• Title/Summary/Keyword: unit size

Search Result 2,216, Processing Time 0.034 seconds

The Opening Size Change for Screen Tension (스크린 망사의 견장과 오프닝의 변화)

  • Jung, Gi-Young;Kang, Young-Reep
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.28 no.1
    • /
    • pp.43-50
    • /
    • 2010
  • The 200mesh screen was tensioned and fixed on a frame. When applied tension to 5N and 10N per unit area, a side length of opening of the screen was 163.223${\mu}m$ and 168.224${\mu}m$, respective. But side length not tensioned was 158.879${\mu}m$. We knew that a side length of opening of the screen rarely changes with tension applied to the screen. The appearances that a side length of opening of the screen expand little are due to a decreasing diameter of thread by means of tension. In a thickness measurement of screen, While the high density mesh screen that had a lot of knots that crossed a line of latitude and longitude per unit area appeared a higher numerical value, the low density mesh screen that had a few knots appeared a low numerical value.

A Production and Preventive Maintenance Policy with Two Types of Failures (두 가지 고장형태를 고려한 생산 및 예방보전 정책)

  • 김호균;조형수
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.3
    • /
    • pp.53-65
    • /
    • 2002
  • This paper studies an economic manufacturing quantity (EMQ) model with two types of failures and planned preventive maintenance of the production facility. One is a type I (major) failure which should be corrected by a failure maintenance and the other is a type H (minor) failure which can be minimally repaired without interrupting the production run. The objective is to determine the lot size and preventive replacement policy minimizing the long-run expected cost per unit time. We consider a control policy with a constant production lot size and preventive maintenance after completing n production runs. It is assumed that both preventive and failure maintenance times are random and the demand arriving during a stock-out period is lost. An expression for the expected cost per unit time is obtained in the general case. A special case is discussed and numerical results are provided.

Development of HVAC System to Lower the Conveyance Energy and Building Height (반송동력과 건물층고 저감형 공조시스템 개발)

  • 김정엽;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.116-125
    • /
    • 2003
  • The new HVAC system to lower the conveyance energy and building height using IAV (Increasing Air Volume) technique is developed. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy, size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 per-centage.

New Types of Constrained Geometry Catalysts Containing Silacycloalkyl Bridging Unit: Synthesis, Structure, and Polymerization Activity

  • Ok, Myung-Ahn;Hahn, Jong-Sok;Jung, Jae-Ho;Kang, Sang-Ook
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.222-222
    • /
    • 2006
  • New types of constrained geometry complexes comprising rigid silacycloalkyl group incorporated into the bridging position between cyclopentadienyl and amido functionalities were prepared. The catalytic activities of olefin polymerization were influenced by the change of exo-cyclic ring size on bridge-head silacycloalkyl unit. It has been noted that the activities of this unique series increase with increasing size of the silacycloalkyl bridge and reach the maximum in six-membered silacyclohexyl-bridged CGC complex. It is noteworthy that conformation of silacycloalkanes gives rise to enhanced catalytic activity of the titanium center although the cyclic ring and titanium center are far remoted from each other.

  • PDF

Dynamic Characteristic Improvement of Laser Scanning Unit for Laser Beam Printer (레이저 프린터용 광스캔유닛(LSU) 의 동특성 개선)

  • 조문선;차덕순
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.189-193
    • /
    • 2001
  • The performance of printer can be determined by the printing speed, noise level, printing quality which includes the resolution, regularity of printed matter and etc. Among them, printing quality mostly depends on the irregularity of the line spacing and dot size. The irregular line spacing and dot size in laser beam printer are mainly from the jitter which comes from the vibration of Organic Photo Conductive(OPC) drum and the Laser Scanning Unit(LSU). Jitter due to the vibration of LSU appears as high-frequency component which occurs 100-300$\mu\textrm{m}$ interval in printed matter and the causes of it can be estimated as the vibration of polygon motor, case, reflecting mirror and etc. In this paper, vibration characteristics of the LSU under development are investigated and the strategy for improvement of the dynamic characteristics is established and its validity is demonstrated.

  • PDF

The Economic Design of VSS $\bar{x}$ Control Chart for Compounding Effect of Double Assignable Causes (두 가지 복합 이상원인 영향이 있는 공정에 대한 VSS$\bar{x}$관리도의 경제적 설계)

  • Sim Seong-Bo;Kang Chang-Wook;Kang Hae-Woon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.2
    • /
    • pp.114-122
    • /
    • 2004
  • In statistical process control applications, variable sample size (VSS) $\bar{X}$ chart is often used to detect the assignable cause quickly. However, it is usually assumed that only one assignable cause results in the out-of-control in the process. In this paper, we propose the algorithm to minimize the function of cost per unit time and compare the economic design and the statistical design by use of the value of cost per unit time. We consider double assignable causes to occur with compound in the process and adopt the Markov chain approach to investigate the statistical properties of VSS $\bar{X}$ chart. A procedure that can calculate the control chart's parameters is proposed by the economic design.

A Study of Models for Marketing Strategy in the Eco-friendly Apartment Housing Using Discriminant Analysis (판별분석을 이용한 친환경 아파트의 마케팅 전략에 관한 연구)

  • Kil, Ki-Suck;Lee, Joo-Hyung
    • KIEAE Journal
    • /
    • v.7 no.3
    • /
    • pp.11-20
    • /
    • 2007
  • The purpose of this study is to analyse the effects of the eco-friendly factors on the apartment housing price rise and to suggest the desirable way of marketing strategy for apartment housing. For the analysis, the data of apartment sites in Seoul had been collected from September 2006 to February 2007. The data consisted of 95 apartment sites in Seoul. Data were analyzed with descriptives, crosstabs, and discriminant analysis by SPSS/PC for Window. Following result was obtained. The eco-friendly apartment housing price rate in Seoul was determined by eco-friendly landscape, green space rate, house unit size, installment sale price per pyeong, floor space index, distance from subway station when it was not considered the impact of building age, construction company's brand, and autonomous districts. Findings of this research can provide valuable information for marketing strategy of housing construction company.

Development of HVAC System to Lower the Conveyance Energy and Building Height

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.31-43
    • /
    • 2005
  • The new HVAC system is developed to lower the conveyance energy and building height using IAV(Increasing Air Volume) technique. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy. size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 percentage.

An Experimental Study on Optimal Size of Core Material in Rubble Mould Breakwater (사석 방파제에서 내부사석의 적정규격에 관한 실험적 연구)

  • 민석진;배종철;김성득
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.16-21
    • /
    • 2004
  • In general, core materials of rubble mound breakwater are used at a restricted range of 0.015㎥~0.03㎥. However, it is not satisfied with the standard design in over fifty percent of the cases. In this study, model tests and numerical analysis are employed to examine the range of core material that has no problem with capacity maintenance and stability of rubble mound breakwater. Model tests measure the porosities that are mixed in various ratios, to classify core materials by three parameters. The slope stability of rubble mound breakwater is investigated, using numerical analysis, with a friction angle and a unit weight. The change of unit weight, which is followed by the mixed rate of size core material, has no large affect on slope stability, and there is no problem with ensuring slope stability of the rubble mound breakwater.

Evaluation of spatial pressure distribution during ice-structure interaction using pressure indicating film

  • Kim, Hyunwook;Ulan-Kvitberg, Christopher;Daley, Claude
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.3
    • /
    • pp.578-597
    • /
    • 2014
  • Understanding of 'spatial' pressure distribution is required to determine design loads on local structures, such as plating and framing. However, obtaining a practical 'spatial' pressure distribution is a hard task due to the sensitivity of the data acquisition frequency and resolution. High-resolution Pessure-Idicating Flm (PIF) was applied to obtain pressure distribution and pressure magnitude using stepped crushing method. Different types of PIF were stacked at each test to creating a pressure distribution plot at specific time steps. Two different concepts of plotting 'spatial' pressure-area curve was introduced and evaluated. Diverse unit pixel size was chosen to investigate the effect of the resolution in data analysis. Activated area was not significantly affected by unit pixel size; however, total force was highly sensitive.