• Title/Summary/Keyword: unit load system

Search Result 743, Processing Time 0.035 seconds

Evaluation on Flexural Performance for Light-Weight Composite Floor with Sound Reduction System (층간소음 대응형 경량합성바닥판에 대한 휨성능 평가)

  • Bae, Kyu Woong;Lee, Sang Sup;Park, Keum Sung;Heo, Byung Wook;Hong, Sung Yub
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.3
    • /
    • pp.241-250
    • /
    • 2014
  • The purpose of this study is to propose structural technologies on the light-weight composite floor systems in the unit modular and to evaluate structural performance of the composite floor through flexural experiments. The flexural experiments were carried out on total nine specimens(each three type in shape) using steel flat deck and truss deck. From the results of test, all specimens showed the same failure patterns which exhibited deflection at the center of the specimens due to flexural deformation before concrete crushing at the upper of specimens. Also, we know that the proposed floors satisfied in serviceability and would be safe sufficiently. The ratio of experimental yield load by theoretical nominal load was the distribution of 0.86 to 1.27 with an average 1.04. Coefficient of variation in distribution showed good agreement.

Experimental Investigation on DeNOx Performance according to the Urea-SCR System Control at Various Operating Conditions for Diesel Engines (디젤엔진의 운전조건 변화 및 Urea-SCR 시스템 제어에 따른 DeNOx 성능에 대한 실험적 연구)

  • Han, Jung-Won;Gong, Ho-Jeong;Hwang, In-Goo;Myung, Cha-Lee;Park, Sim-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.76-83
    • /
    • 2010
  • Recently, as the current and future emission regulations go stringent, the research of NOx reduction has become a subject of increasing interest and attention in diesel engine. Selective Catalytic Reduction (SCR) is one of the effective technology to reduce NOx emission from diesel engine. Especially, Urea-SCR that uses urea as a reductant is becoming increasingly popular as a cost effective way of reducing NOx emissions from heavy duty vehicles. In this research, we designed urea injector and DCU (Dosing Control Unit) specially developed for controlling the Urea-SCR process onboard vehicles. As passenger and commercial diesel engine experiment, we grasped characteristics of NOx emission and SCR catalyst temperature level in advance. As a result, highest NOx emission level was shown in condition of low engine speed and high load. On the other hand, SCR catalyst temperature was highest at high engine speed and load. On the basis of these result, we conducted the NOx reduction test at steady engine operating conditions using the urea injector and DCU. It was shown that 74% NOx conversion efficiency on the average and 97% NOx conversion efficiency was obtained at high SCR catalyst temperature.

Development of Long Term Flow Duration Curves for the Management of Total Maximum Daily Loads - in the Nakdong River Basin - (수질오염총량관리 단위유역 장기유황곡선 구축 -낙동강수계를 대상으로-)

  • Kim, Gyeong hoon;Kwon, Heon gak;Ahn, Jung min;Kim, Sanghun;Im, Tae hyo;Shin, Dong seok;Jung, Kang-Young
    • Journal of Environmental Science International
    • /
    • v.26 no.8
    • /
    • pp.939-953
    • /
    • 2017
  • For the development of flow duration curves for the management of 41 Total Maximum Daily Load (TMDL) units of the Nakdong River basin, first, an equation for estimating daily flow rates as well as the level of correlation (correlation and determination coefficients) was extrapolated through regression analysis of discrete (Ministry of Environment) and continuous (Ministry of Land, Infrastructure and Transportation) measurement data. The equation derived from the analysis was used to estimate daily flow rates in order to develop flow duration curves for each TMDL unit. By using the equation, the annual flow duration curves and flow curves, for the entire period and for each TMDL unit of the basin, were developed to be demonstrated in this research. Standard flow rates (abundant-, ordinary-, low- and drought flows) for major flow duration periods were calculated based on the annual flow duration curves. Then, the flow rates, based on percentile ranks of exceedance probabilities (5, 25, 50, 75, and 95%), were calculated according to the flow duration curves for the entire period and are suggested in this research. These results can be used for feasibility assessment of the set values of primary and secondary standard flow rates for each river system, which are derived from complicated models. In addition, they will also be useful for the process of implementing TMDL management, including evaluation of the target level of water purity based on load duration curves.

Data Processing and Analysis of Non-Intrusive Electrical Appliances Load Monitoring in Smart Farm (스마트팜 개별 전기기기의 비간섭적 부하 식별 데이터 처리 및 분석)

  • Kim, Hong-Su;Kim, Ho-Chan;Kang, Min-Jae;Jwa, Jeong-Woo
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.632-637
    • /
    • 2020
  • The non-intrusive load monitoring (NILM) is an important way to cost-effective real-time monitoring the energy consumption and time of use for each appliance in a home or business using aggregated energy from a single recording meter. In this paper, we collect from the smart farm's power consumption data acquisition system to the server via an LTE modem, converted the total power consumption, and the power of individual electric devices into HDF5 format and performed NILM analysis. We perform NILM analysis using open source denoising autoencoder (DAE), long short-term memory (LSTM), gated recurrent unit (GRU), and sequence-to-point (seq2point) learning methods.

Three Dimensional Finite Element Analysis on ITI Implant Supported Fixed Partial Dentures with Various Fitting Accuracy (적합도에 따른 ITI 임플란트 지지 고정성 국소의치의 삼차원 유한요소 분석)

  • Choi, Min-Ho;Lee, Il-Kwon;Kim, Yu-Ree;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.1
    • /
    • pp.75-87
    • /
    • 2006
  • The purpose of this study was to investigate the effects of prostheses misfit, cantilever on the stress distribution in the implant components and surrounding bone using three dimensional finite element analysis. Two standard 3-dimensional finite element models were constructed: (1) 3 ITI implant supported, 3-unit fixed partial denture and (2) 3 ITI implant supported, 3-unit fixed partial denture with a distal cantilever. variations of the standard finite element models were made by placing a $100{\mu}m$ or $200{\mu}m$ gap between the fixture, the abutment and the crown on the second premolar and first molar. Total 14 models were constructed. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the distal marginal ridge of the distal molar. von Mises stresses were recorded and compared in the crowns, abutments, crestal compact bones, and trabecular bones. The results were obtained as follows: 1. In the ITI implant system, cement-retained prostheses showed comparatively low stress distributions on all the implant components and fixtures regardless of the misfit sizes under vertical loading. The stresses were increased twice under oblique loading especially in the prostheses with cantilever, but neither showed the effects of misfit size. 2. Under the oblique loading and posterior cantilever, the stresses were highly increased in the crestal bones around ITI implants, but effects of misfit were not shown. Although higher stresses were shown on the apical portion of trabecular bones, the effects by misfit were little and the stresses were increased by the posterior cantilever. 3. When the cement loss happened in the ITI implant supported FPD with misfit, the stresses were increased in the implant componets and supporting structures.

A Study of Liquid Nitrogen Inert Gas System for LNGC Diesel Engine Crank Chamber (LNGC 디젤기관 크랭크 챔버용 액체질소 불활성가스 시스템에 관한 연구)

  • Choi, Bu-Hong;Kim, Hyun-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.3
    • /
    • pp.279-285
    • /
    • 2012
  • It is necessary to install the inert gas system(IGS) for preventing fire and explosion in LNGC main diesel engine crankcase besides oil mist detector(OMD) unit with $CO_2$ gas injector. Therefore, to design the liquid nitrogen IGS, analytical work is conducted for predicting the heat input load of liquid nitrogen heater with two-phase stratified flow model. This paper also presents the effects of changes in pipe diameter, saturated pressure, and inclination angle by ship's movement on cryogenic two-phase stratified flows. It is found that the stratified model gives reasonable predictions, and the model is effective to predict the heat input load of liquid nitrogen IGS.

Verification Experiment of a Ground Source Multi-heat Pump at Cooling Mode (지열원 물대공기 멀티 히트펌프의 냉방 운전 특성에 관한 실증 연구)

  • Choi, Jong-Min;Kang, Shin-Hyung;Choi, Jae-Ho;Lim, Hyo-Jae;Moon, Je-Myung;Kwon, Young-Seok;Kwon, Hyung-Jin;Kim, Rock-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.5
    • /
    • pp.297-304
    • /
    • 2009
  • The aim of this study is to investigate the cooling performance of ground source multi-heat pump systems with a vertical single U-tube GLHX(U-tube system) and a vertical double tube GLHX(double tube system), which were installed in a school building located in Cheonan. All systems were operated in a part load conditions for all day, and the maximum COP of the single U-tube system and the double tube system were 6.2 and 5.2 at cooling mode, respectively. The double tube GLHX designed by the GLHEPRO, commercial program, was estimated to have the same performance as the U-tube GLHX, because the inlet temperatures of each outdoor unit heat exchanger for the former was similar to the latter. However, it is needed to prove the long tenn performance. It is suggested that the new algorithms to control the flow rate of secondary fluid for GLHX according to load variation have to be developed in order to enhance the performance of the system.

Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels (채광시스템과 인공조명설비의 통합기술 및 성능평가연구)

  • Kim, G.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

Development of Generation Planning System for Power Market Operation (전력시장 운영 발전계획시스템 개발)

  • Choi, Jae-Seok;Yoon, Yong-Tae;Cha, Jun-Min;Park, Jun-Hyeong;Ku, Bon-Hui;Oh, Tae-Gon;Lee, Sang-Sung;Baek, Ung-Ki;Choi, Hyeon-Il;Park, Sung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.364-365
    • /
    • 2011
  • This study develops a new system for generation system simulation and operational planning (namely, KPWR-X) including GMS(Generator Maintenance Scheduling), UC(Unit Commitment), and LF(Load Forecasting) for new power system environment in recent. The KPWR-X provides operator and planner to help the generation system more safely and economically. GUI developed in this study makes operator feel in convenient to control whole power system. In future, it is expected that generation company, ISO, and fuel procurement, etc. may use an instructional tool developer's suggestion for application. It will be also applicable to establish the operational strategies for generation control, fuel procurement and power system risk management.

  • PDF

A Study on the Automotive Suspension System for Energy Efficiency (에너지 절감형 자동차용 현가장치에 관한 연구)

  • 소상균
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.100-107
    • /
    • 2001
  • The main goals of the automotive suspension systems are to isolate roadway unevenness from the tire and to improve vehicle stability. To overcome the performance limitation of the passive systems the active systems which completely replace the passive spring and damper elements with a force generating actuator has been studied. However, application of the system has been limited because it has required a significant amount of power. Recently, alternative systems which retain passive elements but include active elements have been developed to reduce the power required. Those systems are mostly focused on the control system which compresses the spring-damper directly. In this study, a new type of power efficient control system which makes the spring-damper unit slide in side way is studied. After constructing the control system including dynamic modeling and motion control, two types of alternative control systems are compared in view of power consumption and dynamic attitudes such as roll responses as well as heave responses. Also, a half car bond graph model is developed to show clearly the significant differences in performances between two control systems.

  • PDF