• 제목/요약/키워드: unit testing

Search Result 621, Processing Time 0.025 seconds

MICROTENSILE BOND STRENGTH ACCORDING TO DIFFERENT DENTIN WALL POSITIONS AND CURING LIGHTS IN CLASS I CAVITY OF PRIMARY MOLAR (유구치 I급 와동에서 와동벽 위치와 중합광원에 따른 Microtensile Bond Strength 비교 연구)

  • Lee, Hyeon-Heon;Jang, Chul-Ho;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.62-72
    • /
    • 2007
  • The purpose of present study was to determine whether different kinds of curing lights can alter microtensile bond strength(MTBS) of class I cavity pulpal and axial wall specimens in primary molar. Thirty clean mandibular 2nd primary molar's occlusal enamel were removed and class I cavity, size of $2{\times}4{\times}2mm$ was prepared. Dentin bonding agent was applied according to manufacturer's manual. Each group was cured with Halogen Curing Unit, Plasma Curing Unit and LED Curing Unit. Composite resin was bulk filled and photo cured with same curing unit. MTBS specimens which size is $0.7{\times}0.7{\times}4mm$ were prepared with low speed saw. Specimens were coded by their curing lights and wall positions (Halogen - Axial wall group, Halogen - Pulpal wall group, Plasma - Axial wall group, Plasma - Pulpal wall group, LED - Axial wall group, LED - Pulpal walt group). MTBS were tested at 1 mm/min cross Head speed by Universal Testing Machine. Fractured surface and bonding surface was observed with SEM. T-test between axial and pulpal specimens in each curing lights, one-way ANOVA among different curing light specimens in each wall positions were done. Weibull distribution analysis was done. The results were as follows : Mean MTBS of pulpal wall specimens were significantly greater than that of axial wall specimens at each curing units(p<.05). There was no significant difference in the MTBS among three curing units at axial wall and pulpal wall. In Weibull distribution, pulpal wall specimens were more homogeneous than axial wall specimens.

  • PDF

Measurement of Contact Angle and Bond Strength Using 3 Different Self-Etching Primer (3종의 자가부식 프라이머의 상아질계면 접촉각 및 미세인장결합강도에 관한 연구)

  • Chang, Seok-Woo;Kwon, Ho-Beom;Yoo, Hyun-Mi;Park, Dong-Sung;Oh, Tae-Seok;Bae, Kwang-Shik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.105-112
    • /
    • 2008
  • The purpose of this study was to evaluate the contact angle made by 3 kinds of self etching primers (Clearfil SE Bond, AdheSE, and Tyrian) on dentin and to measure the microtensile bond strength of resin composite to dentin using these self-etching primers. Contact angle between each of 3 self etching primers and polished dentin surface was measured (n=30) by contact angle analyzer and the result was analyzed by One-way ANOVA. For the measurement of microtensile bond strength, polished dentin surface was treated with each of 3 self etching primers and dentin adhesives. Z-250 composite resin was built-up with a height of 5 mm on the adhesive-treated surface and light cured for 40s with a halogen light curing unit. Thereafter, each tooth was sectioned into slabs perpendicular to the bonded interface and trimmed (n=45). The microtensile bond strength was measured with universal testing machine and the result was analyzed with Kruskal-Wallis test. AdheSE group showed the highest contact angle followed by Clearfil SE group and Tyrian group (p<0.05). AdheSE group and Clearfil SE group showed significantly higher microtensile bond strength than Tyrian group (P<0.05).

A neonate with hyperornithinemia-hyperammonemia-homocitrullinuria syndrome from a consanguineous Pakistani family

  • Kim, Yoo-Mi;Lim, Han Hyuk;Gang, Mi Hyeon;Lee, Yong Wook;Kim, Sook Za;Kim, Gu-Hwan;Yoo, Han-Wook;Ko, Jung-Min;Chang, Meayoung
    • Journal of Genetic Medicine
    • /
    • v.16 no.2
    • /
    • pp.85-89
    • /
    • 2019
  • Hyperornithinemia-hyperammonemia-homocitrullinuria (HHH) syndrome is a rare autosomal recessive urea cycle disorder. HHH is caused by a deficiency of the mitochondrial ornithine transporter protein, which is encoded by the solute carrier family 25, member 15 (SLC25A15) gene. Recently, government supported Korean newborn screening has been expanded to include a tandem mass spectrometry (MS/MS) measurement of ornithine level. We report a case of a neonate with HHH syndrome showing a normal MS/MS measurement of ornithine level. A female newborn was admitted to neonatal intensive unit due to familial history of HHH syndrome. Her parents were consanguineous Parkistani couple. The subject's older sister was diagnosed with HHH syndrome at age of 30 months based on altered mental status and liver dysfunction. Even though the subject displayed normal ammonia and ornithine levels based on MS/MS analysis, a molecular test confirmed the diagnosis of HHH syndrome. At 1 month of age, amino acid analysis of blood and urine showed high levels of ornithine and homocitrulline. After 11 months of follow up, she showed normal growth and development, whereas affected sister showed progressive cognitive impairment despite no further hyperammonemia after protein restriction and standard therapy. Our report is in agreement with a previous Canadian study, which showed that neonatal samples from HHH syndrome patients demonstrate normal ornithine levels despite having known mutations. Considering the delayed rise of ornithine in affected patients, genetic testing, and repetitive metabolic testing is needed to prevent patient loss in high risk patients.

The Investigative Study on the Small-sized Isolation Device: regarding of the isolation performance and function test In Emergency Disaster Circumstances (재난현장 소형격리장비의 성능 및 기능평가에 관련된 탐색적 연구)

  • Choi, Jin Woo;Haam, Sunnie;Yoon, Myuong O
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.135-141
    • /
    • 2020
  • The first case of Middle East Respiratory Syndrome (MERS) was reported in Korea in 2015, after a Korean man from Bahrain tested positive for the infection. After first eruption, there were numbers of secondary infectees and whole country were frightened. At the time, isolated ambulances were available but few, and there was no specific way to prevent contamination during transfer. Therefore, Seoul National University Hospital and the University of Seoul developed isolation units and air filters. Four years after the MERS outbreak, this study measured the differential pressure inside and outside the small isolation units based on the differential pressure and air flow derived from simulation and testing, and proposed minimum values for virus leakage and internal sealing. A performance evaluation and testing method for the transfer equipment is proposed. The critical function of the small isolated transport equipment was defined and selected as an evaluation item; performance evaluation was carried out by simulating a real-world case. The results provide the proper pressure configuration of positive and negative pressure inside the segregation feeder; the clear criteria for the HEPA filter; and the performance criteria for the segregation feeder and air purifier.

Artificial Neural Network System in Evaluating Cervical Lymph Node Metastasis of Squamous Cell Carcinoma (편평세포암종 임파절 전이에 대한 인공 신경망 시스템의 진단능 평가)

  • Park Sang-Wook;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.149-159
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate cervical lymph node metastasis of oral squamous cell carcinoma patients by MRI film and neural network system. Materials and Methods: The oral squamous cell carcinoma patients(21 patients. 59 lymph nodes) who have visited SNU hospital and been taken by MRI. were included in this study. Neck dissection operations were done and all of the cervical lymph nodes were confirmed with biopsy. In MR images. each lymph node were evaluated by using 6 MR imaging criteria(size. roundness. heterogeneity. rim enhancement. central necrosis, grouping) respectively. Positive predictive value. negative predictive value. and accuracy of each MR imaging criteria were calculated. At neural network system. the layers of neural network system consisted of 10 input layer units. 10 hidden layer units and 1 output layer unit. 6 MR imaging criteria previously described and 4 MR imaging criteria (site I-node level II and submandibular area. site II-other node level. shape I-oval. shape II-bean) were included for input layer units. The training files were made of 39 lymph nodes(24 metastatic lymph nodes. 10 non-metastatic lymph nodes) and the testing files were made of other 20 lymph nodes(10 metastatic lymph nodes. 10 non-metastatic lymph nodes). The neural network system was trained with training files and the output level (metastatic index) of testing files were acquired. Diagnosis was decided according to 4 different standard metastatic index-68. 78. 88. 98 respectively and positive predictive values. negative predictive values and accuracy of each standard metastatic index were calculated. Results: In the diagnosis of using single MR imaging criteria. the rim enhancement criteria had highest positive predictive value (0.95) and the size criteria had highest negative predictive value (0.77). In the diagnosis of using single MR imaging criteria. the highest accurate criteria was heterogeneity (accuracy: 0.81) and the lowest one was central necrosis (accuracy: 0.59). In the diagnosis of using neural network systems. the highest accurate standard metastatic index was 78. and that time. the accuracy was 0.90. Neural network system was more accurate than any other single MR imaging criteria in evaluating cervical lymph node metastasis. Conclusion: Neural network system has been shown to be more useful than any other single MR imaging criteria. In future. Neural network system will be powerful aiding tool in evaluating cervical node metastasis.

  • PDF

Study on the Present Status of Practicum of Fundamentals of Nursing and Test for Competency of Nursing Skills (기본간호학 실습교육현황과 실기능력 평가방법에 관한 조사)

  • Kim, Jong-Im;Kim, Kyung-Hee;Paik, Hoon-Jung;Sohng, Kyeong-Yae;Eom, Mi-Ran;Oh, Sei-Young;Lee, Woo-Sook;Chang, Ock-Ja;Jeon, Hyen-Sook;Lee, Dong-Suk
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.17 no.3
    • /
    • pp.362-370
    • /
    • 2010
  • Purpose: In this study the present status of the practicum in Fundamentals of Nursing and test for student competency in nursing skills were surveyed. Method: Participants included 72 nursing schools. A structured questionnaire was used for data collection and SPSS 17.0 for data analysis. Results: Credits for Fundamentals of Nursing, credits for practicum and hours per credit were 2.93, 7.34, and 2.14 respectively. Number of students per practice unit, full time assistants and students per assistant were 28.6, 0.6, and 20.2 respectively. Utilization of CPX room and OSCE room for practice was 5.6%, and 9.7% respectively. Of the school, 32.0% included clinical practice in the practicum. 90.3% provided an open lab but only 48.4% had full-time assistants for these clinical practice areas. Testing for nursing skill competency was performed twice a semester in most schools. Utilization of standard patients and high fidelity models for testing was 8.3%, and 23.6% respectively. The test was thought to be inappropriate in 33.4% of the schools. Conclusions: The results suggest that to improve the outcomes, the practicum for Fundamentals of Nursing needs to be changed to include expansion of facilities and human resources, utilization of standard patients and high fidelity models and development of appropriate test methods.

Measurement of Width and Step-Height of Photolithographic Product Patterns by Using Digital Holography (디지털 홀로그래피를 이용한 포토리소그래피 공정 제품 패터닝의 폭과 단차 측정)

  • Shin, Ju Yeop;Kang, Sung Hoon;Ma, Hye Joon;Kwon, Ik Hwan;Yang, Seung Pil;Jung, Hyun Chul;Hong, Chung Ki;Kim, Kyeong Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.18-26
    • /
    • 2016
  • The semiconductor industry is one of the key industries of Korea, which has continued growing at a steady annual growth rate. Important technology for the semiconductor industry is high integration of devices. This is to increase the memory capacity for unit area, of which key is photolithography. The photolithography refers to a technique for printing the shadow of light lit on the mask surface on to wafer, which is the most important process in a semiconductor manufacturing process. In this study, the width and step-height of wafers patterned through this process were measured to ensure uniformity. The widths and inter-plate heights of the specimens patterned using photolithography were measured using transmissive digital holography. A transmissive digital holographic interferometer was configured, and nine arbitrary points were set on the specimens as measured points. The measurement of each point was compared with the measurements performed using a commercial device called scanning electron microscope (SEM) and Alpha Step. Transmission digital holography requires a short measurement time, which is an advantage compared to other techniques. Furthermore, it uses magnification lenses, allowing the flexibility of changing between high and low magnifications. The test results confirmed that transmissive digital holography is a useful technique for measuring patterns printed using photolithography.

Experimental Assessment and Specimen Height Effect in Frost Heave Testing Apparatus (동상시험장비의 실험적 검증 및 시료크기의 영향에 관한 연구)

  • Jin, Hyunwoo;Ryu, Byunghyun;Lee, Jangguen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Frost heave is one of the representative engineering characteristics in cold regions. In South Korea, which is located in seasonal frost area, structural damage caused by frost heave and thaw happens and the need for research on the frost heave is increasing. In this paper, newly developed transparent temperature-controllable cell is used to focus on the frost heave. Frost susceptible artificial soil is used to analyze water intake rate which is one of the important factors in frost susceptibility criteria. Frost heave rate and water intake rate have similar behavior after heave by freezing of pore water converges. O-ring installed in the upper pedestal to measure water intake rate generates side friction between the inner wall of the freezing cell and O-ring, thereby hindering frost heave. Therefore, the frost susceptibility criteria using the water intake rate is not reliable. It is appropriate to use frost heave rate which has similar behavior with water intake rate. Frost heave tests were performed under two different specimen heights. Overburden pressure, temperature gradient and dry unit weight were set under similar state. Based on laboratory testing results, frost heave is independent on the specimen height.

Materials Compatibility and Structure Optimization of Test Department Probe for Quality Test of Fingerprint Sensor (지문인식센서 품질평가를 위한 검사부 프로브의 소재 적합성과 구조 최적화 연구)

  • Son, Eun-Won;Youn, Ji Won;Kim, Dae Up;Lim, Jae-Won;Kim, Kwang-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.73-77
    • /
    • 2017
  • Recently, fingerprint sensors have widely used for personal information security, and require quality evaluation to reduce an error of their recognition rate. Quality of fingerprint sensors is evaluated by variation of their electrical resistance introducing by contacts between a probe tip and a sensor electrode, Investigation on the materials compatability and structure optimization of probe is required to reduce deformation of sensor electrode for repeatability of quality testing. Nickel, steel(SK4), beryllium copper, and phosphor bronze were considered as probe materials, and beryllium copper was the most appropriate for materials of probe tips, considering indentation and contact resistance while being contacted probe tips on electrodes. Probes of an inspection part were manufactured with the single-unit structure for physical damage prevention and parallel processing capability. Inspection repeatability was evaluated by voltage variation of fingerprint sensors when the specific current was applied. A single-unit inspection part with beryllium copper probe tips showed excellent repeatability within ${\pm}0.003V$ of its voltage variation.

Simultaneous Removal of $SO_2/NO$ using liquid Homogeneous Catalyst (액상 균일질 촉매를 이용한 $SO_2/NO$ 동시 처리 기술 개발)

  • Jung, Seung-Ho;Bae, Jin-Youl;Park, Don-Hee;Jung, Kyung-Hoon;Cha, Jin-Myeong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.62-67
    • /
    • 2007
  • It was investigated to develop the technology for simultaneous removal of $SO_2/NO$ in flue gas using liquid homogeneous catalyst. Test was carried out using a bench scale and a pilot scale experiment. The investigation led to the following results: 1) Removal efficiency of $SO_2$ gas showed good results regardless of operating condition. Removal efficiency of NO gas, however, proportionally increased with higher packing height, lower concentration and larger injection rate of catalyst 2) The optimum design parameters for simultaneous removal of $SO_2/NO$ gas using Fe(II)-EDTA catalyst were as follow: HTU(height of transfer unit) = 0.5 m, liquid gas ratio = 20 $L/m^3$, NTU (number of transfer unit) = 3 stages, cross dimension of scrubber=0.025 $m^2$ 3) The removal efficiencies of $SO_2$ and NO were 95% and 81%, repletely. 4) The high HTU is advantageous on removal of the NO, but the excessive HTU diminishes operating efficiency. Consequently, it is important to decide the HTU of optimum.