A FUEL MATRIX INTERACTION LAYER

  • Williams, A.F.;Leitch, B.W.;Wang, N.
    • Nuclear Engineering and Technology
    • /
    • 제45권7호
    • /
    • pp.839-846
    • /
    • 2013
  • This paper describes a finite element model of the microstructure of dispersion type nuclear fuels, which can be used to determine the effective thermal conductivity of the fuels during irradiation. The model simulates a representative region of the fuel as a prism shaped unit cell made of brick elements. The elements within the unit cell are assigned material properties of either the fuel or the matrix depending on position, in such a way as to represent randomly distributed fuel particles with a size distribution similar to that of the as manufactured fuel. By applying an appropriate heat flux across the unit cell it is possible to determine the effective thermal conductivity of the unit cell as a function of the volume fraction of the fuel particles. The presence of a fuel/matrix interaction layer is simulated by the addition of a third set of material properties that are assigned to the finite elements that surround each fuel particle. In this way the effective thermal conductivity of the material may also be determined as a function of the volume fraction of the interaction layer. Work is on going to add fission gas bubbles in the fuel as a fourth phase to the model.

건축물 전과정 $CO_2$ 평가를 위한 BIM 라이브러리 개발 (The Development of BIM Library for Building Life Cycle CO2 Assessment)

  • 이병호;홍성욱;신성우
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권2호
    • /
    • pp.67-76
    • /
    • 2012
  • BIM and its quantity take-off widely apply to the construction projects and LCCO2 Assessment using the BIM's quantity take-off function can be tried recently. Because BIM modeling programs such as Revit and ArchiCAD do not provide adequate library for LCCO2 Assessment, quantity take-off data should be conversed and applied to Carbon Emission Coefficient using Excel program or manual work. Therefore, the purpose of this research is 1) to propose the Unit Conversion Systems for Carbon Emission Coefficient, 2) to provide basic library sets for BIM based LCCO2 Assessment method, and 3) to apply 11 material library sets on a apartment unit plan modeling to pursue the CO2 emission evaluation of the material production in the process of LCCO2 Assessment. Research results showed CO2 emission amount of 458.64kgCO2/m2 from the apartment unit plan modeling.