• Title/Summary/Keyword: unit load system

Search Result 743, Processing Time 0.029 seconds

A completely non-contact recognition system for bridge unit influence line using portable cameras and computer vision

  • Dong, Chuan-Zhi;Bas, Selcuk;Catbas, F. Necati
    • Smart Structures and Systems
    • /
    • v.24 no.5
    • /
    • pp.617-630
    • /
    • 2019
  • Currently most of the vision-based structural identification research focus either on structural input (vehicle location) estimation or on structural output (structural displacement and strain responses) estimation. The structural condition assessment at global level just with the vision-based structural output cannot give a normalized response irrespective of the type and/or load configurations of the vehicles. Combining the vision-based structural input and the structural output from non-contact sensors overcomes the disadvantage given above, while reducing cost, time, labor force including cable wiring work. In conventional traffic monitoring, sometimes traffic closure is essential for bridge structures, which may cause other severe problems such as traffic jams and accidents. In this study, a completely non-contact structural identification system is proposed, and the system mainly targets the identification of bridge unit influence line (UIL) under operational traffic. Both the structural input (vehicle location information) and output (displacement responses) are obtained by only using cameras and computer vision techniques. Multiple cameras are synchronized by audio signal pattern recognition. The proposed system is verified with a laboratory experiment on a scaled bridge model under a small moving truck load and a field application on a footbridge on campus under a moving golf cart load. The UILs are successfully identified in both bridge cases. The pedestrian loads are also estimated with the extracted UIL and the predicted weights of pedestrians are observed to be in acceptable ranges.

Centralized Adaptive Under Frequency Load Shedding Schemes for Smart Grid Using Synchronous Phase Measurement Unit

  • Yang, D.Y.;Cai, G.W.;Jiang, Y.T.;Liu, C.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.446-452
    • /
    • 2013
  • Under frequency load shedding (UFLS) is an effective way to prevent system blackout after a serious disturbance occurs in a power system. A novel centralized adaptive under frequency load shedding (AUFLS) scheme using the synchronous phase measurement unit (PMU) is proposed in this paper. Two main stages are consisted of in the developed technique. In the first stage, the active power deficit is estimated by using the simplest expression of the generator swing equation and static load model since the frequency, voltages and their rate of change can be obtained by means of measurements in real-time from various devices such as phase measurement units. In the second stage, the UFLS schemes are adapted to the estimated magnitude based on the presented model. The effectiveness of the proposed AUFLS scheme is investigated simulating different disturbance in IEEE 10-generator 39-bus New England test system.

Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed (우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정)

  • Kim, Kyung-Tae;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong;Seong, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.

Study of improvement control logic about unit master control(UMC) (Unit master control(UMC) 제어로직 개선에 관한 연구)

  • Park, Doo-Yong;Lim, Gyun-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1707_1708
    • /
    • 2009
  • Unit master control(UMC)는 발전소의 요구 부하신호를 설정하는 최상위의 제어레벨이며 UMC의 설정값은 자동급전 지령신호(Automatic Dispatch System : ADS) 또는 운전원이 설정하는 값에 따라 보일러 및 터빈 Master에 Unit 요구 신호를 출력하여 하위제어 레벨인 공기, 연료, 급수 등을 조절할 수 있는 기기에 Unit 부하 요구 신호(Unit Load Demand : ULD)에 따라 제어 되도록 하는 방법으로서, Unit 목표부하 설정, Unit 목표부하 상/하한 제한, 목표부하 변화율 제한, 주파수 보정, Runback/Rundown/ Runup, 보일러 및 터빈 Demand 신호생성의 기능을 가지고 있다.

  • PDF

Design of the Boiler Load Distribution System (보일러 본체 지지장치 하중교정 시스템 설계)

  • Park, Jong-Beom;Bae, Byung-Hong;Lee, Sang-Guk;Choi, Jong-Ki;Baek, Soo-Gon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.778-780
    • /
    • 2000
  • Due to the long time operation of the thermal power plant boiler. the load redistribution of the sling rods is occurred. To enlarge the sincerity of the boiler. measuring and adjusting the actual load of the sung rods is required. The original targets were reached from the 1-year-study. Survey related to the load distribution system for the boiler, systematic design of the hydraulic unit and hydro cylinder, detailed design of the hydraulic unit and hydro cylinder.

  • PDF

A Maintenance Policy Determination of Dependent k-out-of-n:G System with Setup Cost (초기설치비를 고려한 의존적 k-out-of-n:G 시스템의 보전정책 결정)

  • 조성훈;안동규;성혁제;신현재
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.155-162
    • /
    • 1999
  • reliability from components reliability. In this case, it assumes that components failure is mutually independent, but it may not true in real systems. In this study, the mean cost per unit time is computed as the ratio of mean life to the mean cost. The mean life is obtained by the reliability function under power rule model. The mean cost is obtained by the mathematical model based on the inspection interval. A heuristic method is proposed to determine the optimal number of redundant units and the optimal inspection interval to minimize the mean cost per unit time. The assumptions of this study are as following : First, in the load-sharing k-out-of-n:G system, total loads are applied to the system and shared by the operating components. Secondly, the number of failed components affects the failure rate of surviving components as a function of the total load applied. Finally, the relation between the load and the failure rate of surviving components is set by the power rule model. For the practical application of the above methods, numerical examples are presented.

  • PDF

Study on the Characteristic of System Frequency Decay In Case of Large Generator Unit Outage (전원탈락에 따른 계통주파수저하문제검토 제1보)

  • 송길영
    • 전기의세계
    • /
    • v.18 no.3
    • /
    • pp.7-14
    • /
    • 1969
  • According to the construction of Seoul Thermal #5 (250MW) unit, there will be prospected several new problems on the power system operation. This paper describes the characteristic of system frequency decay during severe emergencies which result in sudden outage of such large generator unit. It also studies the factors involved in applying under frequency relays to maintan an allowable frequency level and to prevent total area collapse by automatic load shedding program.

  • PDF

The Study of Manufacture and Inertia Load Test of Inverter for Electrical Multiple Unit (전동차용 VVVF 인버터 제작 및 시험)

  • 한영재;김길동;박현준;이은규;한경희
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • In this paper, the IGBT VVVF inverter for 1C4M propulsion system of railway traction is studied. The inverter is consisted of IGBT stacks, a DB unit, and a control unit. The test results of the combined system is given, which shows an excellent performance of the overall system.

  • PDF

The Study on Cooling Load Forecast of an Unit Building using Neural Networks

  • Shin, Kwan-Woo;Lee, Youn-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.170-177
    • /
    • 2003
  • The electric power load during the summer peak time is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice storage system and heat pump system etc. are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice storage system is suggested. The method of forecasting the cooling load using neural network is also suggested. The daily cooling load is mainly dependent on actual temperature and humidity of the day. The simulation is started with forecasting the temperature and humidity of the following day from the past data. The cooling load is then simulated by using the forecasted temperature and humidity data obtained from the simulation. It was observed that the forecasted data were closely approached to the actual data.

A New Evaluation Method for the Effectiveness of Standardized Packing Module (포장모듈 표준화 효과의 평가 방법 연구)

  • Choi, Chang-Ho;Kim, Gwang-Ho;Park, Dong-Joo
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.6
    • /
    • pp.562-568
    • /
    • 2008
  • The modern logistics has tried not only to convert the conventional packing system into unit load system using pallet but also to enhance the fitness between packing facilities and transport modes. This is based on the goal to reduce total logistics cost by improving logistics efficiency. Since the packing unit can affect both loading rate and loading facilities, basic form of packing unit is very important to unit load system. The object of this study is to develop a new method for evaluating the effectiveness of standardized packing module. The new method is based on measure of effectiveness (MOE) which are identified by expert survey. This study has originality in that the collecting method for effectiveness of standardized packing module has not been developed up to now.