• Title/Summary/Keyword: unit system

Search Result 8,843, Processing Time 0.039 seconds

CONFIDENCE LIMITS FOR STEADY STATE AVAILABILITY OF A REDUNDANT SYSTEM

  • Shin, Sang-Wook;Lim, Jae-Hak;Park, Dong-Ho
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2000.04a
    • /
    • pp.193-200
    • /
    • 2000
  • In this paper, we consider confidence limits for steady state availability of a redundant structure with the function of switchover processing. The system considered in this paper consists of three units which are an active unit, a standby unit and a switchover device. A control module does not affect the performance of the system while the active unit is operating but causes the system failure if the active unit fails at the failure of the control module. The effect of failure of control module is included in our reliability model of the simple redundant structure. The availability of the system is obtained by using the state space method. An example is given to illustrate our results.

  • PDF

A Study on Driving Motor Performance Comparison for Load Efficiency Improvement of a Bicycle Locker System (자전거 거치대 잠금장치의 부하시 효율개선을 위한 구동모터성능비교에 관한 연구)

  • Han, Ki-Soo;Won, Sung-Hong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.175-180
    • /
    • 2013
  • This paper presents the design and implementation of a Bicycle Locker System. Generally DC motor has been used to control a Bicycle Locker System, but DC motor system requires frequent maintenances and its power efficiency is comparatively poor especially under heavy load conditions. In order to improve this difficulties, this paper adopts BLDC motor for a Bicycle Locker System and its motor controller is developed. The performances of locker units are compared between DC motor unit and BLDC motor unit. The motor power consumptions between two motors are discussed. Test results verify that power efficiency of the suggested BLDC drive unit is considerably improved compared to the DC drive unit with load condition.

Evaluation of Pollutant Load Unit Factor for Calculating Pollutants Emission in Aquacultural Farms (양식계 오염원 배출량 산정을 위한 원단위 설정)

  • Park, Jae Hong;Park, Bae Kyoung;Rhew, Doug Hee;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.656-665
    • /
    • 2013
  • This research was conducted to investigate pollutant load unit factor from aquacultural farms. Pollutant load unit factors were investigated on the 13 kinds of fish type, i.e., Trout, Leather Carp, Eel, Carp, Cartfish, Freshwater Eel, Crucian Carp, Colored Carp, Sturgeon, Marsh Snail, Sweetfish, Pond Snail, Eriocheir Sinensis. Water qualities in aquacultural farms were investigated wide range of values by fish type and pollutant items. High BOD and COD values were observed at the Leather Carp (Ponded water system), Cartfish (Ponded water system) and Freshwater Eel (Recirculating System). TOC and DOC values were relatively high at the Freshwater Eel (Recirculating System) and Eriocheir Sinensis (Extensive). Eel (Ponded water system) and Freshwater Eel (Recirculating System) produced high concentrated nutrient pollutants, i.e., T-N, T-P. Pollutant load unit factors are dependent on fish type, aquacultural type, water quality items, etc. If some fishes have similar basic unit values, those could be applied for TMDLs as a group of fish having same pollutant load unit. The water quality concentrations of post treatment facilities' (mainly reservoir tank) effluent were higher than those of fish raising bath because of extracting pollutant from sediment in the reservoir tank. Therefore, it needs to the management and regulations about post treatment facilities.

A Guide to Education on Unit Transformation in University Liberal Arts Education (대학 교양교육에서 단위변환에 대한 교육 방향 제시)

  • kyung a jeong;hye jeong kim
    • Journal of Integrative Natural Science
    • /
    • v.16 no.4
    • /
    • pp.133-138
    • /
    • 2023
  • After the SI system of units was adopted as an international system of units, Korea made a lot of efforts such as administrative and educational guidance on the traditional units that had been used so far. In addition, from July 1, 2007, the government has cracked down on the denotation of non-statutory units of measurement as standard units or auxiliary units in commercial transactions. However, non-statutory weighing units are still used in other forms. It is believed that this is because non-statutory units (= our traditional units) are permeated in our lives and are convenient to use. The general public still finds it difficult to use and mark the SI system of units correctly. This is not a problem unique to Korea. However, if you look at the books that are currently used as university physics textbooks, the SI system of units and the non-legal units of other countries are marked in such a way that they can be accurately converted. Only the traditional units of our country are disappearing under the pretext of unit unification. Accordingly, we propose that our units should not be neglected in university education, but should be labeled together. The purpose of this study is to raise the necessity of reorganizing the unit conversion between the SI unit system and the traditional life improvement unit, which continues to be the convenience of life, and applying it in university physics education to enable the conversion with our traditional unit, and to educate the importance of the meaning and function of our traditional unit.

A Basic Study of Cane To Assist Blind Walker with ultrasonic Sensor (초음파 센서를 이용한 시각장애자용 보행유도 지팡이에 관한 기초연구)

  • Kim, S.Y.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.411-413
    • /
    • 2002
  • In this paper we researched about the ultrasonic cane which aids the blind to walk. We used ultrasonic in recognizing the object and implemented pulse counting method in measuring the distance. The distance measuring system consists of transmitter unit, receiver unit and micro-processor. We used broadband ultrasonic sensors in transmitter unit and receiver unit. The blind is able to recognize the distance between obstacles and himself as it used a vibration system.

  • PDF

An Experimental Study on the Comfortable Room Control Conditioning Using Personal Computer (컴퓨터를 이용한 가정용 냉방기기의 실내쾌적조건 조절에 관한 실험적 연구)

  • Cho, Jin Ho;Lee, Dae Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.442-447
    • /
    • 1988
  • To keep comfortable indoor condition, the existing air conditioning system is controlled by the ON/OFF temperature controller. The PID control unit is developed to control temperature and humidity simultaneously, and the Air-conditioning control system is transferred from the ON/OFF temperature controller to the PID control unit for experiment. As a result of this experiment, the PID control unit reduced energy consumption compared with the ON/OFF control unit.

  • PDF

CUMAP : A Chill Unit Calculator for Spatial Estimation of Dormancy Release Date in Complex Terrain (Chill Unit 축적과 휴면해제시기 공간변이 추정 프로그램 : CUMAP)

  • Kim Kwang S.;Chung U ran;Yun Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.3
    • /
    • pp.177-182
    • /
    • 2004
  • A chill unit has been used to estimate chilling requirement for dormancy release and risk of freezing damage. A system that calculates chill units was developed to obtain site-specific estimates of dormancy release date for grapes and evaluated in Baekgu myun near Kimje City, Chunbuk, Korea from September 2002 to March 2003. The system utilized daily minimum and maximum temperature maps generated from spatial interpolation with temperature correction for topography. Hourly temperature was temporally interpolated from the daily data using a sine-exponential equation (Patron and Logan, 1981). Hourly chill units were determined from sigmoid, reverse sigmoid, and negatively increasing sigmoid functions based on temperature ranges and summed for 24 h. Cumulative daily chill units obtained from measurements did not increase until 20 October 2002, which was used as a start date for accumulation to estimate the dormancy release date. As a result, a map of dormancy release date in the study area was generated, assuming 800 chill units as a threshold for the chilling requirement. The chill unit accumulation system, implemented using Microsoft Visual Basic and C++ (Microsoft, Redmond, WA, USA), runs in the Windows environment with ArcView (ESRl Inc., Redlands, CA, USA).

A Study on the Cost Estimating Method based on Spatial Unit Focused on Improving Limitation Caused by Lack of Spatial Information of the Cost Based on Work Type (공간단위 공사비 산정방법에 관한 연구 - 공종별 공사비의 공간정보 부재로 인한 한계점 개선을 중심으로 -)

  • Lee, Ki-Sang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.3
    • /
    • pp.131-139
    • /
    • 2011
  • In this Study, the Cost of Public Facility Construction in the VE Cost Model, and the Progress of the Construction Site Management, and Cost due to the Lack of Cpatial Information in Dispute Cost Work Type Recognize the limits of Historical Information, and to Overcome the Perception of Cost and Space Systems Unit In the Process of Transition that Began Seeking Ways to Improve Through this Study, Different Parts of the Proposed Area of Construction Work Unit System, the Core of Calculating Hourly and Detailed Engineering Information and Cost Information Generated Extension to Configure the Construction Unit in Every Space, Every Work Unit System, All Materials That Make Up Work Unit System, Unit Labor Costs, And All of the Configuration Items Enables Precise And Multidimensional Understanding is That.

The Power Supply System for Xenon Lamp Light Sintering (광소결용 제논 램프 구동을 위한 파워 서플라이 시스템)

  • Cho, Chan-Gi;Song, Seung-Ho;Park, Su-Mi;Park, Hyeon-Il;Bae, Jung-Soo;Jang, Sung-Roc;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.327-328
    • /
    • 2017
  • This paper presents the power supply system which is made of three units: the capacitor charging and main pulse unit, simmer power supply unit, and series trigger unit. The capacitor charging and main pulse unit charges the capacitor bank by using the series parallel resonant converter and the generated main pulses apply to the lamp. The series trigger unit ionize the xenon gas located in the lamp and the simmer power supply unit sustains the ionized condition. It means that the lamp lifetime and efficiency are advanced by reducing the number of triggering. Not only the operation of the proposed system but also the performance of each unit will be verified by the experimental results.

  • PDF

Estimating the Home-Purchase Cost of Seoul Citizens

  • Oh, Deok-Kyo;Burns, James R.
    • Korean System Dynamics Review
    • /
    • v.12 no.2
    • /
    • pp.5-36
    • /
    • 2011
  • Seoul citizens are currently suffering from high housing price. Home prices have risen more rapidly than salaries so owning a housing unit (apartment, condominium, or single-family home) in Seoul is becoming more difficult than ever. Therefore, this research examines the behavior of average Seoul citizen in owning housing unit in Seoul, Korea, particularly in terms of the length of time required to afford a house unit. This research estimates that it will take about 18.75 years in maximum after getting a job (12.75 years after purchasing the housing unit) to own housing unit in Seoul that is currently valued at $300,000 where the growth rate of income is 2.97% and consumption price increases at a rate of 2.95% per annum. Finally in this research, the optimal growth rate of housing price is estimated ranged from 3.5 to 4.0% minimizing the loan payoff period.

  • PDF